Objective By comparing with the traditional X-ray template measurement method, to explore the accuracy of artificial intelligence preoperative planning system (AI-HIP) to predict the type of prosthesis and guide the placement of prosthesis before total hip arthroplasty (THA) in adult patients with developmental dysplasia of the hip (DDH). Methods Patients with DDH scheduled for initial THA between August 2020 and August 2022 were enrolled as study object, of which 28 cases (28 hips) met the selection criteria were enrolled in the study. Among them, there were 10 males and 18 females, aged from 34 to 77 years, with an average of 59.3 years. There were 12 cases of the left DDH and 16 cases of the right DDH. According to DDH classification, there were 10 cases of Crowe type Ⅰ, 8 cases of type Ⅱ, 5 cases of type Ⅲ, and 5 cases of type Ⅳ. According to Association Research Circulation Osseous (ARCO) staging of osteonecrosis of the femoral head, 13 cases were in stage Ⅲ and 15 cases in stage Ⅳ. The disease duration was 2.5-23.0 years (mean, 8.6 years). The limb length discrepancy (LLD) was 11.0 (8.0, 17.5) mm. Before operation, the prosthesis types of all patients were predicted by AI-HIP system and X-ray template measurement method, respectively. And the preoperative results were compared with the actual prosthesis type during operation in order to estimate the accuracy of the AI-HIP system. Then, the differences in the acetabular abduction angle, acetabular anteversion angle, femoral neck osteotomy position, tip-shoulder distance, and LLD were compared between preoperative planned measurements by AI-HIP system and actual measurement results after operation, in order to investigate the ability of AI-HIP system to evaluate the placement position of prosthesis. Results The types of acetabular and femoral prostheses predicted based on AI-HIP system before operation were consistent with the actual prostheses in 23 cases (82.1%) and 24 cases (85.7%), respectively. The types of acetabular and femoral prostheses predicted based on X-ray template measurement before operation were consistent with the actual prostheses in 16 cases (57.1%) and 17 cases (60.7%), respectively. There were significant differences between AI-HIP system and X-ray template measurement (P<0.05). There was no significant difference in acetabular abduction angle, acetabular anteversion angle, femoral neck osteotomy position, and tip-shoulder distance between AI-HIP system and actual measurement after operation (P>0.05). LLD after operation was significantly lower than that before operation (P<0.05). There was no significant difference between the LLD predicted based on AI-HIP system and the actual measurement after operation (P>0.05). Conclusion Compared with the traditional X-ray template measurement method, the preoperative planning of AI-HIP system has better accuracy and repeatability in predicting the prosthesis type. It has a certain reference for the prosthesis placement of adult DDH.
Objective To summarize the biomechanical characteristics, diagnosis, and hip arthroscopic treatment of borderline developmental dysplasia of hip (BDDH) with Cam-type femoroacetabular impingement (Cam FAI). Methods The literature on BDDH with Cam FAI at home and abroad in recent years was extensively reviewed and analyzed. Results In patients with BDDH and Cam FAI, the femoral neck anteversion angle and femoral neck shaft angle increase, the pelvis tilts, and the acetabulum rotates, resulting in instability of the hip joint. In order to maintain the stability of the hip joint, the direction of biomechanical action of the hip joint has changed, which further affects the anatomical structures such as the proximal femur and acetabular morphology. BDDH with Cam FAI can be diagnosed clinically by combining lateral center edge angle, anterior center edge angle, and acetabular index. BDDH with Cam FAI can be effectively treated through arthroscopic polishing of the edges of the acetabular proliferative bone, excision of Cam malformations, and minimally invasive repair of the glenoid lip and cartilage of the hip joint. Conclusion Currently, there is no unified standard for the diagnosis and treatment of BDDH with Cam FAI. Minimally invasive treatment of the hip under arthroscopy can achieve good early- and medium-term effectiveness, and has certain advantages in repairing and maintaining the integrity of the glenoid lip and suturing/compression joint capsule. However, the long-term effectiveness needs to be further followed up to determine. The timing of surgery, intraoperative bone edge depth polishing, and joint capsule suturing/compression techniques also need to be further explored.
