With the expanding indications for transcatheter aortic valve replacement (TAVR) guidelines, combined valvular disease is often encountered in the clinic, and existing relevant studies have shown that preoperative moderate to severe mitral regurgitation is associated with higher mortality. In these patients, the optimal treatment strategy for TAVR with evidence-based heart failure, TAVR with transcatheter mitral intervention, or staging transcatheter therapy are unclear. Therefore, a comprehensive assessment of the anatomy and function of the aortic and mitral valves, as well as an in-depth assessment of the patient’s baseline risk profile, are the basis for an individualized approach to treatment. This article will review the results of the relevant research to better help clinicians diagnose and treat relevant patients.
ObjectiveTo summarize and analyze the risk factors and management of artificial valve slippage in transcatheter aortic valve implantation (TAVI).MethodsWe retrospectively analyzed the clinical data of 131 patients undergoing TAVI surgery in our center from September 2017 to May 2019, including 62 patients through transapical approach and 69 patients through transfemoral artery approach.ResultsA total of 131 patients received TAVI surgery, among whom 4 patients had slipped during the operation, 2 patients via transfemoral artery approach, and another 2 patients via transapical. The average age was 77±9 years with one female (25%). Preoperative evaluation, higher position and poor coaxial were main risk factors for valve slip in TAVI.ConclusionValve slippage is also a serious complication in TAVI surgery. Reasonable and effective treatment can avoid thoracotomy.
The purpose of this study was to explore the feasibility of dual-source computed tomography (DSCT) high-pitch scan mode in the preoperative evaluation of severe aortic stenosis (AS) referred to transcatheter aortic valve implantation (TAVI). Thirty patients with severe AS referred for TAVI underwent cervico-femoral artery joint DSCT angiography. Measurement and calculation of contrast, contrast noise ratio (CNR) and noise of aorta and access vessels were performed. The intra-and inter-observer reproducibilities for assessing aortic root and access vessels were evaluated. Evaluation of shape and plagues of aorta and access vessels was performed. The contrast, CNR and noise of aorta and access vessels were 348.2~457.9 HU, 12.2~30.3 HU and 19.1~48.1 HU, respectively. There were good intra-and inter-observer reproducibilities in assessing aortic root and access vessels by DSCT (mean difference:-0.73~0.79 mm, r=0.90~0.98, P < 0.001; mean difference:-0.70~0.73 mm, r=0.90~0.96, P < 0.001). In the 30 patients, the diameters of external iliac artery, femeral artery or subclavian artery were less than 7 mm in 5 cases (16.7%), marked calcification in bilateral common iliac arteries in 1 case (3.3%) and marked soft plaque in left common iliac artery in 1 case (3.3%). DSCT high-pitch scan mode was feasible in the preoperative evaluation of aorta and access vessels in patients with AS referred for TAVI.
ObjectiveBy comparing the difference between different stenosed degree of aortic valve in flow field uniformity and turbulent shear stress (TSS), to explore the relation between flow field uniformity and different stenosed degree of aortic valve, and probe the clinical value for deciding the operation timing, and analyze the possible role of TSS in the progress of the disease.MethodsThe flow field uniformity values and TSS in parasternal long axis plane and apical five cavity plane on each point were measured and calculated by pulse wave Doppler echocardiography technique for 33 patients with different stenosed degree of aortic valve.ResultsThere were significant difference between the different stenosed degree of aortic valve in maximal velocity difference(ΔV max )and TSS( P lt;0.05, 0.01). The more severe the aortic stenosis was, the worse the flow field uniformity was, the lower the TSS was.ConclusionsThere are significant difference between the patients of different stenosed degree of aortic valve in flow field uniformity. Flow field uniformity has important value in classifying the degree of aortic stenosis and deciding the timing of operation. The more severe the aortic stenosis is ,the lower TSS is. It can be thought that low TSS distribution has important role in pathological process of constriction in cardiovascular system diseases.
This paper discusses a female patient with severe aortic stenosis, who was preoperatively assessed to be at high risk of left coronary artery occlusion, but developed complete occlusion of the right coronary artery during the procedure of transcatheter aortic valve replacement, leading to hemodynamic disorder. Surgical treatment under emergency cardiopulmonary bypass played a critical role in rescuing the patient.
Objective To evaluate the safety and efficacy of transcatheter aortic valve replacement (TAVR) using the SAPIEN 3 system. MethodsThis was a prospective, multicenter, single arm study in 4 centers in China. The clinical data of 50 patients with high-risk symptomatic severe aortic stenosis who underwent TAVR using the SAPIEN 3 system from June 2017 to June 2019 were analyzed, including 27 males and 23 females aged 76.8±6.1 years. ResultsThe Society of Thoracic Surgeon score was 6.0%±2.8%. Totally, 20.0% of patients had severe bicuspid aortic stenosis. The operation time was 41.8±16.5 min and the hospital stay time was 8.5±5.0 d. At the postoperative 30-day follow-up, no all-cause mortality occurred and the device success rate was 89.5%. Major vascular complications occurred in one (2.0%) patient, stroke in one (2.0%) patient, new pacemaker implantation in one (2.0%) patient, as well as coronary artery obstruction in one (2.0%) patient. There was no moderate or moderate/severe paravalvular leak. The aortic pressure gradient was decreased from 49.2±16.2 mm Hg before the operation to 12.4±4.6 mm Hg at the postoperative 30-day follow-up, and the valvular area was increased from 0.6±0.3 cm2 to 1.3±0.3 cm2 (P<0.01). Moreover, the New York Heart Association classification in 83.7% of the patients was improved during the follow-up. ConclusionThis pre-marketing multicenter study has demonstrated the safety and effectiveness of transfemoral TAVR with the SAPIEN 3 transcatheter valve system in Chinese aortic stenosis patients at high risk for surgery.