west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "塑形" 21 results
  • The influence of undercorrected orthokeratology on myopia control

    Objective To investigate the influence of undercorrected orthokeratology on myopia control, and the correlation between target and central corneal epithelial damage. Methods A retrospective study was conducted on 22 undercorrected orthokeratology lens wearers (37 eyes) from January 2016 to February 2017, and 25 full corrected wearers (47 eyes) during the concurrent period were randomly selected as the control group. The changes of axial length before and after orthokeratology lens wearing and the within-6-month central corneal epithelial damage after orthokeratology lens wearing were analyzed. Results The average annual increase of axial length was (0.13±0.15) mm in the undercorrected group, and (0.14±0.16) mm in the full corrected group, the difference was not statistically significant (P>0.05). Multiple linear regression analysis showed that there was no correlation between the axial growth and the undercorrection of the target (P>0.05), but a negative correlation between the axial growth and the age (P<0.01). After using orthokeratology, the average annual growth of the axial length in children aged 7-10 years was (0.25±0.16) mm, and (0.10±0.14) mm in children aged 11-15 years, the difference was statistically significant (P<0.01). The incidence of central corneal epithelial punctate staining in the (–4.25)-(–5.00) D target group was 27.08%, and that in the (–3.00)-(–4.00) D target group was 16.67%, the difference was not statistically significant (P>0.05). Conclusions The effect of orthokeratology on myopia growth is not affected by the undercorrected target, not related to the undercorrection of target, but negatively correlated with the age. Undercorrected orthokeratology can still be used for myopia control in high myopia patients. No correlation is found between the target and central corneal staining.

    Release date:2019-04-22 04:14 Export PDF Favorites Scan
  • PROGRESS OF MALLEABLE BONE PASTE/PUTTY

    Objective To review the progress and clinical application of malleable bone paste/putty. MethodsRecent literature about malleable bone paste/putty was reviewed and analyzed. ResultsThe preparation and clinical application of malleable bone paste/putty have become increasingly mature. Many kinds of malleable bone paste/putty have been applied extensively and the good clinical results have been achieved in the treatment of the irregular bone defects. The materials and methods for preparing malleable bone paste/putty are different. Then they have different bone repair abilities. ConclusionMalleable bone paste/putty provides effective method to treat irregular bone defects. But the malleable bone paste/putty still has some shortage, so further researches should be carried out.

    Release date:2016-08-31 04:22 Export PDF Favorites Scan
  • TREATMENT OF INTRA-ARTICULAR CALCANEAL FRACTURE BY BONE GRAFTING AND PLASTIC TI-ALLOY PLATE INTERNAL FIXATION

    To investigate the therapeutic effect of open reduction, bone grafting, and internal fixation with plastic ti-alloy plate on intra-articular calcaneal fracture. Methods From January 2005 to December 2007, 32 patients (37 feet) with intra-articular calcaneal fracture underwent open reduction, bone grafting of autogeneic il ium (30-80 g) and internal fixation of plastic ti-alloy plate. There were 21 males and 11 females aged 18-56 years old (average 42.1 years old). There were 5 cases of bilateral calcaneal fracture and 27 cases of unilateral calcaneal fracture, including 2 cases of open fracture and 30 cases of close fracture. According to Sanders classification system, there were 11 cases of type II, 18 cases of type III and 8 cases of type IV. Preoperatively, Bouml;hler angle was (— 9.6 ± 4.2)° and Gissane angle was (101.4 ± 10.6)°. Nine feet underwent emergency operation and 28 feet received operation 5-7 days after injury. Results The wounds of 34 feet healed by first intention. The wound margin of 3 feet was gray with a small amount of colorless exudates, and healed after dressing change. All patients were followed for 12-24 months (average 16 months). X-ray films displayed that the fracture all healed within 3-4 months after operation. At 6 months after operation, the Bouml;hler angle and the Gissane angle was (28.5 ± 6.1)° and (128.9 ± 4.8)°, respectively, indicating there were significant differences when compared with before operation (P lt; 0.05). According to Maryland foot score system, 15 cases were graded as excellent, 18 cases were good, 4 cases were poor, and the excellent and good rate was 89.19%. Conclusion Open reduction, bone grafting, and internal fixation with plastic ti-alloy plate is an effective method to treat intra-articular calcaneal fracture. Choosing right operational timing, performing subarticular surface grafting when necessary and using appropriate plastic ti-alloy plate internal fixation can minimize the incidence of postoperative compl ications

    Release date:2016-09-01 09:07 Export PDF Favorites Scan
  • A correlation study between the Mohawk expression level and the collagen fiber diameter of hamstring tendon graft after anterior cruciate ligament reconstruction