Severe psychomotor developmental delay resulting from early postnatal (within 3 months) seizures can be diagnosed as Early-Infantile Developmental and Epileptic encephalopathies (EIDEE). Its primary etiologies include structural, hereditary, metabolic and etc. The main pathogenesis may be related to the inhibition of normal physiological activity of the brain by abnormal electrical activity and the damage of the brain neural network. Ohtahara syndrome and Early Myoclonic Encephalopathy (EME) are typical types of EIDEE. The principle of treatment is to improve the cognitive and developmental function by controlling frequent seizures. When the seizure is difficult to control with drugs, surgical evaluation should be performed as soon as possible, and surgical treatment is the first choice for patients suitable for surgery. The types of surgery can be divided into excision surgery, dissociation surgery, neuromodulation surgery and etc. The current status of surgical treatment of EIDEE was described, and the curative effect of surgical treatment was explored, so as to help clinicians choose appropriate treatment methods.
ObjectiveTo explore the effect of false acetabulum on the development and anatomical morphology of proximal femur in Crowe type Ⅳ developmental dysplasia of the hip (DDH), providing a theoretical basis for the development of femoral reconstruction strategy and prosthesis selection for total hip arthroplasty. Methods The medical records of 47 patients (54 hips) with Crowe type Ⅳ DDH between February 2008 and March 2020 were retrospectively analyzed, of which 21 patients (26 hips) were Crowe type Ⅳa (type Ⅳa group) and 26 patients (28 hips) were Crowe type Ⅳb (type Ⅳb group). There was no significant difference in general data such as gender, age, height, weight, body mass index, and side between the two groups (P>0.05), which were comparable. The height of femoral head dislocation, the height of pelvis, and the proportion of dislocation were measured based on preoperative anteroposterior pelvic X-ray film. Based on the preoperative femoral CT scan data, the anatomical parameters of the femur and femoral medullary cavity were measured after three-dimensional reconstruction using Mimics19.0 software to calculate the canal fare index; and the femoral medullary cavity parameters were matched with the modular S-ROM prosthesis parameters. ResultsThe results of X-ray film measurement showed that the height of femoral head dislocation and the proportion of dislocation in type Ⅳa group were significantly higher than those in type Ⅳb group (P<0.05). There was no significant difference in the height of pelvis between the two groups (P>0.05). The results of CT three-dimensional reconstruction measurements showed that compared with the type Ⅳb group, the type Ⅳa group had less isthmus height, smaller femoral head, shorter femoral neck, narrower neck-shaft angle, increased anteversion angle, and higher greater trochanter, and the differences were significant (P<0.05). There was no significant difference in the height of femoral head, femoral offset, and height difference between greater trochanter and femoral head between the two groups (P>0.05). There was no significant difference in the mediolateral width (ML), anteroposterior width (AP), and diameter of the isthmus (Ci level) and the AP of the medullary cavity in the plane 40 mm distal to the most prominent point on the medial side of the lesser trochanter (C–40 level) (P>0.05), and the size of medullary cavity was significantly smaller in type Ⅳa group than in type Ⅳb group at the other levels (P<0.05). Compared with the type Ⅳb group, the difference between the outer diameter of the prosthetic sleeve and the diameter of the medullary cavity fitting circle in the plane where the center of femoral head rotation was located from the medial most prominent point of the lesser trochanter (C0 level) in type Ⅳa group was smaller, and the proportion of negative values was greater (P<0.05). The difference between the longest diameter of the prosthetic sleeve triangle and the ML of the medullary cavity in the plane 10 mm proximal to the most prominent point on the medial side of the lesser trochanter (C+10 level) in type Ⅳa group was smaller, and the proportion of negative values was greater (P<0.05). ConclusionFalse acetabulum has a significant impact on the morphology of the proximal femur and medullary cavity in patients with Crowe type Ⅳ DDH, and the application of three-dimensional reconstruction technique can accurately evaluate the femoral morphology and guide the selection of femoral prosthesis.
