Abstract: Objective To investigate changes of left ventricularregional systolic function after surgical treatment of left ventricular aneurysm (LVA) by realtime threedimensional echocardiography (RT-3DE). Methods From February 2009 to February 2010, 14 consecutive patients who were diagnosed to have coronary artery diseases with LVA underwent surgical repair and coronary artery bypass grafting (LVA group) in our hospital. All patients of the LVA group were followed up for a mean period of 4 months. Twodimensional echocardiography (2DE) and RT-3DE were performed before operation and during the follow-up. Left ventricular regional ejection fraction (EF) was acquired by Qlab software analysis. At the same time, 12 healthy persons were included as controls (control group). Statistical analyses were carried out to compare left ventricular regional EF between the LVA group (before operation and 4 months after operation) and the control group. Results Contrary to the control group, preoperative regional EF of the LVA group increased from apex to base. In addition to the inferior basal segment, lateralinferior basal segment and anteriorinferior basal segment, regional EF in the remaining 14 segments were significantly lower than that of the control group (P<0.05). At postoperative followup, regional EF recovered the increase from base to apex, and there was no significant difference between anteriorinferior segment and lateral segment regional EF of the LVA group and those of the control group (P>0.05), while regional EF of other segments in the LVA group was lower than that in the control group (P<0.05). Conclusion RT-3DE is an effective method to assess left ventricular regional systolic function in patients with LVA. After LVA repair and coronary artery bypass grafting, regional systolic function will restore to the normal direction of progressive increase, and some nonaneurysm segments systolic function will go back to normal.
ObjectiveTo evaluate myocardial segmental motion function in left ventricular of patients with rheumatic mitral stenosis by using the technology of real-time three-dimensional echocardiography (RT-3DE). MethodsWe retrospectively analyzed the clinical data of 14 patients with rheumatic mitral stenosis between October and November 2014 in our hospital as a trial group. There were 4 males and 10 females with a mean age of 50.9±9.0 years ranging from 34 to 64 years. We chose 11 healthy individuals as a control group. There were 7 males and 4 females with a mean age of 49.5±9.7 years ranging from 32 to 67 years. Both the two groups were subjected to myocardial performance evaluation using two-dimensional echocardiography (2DE) and real-time three-dimensional echocardiography (RT-3DE) to examine the left ventricular ejection fraction (LVEF), left ventricular end-diastolic volume (LVEDV), left ventricular end systolic volume (LVESV), longitudinal strain, circumferential strain, area strain, and lateral strain of each left ventricular myocardial segments. Result RT-3DE detected that the trial group had significantly lower values of LVEF, LVEDV and LVESV than those of the control group (P < 0.05). RT-3DE also revealed that the trial group had a significantly weaker longitudinal strain than the control group (P < 0.05). ConclusionRT-3DE is an accurate technology for assessing myocardial motion and function in patients with rheumatic mitral valve disease.
Objective To investigate the accuracy of positioning perforator of medial sural artery with three-dimensional ultrasound technique guided by a wide band linear matrix array volume transducer probe before operation, and the effectiveness of the flap design based on this in repairing the dorsal foot wounds. Methods Between January 2019 and December 2022, 30 patients with skin and soft tissue defects of the dorsal foot were treated. There were 19 males and 11 females, with an average age of 43.9 years (range, 22-63 years). There were 12 cases of traffic accident injury, 15 cases of heavy crushing injury, and 3 cases of machine injury. The time from injury to hospitalization was 1-8 hours (mean, 3.5 hours). The wounds in size of 5 cm×3 cm to 17 cm×5 cm were thorough debrided and covered with vacuum sealing drainage dressing. Then the wounds were repaired with the medial sural artery perforator flaps after no obvious infection observed. To obtain the complete three-dimensional image, the number and position of the medial sural artery perforator branches and the position of the main blood vessels in the muscle were detected and recorded by wide band linear matrix array volume transducer probe before operation. Suitable perforating branches were selected to design the flap and guide the flap incision on this basis. The size of the perforating flap ranged from 6 cm×4 cm to 18 cm×6 cm. The sensitivity and positive predictive value were calculated by comparing preoperative exploration with intraoperative observation of perforating branches, so as to evaluate the positioning accuracy of three-dimensional ultrasound technique. The donor sites were sutured directly in 25 cases and repaired with free skin grafting in 5 cases. Results The 60 perforating branches of medial sural artery were found before operation and 58 during operation in 30 patients. Among them, pre- and intra-operative perforations were consistent with 56. The sensitivity was 93.3% and positive predictive value was 96.6%. The intramuscular position and route of the main blood vessels were basically consistent with the pre- and intra-operative observation. All flaps survived and wounds healed by first intention. All incisions at the donor sites healed by first intention, and all skin grafts survived. All patients were follow up 9-24 months (mean, 14.7 months). The appearance, color, and texture of the flaps were good, and no obvious effect on wearing shoes and walking. At last follow-up, the American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hind score ranged from 80 to 92, with an average of 87.5. The patient satisfaction was excellent in 29 cases and good in 1 case. Conclusion The three-dimensional ultrasound technique guided by the wide band linear matrix array volume transducer probe can accurately locate the perforating branch of the medial sural artery, and the three-dimensional imaging is more intuitive, which can be used to guide the design and incision of the medial sural artery perforator flap.
