ObjectiveTo systematically review the efficacy of hamstring tendon autograft versus hamstring tendon allograft in anterior cruciate ligament reconstruction by arthroscopy. MethodsDatabases including PubMed, EMbase, The Cochrane Library (Issue 2, 2015), CNKI, VIP, WanFang Data were electronically searched to collect randomized controlled trials (RCTs) about hamstring tendon autograft versus hamstring tendon allograft in anterior cruciate ligament reconstruction by arthroscopy from inception to February 2015. Two reviewers independently screened literature, extracted data and assessed the risk of bias of included studies. Then, meta-analysis was performed using RevMan 5.2 software. ResultsA total of 6 RCTs involving 535 knees were included. The results of meta-analysis showed that:(1) Postoperative physical outcomes:There were no significant differences between the hamstring tendon autograft group and the hamstring tendon allograft group in positive rate of Lachman test (RR=1.25, 95%CI 0.92 to 1.71, P=0.15) and positive rate of Pivot shift test (RR=1.04, 95%CI 0.93 to 1.17, P=0.47) at 1 year postoperatively. (2) Postoperative functional recovery outcomes:There were no significant differences between both groups in KT-1000/2000 measurement (MD=-0.79, 95%CI -1.78 to 1.20, P=0.12), abnormal rate of IKDC scores (RR=1.03, 95%CI 0.90 to 1.1, P=0.42) and Lysholm scores (MD=0.23, 95%CI -1.86 to 2.33, P=0.83) at 1 year postoperatively. ConclusionHamstring tendon autograft and hamstring tendon allograft have similar efficacy in anterior cruciate ligament reconstruction by arthroscopy. Due to limited quality and quantity of the included studies, more large-scale and high quality studies are needed to verify the above conclusion.
ObjectiveTo compare the effectiveness of coracoclavicular ligament reconstruction between by using autologous plantaris tendon graft combined with hook plate fixation and allogeneic tendon graft combined with hook plate fixation for treating acromiocavicular joint dislocation. MethodsThirty-three patients with acromioclavicular joint dislocation who accorded with the inclusion criteria between January 2013 and June 2014 were assigned into 2 groups. The patients were treated with autologous plantaris tendon graft combined with hook plate fixation in group A (n=17), and with allogeneic tendon graft combined with hook plate fixation in group B (n=16). Thirteen-one patients was followed up more than 12 months (15 in group A and 16 in group B). There was no significant difference in gender, age, cause of injury, sides, time between injury and surgery, and type of dislocation (P>0.05). The assessments included operation time, hospitalization time, hospitalization expenses, shoulder range of motion, gap of acromioclavicular, Constant-Murley scores, and visual analogue scale (VAS) for pain. ResultsThe operation time of group A was significantly longer than that of group B, and the hospitalization expense was significantly lower than that of group B (P<0.05). There was no significant difference in hospitalization time (t=1.046, P=0.316). The incisions healed by first intention, and hook plate was removed after 3 months. The mean follow-up time was 21.3 months (range, 19-34 months) in group A and was 23.7 months (range, 18-37 months) in group B. X-ray examination showed no osteolysis. There was no significant difference in gap of acromiocavicular between 2 groups at preoperation, 1 week after operation, and last follow-up (P>0.05). No redislocation of acromioclavicular joint and rejection reaction occurred during follow-up. At last follow-up, there was no significant difference in shoulder range of motion, Constant-Murley score, and VAS score between 2 groups (P>0.05). ConclusionCoracoclavicular ligament reconstruction by autologous plantaris tendon or allogeneic tendon graft combined with hook plate fixation for the treatment of acromioclavicular joint dislocation can achieve good effectiveness. The appropriate treatment should be chosen according to the patient's economic situation.
