west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "多层螺旋CT" 49 results
  • 多层螺旋CT对肠扭转的诊断意义

    目的 探讨多层螺旋CT对肠扭转的诊断价值。 方法 回顾性分析2007年8月-2009年11月经临床和手术证实为肠扭转15例的CT 平扫、增强及多平面重建影像表现。 结果 15例中,CT表现为肠系膜血管漩涡征9例,鸟嘴征1例,C型肠袢征呈5例,肠壁水肿征8例,腹水征3例,肠腔扩张、积气积液征14例。 结论 多层螺旋CT扫描及多平面重建检查,对肠扭转的诊断具有重要价值。

    Release date:2016-09-08 09:47 Export PDF Favorites Scan
  • Retrospective Analysis of Multi-detector Spiral CT in Adrenal Ganglioneuroma(8 Cases)

    目的:探讨肾上腺节细胞神经瘤的CT表现特征,以提高此病CT诊断的准确性。方法:回顾性分析8例经病理确诊为节细胞神经瘤的CT表现,并与病理结果对照研究。结果:8例肿瘤边界均清晰,无周围组织和血管侵犯征象。CT平扫呈均匀稍低密度,CT值约18~35 HU,其中内有点状钙化者3例(37.5%)。CT增强扫描有轻度强化,CT值约30~45 HU。CT征象符合病理表现。结论:肾上腺节细胞神经瘤有一定的CT表现特点,多层螺旋CT扫描有助于提高肾上腺节细胞神经瘤诊断的准确性。

    Release date:2016-08-26 03:57 Export PDF Favorites Scan
  • Diagnostic Value of MSCT and MRI for Stasis Cirrhosis

    Objective To investigate multi-slice spiral CT (MSCT) and MRI features of stasis cirrhosis and the diagnostic value of MSCT and MRI. Methods MSCT and MRI findings of 35 patients with stasis cirrhosis were studied. The size of liver and spleen, the diameter of hepatic vein (HV), enhancement pattern of liver parenchyma, contrast medium reflux in inferior vena cava (IVC) and (or) HV, ascites, number of varices and correlated abnormalities were reviewed. Results The volume index of liver and spleen of 35 patients was 4434.95 cm3 and 621.92 cm3 respectively. The mean diameter of HV of 27 patients (77.1%) was 3.61 cm and HV of other 8 patients (22.9%) were too small to show. Number of patients showed waves of borderline, inhomogeneous pattern of parenchymal contrast enhancement, contrast medium reflux in IVC and (or) HV, varices and ascites was 5 (14.3%), 29 (82.9%), 20 (57.1%), 16 (45.7%), and 6 (17.1%), respectively. Correlated abnormalities included cardiac enlargement 〔4 cases (11.4%)〕, pericardium thickening 〔11 cases (31.4%)〕, and pericardial effusion 〔2 cases (5.7%)〕. Conclusions Stasis cirrhosis mainly demonstrate liver enlargement, inhomogeneous pattern of parenchymal contrast enhancement, contrast medium reflux in IVC and (or) HV, and slight portal hypertension. MSCT and MRI play invaluable roles in diagnosis, differential diagnosis and etiological diagnosis of stasis cirrhosis.

    Release date:2016-09-08 11:04 Export PDF Favorites Scan
  • Applications of New Imaging Techniques in Digestive System

    Release date:2016-09-08 11:49 Export PDF Favorites Scan
  • Multidetector CT and Magnetic Resonance Imaging Features of Solitary Fibrous Tumors in the Pelvis and the Relevant Pathologic Basis Changes