Objective To explore the value of three-dimensional contrast-enhanced ultrasound angiography in the differential diagnosis of breast masses. Methods A total of 120 patients with breast masses who were treated in our hospital from July 2013 to February 2016 were selected as the research objects retrospectively, including 70 patients of benign tumor (benign group) and 50 patients of malignant tumor (malignant group) that confirmed by surgery and pathology. All patients were given conventional two-dimensional ultrasound and three-dimensional contrast-enhanced ultrasound angiography during the diagnosis. Compared the imaging features of benign group and malignant group, and compared the diagnostic value of two-dimensional ultrasound and three-dimensional contrast-enhanced ultrasound angiography for breast masses. Results Compared with benign group, the rates of irregular masses, unclear boundary, inhomogeneous echo, lateral shadowing, echo attenuation, and micro calcification in the malignant group were all higher (P<0.05). The three-dimensional contrast-enhanced ultrasound angiography scores in malignant group and benign group were significantly different with each other (P<0.05), the score of the malignant group was higher than that of benign group. The 2- and 3-score was common in benign group, but 4- and 5-score was common in malignant group. The diagnostic sensitivity of two-dimensional ultrasound and three-dimensional contrast-enhanced ultrasound angiography for breast masses were 97.1% (68/70) and 98.6% (69/70) respectively, and the specificity were 80.0% (40/50) and 96.0% (48/50) respectively, the specificity of three-dimensional contrast-enhanced ultrasound angiography was significantly higher than that of two-dimensional ultrasound (P<0.05). Conclusion Two-dimensional ultrasound and three-dimensional contrast-enhanced ultrasound angiography both have a certain diagnostic value in the differential diagnosis of breast masses, but the three dimensional contrast-enhanced ultrasound angiography can get more information through assessment of richness of the microvascular in tumor tissue, so as to improve the diagnostic specificity and is worthy of popularization and application.
ObjectiveTo study the value of transperineal three-dimensional ultrasound imaging in the diagnosis of pelvic organ prolapse (POP). MethodsFifty-two female patients undergoing transperineal three-dimensional ultrasound imaging between December 2011 and May 2013 were chosen for our study. Thirty-two of them with POP were designated into the observation group, and the other 20 patients with common gynecological diseases were regarded as the control group. Both the two groups of patients underwent transperineal three-dimensional ultrasound imaging in their resting state, action state (Valsalva deep inspiration followed by breath holding), and under levator ani muscle shrinking condition. These three kinds of state images clearly showed pelvic floor levator hiatus area and sagittal levator hiatus lengths change in the patients. ResultsPelvic floor was more relaxed in the observation group than that in the control group. The levator hiatus area and sagittal levator hiatus lengths were larger in the observation group than those in the control group, and the differences were significant (P<0.05). ConclusionTransperineal three-dimensional ultrasound imaging can better display pelvic anatomic structure, improve the effectiveness and accuracy of the diagnosis of pelvic organ prolapse, which is worthy of clinical application.
Objective To analyze the echocardiographic characteristics of above grade 3+ mitral regurgitation (MR) patients by 3D transesophageal echocardiography (3D-TEE) in transcatheter edge-to-edge repair (TEER) and compare the intervention rate of TEER treatment in patients with different risk stratification. Methods We retrospectively analyzed the clinical data of 91 patients with above grade 3+ MR in Anzhen Hospital between June 2021 and April 2022. There were 45 males and 46 females aged 66.5±15.9 years. According to pathogenesis, the patients were divided into different anatomical groups and risk stratification groups. There were 34 patients in a simple degenerative group (simple DMR group), 28 patietns in a complex disease group (Complex group), 14 patients in a simple ventricular functional reflux group (simple VFMR group), 9 patients in a simple atrial functional reflux group (simple AFMR group), and 6 patients in a mixed functional reflux group (mixed FMR group). All patients were examined with a unified standard of transthoracic echocardiography (TTE) and 3D-TEE to compare the characteristic three-dimensional structural changes of the mitral valve in each group. According to the three partition strategy of preoperative anatomical evaluation of TEER, the risk stratification was conducted for the enrolled patients, which was divided into three regions from light to heavy: green area, yellow area, and red area. TEER treatment intervention rate of patients with different risk stratification was calculated. Results Ant leaf angle and post leaf angle were negative in the simple DMR and Complex groups, and non-planar angle, prolapse height and prolapse volume were higher than those of the other groups (P=0.000). Ant leaf angle and post leaf angle were positive in the VFMR group and the mixed FMR group. Anterior and posterior (AP) diameter of valve ring (P=0.036), tenting height and tenting volume were higher than those of other groups (P=0.000). AP diameter, tenting height and tenting volume were changed mildly in patients with simple AFMR. MR patients in red and yellow zone achieved a 28.1% TEER intervention rate.Conclusion Standardized TTE and TEE examinations are crucial for the qualitative and quantitative diagnosis of MR in the echo core-lab. 3D-TEE mitral valve parameter can help determine the exact pathogenesis of MR and to improve the interventional rate of challenging MR patients.
A three-dimensional (3D) transrectal ultrasound (TRUS) imaging system is presented in this paper. The 3D imaging system is used for diagnosing diseases of prostate. The 3D image is reconstructed by a series of two-dimensional image data which is obtained through rectum. It can be a guide to prostate needle biopsies. The system is built by two parts: hardware and software. In the hardware, the mechanical device, stepper motor, control circuit, B Mode TRUS and personal computer (PC) workshop are presented. The software includes the firmware of micro control unit and software of the PC workshop. In order to evaluate the performance of the 3D imaging system, we did experiments with water and agar phantoms, and the results demonstrated the system's ability of 3D imaging with high-precision.