【Abstract】 Objective To evaluate the operative technique and the short-term cl inical effect of cementless total hiparthroplasty (THA) for developmental dislocation of the hip in adults. Methods From December 1997 to October 2006, 61patients (78 hips) with developmental dislocation of the hip were treated with the cementless THA. There were 8 males and 53 females with the average age of 31.4 years (ranging from 17 years to 56 years). According to the classification of Hartofilakidis, 15 cases were type I (18 hips), 23 type II (31 hips), and 23 type III (29 hips). All the patients were exposed through the posterolateral approach. The threaded cup with coating was put at or near the level of the true acetabulum in all cases. Full coating stems were used in femoral sides, and shortening osteotomy below trochanter of femur was performed in 12 cases. Results Sixty patients (76 hips) were followed up with the mean duration of 49 months (range 12 to 118 months). All the hips of osteotomy and bone ingrowth acquired union 3 to 14 months after the operation. No patient had radiographic evidence of aseptic loosening of prosthesis. The average leg length of the hips with femoral shortening osteotomy was lengthened 2.0 to 4.5 cm. All patients had pain rel ief and no obvious motion l imitation, l imp gait and pelvic obl iquity. The Harris scores were 40.28 ± 9.84 preoperatively and 90.92 ± 2.80 postoperatively (P lt; 0.001). One patient with postoperative femoral nerve palsy completely recovered 4 months after the operation. Conclusion Cementless THA for developmental dislocation of the hip in adults produces significantly better results, although it presents great technical difficulties.
ObjectiveTo investigate the effectiveness of sliding trochanteric osteotomy (STO) in total hip arthroplasty (THA) for Crowe type Ⅳ developmental dysplasia of the hip (DDH). Methods Between July 2016 and April 2021, 52 patients (57 hips) with Crowe type Ⅳ DDH who underwent primary THA were enrolled according to inclusion criteria. There were 5 males and 47 females with a median age of 51 years (range, 18-76 years). There were 47 cases of single hip and 5 cases of bilateral hips. The leg length discrepancy (LLD) was 50.50 (44.00, 55.00) mm, visual analogue scale (VAS) score was 8.0 (6.0, 9.0), and Harris score was 58.0±5.0 before operation. Trendelenburg sign was positive in 46 patients (46 hips). All patients underwent STO and THA using Wagner-cone stem. The operation time, intraoperative blood loss, blood transfusion volume, Trendelenburg sign, and related complications were observed. During follow-up, VAS and Harris scores were recorded to evaluate the hip pain and function. X-ray film was used to measure the LLD and observe the bone union situations. Results The operation time was 90-125 minutes (mean, 105 minutes). Introperative blood loss was 420-800 mL (mean, 640 mL). Ten patients underwent blood transfusion and the amount of allogeneic blood transfusion was 2-4 U (mean, 3 U). All incisions healed by first intention after operation. All patients were followed up 4-60 months (median, 24 months). At last follow-up, LLD was 6.00 (4.00, 7.75) mm, showing significant difference when compared with that before operation (Z=−6.278, P=0.000). After operation, 51 hips (89.5%) achieved bone union at the osteotomy site, 4 hips (7.0%) had fibrous union, and 2 hips (3.5%) had nonunion. The healing time of osteotomy was 3-12 months, with an average of 6 months. At last follow-up, the VAS score was 3.0 (2.0, 5.0) and the Harris score was 85.0±6.0. The differences between pre- and post-operation were significant (Z=−6.176, P=0.000; t=−25.285, P=0.000). Trendelenburg sign remained positive in 4 patients (4 hips) at last follow-up and the difference was significant when compared with preoperative (χ2=67.947, P=0.000). One patient had a medial femoral cortical fracture when Wagner-cone stem was implanted during operation, and 2 patients had early symptoms of sciatic nerve palsy after operation, and no other related complications occurred. Conclusion For Crowe type Ⅳ DDH patients, STO applied in THA can reduce the resected bone mass, provide better exposure of hip as well as improve function of hip abductor muscle. Wagner-cone stem is recommended.
