A 78-year-old female patient was admitted to West China Hospital of Sichuan University because of “amaurosis and polypnea for 4+ years”. The examination results before admission showed that severe stenosis of aortic valve, bicuspid aortic valve malformation, severe horizontal heart with 61.54° aortic angle. The preoperative evaluation of the patient indicated that the Society of Thoracic Surgeons score was 17.9%, which was high risk for surgery. After discussion by the heart team, the aortic stenosis was finally relieved by transcatheter aortic valve replacement. The operation was successfully completed by using the method of pulling and releasing the device with the same side basket. One month follow-up showed that the patient’s condition was stable and no complications occurred. This case aims to provide a reference for the treatment of horizontal heart with aortic stenosis. In the future, it is hoped that through continuous clinical practice, such patients will be provided with a safer and more efficient treatment plan.
Transcatheter aortic valve replacement (TAVR) is a mature technology. Because of the complicated valvular anatomy and the severe non-symmetrical valve calcification, the patient with bicuspid aortic valve stenosis (BAVs) once having a lower procedure successful rate, was considered as the relative contradiction for TAVR. However, with the application of the skirted and retrievable next generation prosthesis system, the outcomes of the treatment have been greatly improved. In this article, we summarized the current situation of TAVR applied in BAVs, and the outcomes difference of the old and new generation prosthesis systems.
ObjectiveTo explore the preoperative evaluation result of multidetector computed tomography (MDCT) in aortic stenosis (AS) patients with bicuspid aortic valve (BAV) undergoing transcatheter aortic valve replacement (TAVR) in order to summarize relevant experience.MethodsA total of 33 consecutive AS patients who underwent TAVR in Department of Cardiology, First Affiliated Hospital of Xinjiang Medical University from March 2016 to June 2020 were enrolled, and the preoperative evaluation characteristics of MDCT were compared between tricuspid aortic valve (TAV) and BAV.ResultsIn the 33 patients, whose mean age was (74±6) years, 22 were male and 11 were female, 17 were with BAV and 16 were with TAV. The medium (lower quartile, upper quartile) of calcification score was 360 (192, 1 034) mm3. There were 12 cases of artificial valve model to be speculated Downsize, including 9 calcific BAV cases (75%).ConclusionThe calcific BAV has a higher ratio of Downsize in the TAVR procedure.
ObjectiveTo compare the clinical outcomes of bicuspid aortic valve stenosis (BAV) and tricuspid aortic valve stenosis (TAV) after transcatheter aortic valve replacement (TAVR).MethodsA computer-based search in PubMed, EMbase, The Cochrane Library, CBM, CNKI and Wanfang databases from their date of inception to March 2019 was conducted. Two reviewers independently screened the articles, extracted data and evaluated their quality. RevMan 5.3 and Stata 15.0 softwares were used for meta-analysis.ResultsThe selected 15 cohort studies contained 45 770 patients, including 1 500 of BAV patients and 44 270 of TAV patients. The results showed that no statistical difference was found in postoperative in-hospital mortality [OR=1.29, 95%CI (0.91, 1.83), P=0.15], 30-day mortality [OR=1.23, 95%CI (0.86, 1.77), P=0.25], and 1-year mortality [OR=1.14, 95%CI (0.87, 1.50), P=0.33] between the two groups. The surgical success rate [OR=0.57, 95%CI (0.44, 0.74), P<0.01], postoperative bleeding events [OR=0.72, 95%CI (0.58, 0.91), P<0.01] and postoperative vascular injury [OR=0.68, 95%CI (0.47, 0.97), P=0.03] of patients in the BAV group were lower than those in the TAV group. The incidence of paravalvular leak in the BAV group was higher than that in the TAV group [OR=1.47, 95%CI (1.13, 1.90), P<0.01]. No significant difference was found between the two groups in terms of conversion to surgery, postoperative myocardial infarction, postoperative renal failure, postoperative neurologic events, postoperative valve gradient difference and pacemaker implantation.ConclusionCompared with TAV, the application of TAVR in BAV patients is feasible and effective.
Objective To explore the key genes, pathways and immune cell infiltration of bicuspid aortic valve (BAV) with ascending aortic dilation by bioinformatics analysis. Methods The data set GSE83675 was downloaded from the Gene Expression Omnibus database (up to May 12th, 2022). Differentially expressed genes (DEGs) were analyzed and gene set enrichment analysis (GSEA) was conducted using R language. STRING database and Cytoscape software were used to construct protein-protein interaction (PPI) network and identify hub genes. The proportion of immune cells infiltration was calculated by CIBERSORT deconvolution algorithm. Results There were 199 DEGs identified, including 19 up-regulated DEGs and 180 down-regulated DEGs. GSEA showed that the main enrichment pathways were cytokine-cytokine receptor interaction, pathways in cancer, regulation of actin cytoskeleton, chemokine signaling pathway and mitogen-activated protein kinase signaling pathway. Ten hub genes (EGFR, RIMS3, DLGAP2, RAPH1, CCNB3, CD3E, PIK3R5, TP73, PAK3, and AGAP2) were identified in PPI network. CIBERSORT analysis showed that activated natural killer cells were significantly higher in dilated aorta with BAV. Conclusions These identified key genes and pathways provide new insights into BAV aortopathy. Activated natural killer cells may participate in the dilation of ascending aorta with BAV.