Objective To compare the effectiveness between arthroscopic double-bundle and single-bundle anterior cruciate l igament (ACL) reconstruction with deep-frozen allografts. Methods Between January 2008 and January 2009, 105 patients undergoing arthroscopic ACL reconstruction with deep-frozen allografts were selected and randomly divided intosingle-bundle (n=59) or double-bundle (n=46) groups. Patients were evaluated preoperatively and postoperatively 6, 12, and 24 months. Of the patients, 93 (51 in the single-bundle group and 42 in the double-bundle group) were available for full evaluation. There was no significant difference in gender, age, height, weight, disease duration, compl ication, the International Knee Documentation Committee (IKDC) score, and Lysholm score between 2 groups (P gt; 0.05). The anterior drawer test and the Lachman test for all were rated as + in 2 groups, and the pivot shift test were rated as ++ before operation. Results All wounds healed by first intention, and no related compl ication such as fracture, infection, or deep venous thrombosis was observed. There was no significant difference in the IKDC score, Lysholm score, anterior drawer test, pivot shift test, and Lachman test between 2 groups at 6-month and 12-month follow-up (P gt; 0.05). The IKDC score, Lysholm score, pivot shift test, Lachman test, and the side-to-side difference measured by KT-1000 arthrometer in the double-bundle group were significantly better than those in single-bundle group at 24-month follow-up (P lt; 0.05). Conclusion The double-bundle ACL reconstruction with deep-frozen allografts has better effectiveness than the single-bundle ACL reconstruction.
ObjectiveTo investigate effectiveness of allogeneic tendon of " W” type knit in repair of traumatic anterior dislocation of sternoclavicular joint.MethodsBetween June 2013 and June 2017, 12 patients with traumatic anterior dislocation of sternoclavicular joint after poor conservative treatment were treated with allogeneic tendon of " W” type knit. Of them, 10 were males and 2 were females, aged from 25 to 58 years (mean, 42 years). All injuries were caused by traffic accidents. The time from injury to operation was 4-12 weeks (median, 6 weeks). All of them were closed injuries. The patients had no fracture around the shoulder, or blood vessels, nerves, and other adjacent limb joint injuries. The operation time, intraoperative blood loss, incision healing, and complications were recorded. The sternoclavicular joint was observed by X-ray film and CT at 1 year after operation. Visual analogue scale (VAS) score, University of California Los Angeles (UCLA) score, Rockwood score, modified Hospital for Special Surgery (HSS) score, and Constant-Murley score were used to evaluate the function of shoulder joint after operation.ResultsThe operation time was 60-80 minutes (mean, 70 minutes). The intraoperative blood loss was 50-100 mL (mean, 60 mL). Primary healing of incision was obtained in all patients without complications. All the patients were followed up 12-24 months (mean, 18 months). At 1 year after operation, X-ray film and CT examination showed that the position of sternoclavicular joint was satisfactory. At 1 year after operation, the Rockwood score was 12-14 (mean, 13). The UCLA score was 28-34 (mean, 31). The VAS score was significant lower than that before operation (P<0.05), and the Constant-Murley score and modified HSS score were significantly higher than those before operation (P<0.05).ConclusionThe repair of traumatic anterior dislocationr of sternoclavicula joint with allogeneic tendon of " W” type knit can effectively reconstruct the stability of the joint, retain the physiological fretting, and obtain satisfactory results.
Objective To explore the situation of tendon-bone heal ing when allogenic tendon graft is wrapped with autologous periosteum around the tendon in rabbits. Methods Twenty healthy New Zealand white rabbits with the age of 4-5 months were used in the experiment, weighing 2.5-3.0 kg. One-side posterior l imb was selected randomly as the test, and thecontralateral l imb was served as the control at the same time. The allogenic tendon graft was designed as a tendon-bone model in the proximal tibial metaphysis of rabbits. The portion of tendon in the bone tunnel was wrapped with autologous periosteal graft in which the cambium layer was facing the bone tunnel in the experimental group, while the portion of tendon in the bone tunnel was not wrapped with autologous periosteal graft in the control group. The histologic examination of the tendon-bone interface (n=2) and the biomechanical test for maximal pullout load (n=8) were conducted 4 and 8 weeks after operation, respec tively. Results All specimens were observed with naked eyes 4 and 8 weeks after the operation. Many new bones around bone tunnel outlet were seen in the experimental group, while a few or few new bones were seen in the control group. Four weeks after operation, histological observation showed there were a lot of prol iferative mesenchymal cells in the periosteal germinal layer in the experimental group and conspicuous membrane bone formation was obvious. The arrangement of massive osteoblasts around newborn bone trabecula was similar to pal isade. The newborn bone trabecula was l inked with the periosteum. Some loose connective tissues and few newborn bones between the tendon graft and the bone tunnel were seen in the control group, and the connection of them was loose. Eight weeks after operation, the connection between the tendon graft and the bone tunnel was tight and no gap existed in the experimental group. The number of newborn bones was large and their arrangement was relatively regular. The tidemark l ine was seen between the tendon graft and the bone tunnel, which was similar to normal tendon-bone interface. The prol iferation of fibroblast was active in the periosteum, and there were many fibrous joints betweenthe periosteum and the tendon graft. Partial bone formation was seen between the tendon graft and the bone tunnel in thecontrol group, with disorderly arrangement, and there were many collagen fibrous joints between the tendon graft and the bone tunnel. Four and 8 weeks after operation, the pullout or pull and break loads of the experimental group were (35.03 ± 1.21) N/ cm and (42.36 ± 1.31) N/cm, respectively, and those of the control group were (26.14 ± 6.13) N/cm and (31.63 ± 6.87) N/ cm, respectively. There was significant difference between the two groups (P lt; 0.05). Conclusion The transplantation of autologous periosteum graft wrapping around allogenic tendon graft may shorten the time of osteochondral ossification between the tendon graft and the bone tunnel, improve heal ing strength and promote tendon-bone heal ing in the bone tunnel in rabbits.
