Objective To investigate the cl inical appl icabil ity and value of internal fixator for the reconstruction of lumbar isthmus in the treatment of lumbar vertebral spondylolysis and to lay a fundation for its cl inical appl ication. Methods Sixteen healthy goats weighing 22.65-31.22 kg were selected to establ ish the models of vertebral spondylolysis at L5, which thereafter were randomized into two groups (n=8): bone graft group in which 0.8-1.1 g fresh autogenous bone was transplanted into the isthmus spondylolysis area, and internal fixation with bone graft group in which internal fixator was installed before transplanting 0.8-1.1 g fresh autogenous bone into the isthmus spondylolysis area. All animals were killed 8 weeks after operation to receive imaging, topographic anatomy and histology detection. Meanwhile, biomechanics test was performed by using 5 donated vertebral body specimens (4 males and 1 female aged 35-51 years old). The left isthmus of L5 vertebra was transected to serve as lumbar vertebral spondylolysis model. A mini-displacement sensor was put at the transected ends of the isthmus. Then loading was conducted with a constant velocity of 2 mm/min by electronic omnipotent tester simulating the direction of fixation force of the internal fixator, and the deformation value of the transected ends was collected by a dynamic data collector and analyzer. The loading wascontinued until the vertebra specimens were damaged. The deformation of displacement sensor and the closure of transected ends of the lumbar isthmus were observed. Results All the goats behaved normally shortly after operation, and no nerve injury induced by operation and no wound infection occurred. Bilaterally obl ique X-ray films of lumbar vertebra and topographic anatomy 8 weeks after operation showed the fusion rate of the internal fixation and bone graft group and the bone graft group was 100% and 62.5%, respectively, indicating there was a significant difference (P lt; 0.05). Histology observation showed 3 goats in the bone graft group presented empty bone trabecula, empty bone lacuna and the disappearance of osteocytes at the transected ends of lumbar isthmus; while in the internal fixation and bone graft group, the bone trabecula grew into cancellous structures with hematopoietic and fatty bone marrow tissue inside, and parts of the bone trabecula had various degrees of mosaic-l ike pattern. During the upload, the biomechanics test and data processing results showed when the external load was 40 N, the deformation of displacement sensor was identified and the gap between the transected ends of lumbar isthmus started to close; then with the increase of external load, the displacement sensor tended to ascend in a l inearity manner; while when the external load was 212 N, the displacement sensor had no further deformation, the gap between the transected ends of lumbar isthmus wascompletely closed, and the pressor effect appeared. Conclusion The internal fixator for the reconstruction of lumbar isthmus has mechanical effects of stabil izing and elevating pressure with a high fusion rate.
【Abstract】 Objective To determine the three-dimensional stabil ity of atlantoaxial reconstruction withanterior approach screw fixation through C2 vertebral body to C1 lateral mass and Gall ie’s technique (ASMG) for C1,2instabil ity. Methods Twenty-five human cadaveric specimens (C0-3 ) were divided randomly into 5 groups (n=5). Thethree-dimensional ranges of motion C1 relative to C2 were measured under the five different conditions:the intact state group (group A), type II odontoid fracture group (group B), posterior C1,2 transarticular screw fixation group (group C), ASM group (group D) and ASMG group (group E). The three-dimensional ranges of motions C1 relative to C2 by loading ± 1.5 Nm were measured under the six conditions of flexion/extension, left/right lateral bending, and left/right axial rotation. The obtained data was statistically analyzed. Results In each group, the three-dimensional ranges of motion C1 relative to C2 under the six conditions of flexion/extension, left/right lateral bending, and left/right axial rotation were as follows: in group A (8.10 ± 1.08), (8.49 ± 0.82), (4.79 ± 0.47), (4.93 ± 0.34), (28.20 ± 0.64), (29.30 ± 0.84)°; in group B (13.60 ± 1.25), (13.80 ± 0.77), (9.64 ± 0.53), (9.23 ± 0.41), (34.90 ± 0.93), (34.90 ± 1.30)°; in group C (1.62 ± 0.10), (1.90 ± 0.34), (1.25 ± 0.13), (1.37 ± 0.28), (0.97 ± 0.14), (1.01 ± 0.17)°; in group D (2.03 ± 0.26), (2.34 ± 0.49), (1.54 ± 0.22), (1.53 ± 0.30), (0.80 ± 0.35), (0.76 ± 0.30)°; in group E (0.35 ± 0.12), (0.56 ± 0.34), (0.44 ± 0.15), (0.55 ± 0.16), (0.43 ± 0.07), (0.29 ± 0.06)°. Under the six conditions, there were generally significant differences between group A and other four groups, and between group B and groups C, D and E (P lt; 0.001), and between group E and groups C, D in flexion/ extension and left/right lateral bending (P lt; 0.05). There was no significant difference between group E and groups C, D in left/right axial rotation (P gt; 0.05). Conclusion In vivo biomechanical studies show that ASMG operation has unique superiority in the reconstruction of the atlantoaxial stabil ity, especially in controll ing stabil ity of flexion/extension and left/right lateral bending, and thus it ensures successful fusion of the implanted bone. It is arel iable surgical choice for the treatment of the obsolete instabil ity or dislocation of C1, 2 joint.
