west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "共焦" 17 results
  • Expression of Nogo receptor in rats′ retina during the postnatal development

    Objective To observe the expression of Nogo66 receptor (NgR)in ratsprime; retina during the postnatal development. Methods The expression of NgR in 48 rats were observed by immunofluorescence histochemistry and laserconfocal microscopy 0, 3, 7, 14, 21, 35, 49, 63 days after birth, with 6 rats in each group, respectively. Results The expression of NgR is positive in the retina in the whole duration of growth, and the fluorescence pigmentation was located around the ganglion cell nuclaear. Conclusion The positive expression of NgR suggests that the interaction of NgR and CNS myelin inhibitors not only inhibit neuronal plasticity but also promote it, which could regulate neuronal plasticity.

    Release date:2016-09-02 05:48 Export PDF Favorites Scan
  • The application of confocal scanning laser tomography in age-related macular degeneration

    Objective To verify the applicable significance of confocal scanning laser retinal tomography in agerelated macular degeneration (AMD). Methods Heidelberg confocal scanning laser tomography was used to measure 75 eyes of 59 patients with AMD, including 25 eyes of 20 patients with exudative AMD, 25 eyes of 16 patients with atrophic AMD, and 25 eyes of 23 patients with macular drusen. The differences of the width, volume and maximum height of Z profile signal of macula were analyzed. Results Z profile signal width in macular tomography of exudative AMD was wider than that of macular drusen; maximum height and volume in macular tomography of exudative AMD were larger than that of macular drusen (P<0.01); Z profile signal width, maximum height,and volume in macular tomography of atrophic AMD were wider and larger than that of macular drusen (P<0.05). Macular volume of exudative AMD was obviously larger than that of atrophic AMD (P<0.01). Conclusion Confocal scanning laser tomography may be one of the useful methods for objective evaluation of morphologic change for the development of AMD. (Chin J Ocul Fundus Dis, 2002, 18: 262-265)

    Release date:2016-09-02 06:01 Export PDF Favorites Scan
  • Comparison of confocal laser scanning colorful fundus imaging and color fundus photography for detection of diabetic retinopathy

    ObjectiveTo compare the imaging characteristics and detection of various types of lesions in diabetic retinopathy (DR) with colorful laser scanning fundus imaging (MSLI) and traditional color fundus photography (CFP).MethodsProspective case series observational study. A total of 38 eyes of 38 patients with DR diagnosed by clinical examination were included in the study. Among them, 21 were male and 17 were female; the mean age was 62.6±11.2 years; the average duration of diabetes was 14.3±7.5 years. All the patients were performed CFP, MSLI, frequency domain optical coherence tomography (SD-OCT), fluorescein angiography (FFA) examination. Using the Helielberg Spectralis HRA+OCT MSLI inspection, one scan simultaneously obtained 488 nm blue reflection (BR), 515 nm green light reflection (GR), 820 nm infrared light reflection (IR), and multicolor image (MC). The detection of traditional CFP and MC on microaneurysm (MA), hard exudation (HEX), cotton plaque (CWS), intraretinal hemorrhage (IRH), intraretinal microvascular abnormality (IRMA), venous bead (VB), venous ring (VL), macular edema (DME), macular anterior membrane (MEM) and laser photocoagulation (LB) were comparatively observed. The results of FFA examination were used as the diagnostic criteria for lesions. SD-OCT was used to determine the location and depth of lesions and the diagnostic reference for DME and MEM.ResultsThe numbers of eyes with MA (χ2=10.460), DME (χ2=4.006), MEM (χ2=4.444) was significantly higher in MC than that of traditional CFP. But the number of eyes with IRH (χ2=0.103), CWS (χ2=1.515), HEX (χ2=0.227), IRMA (χ2=0.051), VB (χ2=0.001), VL (χ2=0.149), VH (χ2=0.693) and LB (χ2=0.720) were not statistically significant between two methods (P>0.05). The imaging quality of MSLI mode is obviously better than that of traditional CFP. Among them, GR imaging shows the best structural changes of superficial retina in MA, CWS, HEX, MEM, etc. IR imaging shows clear depth in deep retina such as LB. DME was green on MC and the weak low-reflection dark area was visible on the IR image, which were consistent with the DME range indicated by the SD-OCT examination.ConclusionsCompared with the traditional CFP, the MSLI can clearly show the DR lesion. The number of checkouts is high on MA, DME and MEM by MC image.

