west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "接骨板" 39 results
  • Treatment of posterolateral tibial plateau fractures with a novel lateral tibial plateau annular plate via fibular neck osteotomy approach

    Objective To investigate the effectiveness of a novel lateral tibial plateau annular plate (hereinafter referred to as the novel plate) fixation via fibular neck osteotomy approach for posterolateral tibial plateau fractures. Methods Between January 2015 and December 2018, 22 patients with posterolateral tibial plateau fractures were treated. There were 10 males and 12 females with an average age of 39.0 years (range, 25-56 years). Seven fractures were caused by falls, 10 by traffic accidents, and 5 by falling from height. The time from injury to hospitalization ranged from 3 to 12 days, with an average of 7.0 days. All patients were closed fractures. According to Schatzker classification, the fractures were classified as type Ⅱ in 8 cases, type Ⅲ in 9 cases, type Ⅴ in 1 case, and type Ⅵ in 4 cases. The fractures were fixed with the novel plates after reduction via fibular neck osteotomy approach. The fracture reduction and healing were observed by X-ray film after operation. The range of motion of the knee joint was recorded and the function was evaluated by modified American Hospital for Special Surgery (HSS) score. Results All operations were completed successfully. The operation time was 60-95 minutes (mean, 77.6 minutes). The intraoperative blood loss was 100-520 mL (mean, 214.5 mL). There was 1 case of common peroneal nerve injury during operation and 2 cases of fat liquefaction of incision after operation. All patients were followed up 13-32 months (mean, 19.4 months). Postoperative X-ray films showed that the fracture reduction was good in 17 cases and moderate in 5 cases, and all fractures healed with a healing time of 10-18 weeks (mean, 13.0 weeks). At last follow-up, the range of motion of the knee joint ranged from 100° to 145° in flexion (mean, 125.5°) and from 0° to 4° in extension (mean, 1.2°). The modified HSS score was 82-95 (mean, 86.3). There was no complications such as plate deformation, screw fracture, fracture reduction loss, skin necrosis, and so on. Conclusion For posterolateral tibial plateau fractures, the novel plate fixation via fibular neck osteotomy approach has the advantages of clear intraoperative field, firm fracture fixation, and less postoperative complications, which is beneficial to the recovery of knee joint function.

    Release date:2022-09-30 09:59 Export PDF Favorites Scan
  • Surgical techniques and effectiveness of volar locking plates for senile delayed distal radius fractures

    Objective To investigate the surgical technique and effectiveness of volar locking plates for senile delayed distal radius fractures. Methods Between October 2014 and September 2015, 25 cases of delayed distal radius fractures were treated by volar locking plates. There were 3 males and 22 females with an average age of 73 years (range, 65-87 years). Injury was caused by tumble in 19 cases and by traffic accident in 6 cases. All the cases had closed fracture. According to the AO classification, 10 cases were rated as type A2, 7 cases as type A3, 3 cases as type B3, and 5 cases as type C1. The manual reduction and plaster immobilization were performed in 18 cases first, but reduction failed; no treatment was given in 7 cases before surgery. The time from injury to surgery was from 33 to 126 days (mean, 61 days). Preoperatively, the volar tilting angle was (–16.0±3.1)°; the ulnar inclining angle was (10.8±7.0)°; the radial shortening was (11.2±3.6) mm; the wrist range of motion was (41.0±7.5)° in flexion and was (42.0±6.3)° in extension; and the grip strength was 33.0%±3.1% of normal side. Results All incisions healed primarily, and no postoperative complication occurred. The patients were followed up 1-1.5 years (mean, 1.3 years). The X-ray films showed that fracture union was achieved in all the patients, with the mean healing time of 9.2 weeks (range, 8-12 weeks); the displacement of the articular surface was less than 1 mm. At last follow-up, the volar tilting angle was (13.1±3.2)°; the ulnar inclining angle was (21.9±4.6)°; the radial shortening was (2.0±1.1) mm; the wrist range of motion was (52.0±11.7)° in flexion and was (65.0±4.8)° in extension; and the grip strength was 84.0%±4.2% of normal side; all showed significant difference when compared with preoperative ones (P<0.05). According to the Gartland and Werley score, the results were excellent in 15 cases, good in 6 cases, fair in 2 cases, and poor in 2 cases at last follow-up; the excellent and good rate was 84%. Conclusion By the good design of the volar locking plate and the command of surgical techniques, good effectiveness can be achieved in the treatment of senile delayed distal radius fracture.

