ObjectiveTo evaluate the effectiveness of the modified intramedullary fixation with two Kirschner wires for extra-articular fracture of the proximal phalangeal base. MethodsBetween June 2012 and November 2015, 18 cases (18 fingers) of fresh extra-articular fracture of the proximal phalangeal base were treated, including 16 males and 2 females with an average age of 31 years (range, 21-57 years). The causes included strike injury in 10 cases, fall injury in 4 cases, mechanical injury in 1 case, twist injury in 1 case, crush injury in 1 case, and cutting injury in 1 case. The injured fingers were little finger in 16 cases, ring finger in 1 case, and index finger in 1 case. Of the 18 cases, 17 had closed fractures and 1 had open fracture. X-ray film showed transverse fracture in 14 cases and transverse-oblique fracture in 4 cases. The time between injury and operation was 3 hours to 4 days (mean, 2 days). After anatomical reduction, two Kirschner wires were used for intramedullary fixation. Functional exercises were done at 2 days after operation. The Kirschner wires were removed at 4 weeks after operation. ResultsAll the wounds healed by first intention. There were no deformation, loosening or breakage of Kirschner wires, and pin tract infection. Postoperative X-ray films showed anatomical reduction of fracture in all cases; no re-displacement happened, and clinical healing was obtained at 4 weeks; bony union was obtained at 8 weeks. All patients were followed up 6-12 months with an average of 8 months. There was no pain in the metacarpophalangeal joint; the range of motion was (88.1±2.3)° at 3 months after operation, showing no significant difference when compared with normal side [(88.8±2.6)°] (t=1.73, P=0.10). The finger flexion and extension were normal; according to the criteria of total active motion of finger, the results were excellent in all cases. ConclusionThe technique of modified intramedullary fixation with two Kirschner wires for extra-articular fractures of the proximal phalangeal base has the merits of convenient operation, little injury, reliable fixation, and excellent effectiveness. This technique is conducive to the recovery of hand function due to the early functional exercises.
Objective To summarize the effectiveness of Kirschner wire buckling combined with bone fixation in the treatment of metacarpal avulsion fracture. Methods The clinical data of 35 patients of metacarpal avulsion fracture admitted between March 2017 and June 2022 were retrospectively analyzed. There were 22 males and 13 females; the age ranged from 20 to 55 years, with an average of 31.6 years. There were 17 cases of the second metacarpal avulsion fracture, 6 cases of the fourth metacarpal avulsion fracture, and 12 cases of the fifth metacarpal avulsion fracture. The causes of injury included 21 cases of strangulation, 8 cases of sprain, and 6 cases of sports injury. X-ray film examination showed that the size of the avulsion fracture of metacarpal bone ranged from 0.30 cm×0.20 cm to 0.55 cm×0.45 cm. The total active motion (TAM) of the injured finger before operation was (154.00±17.38)°. The time from injury to operation was 3-10 days, with an average of 5.8 days. Follow-up regularly after operation, X-ray film and CT examination were performed to evaluate fracture healing and TAM of injured finger was measured. The finger function was evaluated by the trial standard of upper limb function evaluation of Hand Surgery Society of Chinese Medical Association. Results All the incisions healed by first intention. All 35 patients were followed up 9-36 months, with an average of 28 months. All metacarpal avulsion fractures achieved bony healing, and the healing time was 4-6 weeks, with an average of 4.8 weeks. The metacarpophalangeal joint of the patient was stable, without stiffness, and the flexion and extension activities were good. At last follow-up, the TAM of the injured finger reached (261.88±6.23)°, which was significantly different from that before operation (t=−35.351, P<0.001). The finger function was evaluated according to the trial standard of upper limb function evaluation of the Society of Hand Surgery of Chinese Medical Association, and 33 cases were excellent and 2 cases were good, with an excellent and good rate of 100%. Conclusion The treatment of metacarpal avulsion fracture with Kirschner wire buckling combined with bone fixation has the advantages of less trauma, firm fixation, and less interference to the soft tissue around metacarpophalangeal joints, which is a good alternative method for the metacarpal avulsion fracture.