    In order to investigate the features of multidetector CT (MDCT) and magnetic resonance imaging (MRI) as well as the corresponding pathogic basis of solitary fibrous tumor (SFT) in the pelvis, we collected the clinical data of 13 patients with pathologically confirmed SFT in pelvis, and retrospectively reviewed the MDCT and MRI appearances. Of these enrolled patients, 6 received MDCT scans, 5 underwent MRI scans, and 2 underwent both MDCT and MRI examinations. Shown on the MDCT and MRI, the maximum diameters of the masses ranged from 4.0 to 25.2 cm (averaged 11.8 cm). Six masses were lobulated, and seven were round or oval. In addition, all masses were well-defined and displaced the adjacent structures to some degrees. On the computed tomography, all masses were of isodensity on unenhanced scans in general, among which five masses were demonstrated with hypodense areas. On the MRI T1-weighted image, all lesions were isointense, of which patchy hypointense areas were detected in 3 cases and radial hypointense areas were in 3 cases, and the other one was presented with homogenous intensity. On T2-weighted images, most of the lesions were mixed hyperintense, of which 3 cases were of heterogenous hyperintesity, radial hypointense areas were detected in 3 patients, and the other one was homogenously intense. On enhanced computed tomography and MRI, large supplying vessels were found in 4 cases; 12 cases showed moderate to conspicuous enhancement, and the other one was presented with mild homogenous enhancement. Of the patients with moderate to conspicuous enhancement, patchy areas of non-enhancement were detected in 7 cases, radial areas of progressive enhancement were detected in 3 cases, and the remained 2 cases showed homogenous enhancement. On pathology, the radial area presented as progressive enhancement was fibrosis. During the follow-ups after surgery, 2 patients had local recurrence and 1 had metastasis to liver. In conclusion, the SFT in the pelvis are commonly presented as a large solid, well-defined and hypervascular mass with necrosis or cystic changes at some extents together with the displacement of adjacent structures. The radial area with hypointensity on T2-weighted image and with progressive enhancement on enhanced magnetic resonance imaging is an important feature of SFT, which can be helpful for the diagnosis of this mass.

    Release date:2021-06-24 10:16 Export PDF Favorites Scan
  • ACCURACY OF RELATED PARAMETERS TO SCREW PLACEMENT IN LOWER CERVICAL PEDICLE MEASURED BY SPINAL VIRTUAL SURGERY SYSTEM

    Objective To evaluate the accuracy of the related parameters measured by spinal virtual surgery system (SVSS) three-dimensional (3D) techniques by comparing with the parameters measured by multi-spiral CT (MSCT) workstation. Methods Seven vertebrae specimens of adult men were scanned with MSCT, and the messages were sent toMSCT workstation and SVSS. The 3D image of spine was reconstructed by using volume rendering and multi-planar reformation; based on the parameter requirement of lower cervical pedicle fixation, 10 related parameters were measured. Then SPSS11.0 analyzer software was used to analyze the parameters measured by 2 systems. Between June 2009 and March 2010, 6 patients who received screw insertion in lower cervical spines were given MSCT scanning, then the messages were sent to SVSS 3D reconstruction to evaluate the situation and to collect the parameters of pedicle screw insertion. Results SVSS measurement showed that 1 pedicle was clausura (C3) and the diameters of 4 pedicles in coronal view were lee than 3 mm (C4 in 1, C5 in 2, C6 in 1), which did not fit for screw insertion; the results were similar to those by MSCT measurement. A total of 66 lower cervical pedicle were measured successfully. Significant differences were found in 14 parameters as follows between 2 systems (P lt; 0.05): the left pedicle height of C3, the both sides pedicle width of C4, the right pedicle spongy width of C4, the left X-direction entrance of C6, the both sides Y-direction entrance of C3, total pedicle length of sagittal view in both sides pedicle of C3 and the left pedicle of C5, total pedicle length of axial view in C3 pedicles, the left pedicle of C5, and the right pedicle of C6. There was no significantdifference in the other parameters (P gt; 0.05). In 6 cl inical cases, 34 screws were inserted, the postoperative MSCT scanning showed that 30 screws were placed successfully. The rate of accuracy was 88.24%. According to the Richter’s perforation classification, perforation at grade I and at grade II occurred in 2 cases (5.88%), respectively. Conclusion The accuracy of the parameters measured by SVSS is similar to that by MSCT.

    Release date:2016-08-31 05:42 Export PDF Favorites Scan
  • Low Dose MSCT Diagnosis of Pulmonary Fungal Infection