    Release date:2017-07-13 11:11 Export PDF Favorites Scan
  • APPLICATION OF MINIMALLY INVASIVE LOCKING COMPRESSION PLATE IN TREATMENT OF DISTAL TIBIA FRACTURES

    Objective To evaluates the appl ication of minimally invasive plate osteosynthesis (MIPO) technique in treatment of distal tibia fractures with locking compression plate (LCP). Methods From August 2002 to August 2007, 62 subjects were recruited (36 males and 26 females) at mean age of 44 years old (range, 21-87 years old). According to AOclassification, there were 8 cases of type A1, 15 cases of type A2, 9 cases of type A3, 7 cases of type B3, 11 cases of type C1, and 12 cases of type C2. Of them, 52 patients had closed fractures and 10 had open fractures. Ten open fractures included 6 Grade I fracture and 4 Grade II fracture. The time from injury to operation was 8 hours to 6 days. The X-ray films were taken after 3 months of operation. Results Near anatomical reduction was achieved in 56 fractures and acceptable reduction in 6 fractures. Mean operation time was 43 minutes (range, 37-120 minutes). Primary heal ing of surgical wounds was observed in all cases. Subjects were followed up for 23 months on average (ranged, 18-45 months). All fractures healed with a mean heal ing time of 19.5 weeks (range, 16-32 weeks). According to Teeny and Wiss ankle scoring system, 30 patients got excellent results, 25 good, and 7 fair; and the excellent and good rate was 88.7% at 12-month follow-up. There were 7 cases of delayed soft tissue infection which needed implant removal. There was one compl ication of compartment syndrome which required fasciotomy. There was one case with loss of reduction (valgus tilting of tibial plafond) that required bone grafting. Conclusion The results of MIPO LCP in treatment of distal tibia fractures were satisfactory. This technique was safe with no incidence of serious compl ications.

    Release date:2016-09-01 09:08 Export PDF Favorites Scan
  • 锁定加压接骨板治疗Pilon骨折

    【摘要】 目的 总结锁定加压接骨板治疗Pilon骨折的疗效。 方法 2004年1月-2008年6月,将48例Pilon骨折患者随机分为急诊手术组和延期手术组,急诊手术组于伤后12 h之内手术,延期手术组于受伤7 d后手术。 结果 经过治疗所有患者骨折复位满意,无血管、神经损伤发生,无内固定物断裂、螺丝钉进入关节间隙发生,无接骨板外露、感染等早期并发症,两组优良率无统计学意义(Pgt;0.05);急诊手术组平均住院时间、消肿时间、骨折愈合时间均显著少于延期手术组,有统计学意义(Plt;0.05)。 结论 采用锁定加压接骨板治疗Pilon 骨折可取得满意的疗效,只要正确选择手术时机,术中精细的操作,可防治并发症。

    Release date:2016-09-08 09:51 Export PDF Favorites Scan
  • Treatment options and research progress of proximal tibial extra-articular fractures

    Objective To review the main fixation methods for proximal tibial extra-articular fractures based on clinical and biomechanical results, and to provide evidence for clinical application. Methods Extensive literature search at home and abroad was conducted in recent years, and external fixation systems such as external fixation braces and external locking plates, as well as internal fixation systems such as plates and intramedullary nails, were systematically reviewed regarding their application indications, clinical efficacy, and biomechanical results in proximal tibial extra-articular fractures. Results External fixation systems have advantages in fractures with open or severe soft tissue injury, facilitating wound management and maintaining stability of the fracture site to some extent. However, in proximal tibial extra-articular fractures with good soft tissue conditions, internal fixation systems such as plates and intramedullary nails are still the first choice. Some studies have found that intramedullary nails allow patients to bear weight early, with shorter fracture healing time and higher rate of malunion, while other studies have found that both intramedullary nails and plates have similar clinical efficacy and can achieve satisfactory treatment results. Conclusion The choice of fixation method for proximal tibial extra-articular fractures depends not only on the type of fracture, but also on the surgeon’s habits and operational skills. Larger-scale studies are still needed to clarify the advantages and disadvantages of intramedullary nails and locking plates in the treatment of proximal tibial extra-articular fractures.

    Release date: Export PDF Favorites Scan
  • MODIFIED Stoppa APPROACH WITH MEDIAL WALL SPRING PLATE FOR INVOLVING QUADRILATERAL OF ACETABULUM FRACTURE