ObjectiveTo systematically review the predictive factors of new-onset conduction abnormalities(NOCAs) after transcatheter aortic valve replacement (TAVR) in bicuspid aortic valve (BAV) patients. MethodsThe CNKI, VIP, WanFang Data, PubMed, Cochrane Library and EMbase databases were electronically searched to collect the relevant studies on NOCAs after TAVR in patients with BAV from inception to December 5, 2022. Two researchers independently screened the literature, extracted data, and assessed the risk of bias of the included studies. Meta-analysis was then performed by using RevMan 5.4 software. ResultsSix studies involving 758 patients with BAV were included. The results of the meta-analysis showed that age (MD=−1.48, 95%CI −2.73 to −0.23, P=0.02), chronic kidney disease (OR=0.14, 95%CI 0.06 to 0.34, P<0.01), preoperative left bundle branch block (LBBB) (OR=2.84, 95%CI 1.11 to 7.23, P=0.03), membranous septum length (MSL) (MD=0.93, 95%CI 0.05 to 1.80, P=0.04), implantation depth (ID) (MD=−2.06, 95%CI −2.96 to −1.16, P<0.01), the difference between MSL and ID (MD=3.05, 95%CI 1.92 to 4.18, P<0.01), and ID>MSL (OR=0.27, 95%CI 0.15 to 0.49, P<0.01) could be used as predictors of NOCAs. ConclusionCurrent evidence shows that age, chronic kidney disease, LBBB, MS, ID, the difference between MSL and ID, and ID>MSL could be used as predictors of NOCAs. Due to the limited quantity and quality of included studies, more high-quality studies are required to verify the above conclusion.
This paper reports a case of severe stenosis and calcification of functional bicuspid aortic valve treated with transcatheter aortic valve replacement (TAVR). Before the operation, echocardiography and multi-detector computed tomography were used to evaluate the ascending aorta, coronary artery, iliac artery anatomy, valve morphology, and valve calcification. During the operation, femoral artery perforation occurred after suturing the puncture site. The treatment of compression and hemostasis with peripheral balloon was performed. After the operation, neuropsychiatric symptoms appeared. The result of brain MRI indicated multiple acute cerebral infarction. Anticoagulant, antiplatelet, and neurotrophic drugs were used. After 1-year follow-up, echocardiography showed a little reflux signal around the artificial aortic valve, and the patient’s nervous system examination showed no obvious abnormality. TAVR indications will continue to expand in the near future with the innovation of evaluation, devices, and technology. The summary of operation data can promote progress of TAVR and reduce the occurrence of complications.
Objective To evaluate the early clinical effect of reimplantation in the treatment of bicuspid aortic valve (BAV) with aortic root aneurysm. Methods The clinical data of 25 patients with BAV and aortic root aneurysm[mean diameter: 45-63 (52.68±5.55) mm] undergoing reimplantation in West China Hospital from November 2019 to May 2021 were retrospectively reviewed. There were 22 males and 3 females. The mean age was 15-65 (50.00±13.10) years and body surface area was 1.79±0.23 m2. ResultsThe pathological classification of BAV malformation was confirmed during the operation: Type 0 in 3 patients and Type 1 in 22 patients. There were 12 patients undergoing cusp central plication, and 2 patients were sutured with a closed fusion crest. Postoperative valve leaflet coaptation height was 0.78±0.15 cm, and effective height was 1.27±0.19 cm. In operation, maximum aortic valve flow velocity was 1.65±0.42 m/s, pressure difference was 5.46±3.05 mm Hg, and aortic valve annulus diameter was 21.32±0.95 mm. Cardiopulmonary bypass time was 225.84±35.34 min, and aortic block time was 189.60±26.51 min. In-hospital time was 11.64±3.07 d, ICU stay time was 2.64±0.99 d, and mechanical ventilation time was 1.48±0.87 d. The follow-up time was 17.20±4.70 months, and no death or major complications occurred during the follow-up in all patients. The cardiac function of the patients significantly improved postoperatively (P≤0.05). Echocardiography suggested that 12 patients had no aortic regurgitation, 10 minor aortic regurgitation, 3 mild aortic regurgitation, and no patients with moderate or more severe regurgitation. The diameter of the aortic sinus, left ventricular end-diastolic diameter and volume decreased during the follow-up, compared to preoperative ones (P≤0.05). The maximum flow velocity of the aortic valve was 1.54±0.36 m/s, and the pressure difference was 5.17±2.38 mm Hg during the follow-up. ConclusionReimplantation technology has a good clinical effect for highly selective BAV patients. It can effectively avoid long-term postoperative anticoagulation, but the maximum flow rate after surgery is slightly increased, which may be related to the configuration of BAV itself. While compared with valve replacement, the effect is still worthy of recognition.
Patients with bicuspid aortic valve (BAV) are characterized by asymmetric anatomy, severe calcification and combined aortic dilatation. Compared with tricuspid aortic valve stenosis patients, patients with BAV stenosis confront with greater surgical risks in transcatheter aortic valve replacement (TAVR), including paravalvular leak, aortic valve rupture, coronary artery obstruction, atrioventricular block and so on. However, with the advent of new generation of prosthetic valves and optimization of surgical strategies, several studies have shown that TAVR is safe and effective in the treatment of BAV stenosis. Therefore, we aim to provide an overview of the use of TAVR in patients with BAV stenosis.