Objective To compare the postoperative anorectal pressure after procedure for prolapse and hemorrhoids (PPH) and Milligan-Morgan hemorrhoidectomy (MMH) in treatment of patients with mixed hemorrhoid of Ⅲ-degree. Methods In total of 112 patients with mixed hemorrhoid of Ⅲ-degree who underwent PPH (n=60) or MMH (n=52) in The First Affiliated Hospital of Xinjiang Medical University between March 2014 to March 2015 were prospectively enrolled, the type of surgery was according to patients’ individual choice. In 6 months after operation, all patients under-went the examination of anorectal manometry which including rectal anal inhibitory reflex, rectal resting pressure, anal resting pressure, maximal anal contractive pressure, and anal canal length of high pressure belt. Results In 6 months after operation, the positive rate of rectal anal inhibitory reflex 〔88.3% (53/60) vs. 61.5% (32/52)〕 , anal resting pressure 〔(56.42± 2.25) mm Hg vs. (46.31±2.58) mm Hg〕, and anal canal length of high pressure belt 〔(3.35±0.12) cm vs. (2.29±0.23) cm〕 of PPH group were all significantly higher than those of MMH group (P<0.05), but there was no statistical significance between PPH group and MMH group in rectal resting pressure 〔(5.51±1.26) mm Hg vs. (5.39±1.85) mm Hg〕 and maximal anal contractive pressure 〔(156.64±9.78) mm Hg vs. (155.32±8.53) mm Hg〕, P>0.05. Conclusion PPH and MMH are all effective to treat mixed hemorrhoids of Ⅲ-degree, but PPH is more positive in protection of anal function.
ObjectiveTo explore the clinical efficacy and safety of ligation of intersphincteric fistula tract in the treatment of high simple anal fistula.MethodsA prospective collection of 72 patients diagnosed with high simple anal fistula, who admitted to the department of the author’s hospital between March 2015 and December 2017 was performed, and then the patients were divided into two groups according to the random number table method combined with the patients’ wishes: the ligation of intersphincteric fistula tract group (experimental group, 32 cases) and the low incision and high hanging group (control group, 40 cases). Comparison of indexes on the operative effect and physiological function of the sphincter in six months after operation was performed.ResultsCompared with the control group, the patients in the experimental group had short postoperative pain duration, short postoperative wound healing time, high cure rate, low recurrence rate, low initial sensory threshold, high anal resting pressure, and long anal high pressure band length, with statistically significant differences (P<0.05). However, there was no statistically significant difference between the two groups in the operation time, anal maximal contractive pressure, and rectal resting pressure (P>0.05). The results suggested that the physiological function of anus in the experimental group recovered well.ConclusionThe ligation of intersphincteric fistula tract is a safe and reliable method in the treatment of high simple anal fistula, which can be widely used in the clinic.
Objective To observe the incidence rate of cardiovascular adverse events and evaluate the safety of dexmedetomidine or midazolan sedation in patients with long-term mechanical ventilation in intensive care unit (ICU). Methods From January 2014 to December 2015, patients admitted to ICU aged ≥18 years with mechanical ventilation time ≥48 hours were randomly divided into dexmetomidine group (group D) and midazolam group (group M). Adverse events such as cardiovascular events during sedation were observed. Results There were 144 cases in group D and 143 cases in group M. Slow heart rate was the prominent manifestation in group D. The incidence of heart rate <50 beats per minute in group D (4.86%) was less than that in group M (6.29%), but there was no statistical difference ( P=0.681). Group D had lower blood pressure (40.28% vs. 72.73%), tachycardia (18.75% vs. 41.96%), arrhythmia (16.67% vs. 34.97%) and 28- day mortality (22.22% vs. 42.66%) than those in group M (P<0.01). No cardiac arrest, sinus arrest, hypertension, hyperglycemia, or hypoglycemia were found in the two groups. Conclusion The long-term sedation of dexmetidine in patients with mechanical ventilation is safe; in cardiovascular adverse events, the 28-day mortality is lower than that of traditional midazolam sedation, and the duration of mechanical ventilation is no longer than that of traditional midazolam sedation, with slightly longer ICU length of stay.
