ObjectiveTo introduce and interpret ABCD classification system for subaxial cervical spine injury. MethodsThe literature related to subaxial cervical spine injury classification system was extensively reviewed, analyzed, and summarized so as to introduce the ABCD classification system. ResultsThe ABCD classification system for subaxial cervical spine injury consists of 3 parts. The first part of the proposed classification is an anatomical descri ption of the injury; it del ivers the information whether injury is bony, ligamentous, or a combined one. The second part is the classification of nerve function, spinal stenosis, and spinal instabil ity. The last part is optional and denotes radiological examination which is used to define injury type. Several letters have been used for simplicity to del iver the largest amount of information. And a treatment algorithm based on the proposed classification is suggested. ConclusionThe ABCD classification system is proposed for simplification. However further evaluation of this classification is needed.
Objective To discuss the selection of anterior or posterior or a combination of anterior and posterior surgical treatment of lower cervical dislocation. Methods A retrospectively study was performed on 28 patients with lower cervical dislocation who received operative treatment between January 2005 and October 2008. There were 19 males and 9 femaleswith an average age of 38 years (range, 19-57 years), including 21 cases of fresh dislocation and 7 cases of old dislocation. The time from injury to hospitalization was 3 hours to 58 days. According to Allen classification, all cases had flexion injury, including 19 cases of degree I dislocation, 2 cases of degree II, 5 cases of degree III, and 2 cases of degree IV. At admission according to Frankel classification, 7 cases were rated as grade A, 4 as grade B, 9 as grade C, 3 as grade D, and 5 as grade E. All patients received open reduction, internal fixation, and il iac bone graft spinal fusion. Of them, combined anterior and posterior approach operation were given in 4 cases, single anterior operation in 22 cases, and single posterior operation in 2 cases. Results All operations were completed successfully and the spinal cord injury did not deteriorate after operation. Esophageal fistula occurred in 1 case receiving anterior approach operation and was cured after 1 month. Infection of wound occurred in 1 case and was cured after dressing change. The other incisions healed by first intention. One case (Frankel grade A) died of pulmonary infection 6 weeks after operation. Twenty-seven patients were followed up 21-38 months. Two cases suffered from shoulder pain 12 months after operation. X-ray films showed complete reduction, normal height of vertebral space and normal sequence of cervical spine after operation. All cases obtained bone fusion after 3.5-6.0 months of operation (4.2 months on average). Frankel grades were improved in different degrees after operation. Conclusion The operation plan of lower cervical dislocation should be determined by the neurologic status of the patient, and the classification of the injury as a unilateral or bilateral dislocation. Anterior cervical discectomy, fusion, and fixation were available in the lower cervical dislocation.
ObjectiveTo observe the in vivo three-dimensional (3-D) transient motion characteristics of the subaxial cervical spine in healthy adults. MethodsSeventeen healthy volunteers without cervical spine related diseases were recruited for this study, including 8 males and 9 females with a mean age of 26 years (range, 23-41 years). The vertebral segment motion of each subject was reconstructed with CT, and Rhinoceros 4.0 solid modeling software were used for 3-D reconstruction model of the subaxial cervical spine. In vivo cervical vertebral motion in flexionextension, left and right bending, left and right rotation was observed with dual fluoroscopic imaging system (DFIS). Coordinate systems were established at the vertebral center of C3-7 to obtain the intervertebral range of motion (ROM) and displacement at C3, 4, C4, 5, C5, 6, and C6, 7. The X-axis pointed to the left along the coronal plane, the Y-axis pointed to the back along the sagittal plane, and the Z-axis perpendicular to the X-Y plane pointed to the head. The ROM along X, Y, and Z axises were represented by rotation in flexion-extension (α), in left-right bending (β), and in left-right twisting (γ) respectively, and the displacement in left-right direction (x), in anterior-posterior direction (y), and in proximaldistal direction (z), respectively. ResultsIn flexion and extension, the displacement in anterior-posterior direction of C6, 7 was significantly less that of other segments (P<0.05), but the displacements in left-right direction and in proximaldistal direction showed no significant difference between segments (P>0.05); the ROM values in flexion-extension of C4, 5 and C5, 6 were significantly larger than those of C3, 4 and C6, 7 (P<0.05), and the ROM value in left-right twisting of C4, 5 was significantly larger than those of C5, 6 and C6, 7 (P<0.05), but the ROM value in left-right bending showed no significant difference between segments (P>0.05). In left and right bending, there was no significant difference in the displacement between other segments (P>0.05) except that the displacement in anterior-posterior direction of C3, 4 was significantly larger than that of C4, 5 (P<0.05), and that the displacement in proximal-distal direction of C6, 7 was significantly less than that of C3, 4 and C4, 5 (P<0.05); no significant difference was shown in the ROM value between segments (P>0.05), except that the ROM value in left-right twisting of C3, 4 was significantly larger than that of C5, 6 and C6, 7 (P<0.05). In left and right rotation, the ROM value in left-right twisting of C3, 4 was significantly larger than that of C4, 5 and C6, 7 (P<0.05), and the displacement and ROM value showed no significant differece between other segments (P>0.05). ConclusionThe intervertebral motions of the cervical spine show different characters at different levels. And the 6-degree-of-freedom data of the cervical vertebrae are obtained, these data may provide new information for the in vivo kinematics of the cervical spine.
