ObjectiveTo summarize the research progress in artificial metacarpophalangeal joint and interphalangeal joint prostheses.MethodsThe research literature on artificial metacarpophalangeal joint and interphalangeal joint prostheses at home and abroad was reviewed and summarized from anatomy, prosthesis design, and material development.ResultsThe artificial joint replacement can correct deformity, relieve pain, and improve function immediately. In the past 50 years, many researches have focused on the design and material of prostheses and surgical technique of joint replacement. There are three types of prostheses, including hinged limit-type-prosthesis, semi-limit-type-prosthesis, and non-limit-type-prosthesis. The prostheses have their own advantages and disadvantages, the long-term effectiveness of joint replacement is not ideal.ConclusionThe metacarpophalangeal joint and interphalangeal joint prostheses with more anatomical structure and biocompatible materials are needed.
ObjectiveTo report the preliminary clinical results and analyze the prognostic factors of prosthetic failures with non-cemented modular prosthetic reconstruction after tumor resection in lower extremities.MethodsA clinical data of 150 patients with lower extremity tumors treated with MEGASYSTEM-C non-cemented modular prosthetic reconstruction between October 2011 and September 2016 was retrospectively analyzed. There were 88 males and 62 females, aged from 12 to 81 years, with a median age of 24 years. According to World Health Organization (WHO) classification of bone tumors, 120 cases were primary malignant tumors, 27 cases were intermediate tumors, and 3 cases were metastatic tumors. Among them, 134 cases underwent primary operation and 16 cases underwent reoperation after recurrence. Eighty-seven patients with malignant tumors received chemotherapy before and after operation, and no patient received local radiotherapy during perioperative period. Proximal femur was reconstructed in 32 cases, distal femur in 83 cases, and proximal tibia in 35 cases. The postoperative follow-up time, the results of oncology (survival status and tumor recurrence), and prosthesis failure (prosthesis survival rate, reasons for failure, treatment plan after failure) were recorded. The reason of the prosthesis failure was classified into 5 types according to the classification defined by Henderson et al. Kaplan-Meier survival analysis and Log-Rank test were used to analyze patient and prosthesis survival. Lower extremity function was assessed by using the Musculoskeletal Tumor Society (MSTS) scoring system and MSTS scores were compared for patients with different reconstruction sites.ResultsAll patients were followed up 5-84 months, the median follow-up time was 39 months. During the follow-up period, there were 116 cases of tumor-free survival, 10 cases of tumor-bearing survival, and 24 died of lung metastasis or multiple metastases. The 3-year and 5-year survival rates of 120 patients with primary malignant tumors were 83.1% and 76.6%. There was no significant difference in survival rate between different reconstruction sites (P=0.851). Seven cases (4.7%) had local recurrence at 7-21 months after operation. The 3-year and 5-year survival rates of the prosthesis in 150 patients were 94.4% and 92.5%. There was no significant difference in survival rate between different reconstruction sites (P=0.765). There were 26 failures in 24 patients (16.0%) during the follow-up period. There were 9 cases of type 1 failure, 1 case of type 2 failure, 3 cases of type 3 failure, 5 cases of type 4 failure, and 8 cases of type 5 failure. At last follow-up, 120 of the 126 patients survived without prosthetic failure. Except that the influence of different parts of prosthesis on the incidence of type 4 failure (P=0.029), the influence of chemotherapy on the incidence of type 5 failure (P=0.002) were significant, the influence of other types of failure on different reconstructed parts of prosthesis, initial operation, and perioperative chemotherapy had no significant difference (P>0.05). There were 5 cases of amputation (4 cases of type 5 failure, 1 case of type 4 failure), 3 cases of prosthesis removal (1 case of type 2 failure, 1 case of type 3 failure, 1 case of type 4 failure), 3 cases of revision while keeping the original prosthesis (2 cases of type 1 failure, 1 case of type 5 failure). The overall MSTS score was 24±3. The MSTS scores were 24±3, 25±3, and 23±3 in patients whose reconstruction sites located in proximal femur, distal femur, and proximal tibia, respectively, showing no significant difference (F=3.014, P=0.052).ConclusionThe short-term follow-up showed a lower incidence of complications and good function for MEGASYSTEM-C non-cement modular prosthesis system in treatment of bone defects after lower limb tumor resection. The main factors affecting the early survival of prosthesis were tumor progression and infection.