ObjectiveTo evaluate the effectiveness of nitinol memory alloy two foot fixator combined with Kirschner wire in the treatment of trans-scaphoid perilunate dislocation.MethodsBetween September 2011 and October 2018, 17 patients with trans-scaphoid perilunate dislocation were treated with nitinol memory alloy two foot fixator and Kirschner wire. There were 12 males and 5 females, with an average age of 32.6 years (range, 23-52 years). The disease duration was 8 hours to 9 days, with an average of 6.5 days. The causes of injury included 6 cases of falling injury, 4 cases of traffic accident injury, 3 cases of stress injury of wrist caused by sports, 2 cases of violent injury of wrist caused by machine impact, 1 case of military training injury, and 1 case of other injury. One case was complicated with nerve injury. According to Herbert’s classification, all the fractures were type B4. At 1 week before operation, 3 months, 6 months after operation and last follow-up, the wrist function was evaluated according to the Krimmer scale score.ResultsAll the 17 patients were followed up 10.5-48 months, with an average of 18.6 months. There was no loosening or infection of the internal fixator, no necrosis of the scaphoid and lunate. The periosteal dislocations of the patients were well reduced and the scaphoid fractures all healed. The healing time was 4-18 months, with an average of 11.3 months. The Krimmer wrist scores were 37.5±4.4, 61.3±7.2, 83.3±9.3, 87.3±8.2 at 1 week before operation, 3 months, 6 months after operation and last follow-up, respectively. The Krimmer wrist score at each time point after operation was significantly improved when compared with that before operation (P<0.05), and at 6 months after operation and last follow-up than at 3 months after operation (P<0.05). There was no significant difference between at 6 months and last follow-up (P>0.05). At last follow-up, the Krimmer wrist function was excellent in 13 cases, good in 2 cases, fair in 1 case, poor in 1 case, and the excellent and good rate was 88.23%.ConclusionNitinol memory alloy two foot fixator combined with Kirschner wire in the treatment of trans-scaphoid periosteal dislocation has definite effectiveness, simple operation, and good recovery of wrist function after operation.
ObjectiveTo explore a new method of treating serious tibiofibula comminuted fracture by using three-dimensional (3-D) printing personalized external fixator. MethodsIn April 2015, a male patient (aged 18 years with a height of 171 cm and a weight of 67 kg) with left tibiofibula comminuted fracture was included in the study. Computer-assisted reduction technique combined with 3-D printing was used to develop a customised personalized external fixator for fracture reduction. The effectiveness was observed. ResultsThe operation time was about 10 minutes without fluoroscopy, and successful reduction was obtained. The patient had equal limb length after operation. X-ray films showed that the posterior angulation of distal fracture was corrected 37°, and the eversion angle was corrected 4°. The tibial fractures had good paraposition or alignment, and the lower limb force line was corrected completely. No new fracture displacement occurred. The clinical healing time of fracture was 3.5 months and the bone union was achieved after 8 months. The function of affected limb recovered well after operation. ConclusionA personalized external fixator for serious tibiofibula comminuted fracture reduction made by 3-D printing technique has the merits of easy manipulation, high individuation, accurate reduction, stable fixation, and no need of fluoroscopy.
A new fixator for spine was designed to restore the stability of spine in improving the treatment of thoraco-lumbar dislocation. This instrument was composed of six nails, two longitudinal connecting rods and two transverse connecting rods. On the surface of the nails, there were furrows engraved, instead of screw thread. It fixed the spine through pedicle of vertebra from the posterior approach. The fixed vertebrae were limited between two vertebrae. From 1989 th 1995, twelve patients with fracture-dislocation of thoraco-lumbar spine were reduced with this instrument. After four years follow-up, it showed that the deformity was corrected and the spine firmly fixed. Compared with Dick’s screws, it had the following advantages such as simple manipulation, increased strergth of nails and minimal damage to tissue during operation.