目的 比较克氏针张力带与锁骨钩钢板治疗RockwoodⅢ型肩锁关节脱位的临床疗效。 方法 1999年1月-2007年3月,收治肩锁关节脱位患者29例,分别采用克氏针张力带联合喙锁韧带重建(克氏针组10例)和锁骨钩钢板(钢板组19例)治疗。其中男18例,女11例;年龄19~50岁,平均38.2岁。患者均为新鲜RockwoodⅢ型肩锁关节脱位,受伤至手术时间1~16 d,平均3 d。两组患者性别、年龄、受伤至手术时间等一般资料比较差异无统计学意义(P>0.05)。进行两组患者术后临床及影像学评估比较。 结果 25例患者(克氏针组10例,钢板组15例)获随访,随访时间2~12年,平均6年。术后克氏针组发生克氏针弯曲5例、断裂1例;钢板组切口浅表感染2例,经换药后治愈,其余患者切口Ⅰ期愈合。两组患者肩锁关节均获得良好功能,组间比较差异无统计学意义(P>0.05)。影像学方面:与克氏针组相比,在患肢负重位时钢板组喙锁间隙间距增加了23%(P<0.05),非负重位两组间距差异无统计学意义(P>0.05)。术后8~12周出现喙锁韧带钙化,钢板组12例、克氏针组2例(P<0.05)。术后6个月出现肩锁关节骨性关节炎,钢板组2例、克氏针组1例(P>0.05)。肩关节功能与影像学结果无相关性(r=0.096,P>0.05)。 结论 克氏针张力带联合喙锁韧带重建和锁骨钩钢板固定治疗RockwoodⅢ型肩锁关节脱位均可获得良好的临床功能。与克氏针张力带相比,锁骨钩钢板固定具有手术操作简便、疗效确切、并发症少、能够早期康复锻炼等优点。
Objective To investigate the effectiveness of arthroscopy-assisted combined fixation of Kirschner wire and external fixator for treating extreme distal radial fractures. Methods Between January 2014 and May 2016, 21 patients who suffered from extreme distal radial fractures were treated by arthroscopy-assisted combined fixation of Kirschner wire and external fixator. There were 14 males and 7 females with an age of 32-57 years (mean, 42.3 years). The causes of injury included falling in 13 cases and traffic accident in 8 cases. The fracture type included 8 cases of type 23C1, 9 cases of type 23C2, and 4 cases of type 23C3 according to AO/OTA classification. The time from injury to operation was 3-7 days (mean, 4.4 days). The Mayo score and disability of arm, shoulder, and hand (DASH) score were used to assess the pain and function of the wrist joint. Results There was no needle red swelling, tendon irritation, or orther early complications. All the patients were followed up 10-35 months (mean, 18.3 months). The fracture healing time was 9-13 weeks (mean, 10.6 weeks). At last follow-up, the Mayo score was 87-94 (mean, 90.9); and 17 cases were excellent and 4 were good. The DASH score was 7-13 (mean, 10.6). Conclusion Arthroscopy-assisted combined fixation of Kirschner wire and external fixator for treating extreme distal radial fractures has the advantages of firm fixation, early functional exercise, less postoperative complications, and good functional recovery of wrist joint.
Objective To compare the effectiveness of suspension fixation plus hinged external fixator with double plate internal fixation in the treatment of type C humeral intercondylar fractures. Methods Between January 2014 and April 2016, 30 patients with type C (Association for the Study of Internal Fixation, AO/ASIF) humeral intercondylar fractures were treated. Kirschner wire suspension fixation plus hinged external fixator was used in 14 cases (group A), and double plate internal fixation in 16 cases (group B). There was no significant difference in gender, age, injury cause, disease duration, injury side, and type of fracture between 2 groups (P>0.05). Results There was no significant difference in operation time and hospitalization stay between 2 groups (P>0.05). But the intraoperative blood loss in group A was significantly less than that in group B (P<0.05); the visual analogue scale (VAS) score at 1 day and 3 days after operation in group A were significantly less than those in group B (P<0.05). Primary healing of incision was obtained in all patients of 2 groups, and no surgery-related complications occurred. The patients were followed up 6-24 months (mean, 12.3 months) in group A and 6-24 months (mean, 12.8 months) in group B. The self-evaluation satisfaction rate was 85.7% (12/14) in group A and was 81.2% (13/16) in group B at 3 months after operation, showing no significant difference (χ2=0.055, P=0.990). Based on the improved Gassebaum elbow performance score at 6 months after operation, excellent and good rate of the elbow function was 78.6% (excellent in 5 cases, good in 6 cases, fair in 2 cases, and poor in 1 case) in group A and was 81.2% (excellent in 6 cases, good in 7 cases, fair in 2 cases, and poor in 1 case) in group B, showing no significant difference between 2 groups (χ2=0.056, P=0.990). Heterotopic ossification occurred at 3 months after operation in 1 case of each group respectively. The X-ray films showed bony union in all cases; no loosening or breakage of screw was observed. The bone union time showed no significant difference between 2 groups (t=–0.028, P=0.978). The time of internal fixation removal, the intraoperative blood loss, and VAS score at 1 day and 3 days after operation in group A were significant better than those in group B (P<0.05). Conclusion The suspension fixation plus hinged external fixator and double plate internal fixation for the treatment of type C humeral intercondylar fractures have ideal outcome in elbow function. But the suspension fixation plus hinged external fixator is better than double plate internal fixation in intraoperative blood loss, postoperative VAS score, and time of internal fixation removal.