    Release date:2018-07-23 04:02 Export PDF Favorites Scan
  • The clinical observation of the relationship between the macular pigment and the foveal cone function

    Objective To test the hypothesis that the macular pigment may be a marker of foveal cone function and consequently the structural integrity of foveal cones.Methods Sixteen patients (32 eyes) diagnosed to have Stargardt dystrophy and three patients with full thickness macular holes by clinical criteria were studied with a scanning laser ophthalmoscopy (SLO) comparing argon laser blue and infrared images for the presence or absence of macular pigment (MP) in the fovea. An C++ computer based program was used to evaluate the density of MP. Eyes were graded into three categories: those without foveal macular pigment, those with partial pigment and those with normal amounts of macular pigment. These categories were compared with visual acuity determined by the Snellen chart. Results Thirteen eyes with a visual acuity of 20/200 or worse had no macular pigment in the fovea. Eleven eyes with visual acuity of 20/40 or better had a normal amount of macular pigment in the fovea and 1 eye had partial macular pigment. Eleven eyes with partial macular pigment had intermediary acuity value.Conclusions Foveal macular pigment is closely related to foveal cone acuity and therefore may be a marker for the presence of foveal cones. Infrared light is a sensitive indicator of early macular diseases.(Chin J Ocul Fundus Dis,2003,19:201-268)

    Release date:2016-09-02 06:00 Export PDF Favorites Scan
  • 海德堡视网膜断层扫描仪在青光眼诊断中的应用

    视盘形态学改变是青光眼早期征象,可出现在视野缺损之前。青光眼视盘改变主要表现有视网膜神经纤维层受损、盘沿面积的缩小和杯形的改变等。海德堡视网膜断层扫描仪检查可及时、无创伤地获得视盘三维图像,并可定量分析和随访青光眼视盘改变。现介绍其原理及在青光眼诊断和随访中的应用。 (中华眼底病杂志, 2002, 18: 250-252)

    Release date:2016-09-02 06:01 Export PDF Favorites Scan
  • 孤立性视网膜星状细胞错构瘤多波长炫彩和光相干断层扫描血管成像观察一例

    Release date:2019-01-19 09:03 Export PDF Favorites Scan
  • Reproducibility of Heidelberg retinal tomograph measuring the macular retinal thickness

    ObjectivesTo evaluate the reproducibility of Heidelberg retina tomograph (HRT) macular edema module(MEM) measuring the macular retinal thickness.MethodsSixty-two healthy volunteers (9-68 years old) were examined by HRT-II procedure. The retinal signal width (SW) at macula and fovea and macular edema index (E) were recorded for t-test, Pearson linear-correlation analysis. Intra-subject variation repeatedly measured was analyzed with coefficient of variation, 95% tolerance limits of change (TC), and intraclass coefficient of correlation (ICC). ResultsIn healthy individuals, retinal SW was (0.734±0.236) mm at macula,and (0.781±0.243) mm at fovea; macular E was (1.169±0.619). The coefficient of variation repeatedly measured: retinal SW was (8.7±68)%,retinal SW at the fovea was (8.5±6.7)%, and the average was (15.6±13.9)%; 95%TC of intra-subject sequential repeated measurement was 0.131 (8.9%) of retinal SW, 0.137 (10.5%)of fovea SW,and 0.198 (7.4%) of average E. ICC of one individual repeatedly measured by one operator was 0.950 of macular SW, 0.949 of fovea SW, and 0.898 of average edema index.ConclusionsHRT-II MEM is noninvasive, fast and highly reproducible, which provides a new technique to monitor the objective quantification of macular diseases related to retinal thickness. ( Chin J Ocul Fundus Dis, 2005,21:103-105)

    Release date:2016-09-02 05:52 Export PDF Favorites Scan
  • Analysis of the positive rate of scanning laser ophthalmoscope in the retromode for different types of diabetic macular edema

