west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "外固定支架" 26 results
  • 肘关节分裂脱位一例

    Release date:2018-02-07 03:21 Export PDF Favorites Scan
  • Treating Distal Radius Fracture Using External Fixator

    目的:评价外固定支架治疗桡骨远端骨折的疗效。方法:2004年3月至2008年8月以外固定支架或辅以克氏针、可吸收螺钉内固定治疗桡骨远端骨折37例。结果:31例获得4~28 个月(平均14 个月)的随访,所有骨折均临床愈合,平均愈合时间8周。腕关节功能按Sarmiento标准进行评定,优17例,良9例,可4例,差1例,优良率839%。结论:外固定支架治疗桡骨远端骨折疗效可靠,值得推广。

    Release date:2016-08-26 02:21 Export PDF Favorites Scan
  • Effectiveness comparison of suspension fixation plus hinged external fixator and double plate internal fixation in treatment of type C humeral intercondylar fractures

    Objective To compare the effectiveness of suspension fixation plus hinged external fixator with double plate internal fixation in the treatment of type C humeral intercondylar fractures. Methods Between January 2014 and April 2016, 30 patients with type C (Association for the Study of Internal Fixation, AO/ASIF) humeral intercondylar fractures were treated. Kirschner wire suspension fixation plus hinged external fixator was used in 14 cases (group A), and double plate internal fixation in 16 cases (group B). There was no significant difference in gender, age, injury cause, disease duration, injury side, and type of fracture between 2 groups (P>0.05). Results There was no significant difference in operation time and hospitalization stay between 2 groups (P>0.05). But the intraoperative blood loss in group A was significantly less than that in group B (P<0.05); the visual analogue scale (VAS) score at 1 day and 3 days after operation in group A were significantly less than those in group B (P<0.05). Primary healing of incision was obtained in all patients of 2 groups, and no surgery-related complications occurred. The patients were followed up 6-24 months (mean, 12.3 months) in group A and 6-24 months (mean, 12.8 months) in group B. The self-evaluation satisfaction rate was 85.7% (12/14) in group A and was 81.2% (13/16) in group B at 3 months after operation, showing no significant difference (χ2=0.055, P=0.990). Based on the improved Gassebaum elbow performance score at 6 months after operation, excellent and good rate of the elbow function was 78.6% (excellent in 5 cases, good in 6 cases, fair in 2 cases, and poor in 1 case) in group A and was 81.2% (excellent in 6 cases, good in 7 cases, fair in 2 cases, and poor in 1 case) in group B, showing no significant difference between 2 groups (χ2=0.056, P=0.990). Heterotopic ossification occurred at 3 months after operation in 1 case of each group respectively. The X-ray films showed bony union in all cases; no loosening or breakage of screw was observed. The bone union time showed no significant difference between 2 groups (t=–0.028, P=0.978). The time of internal fixation removal, the intraoperative blood loss, and VAS score at 1 day and 3 days after operation in group A were significant better than those in group B (P<0.05). Conclusion The suspension fixation plus hinged external fixator and double plate internal fixation for the treatment of type C humeral intercondylar fractures have ideal outcome in elbow function. But the suspension fixation plus hinged external fixator is better than double plate internal fixation in intraoperative blood loss, postoperative VAS score, and time of internal fixation removal.

    Release date:2017-07-13 11:11 Export PDF Favorites Scan
  • Multifunctional External Fixator for the Treatment of Femoral Intertrochanteric Fracture

    【摘要】 目的 探讨多功能外固定支架治疗老年股骨粗隆间骨折的疗效和优点。 方法 2007年7月-2009年10月,采用外固定架治疗28例老年股骨粗隆间骨折患者,其中男11例,女17例;年龄74~91岁,平均81岁。致伤原因:摔伤25例,交通事故伤3例。骨折按Evans分型:Ⅰ型1例,Ⅲ型15例,Ⅳ型12例。受伤至手术时间2~7 d。 结果 术后患者切口均Ⅰ期愈合,无延迟愈合及其他早期并发症发生。28例均获随访,随访时间5~14个月,平均9个月。X线片示骨折全部愈合,愈合时间11~24周,平均17周。无髋内翻和下肢短缩等并发症发生。术后3个月,采用Harris评分进行功能评价,优18例,良7例,差3例,优良率89.3%。出现轻度针道感染7例,中度5例,重度2例,针道感染率50%;合并糖尿病者2例出现中度针道感染,2例出现重度针道感染。重度者经局部换药、应用抗生素后愈合,后又反复出现,2~3个月取钉后愈合。无骨感染发生,患者均未出现褥疮,合并症无明显加重。 结论 外固定架治疗粗隆间骨折,手术创伤小,操作简便,符合生物力学原理,可以早期离床活动及早期骨折愈合。【Abstract】 Objective To explore the effectiveness and advantages of multifunctional external fixator for the treatment of femoral intertrochanteric fractures in the elderly patients.  Methods Twenty-eight patients with femoral intertrochanteric fractures including 11 males and 17 females receiving external fixator treatment between July 2007 and October 2009 were enrolled in this study. Their age ranged from 74 to 91 years old with the average to be 81 years. Twenty-five patients had the disease because of ground falls, and the other 3 were due to traffic accidents. Based on the Evans Type classification, there were 1 Type-Ⅰ case, 15 Type-Ⅲ cases, and 12 Type-Ⅳ cases. The time between injury and surgery was ranged from 2 to 7 days. Results All incisions of the patients healed during phase Ⅰ without delayed healing or other early complications. Follow-up was done to all the patients for 5 to 14 months, averaging 9 months. X-ray showed all fractures healed, and the healing time ranged from 11 to 24 weeks with an average of 17 weeks. No varus or leg shortening or other complications occurred. Three months after surgery, based on the Harris hip score for functional evaluation, there were 18 excellent cases, 7 good cases and 3 poor cases with a excellent and good rate of 89.3%. Mild pin tract infection was detected in 7 patients, moderate in 5, and severe in 2 with a total pin tract infection rate of 50%. Two patients with diabetes suffering from severe pin tract infection recovered by local medication and antibiotics, but the infection reoccurred repeatedly till the healing nails were taken. No bone infection of ulcers occurred, and the existing complications were not aggravated. Conclusion Treatment of intertrochanteric fractures with multifunctional external fixator is minimally invasive, simple, and consistent with biomechanical principles, which can promote early activities out of bed and early fracture healing for the patients.