    ObjectiveTo investigate the effectiveness of modified Stoppa approach with medial wall spring plate (MWSP) for involving quadrilateral of acetabulum fracture. MethodsBetween March 2008 and September 2013, 38 patients with involving quadrilateral of acetabulum fracture were treated, including of 23 males and 15 females with an average age of 36.08 years (range, 19-56 years). The causes included traffic accidents injury (21 cases), crash injury of heavy object (10 cases), and falling injury from height (7 cases). The interval of injury and admission was 3 hours to 2 days (mean, 11 hours). There were 12 cases of anterior column fracture (type D), 5 cases of transverse fractures (type E), 8 cases of T shaped fractures (type H), 6 cases of anterior column fracture with posterior transverse fractures (type I), and 7 cases of double column fractures (type J) according to Letournel-Judet classification. Based on fracture types, MWSP was used to fix fracture by modified Stoppa approach in 19 cases or combined with the ilioinguinal approach in 10 cases or combined with Kocher-Langenbeck approach in 9 cases. The operation time, blood loss, and complications were recorded. The effectiveness of reduction and the hip function were evaluated according to Matta score system and Merled' Aubigne and Postel score system. ResultsThe operation time was 85-210 minutes (mean, 130 minutes).The intra-operative blood loss was 450-900 mL (mean, 650 mL). There were 1 case of vascular avulsion, and 1 case of bladder injury during operation; there were 8 cases of venous thrombosis and 2 cases of fat liquefaction of incision after operation. Screw was implanted into the articular joint in 1 case on CT after operation. Matta X-ray assessment showed anatomical reduction in 9 cases, satisfactory reduction in 24 cases, and unsatisfactory reduction in 5 cases, and the satisfaction rate of reduction was 86.84%. Three patients had limb shorting of 0.8-1.0 cm when compared with normal limb. All patients were followed up for 7 to 18 months with an average of 10 months. Fractures healed well within 13-16 weeks with an average of 14 weeks. At 1 year after operation, the results were excellent in 9 cases, good in 21 cases, general in 5 cases, and poor in 3 cases, and the excellent and good rate was 78.95% according to the Merled'Aubigne and Postel hip score standards. ConclusionInvolving quadrilateral of acetabulum fracture can be fixed with MWSP by modified Stoppa approach or combined with other approaches to obtain good exposure, less invasion, satisfactory reduction, stable fixation, and low complications.

    Release date: Export PDF Favorites Scan
  • DEVELOPMENT OF POLYAXIAL LOCKING PLATE SCREW SYSTEM OF SACROILIAC JOINT

    ObjectiveTo develop an instrument for sacroiliac joint fixation with less injury and less complications. MethodsFirstly, 18 adult pelvic specimens (8 males and 10 females) were used to measure the anatomical data related to the locking plates and locking screws on the sacrum and ilium, and the polyaxial locking plate screw system of the sacroiliac joint was designed according to the anatomic data. This system was made of medical titanium alloy. Then 4 adult male plevic specimens were harvested and the experiment was divided into 3 groups:group A (normal pelvic), group B (the dislocated sacroiliac joint fixed with sacroiliac screws), and group C (the dislocated sacroiliac joint fixed with polyaxial locking plate screw system). The vertical displacement of sacroiliac joint under the condition of 0-700 N vertical load and the horizontal displacement on angle under the condition of 0-12 N·m torsional load were compared among the 3 groups by using the biological material test system. Finally, the simulated application test was performed on 1 adult male cadaveric specimen to observe soft tissue injury and the position of the locking plate and screw by X-ray films. ResultsAccording to the anatomic data of the sacrum and ilium, the polyaxial locking plate screw system of the sacroiliac joint was designed. The biomechanical results showed that the vertical displacement of the sacroiliac joint under the condition of 0-700 N vertical load in group A was significantly bigger than that in group B and group C (P < 0.05), but there was no significant difference between group B and group C (P>0.05). The horizontal displacement on angle under the condition of 0-12 N·m torsional load in group A was significantly less than that in group B and group C (P < 0.05). The horizontal displacement on angle under the condition of 0-6 N·m torsional load in group B was bigger than that in group C, and the horizontal displacement on angle under the condition of 6-12 N·m torsional load in group B was less than that in group C, but there was no significant difference between group B and group C (P>0.05). The test of simulating application showed that the specimen suffered less soft tissue injury, and this instrument could be implanted precisely and safely. ConclusionThe polyaxial locking plate screw system of the sacroiliac joint has the advantages of smaller volume and less injury; polyaxial fixation enables flexible adjustment screw direction. The simulated application test shows satisfactory fixing effect.

    Release date: Export PDF Favorites Scan
  • TREATMENT OF FRACTURES OF PROXIMAL RADIUS WITH Ni-Ti SHAPE MEMORY ALLOY EMBRACING FIXATOR

    Objective To find out an ideal method of internal fixation for the treatment of fractures of proximal radius. Methods From August 2001 to April 2004, 24 patients suffering from fractures of proximal radius were treated with NiTi shape memory alloy embracing fixator. Of 24 patients, there were 19 males and 5 females, aging from 16 to 48 years; there were 9 cases of wrestling injury, 5 cases of crush injury, 4 cases of traffic accident injury, 3 cases of direct violence impact injury and 3 cases of high falling injury. All patients were given operation according to fix method of the shape memory alloy embracing fixator. All cases were regularly followed up to observe the fracture healingand functional recovery. Results All cases were followed up postoperatively from 4 months to 21 months with an average of 10 months. No complication occurred during operation and after operation. Healing by first intention was achieved. X-ray showed that all cases achieved clinical union 8-12 weeks after operation. According to Anderson’scriteria and the results were excellent in 18 cases, good in 5 cases, and fairin 1 case. The excellent and good rate was 95.83 %.  Conclusion The internal fixation with shape memory alloy embracing fixator has as follows adventages: less trauma, esay-to-do, stable fixation, better tissue compatibility and less complication in treating fractures of proximal radius. This method can enhance the fracture healing and functional recovery. So it is a better method to treat fractures of proximal radius.