ObjectiveTo explore the effects of cryopreservation on the cell survival rate, cell viability, early apoptosis, migration ability, and tendon-related marker expression of tendon-derived stem cells (TDSCs) in rat patellar tendons.MethodsThe patellar tendon tissues were harvested from 12 4-month-old male Sprague Dawley rats; 12 patellar tendon tissues from 6 rats were cryopreserved (the experimental group), and the other 12 patellar tendon tissues were not treated (the control group). The patellar tendons were digested with 0.3% type I collagenase to obtain nucleated cells. The survival rate of nucleated cells was detected by trypan blue exclusion assay, and colony-forming ability by crystal violet staining. TDSCs were isolated and cultured to passage 3 (P3). The cell viability of TDSCs was detected by Alamar Blue method, the early apoptosis by Annexin V-FITC/PI assay, the cell migration ability by Transwell method, and the mRNA expressions of tendon-related markers [collagen type I (Col1α1), scleraxis (Scx), and tenomodulin (Tnmd)] by real-time quantitative PCR.ResultsThe survival rate of nucleated cells was 91.00%±3.63% in the control group, and was 61.65%±4.76% in the experimental group, showing significant difference (t=12.010, P=0.000). The formation of the primary nucleated cell clones was observed in 2 groups. At 12 days, the number of colonies forming of the experimental group [(8.41±0.33)/1 000 nucleated cells] was significantly lower than that of the control group [(15.19±0.47)/1 000 nucleated cells] (t=28.910, P=0.000). The percentage of TDSCs in the active nucleated cells in the experimental group (1.37%±0.09%) was significantly lower than that in the control group (1.67%±0.10%) (t=5.508, P=0.003). The growth trend of TDSCs (P3) in the 2 groups was consistent within 14 days. There was no significant difference in absorbance (A) value between 2 groups at each time point (P>0.05). The early apoptotic rate of TDSCs was 1.67%±0.06% in the experimental group and was 1.63%±0.06% in the control group, showing no significant difference (t=0.707, P=0.519). Under microscope, TDSCs adhered to the lower chamber of the Transwell chamber; the number of cells was 445.00±9.70 in the experimental group and was 451.50±12.66 in the control group, showing no significant difference (t=0.998, P=0.342). The relative mRNA expressions of Col1α1, Scx, and Tnmd were 3.498±0.065, 0.062±0.002, and (4.211±0.211)×10–5 in the experimental group and were 3.499±0.113, 0.062±0.001, and (4.341±0.274)×10–5 in the con-trol group, showing no significant difference (t=0.013, P=0.991; t=0.042, P=0.969; t=0.653, P=0.549).ConclusionThe survival rate of nucleated cells in cryopreserved rat tendon tissues is lower, but a large number of active TDSCs, and its cell viability, early apoptosis rate, migration ability in vitro, and cell tenogenic differentiation ability are remained.