ObjectiveTo compare the ascending aortic diameter and postoperative outcomes of patients with simple ascending aortic dissection or simple ascending aortic dilatation and to study the reliability of the surgical indication in present guideline for Chinese patients with ascending aortic dilatation.MethodsThe clinical data of patients with aortic aneurysm and aortic dissection who underwent surgery at Beijing Anzhen Hospital, Capital Medical University from 2010 to 2017 were retrospectively reviewed. After exclusion of patients with Marfan syndrome, heart valve and other diseases, 139 patients were divided into two groups: a simple ascending aorta dilatation group (56 patients) and a simple ascending aortic dissection group (83 patients). The ascending aortic diameter and postoperative outcomes of two groups were compared. ResultsThe inner ascending aortic diameter (57.30±9.41 mm vs. 50.72±9.53 mm, P <0.001) and the inner ascending aortic diameter index (31.12±5.38 vs. 27.22±6.40, P<0.001) in the simple ascending aorta dilatation group were significantly greater than those in the simple ascending aortic dissection group. For male patients, the results were similar (60.28±10.80 mm vs. 47.40±6.53 mm; 30.00±6.33 vs. 23.60±3.72, both P<0.001). But for the female patients, there was no significant difference between the two groups (54.90±7.47 mm vs. 53.81±10.84 mm; 32.03±4.37 vs. 30.58±6.56, both P>0.05). The mortality, the incidence of tracheotomy and postoperative reopen rate in the simple ascending aortic dissection group were higher.ConclusionIn this study, the inner diameter of the ascending aorta in the group of ascending aorta is mostly < 5.5 cm. In our opinion, the present surgical indication for Chinese patients with ascending aortic dilatation is not enough. In the future clinical studies, we also need to find more reasonable surgical indications.
ObjectiveTo explore the effect of body mass index (BMI) on the outcomes of laparoscopic surgery for esophageal hiatal hernia.MethodsWe divided the patients who underwent hiatal hernioraphy and fundoplication surgery in our hospital between July 2013 and June 2018 into two groups according to the BMI: a group A, BMI ≥24 kg/m2, 77 patients, 41 males, 36 females, with an average age of 42 years; a group B: BMI<24 kg/m2, 63 patients, 38 males, 25 females, with an average age of 67 years, and the age, gender, type of hiatal hernia, score of subjective feeling of symptoms, level of reflux esophagitis were analyzed with the propensity score matching method. Fifty one patients were successfully matched in each group, and the curative effect of surgery was compared between the two groups.ResultsThere was no statistical difference in the type of surgery, intraoperative complications, postoperative complications, and hospital stay between the two groups (P>0.05). The operative time of the group A was significantly longer than that of the group B (P=0.023). There was no statistical difference between the two groups in postoperative recurrence (P=0.741).ConclusionThe operative time in overweight patients is significantly longer than that in the non-overweight patients, but it has no effect on the surgical outcomes and complications.
Arrhythmia is a significant cardiovascular disease that poses a threat to human health, and its primary diagnosis relies on electrocardiogram (ECG). Implementing computer technology to achieve automatic classification of arrhythmia can effectively avoid human error, improve diagnostic efficiency, and reduce costs. However, most automatic arrhythmia classification algorithms focus on one-dimensional temporal signals, which lack robustness. Therefore, this study proposed an arrhythmia image classification method based on Gramian angular summation field (GASF) and an improved Inception-ResNet-v2 network. Firstly, the data was preprocessed using variational mode decomposition, and data augmentation was performed using a deep convolutional generative adversarial network. Then, GASF was used to transform one-dimensional ECG signals into two-dimensional images, and an improved Inception-ResNet-v2 network was utilized to implement the five arrhythmia classifications recommended by the AAMI (N, V, S, F, and Q). The experimental results on the MIT-BIH Arrhythmia Database showed that the proposed method achieved an overall classification accuracy of 99.52% and 95.48% under the intra-patient and inter-patient paradigms, respectively. The arrhythmia classification performance of the improved Inception-ResNet-v2 network in this study outperforms other methods, providing a new approach for deep learning-based automatic arrhythmia classification.