Objective To discuss shortterm effect of rotating hinge knee prosthesis. Methods From July 2002 to April 2005, 17 cases of severe knee joint deformity and instability received rotating hinge knee prosthesis for total knee arthroplasty. There were 8 males and 9 females, aging from 41 to 79 years. The left joints were involved in 10 cases and right joint in 7 cases. All patients were admitted because of pain. The course of disease was from 1 to 7 years. There were 10 cases of osteoarthritis,5 cases of rheumatoid arthritis,1 case of traumatic arthritis after operation of left femur fracture,and 1 case of traumatic arthritis with injury of anterior cruciate ligament, meniscus medialis and medial collateral ligament after operation of left fracture of tibial plateau. According to HSS(hospital for special surgery) scoring system,the preoperative score was 36 to 58 with an average of 48.6. The preoperative flexed motion range of articulation was 21° to 80° with an average of 57.4°. Results All patients were followed up from 7 months to 3 years with an average of 23.6 months. There were no complications of thrombogenesis of veins of lower extremity, pulmonary embolism, palsy of peroneal nerve, fracture, and breakage of extended knee structure. Infection occurred in 1 case at 3 months postoperatively,the prosthesis was dislodged,antibiotic-impregnated cement was filed with knee joint,twostage arthroplasty was expected. At the last follow-up,the HSS score was 78 to 98 with an average of 91.1 in 16 patients. The flexed motion range of articulation was 75° to 100° with an average of 852° at 2 weeks postoperatively. The flexed motionrange of articular was 85° to 123° with an average of 1083° at the last followup. There were significant differences in HSS score and motion range of articular between preoperation and thelast follow-up (P<0.05). Conclusion The short-term outcome of rotating hinge knee prosthesis is good and a long term followup is necessary.
ObjectiveTo summarize the recent progress in prevention of prosthetic joint infection (PJI) so as to provide clinical references. MethodsThe publications concerning the etiology and surgical management of PJI were reviewed, analyzed, and summarized. ResultsThe prevention of PJI is related to preoperative, intraoperative, and postoperative aspects of PJI, comprehensive treatment is considered to be the most common method for PJI. ConclusionThese prevention strategies that may be utilized in all phases of perioperative care, a multifaceted approach to the patient undergoing total joint replacement will have the greatest positive effect
Abstract The fracture of the prosthetic stem after prosthetic replacement of femoral head is not rare. In this study, the photoeastic instrument was used to study the stress distribution on the prosthetic stem following its insertion and to analyse the factors influencing the fracture of the stem. Through the examination of 9 places in 8 cases, it was found that:(1) The removal of femoral calcar and the inframedullary filling of the bone cement directly influenced the stress distribution. (2) The valgus or varus condition of the prosthesis would lead to stress concentration on the stem. (3) Once lossening of the prosthesis occured it would change the preliminary installingstress distribution in the upper femur which would lead to fatigue fracture. Ths experimental data and clinical observation would provide scientific basis forthe prevention of fracture of prosthetic stem following prosthetic replacement of femoral head.
In order to evaluate the long-term effect of total hip replacement (THR) in patients with steroid-induced femoral head necrosis, 40 cases of 50 hips received THR patients were followed up for an average of 8.5 years after operation. Evaluation was carried act according to Harris score system. In these cases, average score was seventy-five points. Revision rate among them was 2% after four years and 18% after five to eight and a half years, with as overall rate of 20%. It was found that the main reason for revision was looseness of the prosthesis. In this follow-up, it showed that besides foreigen body reaction, abnormal osseous remodelling was the main factor in long-term failure of this arthroplasty. It was also proved that it was a good selection to perform cemented total hip replacement in younger patients, which could improve living quality.
Objective To summarize the clinical outcome of the Ribbed anatomic cementless total hip arthroplasty (THA) in the treatment of hip-joint disease. Methods From January 2001 to June 2005, 34 patients(38 hips) with hip-joint disease were treated with Ribbed anatomic cementless THA. Their ages ranged from 29 to 55 years with an average age of 42.7 years.The disease course was from 3 to 18 years. Among these cases, there were 7 cases (7 hips) of femoral neck fracture, 5 cases(5 hips) of traumatic arthritis after fracture of acetabulum, 15 cases(16 hips) of necrosis of the femoral head and 7 cases(10 hips) of ankylosing spondylitis. Four patients were operated on both hip joints. The average Harris hip score was 38.6(25-57) before operation. Results Twenty-one patients(23 hips) were followed up 861 months with an average of 35 months. The Harris hip score was 76-98 after operation with an average of 92.3, showing significant difference when compared with that before operation(Plt;0.05). The excellent and good result was achieved in 93.5 % of patients. Radiographs showed no prosthetic osteolysis and no evidence of loosening. Pain in the thigh occurred in 4 patients,and it can be relieved by using nonsteroid antiinflammatory drug. Conclusion Ribbed anatomic cementless THA has good clinical and radiographic results in treating patients with hip-joint disease.