Objective To assess the cl inical significance of transpedicular screw insertion in lower cervical vertebra assisted by multi-spiral CT (MSCT) three dimentional (3D) image reconstruction techniques. Methods Eight cervical vertebra specimens were examined by MSCT, and the messages were sent to SGI02 Workstation; according to the parameter requirements of lower cervical pedicle fixation, by using post-process of volume rendering (VR) the condition was judged and multi-plannar reformation (MPR) was used to do individual analysis; and the ideal path of screw insertion was obtained andthe related parameters were measured. After preoperative plan being finished, referring to these measured parameters, 3.5 mm screws were inserted into C3-7 pedicles of these 8 specimens. After insertion of screws, MSCT scanning and 3D reconstruction were performed again to evaluate the accuracy of lower cervical pedicle screw inserting. From May 2007 to November 2009, 28 patients who received screw insertion in lower cervical spines were given MSCT scanning and 3D reconstruction to evaluate the illness situation, to confirm shortest fixation volumes, and to collect the parameters of aim pedicle screw insertion. Results The time of insertion for each screw was (392 ± 62) seconds. It was found that one pedicle was clausura (1.25%, 1/80) and five pedicle diameters in coronal view were less than 3 mm (6.25%, 5/80), which all were not fit for screw insertion. A total of 74 screws were placed successfully. One-time success rate of screw insertion was 95.95% (71/74). The total accuracy rate was 91.89% (68/74). Six screws penetrated (8.11%). According to the Richter penetrating classification: grade one was 6.76% (5/74) and grade two was 1.35% (1/74). There were significant differences (P lt; 0.05) in penetrated rate between our study and anatomic landmark local ization (47.37%), Miller methods (25.00%), and there was no significant difference (P gt; 0.05) when compared with Abumi method (6.70%), hopper method (7.10%), pipel ine deoppilation method (5.20%) and navigation technique (11.30%). In cl inical 28 cases, 121 screws were inserted; one pedicle was clausura and one was fissure fracture, which all were unfit for insert screw in preoperative plan, the surgery project was adjusted. After operation, 17 patients (76 screws) were given MSCT scanning again. A total of 67 screws (88.16%) were placed successfully. Nine screws (11.84%) penetrated, grade one was 7.89% (6/76) and grade two was 3.95% (3/76). Conclusion It is accurate to apply MSCT 3D reconstruction techniques to measure the ideal screw canal in preoperative individual ized plan. Strictly following individual quantitative data, the safety and accuracy of the surgery can be improved. And it is feasible and available to use MSCT MPR imaging to evaluate the accuracy of pedicle screw insertion.
This study aims to develop and validate a three-dimensional finite element model of inferior cervical spinal segments C4-7 of a healthy volunteer, and to provide a computational platform for investigating the biomechanical mechanism of treating cervical vertebra disease with Traditional Chinese Traumotology Manipulation (TCTM). A series of computed tomography (CT) images of C4-7 segments were processed to establish the finite element model using softwares Mimics 17.0, Geromagic12.0, and Abaqus 6.13. A reference point (RP) was created on the endplate of C4 and coupled with all nodes of C4. All loads (±0.5, ±1, ±1.5 and ±2 Nm) were added to the RP for the six simulations (flexion, extension, lateral bending and axial rotation). Then, the range of motion of each segment was calculated and compared with experimental measurements of in vitro studies. On the other hand, 1 Nm moment was loaded on the model to observe the main stress regions of the model in different status. We successfully established a detail model of inferior cervical spinal segments C4-7 of a healthy volunteer with 591 459 elements and 121 446 nodes which contains the structure of the vertebra, intervertebral discs, ligaments and facet joints. The model showed an accordance result after the comparison with the in vitro studies in the six simulations. Moreover, the main stress region occurred on the model could reflect the main stress distribution of normal human cervical spine. The model is accurate and realistic which is consistent with the biomechanical properties of the cervical spine. The model can be used to explore the biomechanical mechanism of treating cervical vertebra disease with TCTM.