ObjectiveTo review research progress on the design, manufacturing, and clinical application of three-dimensional (3D) printed customized prosthesis in acetabular reconstruction of hip revision surgery. MethodsThe related research literature on 3D printed customized prosthesis and its application in acetabular reconstruction of hip revision surgery was searched by key words of “3D printed customized prosthesis”, “revision hip arthroplasty”, “acetabular bone defect”, and “acetabular reconstruction” between January 2013 and May 2024 in Chinese and English databases, such as CNKI, Wanfang database, PubMed, etc. A total of 34 271 articles were included. After reading the literature titles, abstracts, or full texts, the literature of unrelated, repetitive, low-quality, and low evidence level was screened out, and a total of 48 articles were finally included for analysis and summary. ResultsThe bone growth and mechanical properties of 3D printed customized prosthesis materials are better than those of non-3D printed customized prosthesis, which further solves the problem of elastic modulus mismatch between the implant and natural bone caused by “stress shielding”; the porous structure and antibacterial coating on the surface of 3D printed customized prosthesis have good anti-bacterial effect. 3D printed customized prosthesis can perfectly match the patient’s individual acetabular anatomical characteristics and defect type, thus improving the accuracy of acetabular reconstruction and reducing the surgical time and trauma. Conclusion3D printed customized prosthesis can be used for precise and efficient individualized acetabular reconstruction in hip revision surgery with good early- and mid-term effectiveness. More optimized production technics and procedures need to be developed to improve the efficiency of clinical application and long-term effectiveness.
ObjectiveTo evaluate the advantages and disadvantages of patch aortoplasty and extended side-to-end anastomosis for the treatment of coarctation of the aorta (CoA) and hypoplastic aortic arch, and provide a more reasonable surgical choice. MethodsClinical data of 45 patients who underwent surgical correction for CoA and hypoplastic aortic arch in Beijing Anzhen Hospital from June 2008 to June 2013 were retrospectively analyzed. According to different surgical strategies for aortic arch hypoplasia, all the 45 patients were divided into 2 groups. In group I, there were 26 patients including 15 males and 11 females with their age of 0.5-6.8 (0.9±2.5) years and body weight of 5.0-20.3 (9.5±7.3) kg, who received patch aortoplasty and whose preoperative pressure gradient between right upper and lower limbs was 38.3±15.6 mm Hg. In groupⅡ, there were 19 patients including 14 males and 5 females with their age of 0.6-7.5 (1.0±2.7) years and body weight of 5.5-21.5 (10.2±6.6) kg, who received extended side-to-end anastomosis and whose preoperative pressure gradient between right upper and lower limbs was 40.7±16.1 mm Hg. Postoperative changes of pressure gradient between right upper and lower limbs of the 2 groups were examined and compared with preoperative values. ResultsTwo patients died postoperatively (4.4%) including 1 patient with low cardiac output syndrome and the other patient with severe lung infection. None of the patients in either group had renal failure or neurological complications. Postoperatively, there were 28 patients whose systolic blood pressure (SBP) of lower extremities was 10-20 mm Hg higher than that of upper extremities, 13 patients whose SBP gradient between upper and limbs was less than 10 mm Hg, and 4 patients whose upper limb SBP was 20 mm Hg higher than lower limb SBP. Postoperative average pressure gradient of right upper and lower extremities was 3.2±13.5 mm Hg and significantly lower than preoperative value (P < 0.05). Postoperative pressure gradient of upper and lower extremities was significantly lower than preoperative value in both groups (P < 0.05). There was no statistical difference in preoperative and postoperative changes of pressure gradient of upper and lower extremities between the 2 groups (P > 0.05). Thirty-eighty patients (88.4%) were followed up from 3 months to 5 years. During follow-up, there was 1 patient whose blood flow velocity of the descending aorta was increasingly accelerated. Pressure gradient across the aortic arch was larger than 40 mm Hg. Computer tomography showed aortic arch restenosis. This patient received reoperation 8 months after the first discharge. Three patients whose aortic pressure gradient was larger than 20 mm Hg were still followed up. Aortic arch pressure gradient was less than 20 mm Hg in all the other patients. ConclusionBoth patch aortoplasty and extended sideto-end anastomosis are ideal surgical methods for the treatment of CoA and hypoplastic aortic arch. Appropriate surgical method should be chosen according to individual conditions of pediatric patients.