Objective To evaluate the early effectiveness and summarize the initial application experiences of Mako robot-assisted total hip arthroplasty (THA) for developmental dysplasia of the hip (DDH) in adults. Methods Between August 2018 and January 2020, 55 cases of DDH (75 hips) were treated with Mako robot-assisted THA. There were 10 males and 45 females with an average age of 51 years (range, 30-73 years). There were 35 cases of unilateral hip and 20 cases of bilateral hips. The DDH was classified as Crowe type Ⅰin 29 hips, type Ⅱ in 20 hips, type Ⅲ in 6 hips, and type Ⅳ in 20 hips. The modified Harris score was 54.8±16.0, the hip joint range of motion was 90° (80°, 100°), and the leg length discrepancy (LLD) was 22.0 (10.5, 47.0) mm. The preoperative surgical plan was made in the robot system based on the CT data. The reaming and installation of the acetabular cup were completed with the assistance of the robot system. The distance between the rotation center of the hip joint and the teardrop (horizontal distance, vertical distance), inclination angle, and anteversion angle were measured on the pelvic X-ray film to evaluate the position of the acetabular prosthesis. The above indicators were compared with preoperative planning to evaluate the accuracy of robotic-assisted surgery. The modified Harris score, the range of motion, and the LLD were used to evaluate the early effectiveness. Results The 75 hips of THAs were completed with the assistance of Mako robots. There was no significant difference in the acetabular inclination angle, the horizontal distance and the vertical distance of the rotation center between the preoperative planning and the postoperative measurement values (P>0.05); the acetabular anteversion angle was significantly smaller than the postoperative measurement value (t=–2.482, P=0.015). Four hips located beyond the Lewinnek safety zone, and 71 hips located within the Lewinnek safety zone. All patients followed up 6-24 months (mean, 13 months). All incisions healed by first intention. At last follow-up, the modified Harris score was 85.5±11.2, the hip joint range of motion was 120° (110°, 120°), and the LLD was 3.8 (2.0, 8.1) mm; all improved significantly compared with preoperative ones (P<0.05). Except for one nerve injury case, there was no other complication. Conclusion Mako robot-assisted THA is a safe and effective method for adult DDH, which can optimize the acetabular cup positioning, hip function, and leg length, but the long-term effectiveness needs to be confirmed by further studies.
Objective To investigate the effectiveness of Y-shaped osteotomy for treatment of developmental coxa vara in children. Methods Between January 2008 and October 2011, 10 cases (14 hips) of developmental coxa vara were treated. There were 4 boys (5 hips) and 6 girls (9 hips), aged 5-12 years (mean, 7.8 years). All the children had obvious lameness and limitations of hip abduction, adduction, and rotation. The anteroposterior pelvic X-ray films showed that the collodiaphysial angle ranged from 46 to 110° (mean, 87°); Hilgenreiner-epiphyseal angle (HE) ranged from 36 to 93° (mean, 57°); and the articulotrochanteric distance (ATD) ranged from — 25 to 6 mm (mean, — 3 mm). The subtrochanteric Y-shaped osteotomy was performed and angle steel plate was used for internal fixation. Results All incisions healed by first intention without surgery-related complication. All cases were followed up 14-40 months (mean, 18 months). The symptom of lameness disappeared or obviously alleviated; the range of motion of hip abduction, adduction, and rotation were increased. Postoperative X-ray films showed that the vertical epiphyseal plate of proximal femur was returned to the horizontal. After operation, the collodiaphysial angle was 130-153° (mean, 137°); HE angle was 23-35° (mean, 27°); and the ATD was 3-22 mm (mean, 14 mm). According to LIU Jiande’s assessment standards, the results were excellent in 5 hips, good in 8 hips, and fair in 1 hip, and the excellent and good rate was 92.8%. The other children had no recurrence of coxa vara except 1 case after 30 months. Conclusion The Y-shaped osteotomy is a simple and effective method to treat developmental coxa vara in children, which can fully correct the deformity, and patients can exercise early because of firm internal fixation.