Transcatheter aortic valve replacement (TAVR) has entered a new and critical stage after nearly 20 years of rapid development in China. There are various types of TAVR valves with different advantages. TAVR can be performed through various approaches such as transfemoral artery, transapical, trans-carotid artery, or trans-ascending aorta. The first two are more common. Echocardiography plays an important role in the perioperative period of TAVR. Compared to transfemoral approach, transapical TAVR has different key points in perioperative echocardiography which is lack of unified and accurate standards. This standard is specially formulated to focus on the key points of echocardiography in preoperative screening, intraoperative monitoring and postoperative follow-up in order to promote the safe and effective application of transapical TAVR in the clinic.
ObjectiveTo systematically review the predictive factors of new-onset conduction abnormalities(NOCAs) after transcatheter aortic valve replacement (TAVR) in bicuspid aortic valve (BAV) patients. MethodsThe CNKI, VIP, WanFang Data, PubMed, Cochrane Library and EMbase databases were electronically searched to collect the relevant studies on NOCAs after TAVR in patients with BAV from inception to December 5, 2022. Two researchers independently screened the literature, extracted data, and assessed the risk of bias of the included studies. Meta-analysis was then performed by using RevMan 5.4 software. ResultsSix studies involving 758 patients with BAV were included. The results of the meta-analysis showed that age (MD=−1.48, 95%CI −2.73 to −0.23, P=0.02), chronic kidney disease (OR=0.14, 95%CI 0.06 to 0.34, P<0.01), preoperative left bundle branch block (LBBB) (OR=2.84, 95%CI 1.11 to 7.23, P=0.03), membranous septum length (MSL) (MD=0.93, 95%CI 0.05 to 1.80, P=0.04), implantation depth (ID) (MD=−2.06, 95%CI −2.96 to −1.16, P<0.01), the difference between MSL and ID (MD=3.05, 95%CI 1.92 to 4.18, P<0.01), and ID>MSL (OR=0.27, 95%CI 0.15 to 0.49, P<0.01) could be used as predictors of NOCAs. ConclusionCurrent evidence shows that age, chronic kidney disease, LBBB, MS, ID, the difference between MSL and ID, and ID>MSL could be used as predictors of NOCAs. Due to the limited quantity and quality of included studies, more high-quality studies are required to verify the above conclusion.
“Valve-in-valve” technique is an effective method to treat the bioprosthesis structural valve degeneration. In this paper, an 82-year-old male patient with severe aortic valve regurgitation had underwent surgical aortic valve replacement. He had a bioprosthesis structural valve degeneration which caused severe aortic stenosis more than 3 years after surgery. His symptoms of chest distress and short breath were aggravated progressively, and not relieved by conventional treatment. As the deterioration in his unstabled circulation system, an emergency transcatheter aortic valve replacement was conducted for him. The operation was finally successful, the symptoms were relived significantly after operation, and then the follow-up indicated that he had a good recovery.
Objective To investigate the left ventricular reverse remodeling (LVRR) in patients with aortic valve insufficiency with reduced ejection fraction (AIrEF) and aortic valve insufficiency with preserved ejection fraction (AIpEF) after transcatheter aortic valve replacement (TAVR). MethodsThe clinical and follow-up data of patients who underwent TAVR in the Department of Cardiothoracic Surgery, Xinhua Hospital Affiliated to Shanghai Jiao Tong University School of Medicine from 2018 to 2021 were retrospectively analyzed. According to the guideline, the patients with left ventricular ejection fraction<55% were allocated to an AIrEF group, and the patients with left ventricular ejection fraction≥55% were allocated to an AIpEF group. ResultsA total of 50 patients were enrolled. There were 19 patients in the AIrEF group, including 15 males and 4 females with a mean age of 74.5±7.1 years. There were 31 patients in the AIpEF group, including 19 males and 12 females with a mean age of 72.0±4.8 years. All patients underwent TAVR successfully. Echocardiographic results showed that TAVR significantly promoted LVRR in the patients. Significant LVRR occurred in the early postoperative period (the first day after the surgery) in both groups. It remained relatively stable after the LVRR in the early postoperative period (the first day after surgery) in the AIpEF patients, while it continued to occur in the early postoperative period (the first day after surgery) to three months after the surgery in the AIrEF patients, and then remained relatively stable. Compared to preoperative values, AIrEF patients had a reduction in the average left ventricular end-diastolic volume index and left ventricular end-systolic volume index by 16.8 mL/m2 (P=0.003) and 8.6 mL/m2 (P=0.005), respectively, and the average left ventricular end-diastolic diameter index and end-systolic diameter index decreased by 2.5 mm/m2 (P=0.003) and 1.9 mm/m2 (P=0.003), respectively on the first day after the surgery. In comparison to the first day after the surgery, AIrEF patients experienced an average increase of 12.1% in the left ventricular ejection fraction three months after the surgery (P<0.001). ConclusionTAVR has achieved good therapeutic effects in patients with aortic valve insufficiency, significantly promoting the LVRR in patients, and has better curative effects in AIrEF patients.