    Objective To explore the diagnosis value of the low dose multi-slice spiral computed tomography (MSCT) imaging in pulmonary fungal infection in order to improve its diagnosis level. Methods CT manifestations of 106 cases of pulmonary fungal infection confirmed by operation, pathology, mycetes cultivation and follow-ups of clinical therapy were retrospectively analyzed. All cases underwent low dose MSCT examinations including CARE dose 4D and sinogram affirmed iterative reconstruction technology, and 6 cases underwent contrast-enhanced CT scanning. Results Among the basic MSCT findings of pulmonary fungal infection, they showed patch-nodular type in 54 cases, solid variant in 38 cases, and tumor type in 14 cases. In all cases, 91 cases displayed as mulifocality, 83 cases as polymorphism and 78 cases as polytropy. Among the 106 cases with comparative distinctive MSCT manifestations, bud of branch sign were showed in 39 cases, halo sign in 32 cases, wedge shape consolidation in 19 cases, ice needle sign in 15 cases, crescentic sign in 11 cases, air ring sign in 6 cases, and contra-halo sign in 4 cases. The nodules in the cavities were not enhanced in enhanced scan in 5 cases. Conclusions There are some distinctive MSCT findings in patients with pulmonary fungal infection. Pulmonary fungal infection can be diagnosed with typical MSCT findings in close combination with the clinical information.

    Release date:2016-10-02 04:56 Export PDF Favorites Scan
  • 下颌埋伏牙拔除术前多层螺旋CT后处理技术的定位价值

    目的:探讨多层螺旋CT后处理技术对下颌埋伏牙定位诊断的应用价值。方法:有临床症状的下颌埋伏牙患者189例,进行多层螺旋CT扫描,应用图像后处理技术进行多层面重建,可在任意角度观察埋伏牙图像。结果:不易定位牙的位置、牙轴方向、牙体形态被清晰准确地显示出来。结论:多层螺旋CT后处理技术对埋伏牙定位精确,能清晰显示其形态、萌出方向及与邻牙间的关系。

    Release date:2016-08-26 02:21 Export PDF Favorites Scan
  • Evaluation of Multi-Slice Spiral CT for The Papillary Thyroid Carcinoma

    Objective To explore the manifestations and features of multi-slice spiral CT (MSCT) in the diagnosisof papillary thyroid carcinoma (PTC). Methods Preoperative MSCT data of 35 cases of PTC proved by operation and pathology in our hospital form May. to Jun. in 2013 were observed retrospectively, to analyze the manifestations and characteristics of MSCT for it. Results Of 35 patients with PTC, MSCT totally showed 48 lesions, 68.6% (24/35) of patients with single lesion, 31.4% (11/35) of patients with 2-3 lesions, and 62.9% (22/35) of patients with lymph node metastasis. Of the 48 lesions, 29.2% (14/48) of lesions located in the left lobe, 70.8% (34/48) of lesions located in the right lobe;the lesions’ maximum diameter were 0.4-5.8cm, with the average maximum diameter of 1.3cm. There were 39.6% (19/48) of lesions with uneven density, 25.0% (12/48) of lesions with irregular shape, 47.9% (23/48) of lesions with blurred edges, 18.8% (9/48) of lesions had papillary enhanced tumor nodules, 10.4% (5/48) of lesions had peritumoral incomplete enhanced ring sign, 22.9% (11/48) of lesions invaded surrounding tissue or organs. There were 35.4% (17/48) of lesions had calcification, in which 76.4% (13/17) of lesions were fine granular calcification, 11.8% (2/17) of lesions were mixed calcification, and 11.8% (2/17) of lesions were coarse calcification. Conclusion MSCT manifestations of PTC have certain characteristics, which can provide imaging basis for clinical treatment options.

    Release date:2016-09-08 10:35 Export PDF Favorites Scan
  • FABRICATION AND APPLICATION IN VITRO OF PEDICLE GUIDE DEVICE FOR PEDICLE SCREWS INSERTION

    Objective To evaluate the accuracy of pedicle guide device for the placement of the pedicle screws. Methods Pedicle guide device was designed and made for the anatomical trait of pedicle. The 3-Danatomical data of the thoracic pedicles were measured by multislice spiral CT in two embalmed human cadaveric thoracic pedicles spine(T1 -T10). Depending on transverse section angle(TSA) and sagittal section angle(SSA) of pedicle axis, the degree of horizontal dial and sagittal dial were adjusted in the guide device. The screws wereinserted bilaterally in the thoracic pedicles by using the device. After pulling the screws out, the pathways were filled with contrast media. The TSA and SSA of developed pathways were measured. Results Analysis of the difference between pedicle axis and developed pathway was of no statistical significance(P>0.05). Conclusion The guide device could be easilyoperated and guarantee high accuracy of the pathways of screws and the incidence of pedicle penetration could be significantly reduced.

    Release date:2016-09-01 09:29 Export PDF Favorites Scan
5 pages Previous 1 2 3 4 5 Next

Format

Content