    ObjectiveTo evaluate the correlation between the Mohawk (MKX) expression level and the collagen fiber diameter of autologous hamstring tendon graft during the stable graft remodeling phase after anterior cruciate ligament (ACL) reconstruction.MethodsBetween January 2018 and August 2018, patients who underwent arth-roscopic single-bundle anatomical ACL reconstruction with autologous hamstring tendons for at least 48 months and also underwent second-look arthroscopy were enrolled in study. During the second-look arthroscopic procedures, ACL graft biopsies were performed from the surface of central part of the ligament. MKX expressions of ACL grafts were analysed by real-time fluorescent quantitative PCR (qRT-PCR). The ultrastructure of collagen fibers of grafts were evaluated by transmission electron microscopy, which included average diameter of collagen fibers (Dc), average diameter of large-diameter collagen fibers (DL), average diameter of small-diameter collagen fibers (DS), and large-small collagen fibers ratio (RL/S). The correlation between MKX expression level and graft collagen fiber diameter was calculated.ResultsTwenty-six patients met the selection criteria and their ACL graft specimens were enrolled in the study. The interval between ACL reconstruction and second-look arthroscopy was 52-128 months, with an average of 78.6 months. Arthroscopic graft remodeling score was 3-6 (mean, 4.8). There were 17 cases of excellent remodeling and 9 cases of fair remodeling. All ACL grafts showed typical bimodal distributions of both large-diameter collagen fibers and small-diameter collagen fibers, but the ultrastructural characteristics of the graft collagen fibers were different according to different remodeling status under arthroscopy. The DC, DL, DS, and RL/S of the graft specimens were (65.2±9.3) nm, (91.6±10.5) nm, (45.7±8.6) nm, and 0.73±0.12, respectively. The relative expression level of MKX was 1.42±0.11, which was positively linearly correlated with DC, DL, and RL/S, and the correlation coefficient was statistically significant (r=0.809, P=0.000; r=0.861, P=0.000; r=0.942, P=0.000), while there was no significant correlation between DS and relative expression level of MKX (r=0.147, P=0.238). Regression analysis showed that the relative expression level of MKX could predict the DC, DL, and RL/S results of the ACL graft specimens (P<0.05).ConclusionAfter autologous hamstring tendon grafts stepped into stabilized remodeling phase, MKX expression level could predict the diameter measurement results of collagen fibers and be used as an important evaluation basis for graft collagen anabolic metabolism.

    Release date:2019-08-23 01:54 Export PDF Favorites Scan
  • Application of triple stomach shaping technique in laparoscopic sleeve gastrectomy

    Objective To summarize and analyze the application value of triple stomach shaping technique in laparoscopic sleeve gastrectomy (LSG). Methods The clinical data of patients undergoing simple LSG with triple stomach shaping technique carried out by the General Surgery Obesity and Metabolic Diseases Center of Chengdu Third People’s Hospital from January to December 2021 were retrospectively collected, recording the operative time and the occurrence of recent complications such as postoperative nausea/vomiting, gastric leakage, bleeding, obstruction/torsion within 30 days after operation. Results A total of 966 patients were collected, including 294 males and 672 females. The age was 16–65 years, average age was (32.8±8.6) years. Body mass index was 27.5–47.2 kg/m2, average was (34.2±3.5) kg/m2. All operations were successfully completed without conversion to laparotomy. The operative time was 45–170 min, average was (100.2+33.4) minutes. Postoperative nausea/vomiting occurred in 484 cases (50.10%), bleeding in 2 cases (0.21%, intraperitoneal bleeding in 1 case, intragastric bleeding in 1 case), gastric leakage in 1 case (0.10%, grade B leakage), and no perioperative death occurred. Hospitalization time was 4–24 d, average was (7.55±2.47) d. Two patients (0.21%) were hospitalized again due to nausea and vomiting within 30 days after operation, they were relieved and discharged after conservative medical treatment. Conclusion Triple gastric shaping technology is more physiological, safe and suitable for promotion.

    Release date:2023-03-22 09:25 Export PDF Favorites Scan
  • Effect of free deep inferior epigastric artery perforator flap transplantation in breast shaping of two-staged breast reconstruction with vertical scar

    ObjectiveTo summarize the difficulties and key points of free deep inferior epigastric artery perforator flap (DIEP) transplantation in breast shaping of two-staged breast reconstruction with vertical scar.MethodsThe clinical data of 32 postoperative breast cancer patients after mastectomy who underwent free DIEP transplantation for breast reconstruction between October 2015 and October 2019, whose original surgical incisions were all vertical and longitudinal, were retrospectively analysed. All the patients were female, aged from 31 to 42 years, with an average of 34.6 years. The disease duration of breast cancer ranged from 9 to 48 months (mean, 22.8 months). Free DIEP pedicled with contralateral vessels were used in all cases, and the recipient vessels were intrathoracic vessels. Among them, 17 flaps were placed longitudinally, 15 flaps were placed obliquely; Z-shaped flaps were used in 18 cases to adjust the chest wall skin contracture, and contralateral breast reduction and mastopexy were accomplished at the same time in 23 cases.ResultsAll DIEP survived completely, and all donor and recipient sites healed by first intention. Internal thoracic lymph node metastasis was found in 1 case and treated with radiotherapy. All 32 cases were followed up 9-48 months, with an average of 19.4 months. The appearance and texture of all flaps were satisfactory, and only linear scar was left in donor site. Eleven patients underwent further autologous fat transplantation and nipple reconstruction. All patients had no effect on abdominal wall activity, and no local recurrence and metastasis was found.ConclusionIt is difficult to use free DIEP for two-staged breast reconstruction in patients received mastectomy with vertical longitudinal scar left. Combined with different breast shaping techniques, the outcomes can significantly improve.