    Release date:2016-09-08 09:26 Export PDF Favorites Scan
  • BIOMECHANICS STUDY ON THREE-DIMENSIONAL EXTERNAL FIXATOR FOR OSTEOPOROTIC FRACTURE

    ObjectiveTo explore the mechanical stability of the three-dimensional (3-D) external fixator for osteoporotic fracture so as to provide the biomechanical basis for clinical application. MethodsForty-five fresh frozen adult tibial specimens were selected to rapidly prepare the extracorporal tibia osteoporotic fracture models, and were randomly divided into 3 groups (n=15). Fractures were fixed with 3-D external fixators (3-D external fixators group), intramedullary nails (intramedullary nail group), and plate (plate group) respectively. Five specimens randomly from each group were used to do axial compression test, three-point bending test, and torsion test with microcomputer control electronic universal testing machine, then the mechanical parameters were calculated. ResultsIn the axial compression test, the displacement of 3-D external fixator group and intramedullary nail group were shorter than plate group, showing significant differences (P<0.05); but no significant difference was found between 3-D external fixator group and intramedullary nail group (P>0.05). In the three-point bending test and torsion test, the deflection and the torsional angle of 3-D external fixator group and intramedullary nail group were smaller than plate group, showing significant differences (P<0.05); but no significant difference was found between 3-D external fixator group and intramedullary nail group (P>0.05). ConclusionThe 3-D external fixator can fix fracture three-dimensionally from multiple plane and it can offer strong fixing. It is biomechanically demonstrated to be suitable for osteoporotic fracture.

    Release date:2016-08-25 10:18 Export PDF Favorites Scan
  • UNILATERAL EXTERNAL FIXATOR IN THE TREATMENT OF INTERTROCHANTERIC FRACTURES OF FEMUR

    Forty cases of intertrochanteric fractures of femur were treated with percutaneous nonmetallic external fixator. The patients were followed up for 6 months to 3 years, and the fractures were all united without coxa vara or shirtening deformities. There was no mortality in this series. This method had the advantages ofbeing simple, save time and effort, less traumatic and early ambulation. The design of the apparatus tallied with the biomechanics of the neck and shaft of the femur.

    Release date:2016-09-01 11:12 Export PDF Favorites Scan
  • Effectiveness analysis of mini external fixator combined with bone cement spacer in treatment of gouty hallux rigidus with bone defect

    Objective To explore the effectiveness of mini external fixators combined with bone cement spacers in the treatment of gouty hallux rigidus with bone defects. Methods A retrospective analysis was conducted on the clinical data of 21 male patients diagnosed with gouty hallux rigidus and bone defects, treated with mini external fixators combined with bone cement spacers between January 2017 and December 2024. The age ranged from 35 to 72 years, with an average age of 61.1 years. The disease duration was 12-35 years, with an average of 18.2 years. The American College of Rheumatology (ACR) gout score ranged from 16 to 23, with an average of 18.6. All 21 cases of hallux rigidus were classified as grade 3 according to the Coughlin classification. Clinical efficacy was evaluated preoperatively and at 6 months postoperatively using the visual analogue scale (VAS) score for pain, the dorsiflexion angle of first metatarsophalangeal joint in a weight-bearing state, and the American Orthopaedic Foot & Ankle Society (AOFAS) score. Radiological evaluation was performed by measuring the hallux valgus angle (HVA) using weight-bearing X-ray films and the tophi volume using dual-energy CT. Results The operation time ranged from 30 to 56 minutes, with an average of 42.05 minutes. The intraoperative blood loss varied between 10 and 30 mL, averaging 20 mL. All 21 patients were followed up 6-15 months, averaging 9.3 months. One patient experienced delayed wound healing due to the liquefaction of residual tophus; no other patients exhibited complications such as wound or pin tract infections, skin necrosis, fractures, or metastatic metatarsalgia. Six patients experienced acute gout attacks 4-7 days postoperatively, which were effectively alleviated through symptomatic treatment. At 6 months after operation, patients showed significant improvements in HVA, tophus volume, VAS scores, AOFAS scores, and the dorsiflexion angle of first metatarsophalangeal joint compared to preoperative values, with significant differences (P<0.05). ConclusionMini external fixator combined with a cement spacer is an effective treatment for gouty hallux rigidus with bone defects.