Objective To evaluate the safety and early-stage efficacy of transcatheter aortic valve replacement (TAVR) for severe aortic stenosis (AS) using a new generation balloon-expandable (BE) valve by collecting the baseline and follow-up data. Methods We retrospectively reviewed the clinical data of severe AS patients who received TAVR with BE valve (Sapien 3) in Fuwai Hospital from September 2020 to June 2022. We collected the echocardiographic data as well as follow-up results at post-procedure, 1, 3, 6 and 12 months. According to the Sievers classification criteria, the patients were divided into a normal group and a bicuspid aortic valve group. Results Finally 62 patients were collected, including 31 females and 31 males with an average age of 71.44±9.17 years. There was 61 patients implanted successfully with BE valve and only 1 was transferred to surgical replacement. There was no mortality or severe complications. Echocardiographic assessment showed significant reduction of the pressure gradient (P<0.001) and the effect was consistent to postoperative 12 months. After the treatment of patients with different aortic valve morphology using balloon dilation, the condition of valve stenosis improved. ConclusionThe use of BE valves has good safety and early efficacy in patients with severe AS of different valve morphology.
目的观察微创体外循环(minimal extracorporeal circulation,MECC)对主动脉瓣置换术临床效果的影响。 方法回顾性分析我院2010年3月至2012年10月共25例应用MECC方法行单纯主动脉瓣置换术(AVR)的临床资料,其中男15例、女10例,年龄40(19~58)岁。 结果总体外循环时间67(51~89)min、主动脉阻断时间42(33~63)min、转流中最低血红蛋白(Hb)9.6(8.3~12.6)g/dl、流转后Hb 9.5(7.7~12.6)g/dl,体外循环中无1例患者因Hb低而输入红细胞。所有患者均顺利拔除胸腔引流管,顺利出院,无院内死亡。 结论MECC系统应用于主动脉瓣置换安全可行,比传统心肺旁路系统具有更好的生物相容性和良好的临床结果,值得推广。
Due to the lack of calcification of the aortic valve, it is difficult to provide effective support for the fixation of artificial valve in aortic stenosis characterized by leaflet thickening. There is a risk of postoperative perivalvular leakage and secondary valve implantation, which is widely regarded as a relative contraindication for transcatheter aortic valve replacement (TAVR). But aortic valvuloplasty and self-expanding transcatheter aortic valve has showed its safety and efficacy. This paper reports a patient with bicuspid aortic valve characterized by leaflet thickening treated with TAVR. After the operation, the patient’s symptom of exertional dyspnea was significantly improved, New York Heart Association class increased to Ⅱ, no perivalvular leakage was found, and the mean transaortic pressure gradient and the maximum aortic valve velocity decreased significantly.
An 84-year-old severe aortic stenosis patient admitted with acute heart failure was reported. Transcatheter aortic valve replacement (TAVR) was proposed. The patient was at high risk of the left coronary artery occlusion in preoperative and intraoperative evaluation. Coronary artery protection was performed by pre-embedded coronary artery guide wire and stent during the TAVR. The left coronary artery was partially blocked by valve leaflet after 23 mm self-expanding aortic valve was released. Coronary revascularization was not performed as the coronary blood flow was not affected. However, the patient suffered acute myocardial infarction with hypotension on the third day after TAVR. Emergency angiography showed that left coronary artery was more blocked than before and the condition improved after left main coronary stent implantation. This case suggested that aggressive coronary revascularization should be considered for high risk of coronary artery obstruction during TAVR, especially for partial obstruction of coronary artery.
Transcatheter aortic valve replacement has revolutionized the management of aortic stenosis and become the gold standard for the treatment of symptomatic and severe aortic valve stenosis in elderly patients. With the improvement in design and materials, newer generation transcatheter aortic valve prostheses had overcome the limitations of early-generation devices that were susceptible to paravalvular leak, atrioventricular block and vascular complications, to a certain extent. This review provides an update on the latest advances in transcatheter aortic valve prostheses.
This paper discusses a female patient with severe aortic stenosis, who was preoperatively assessed to be at high risk of left coronary artery occlusion, but developed complete occlusion of the right coronary artery during the procedure of transcatheter aortic valve replacement, leading to hemodynamic disorder. Surgical treatment under emergency cardiopulmonary bypass played a critical role in rescuing the patient.