    Release date:2021-10-28 04:29 Export PDF Favorites Scan
  • Research on Residual Aberrations Correction with Adaptive Optics Technique in Patients Undergoing Orthokeratology

    We conducted this study to explore the influence of the ocular residual aberrations changes on contrast sensitivity (CS) function in eyes undergoing orthokeratology using adaptive optics technique. Nineteen subjects' nineteen eyes were included in this study. The subjects were between 12 and 20 years (14.27±2.23 years) of age. An adaptive optics (AO) system was adopted to measure and compensate the residual aberrations through a 4-mm artificial pupil, and at the same time the contrast sensitivities were measured at five spatial frequencies (2,4,8,16, and 32 cycles per degree).The CS measurements with and without AO correction were completed. The sequence of the measurements with and without AO correction was randomly arranged without informing the observers. A two-interval forced-choice procedure was used for the CS measurements. The paired t-test was used to compare the contrast sensitivity with and without AO correction at each spatial frequency. The results revealed that the AO system decreased the mean total root mean square (RMS) from 0.356 μm to 0.160 μm(t=10.517, P<0.001), and the mean total higher-order RMS from 0.246 μm to 0.095 μm(t=10.113, P<0.001). The difference in log contrast sensitivity with and without AO correction was significant only at 8 cpd (t=-2.51, P=0.02). Thereby we concluded that correcting the ocular residual aberrations using adaptive optics technique could improve the contrast sensitivity function at intermediate spatial frequency in patients undergoing orthokeratology.

    Release date:2017-01-17 06:17 Export PDF Favorites Scan
  • 一种下肢残端塑形固定裤的设计与应用

    Release date: Export PDF Favorites Scan
  • 角膜塑形镜配戴后眼总和散光发生改变一例

    Release date:2021-06-23 07:35 Export PDF Favorites Scan
  • Comparison of the changes of corneal astigmatism after long-term spherical and toric orthokeratology wearing

    ObjectiveTo compare the changes of corneal astigmatism after long-term spherical and toric orthokeratology wearing, and to investigate the effects of different orthokeratology design on corneal astigmatism.MethodsThe medical records of myopic adolescent patients who have been prescribed spherical and toric orthokeratology in the contact lens clinic of West China Hospital, Sichuan University between January 2019 and December 2021 were analyzed retrospectively.The differences of corneal astigmatism changes after wearing spherical and toric orthokeratology for a long time and one month discontinuation were compared. The influencing factors of corneal astigmatism changes were analyzed. ResultsA total of 156 patients were included. There were 76 cases (76 eyes) in spherical orthokeratology group and 80 cases (80 eyes) in toric orthokeratology group. There was no significant difference between the two groups in age, gender, baseline myopia diopter and total lens wearing time (P>0.05). There were statistically significant differences between the spherical orthokeratology group and the toric orthokeratology group in the baseline corneal flat K value [42.1 (41.3, 43.3) vs. 43.1 (42.0, 44.1) D], baseline corneal steep K value [(43.4±1.3) vs. (44.6±1.5) D], baseline corneal astigmatism [(1.1±0.5) vs. (1.6±0.6) D], and baseline total eye astigmatism [−0.6 (−1.2, 0.0) vs. −1.4 (−1.8, −1.0) D] before wearing the orthokeratology (P<0.05). Compared with the baseline value, 1 month after the two groups stopped wearing the orthokeratology, the corneal flat K values became flatter [spherical orthokeratology group: 42.09 (41.28, 43.34) vs. 41.73 (40.98, 43.16) D, toric orthokeratology group: 43.09 (41.95, 44.10) vs. 42.61 (41.52, 43.56) D; P<0.05], the changes of corneal steep K values were not statistically significant (P>0.05), but the corneal astigmatism values increased [spherical orthokeratology group: (1.05±0.49) vs. (1.37±0.56) D, toric orthokeratology group: (1.62±0.57) vs. (1.99±0.63) D; P<0.05]. There was no significant difference in the changes of corneal flat K value, corneal steep K value and corneal astigmatism between the two groups (P>0.05). Multivariate analysis showed that age (P=0.011) and the total duration of orthokeratology wearing (P=0.004) were the main factors affecting the changes of corneal astigmatism. ConclusionAfter 1 month of non-wearing, the flat K value of the cornea becomes flat, the steep K value remains unchanged, and the corneal astigmatism increases. There is no difference in the effect of the spherical and toric orthokeratology on corneal astigmatism. The change of corneal astigmatism is related to the patient’s age and the total duration of wearing the orthokeratology. The younger the age, the longer the duration of orthokeratology wearing, the more significant the increase of corneal astigmatism after stopping wearing the orthokeratology.

    Release date:2022-12-23 09:29 Export PDF Favorites Scan
3 pages Previous 1 2 3 Next

Format

Content