ObjectiveTo study the effect of chemical extraction of allogeneic tendon and allogeneic chondrocytes for reconstruction of anterior labrum of shoulder joint in rabbits.MethodsThe body weight of 45 adult New Zealand white rabbits ranged from 2.5 to 3.0 kg. The Achilles tendons of 15 rabbits were taken and the allogeneic tendons were prepared by chemical extraction with antigen inactivation. The extracted tendons were compared with untreated tendons by HE and Masson stainings. Chondrocytes were isolated and cultured by trypsin method and identified by immunohistochemical staining of collagen type Ⅱ. The remaining 30 rabbits were used to prepare the model of anterior labrum defect of shoulder joint. After the allogeneic tendon was transplanted to the damaged labrum, the rabbits was randomly divided into two groups (15 in each group). In group A, the allogeneic chondrocytes were injected into the joint immediately after transplantation, while in group B, no treatment was made. At 4, 6, and 8 weeks after operation, 5 transplanted tendons of each group were taken. After general observation, HE staining was used to observe the number of nuclei, Masson staining was used to observe the expression of collagen fibers in muscle fiber tissues, and AB staining was used to detect the glycosaminoglycan level after transplantation, to evaluate the cell growth in the tissues of the two groups of allogeneic tendon.ResultsBy HE and Masson stainings, the allogeneic tendon antigen prepared by chemical extraction method was inactivated and the fibrous tissue structure was intact; collagen type Ⅱ immunohisto-chemistry staining showed that the cultured cells were chondrocytes. After tendon transplantation, the content of glycosaminoglycan in group A was significantly higher than that in group B (P<0.05). At 6 weeks after operation, HE staining showed that the nuclear in tendon tissue of group A was significantly more than that of group B (t=20.043, P=0.000). Masson staining showed that the number of nuclei in tendon tissue of group A was significantly increased, the muscle fibers and collagen fibers were interlaced, the tissue structure was more compact, and the tendon tissue was mainly blue stained; while the number of nuclei in group B was less, mainly collagen fibers of the original graft.ConclusionThe allogeneic tendon inactivated by chemical extraction can be used to reconstruct the defect of anterior labrum of shoulder joint in rabbits, and the combination of allogeneic chondrocytes can promote the healing of tendon transplantation.
Objective To compare the recovery of proprioception between autograft and allograft for anterior cruciate l igament (ACL) reconstruction. Methods Between January 2008 and January 2010, 40 patients underwent ACL reconstruction with autologous tendon (autograft group, n=20) and allogeneic tendon (allograft group, n=20). No significant difference was found in gender, age, disease duration, and function scores between 2 groups (P gt; 0.05). All the patients underwent the ACL reconstruction with single-bundle technique. The knee range of motion (ROM), International Knee Documentation Committee (IKDC) score, and Lysholm score were measured after operation. The proprioception was assessedby the joint position sense (JPS) at 3 and 12 months postoperatively. The normal knee was used as control. Results Thepatients of 2 groups achieved heal ing of incision by first intention without compl ication of infection or haemarthrosis. Allpatients were followed up 12-18 months (mean, 13.5 months). There were significant differences in knee ROM, IKDC score, and Lysholm score between preoperation and 12 months postoperatively in 2 groups (P lt; 0.05). There was no significant difference in JPS 30°, JPS 60°, and JPS 90° between affected knees and normal knees in autograft group at 3 months postoperatively (P gt; 0.05). No significant difference was found in JPS 30° between affected knees and normal knees in allograft group at 3 months postoperatively (P gt; 0.05); but significant differences were found in JPS 60° and JPS 90° between affected knees and normal knees in allograft group at 3 months postoperatively (P lt; 0.05). There was no significant difference in JPS 30°, JPS 60°, and JPS 90° between affected knees and normal knees in 2 groups at 12 months postoperatively (P gt; 0.05). Significant differences were also found in JPS 60° and JPS 90° between affected knees of 2 groups (P lt; 0.05) at 3 months postoperatively, whereas no significant difference was found in JPS 30° between affected knees of 2 groups (P gt; 0.05). No significant difference was found in JPS 30°, JPS 60°, and JPS 90° between affected knees of 2 groups at 12 months postoperatively (P gt; 0.05). Conclusion Autologous andACL reconstruction is better than allogeneic ACL reconstruction in the recovery of proprioception at early time after surgery.