    Objective To explore the positive rate of scanning laser ophthalmoscope in the retromode (RM-SLO) in different types of diabetic macular edema (DME), and to analyze its correlation with foveal thickness (CMT) and macular volume. MethodsFrom March to May 2021, 40 patients (65 eyes) were diagnosed as DME by fundus examination combined with optical coherence tomography (OCT) in Affiliated Eye Hospital of Wenzhou Medical University at Hangzhou were included in the study. All eyes underwent best corrected visual acuity (BCVA), OCT and RM-SLO fundus imaging examinations, 47 eyes underwent fluorescein fundus angiography (FFA) examination. RM-SLO fundus imaging examinations were performed with Mirante SLO, including retro mode illumination deviated right (RMDR) and retro mode illumination deviated left (RMDL). If one or more of the RMDR and RMDL of the examined patient can identify macular edema, RM-SLO was considered to be able to identify macular edema. The macular volume at CMT and 6 mm from the fovea was measured by OCT software. DME were divided into 3 types based on OCT images: diffuse retinal thinkening (DRT) type; cystoid macular edema(CME) type; serous retinal detachment (SRD) type, focal leakage type, diffuse leakage type and diffuse cystic leakage type. The consistency of RMDR and RMDL in the diagnosis of DME in RM-SLO fundus imaging was evaluated, as well as their positive rate in different classifications of DME. The correlation between the detection of macular edema by RM-SLO and the DME type, CMT and foveal volume, and the correlation between BCVA and edema type, CMT and macular volume were analyzed. ResultsAmong 65 eyes, the positive rates of RMDR and RMDL fundus imaging to detect DME were 46 (70.77%, 46/65) and 48 (73.85%, 48/65), respectively. There was good consistency in identifying DME (Kappa value=0.770; P<0.001). The positive rates of RMDR and RMDL fundus imaging DRT, CME and SRD type of DME were 42.11% (8/19), 57.89% (11/19), 77.78% (28/36), 77.78% (28/36), 100.00% (10/10), 90.00% (9/10), respectively. In the FFA classification of them, the positive rates of focal leakage, diffuse leakage and diffuse cystic leakage were 68.75% (11/16), 62.50% (10/16), 68.00% (17/25), 76.00% (19/25), 100.00% (6/6), 100.00% (6/6), respectively. The results of Spearman correlation analysis showed that whether RM-SLO could identify DME was associated with CMT and OCT classification (r=0.310, 0.365; P=0.120, 0.003); there was no correlation between FFA classification and macular volume (r=0.113, 0.117; P=0.449, 0.352). BCVA was correlated with CMT and macular volume (r=0.307, 0.269; P=0.013, 0.030), however, there was no significant correlation with OCT type, angiographic type (r=0.051, 0.175; P=0.684, 0.240). ConclusionThe diagnostic agreement of DME are good between RMDR, RMDL of RM-SLO image. DME of DRT type and patients with smaller CMT in OCT are difficult to identified by RM-SLO fundus imaging.

    Release date:2022-12-16 10:13 Export PDF Favorites Scan
  • Give full play to the clinical application value of confocal scanning laser ophthalmoscope imaging to improve the diagnosis of ocular fundus diseases

    Confocal scanning laser ophthalmoscope imaging superimpose two or three kinds of lasers to obtain images of different layers of retina, and then synthesize a pseudo-color fundus image by computer. Confocal scanning laser ophthalmoscope is widely used in outpatient fundus pre-examination and epidemiological screening of large samples due to its features of non-mydriatic, fast imaging, simple operation and high degree of patient cooperation. It has good clinical and scientific application value in the diagnosis and treatment of a variety of fundus diseases. Because of there is still a lack of unified standards for laser fundus photos in China, it is necessary to correctly identify the common fundus lesions in confocal scanning laser ophthalmoscope and to summarize and popularize the method of reading the photos in layers. In addition, we should give full play to the its advantage of layering and locating, and reasonably choose the combination of OCT, OCT angiography, FFA, ICGA, ultrasonography, so as to maximize its clinical application value and help clinical diagnosis.

    Release date:2020-06-23 07:44 Export PDF Favorites Scan
  • The clinical applications of adaptive optics scanning laser ophthalmoscope

    Adaptive optics (AO) is a technique to improve the performance of optical systems by reducing the influence of optical aberrations. Combined with scanning laser ophthalmoscope (AOSLO), the aberration of human refractive system can be corrected. Thus, the resolution and quality of imaging can be greatly improved to the cellular level in vivo retina (such as photoreceptor, nerve fibers, vascular parietal cell), therefore the earlier changes of the diseases can be detected. At the same time, microstructure changes of retinal can also be observed during the follow-up of the disease. Due to inherent technical defects of AOSLO, its wide application in clinical practice is limited. With the continuous progress of AO technology and the further improvement of related software functions, the function of the system will become more stronger and will play a more and more important role in scientific research and clinic.

    Release date:2020-01-11 10:26 Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content