    Release date:2016-09-01 09:25 Export PDF Favorites Scan
  • APPLICATION OF MINIMALLY INVASIVE LOCKING COMPRESSION PLATE IN TREATMENT OF PROXIMAL HUMERAL FRACTURES

    Objective To evaluate the cl inical and radiological outcomes of minimally invasive plate osteosynthesis (MIPO) with locking compression plate (LCP) in the treatment of proximal humeral shaft fracture. Methods From July 2004 to April 2008, 26 patients with displaced fractures of the proximal humeral shaft were recruited, including 8 males and 18 females. Age of patients averaged 66 years old (range, 34-82 years old). According to AO classification, there were 4 cases of type A1, 2 cases of type A2, 8 cases of type B1, 4 cases of type B2, 2 cases of type B3, 4 cases of type C1 and 2 cases of type C2. The time from injury to surgery averaged 2 days (range, 1-5 days). There were 8 osteoporotic fractures. Results All surgical wound healed primarily, and there was no wound infection. Three patients had postoperative radial nerve neurapraxia, which recovered at 4, 6, 8 months respectively. All patients were followed up for 6-24 months with an average of 14.1 months. Radiological examination revealed bony union within 6 months in 25 cases. There was 1 delayed union which remained asymptomatic and eventually healed at 8 months with acceptable Constant-Murley score. There were 3 cases of shoulder impingement syndrome diagnosed at 3 months post-operatively. After implant removal, they all achieved an acceptable Constant-Murley score. According to Constant-Murley scoring system, there were 11 excellent, 10 good and 5 acceptable results. The excellent or good rate was 80.8%. Conclusion MIPO technique using LCP is an effective method to treat proximal humeral shaft fractures, which facil itates functional recovery of the shoulder joint. During the surgery, it is important to achieve a good fracture reduction and to avoid compl ications.

    Release date:2016-09-01 09:08 Export PDF Favorites Scan
  • Efficacy comparison of different methods to treat femoral intertrochanteric fracture in aged patients

    ObjectiveTo compare the efficacy of proximal femoral nail anti-rotation (PFNA), locking compression plate (LCP), and artificial femoral head replacement for femoral intertrochanteric fracture in aged patients so as to provide reference for clinical treatment.MethodsA retrospective analysis was made on the clinical data of 150 aged patients with femoral intertrochanteric fracture treated between September 2009 and March 2016. PFNA was used in 51 cases (group A), LCP in 53 cases (group B), and artificial femoral head replacement in 46 cases (group C). There was no significant difference in sex, age, side, cause of injury, injury to operation time, type of fracture, and combined medical diseases between groups (P>0.05). The incision length, operation time, intraoperative blood loss, time for full weight bearing, hip Harris score, and complications were recorded and compared between groups.ResultsThe patients were followed up 12-23 months (mean, 18.6 months) in group A, 12-25 months (mean, 19.0 months) in group B, and 12-24 months (mean, 18.9 months) in group C. The incision length, operation time, and intraoperative blood loss of group A were significantly less than those of groups B and C (P<0.05); the operation time of group C was significantly shorter than that of group B (P<0.05), but there was no significant difference in incision length and intraoperative blood loss (P>0.05). The time for full weight bearing was significantly shorter in group C than groups A and B, and in group A than group B (P<0.05). Postoperative complications occurred in 11 patients of group A (21.6%), 14 patients of group B (26.4%), and 2 patients of group C (4.3%), showing significant difference between group C and group A or group B (P<0.05), but no significant difference was found between groups A and B (P>0.05). Hip Harris score at 12 months after operation had no significant difference between groups (P>0.05).ConclusionPFNA, LCP, and artificial femoral head replacement are all effective methods to treat femoral intertrochanteric fracture in aged patients. PFNA has the advantages of small incision, short operation time, less bleeding and simple procedure, and artificial femoral head replacement has the advantages of early time for full weight bearing, less bed rest time, and less complications. For these patients, PFNA and artificial femoral head replacement are appropriate.

    Release date:2017-06-15 10:04 Export PDF Favorites Scan
4 pages Previous 1 2 3 4 Next

Format

Content