    Release date:2025-09-28 06:13 Export PDF Favorites Scan
  • BIOMECHANICAL EVALUATION OF STABILITY OF THE VOLAR CAPSULAR LIGAMENT COMPLEX

    【Abstract】 Objective To investigate the effect of the volar capsular l igament complex on stabil ity of the wrist jointand to provide basic biomechanical theoretical criteria for cl inic appl ication of the external fixator. Methods Nine upperl imbs specimens (left 6, right 3) were taken from fresh adult cadavers to make wrist joint-bone capsular l igament complex specimens. Firstly, soft tissues of forearms and hands were resected and capsular membranes and l igaments were reserved to make the bone-articular l igament complex (normal specimen). Secondly, the volar capsular l igament complex was cut off from radial malleolus to ulnar malleolus (impaired specimen). Thirdly, the impaired volar capsular l igament complex was interruptedly sutured by the use of 4# suture silk (repaired specimen). To simulate cl inical operation with external fixator, the biomechanical test was done according to the sequence (normal, impaired, repaired, repaired and fixed, impaired and fixed). Statistical significance was analyzed through selected loads at the three different shifts (1.5, 2.0, 2.5 cm). Results According to the sequence (normal, impaired, repaired, repaired and fixed, impaired and fixed), when the shift was 1.5 cm, the different respective loads were (60.74 ± 20.60), (35.23 ± 13.88), (44.36 ± 20.78), (168.40 ± 29.21) and (139.00 ± 33.18) N, respectively. When the shift was 2.0 cm, the different loads were (138.46 ± 12.93), (87.17 ± 24.22), (97.52 ± 23.29), (289.00 ± 54.29) and (257.98 ± 55.74) N, respectively. When the shift was 2.5 cm, the different loads were (312.87 ± 37.15), (198.16 ± 37.14), (225.66 ± 30.96), (543.15 ± 74.33) and (450.35 ± 29.38) N, respectively. There was no statistically significant difference between the impaired and repaired specimens (P gt; 0.05). Similarly, there was statistically significant difference among the rest specimens (P lt; 0.05). The same statistical results were obtained when the two different shifts were compared. There was statistically significant difference at the three different shifts for the same specimen (P lt; 0.05). Conclusion Volar capsular l igament complex is an important anatomic structure to keep stabil ity of the wrist joint. The carpal instabil ity arises out of the injured complex. Repairing the injured complex only can not immediately restore stabil ity of the wrist joint. The external fixator can effectively help to diminish the relative shift of the impaired capsular l igament complex, to reduce the load of the repaired complex and to protect the complex accordingly. The device plays an important role in maintaining stabil ity of the wrist joint.

    Release date:2016-09-01 09:12 Export PDF Favorites Scan
  • 微型外固定支架在虎口外伤急诊治疗中的应用及疗效

    目的探讨微型外固定支架在急诊治疗虎口外伤中的应用及临床疗效。 方法2009年2月-2011年6月,收治虎口外伤患者34例。男21例,女13例;年龄18~65岁,平均31.4岁。致伤原因:机器冲压伤15例,重物压砸伤12例,切割伤5例,爆炸伤2例。受伤至入院时间20 min~6 h 30 min。按创伤程度及范围,26例为简单损伤,8例为复合性损伤。急诊清创后一期微型外固定支架开大虎口或联合虎口“Z”字成形治疗,复合性损伤者二期行皮瓣修复。 结果术后1例发生针道感染,经对症处理后愈合;其余患者切口均Ⅰ期愈合,复合性损伤患者皮瓣及供区植皮均顺利成活。31例获随访,随访时间5~14个月,平均7.5个月。末次随访时虎口开大角度为65~95°,平均80°。拇指指间关节纹尺侧点与示指掌指关节桡侧点距离为4.0~5.5 cm,平均4.8 cm;按顾玉东等的评价方法评价,获优19例,良10例,差2例,优良率达93.5%。 结论在虎口外伤急诊治疗中,采用微型外固定支架开大虎口,手术操作简便,损伤小,避免了虎口挛缩的发生。

    Release date:2016-08-31 04:22 Export PDF Favorites Scan
  • 外固定架结合有限内固定治疗新鲜胫腓骨开放性粉碎性骨折

    Release date:2016-09-01 09:28 Export PDF Favorites Scan
3 pages Previous 1 2 3 Next

Format

Content