ObjectiveTo investigate the effectiveness of cervical pedicle screw implantation technique under regional method.MethodsThe clinical data of 85 patients who met the selection criteria between April 2010 and May 2018 were retrospectively analyzed. There were 57 males and 28 females, aged 35-68 years, with an average of 57.6 years. Among them, there were 10 cases of ossification of posterior longitudinal ligament, 68 cases of cervical spondylosis with multilevel stenosis, 3 cases of cervical tumor, 1 case of congenital malformation, and 3 cases of cervical trauma; the lower cervical spine lesions involved C3-C7. Preoperative Frankel spinal cord injury grading: 2 cases of grade C, 51 cases of grade D, and 32 cases of grade E. Cervical pedicle screw implantation technique under regional method was performed with a total of 618 pedicle screws. Postoperative changes in neurological symptoms were observed; cervical mouth opening anteroposterior and lateral X-ray films and cervical CT examinations were performed to evaluate the pedicle screws position.ResultsThe operation time was 2.5-4.0 hours, with an average of 3.0 hours. The intraoperative blood loss was 180-550 mL, with an average of 345 mL. No intraoperative vascular or nerve injury occurred. The patients with neurological symptoms were relieved to varying degrees. There were 2 cases of superficial incision infection after operation, the wound healed after enhanced dressing change. The postoperative hospital stay was 5-14 days, with an average of 8.4 days. At discharge, Frankel neurological grading was grade D in 26 patients and grade E in 59 patients. All the patients were followed up 6-24 months, with an average of 13 months. At last follow-up, cervical X-ray films showed the good pedicle screw fixation without loosening. Cervical CT evaluated the position of pedicle screws: 523 pedicle screws (84.7%) in grade Ⅰ, 80 (12.9%) in grade Ⅱ, and 15 (2.4%) in grade Ⅲ; the accuracy rate of the screw position was 97.6%.ConclusionCervical pedicle screw implantation technique under regional method can significantly improve the success rate of screw implantation. It is easy to operate, does not destroy the bone cortex, and has stable fixation.
Objective To compare the biomechanical properties of the anterior transpedicular screw-artificial vertebral body (AVB) and conventional anterior screw plate system (AP) in lower cervical spine by finite element study. Methods CT images (C1-T1) were obtained from a 38-year-old female volunteer. The models of intact C3-7 (intact group), AP fixation (AP group), and AVB fixation (AVB group) were established and analyzed by Mimics 14.0, Geomagic Studio 2013, and ANSYS 14.0 softwares. The axial force of 74 N and moment couple of 1 N·m were loaded on the upper surface and upper facet joint surfaces of C3. Under conditions of flexion, extension, lateral bending, and rotation, the Von Mises stress distribution regularity and maximum equivalent stree of AP and AVB groups were recorded, and the range of motion (ROM) was also analyzed of 3 groups. Results The intact model of lower cervical spine (C3-7) was established, consisting of 286 382 elements and 414 522 nodes, and it was successfully validated with the previously reported cadaveric experimental data of Panjabi and Kallemeyn. The stress concentrated on the connection between plate and screw in AP group, while it distributed evenly in AVB group. Between AP and AVB groups, there was significant difference in maximum equivalent stress values under conditions of 74 N axial force, flexion, extension, and rotation. AVB group had smaller ROM of fixed segments and larger ROM of adjacent segments than AP group. Compared with intact group, whole ROM of the lower cervical spine decreased about 3°, but ROM of C3, 4 and C6, 7 segments increased nearly 5° in both AP and AVB groups. Conclusion As a new reconstruction method of lower cervical spine, AVB fixation provides better stability and lower risk of failure than AP fixation.
This study aims to investigate the range of motion (ROM) and the stress variation in the intervertebral disc and the vertebral body on adjacent segments and the influence of force transmission mode after the dynamic cervical implant (DCI) surgery. Two types of surgery, DCI implantation and interbody fusion were used to establish the finite element model of the cervical C5, 6 segment degeneration treatment. The ROM and the adjacent discs and vertebral body stresses of two procedures under flexion, extension, lateral bending and axial rotation working conditions were analyzed. The results showed that ROM of the surgical segment in DCI model was well preserved and could restore to the normal ROM distributions (reduction of the amplitude was less than 25%), and the kinetic characteristics of adjacent segments was less affected. In fusion surgery model, however, ROM of the surgical segment was reduced by 86%-91%, while ROM, disc stress and vertebral stress of adjacent segments were increased significantly, and stress of the C5 vertebral body was increased up to 171.21%. Therefore DCI surgery has relatively small influence on cervical ROM and stress. The study provides a theoretical basis for DCI and fusion surgery in clinic.