目的:分析长期机械通气患者脱机成败原因,提高脱机成功率。方法:针对本院2003年5月至2008年10月近6年ICU172例长期机械通气患者成败原因进行分析。结果:总脱机成功率90.69%。脱机失败率 9.31%。结论:长期机械通气患者多存在多种因素的共同参与,如营养不良、全身衰弱、呼吸功能不全、通气泵衰竭和心理因素等,增加了脱机的难度,进而出现撤机困难。
ObjectiveTo evaluate the predictive value of diaphragmatic rapid shallow breathing index (D-RSBI) for weaning outcome prediction.MethodsThis was a prospective observation study. Respiratory rate (RR) and tidal volume (Vt) were recorded at the end of spontaneous breathing trial, and both M-Mode and B-Mode ultrasonography were used to assess the right diaphragmatic displacement (DD). In parallel, outcome of the weaning attempt, length of mechanical ventilation, length of stay in intensive care unit (ICU) and mortality of ICU were recorded. According to the weaning outcome, the patients were grouped into the successful group and the failed group. The receiver operator characteristic (ROC) curve was used to assess the value of rapid shallow breathing index (RSBI, RR/Vt) and D-RSBI (RR/DD) in predicting weaning failure for ICU patients with mechanical ventilation.ResultsA total of 110 patients recruited in this study. Of them, 73 (66.4%) patients were successfully liberated from mechanical ventilation, and 37 patients failed (33.6%) weaning procedure. The RSBI and D-RSBI of the patients in the failed group were higher than those in the success weaning group (P<0.01). The area under the ROC curves of RSBI and D-RSBI for predicting weaning failure was 0.78 (95% confidence interval 0.69 - 0.87), 0.91 (95% confidence interval 0.85 - 0.97), respectively, a cutoff of RSBI>69 breaths/(L·min) yielded sensitivity of 55% and specificity of 89%, and a cutoff of D-RSBI>1.5 breaths/(min·mm) yielded sensitivity of 87% and specificity of 80%.ConclusionD-RSBI is more accurate than traditional RSBI in predicting the weaning outcome.
ObjectiveTo improve the understanding of prolonged weaning. MethodsA clinical case of prolonged weaning who had been successfully weaned from mechanical ventilation was retrospectively analyzed. The related literature was also reviewed. ResultsThe patient received invasive mechanical ventilation for 5 months,diagnosed as ventilator-associated pneumonia,type Ⅱrespiratory failure,Green-Barry syndrome,hypoproteinemia,anemia,and electrolyte disorder. Through the control of infection,nutritional support,psychological counseling,the patient was weaned from ventilator gradually and succeeded eventually. ConclusionsProlonged weaning is relatively difficult and wastes a long time. Professional treatment team and specialized treatment room are necessory. There are few reports about prolonged weaning.
ObjectiveTo compare the predictive values of dynamic energy expenditure (EE) monitoring and the traditional method (rapid shallow breath index) for weaning in patient who is suitable for weaning from mechanical ventilation and accepts sequentially reduced support of ventilator.MethodsThis study included a total of 93 patients who were admitted to the Department of Intensive Care Medicine in 2018 to 2019, and were eligible for weaning from mechanical ventilation. The energy expenditure monitoring device of GE ventilator (CARESCAPE R860) was used to record the patient's change rate of EE [δEE(%), T1 (PSV 20/5), T2 (PSV 15/5), T3 (PSV 10-5/5), T4 (PSV 5/5)] while the ventilation support was declined. The differences in δEE were compared between the two groups of patients who were successful weaned (a successful group S) or failed (a failed group) at different phases. The receiver operator characteristic (ROC) curve was used to analyze the predictive value of δEE to the success rate of weaning.ResultA total of 36 patients failed weaning procedure. There was no significant difference in the basic status and disease type between the successful group and the failed group. There was no difference in δEE1 between T1-T2 phases [(5.67±2.31)% vs. (6.40±1.90)%, P>0.05], but significant difference in δEE between T2-T3 and T3-T4 phases [δEE2: (11.35±5.39)% vs. (14.21±6.33)%, P<0.05; δEE3: (8.39±3.90)% vs. (17.32±9.07)%, P<0.05]. The area under the ROC curve predicted by δEE2 and δEE3 for the patient's weaning results was higher than rapid shallow breath index (0.83 and 0.75 vs. 0.64, P<0.05).ConclusionDynamic energy expenditure monitoring can effectively evaluate and predict the success rate of weaning from mechanical ventilation, and can be applied to the clinical treatment process.
Objective To investigate whether the respiratory support weaning based on adaptive support ventilation ( ASV) could reduce the duration of mechanical ventilation in patients after fast-track coronary artery bypass grafting ( CABG) . Methods After CABG during the same fast-track general anesthesia, 46 patients were randomly assigned to an ASV group or a synchronized intermittent mandatory ventilation ( SIMV) group as control. The duration of mechanical ventilation, hemodynamic parameters, and airway pressures were recorded. Meanwhile, the variables and the number of the arterial blood gas were recorded. Results The duration of mechanical ventilation was shorter in the ASV group than that in the control group [ 196( 152-286) ] min vs. 253( 196-498) min, P lt;0. 05] . The duration of ICUstay was shorterin the ASV group than that in the control group [ ( 14. 5 ±0. 7) h vs. ( 16. 8 ±0. 4 ) h, P lt;0. 01] . Fewer arterial blood analyses were performed in the ASV group than those in the control group [ 5 ( 4-7) vs.7( 6-9) , P lt; 0. 05] . Conclusions A ventilation weaning protocol based on ASV is practicable. It may accelerate tracheal extubation, shorten the length of ICU stay, and simplify ventilation management in patients after fast-track CABG.
ObjectiveTo evaluate the predictive value of the diaphragm ultrasound for weaning from mechanical ventilation.MethodsThe patients who received mechanical ventilation in Fujian Provincial Hospital between February 2016 to December 2017 and met the criteria for a T-tube spontaneous breathing trial were included in the study. Then right diaphragmatic displacement (DD) and diaphragmatic thickening fraction (DTF) were evaluated using M-mode ultrasonography as well as the rapid shallow breathing index (RSBI, the ratio of respiratory rate to tidal volume). A new index was named as the diaphragmatic-RSBI (D-RSBI, the ratio of respiratory rate to DD). The patients were classified into a success group or a failure group according to the weaning outcomes. The receiver operating characteristic (ROC) curves were calculated to evaluate the predictive performance of each index.ResultsFifty-nine patients were weaned successfully and failure of weaning was found in 29 patients. There were no statistically significant differences in pre-weaning parameters including age, sex, systolic blood pressure, diastolic blood pressure, blood lipid index (total cholesterol, low-density lipoprotein cholesterol, high-density lipoprotein cholesterol, triglyceride), or fast blood glucose between the weaning success group and the weaning failure group (P>0.05), but there were statistically significant differences in body mass index and acute physiology and chronic health condition Ⅱ score between two groups (P<0.05). DD [(13.44±3.23)mm vs. (10.28±2.82)mm, DTF [(32.43±12.35)% vs. (27.64±5.77)%, P<0.05] and D-RSBI [(1.49±0.47) breaths·min–1·mm–1 vs. (2.55±0.87) breaths·min–1·mm–1, P<0.05] differed significantly between the weaning success group and the weaning failure group. A cutoff of DTF≥27.9% yielded a sensitivity of 98.3%, a specificity of 62.1%, and an area under the ROC curve (AUC) of 0.873. A cutoff of D-RSBI≤1.73 breaths·min–1·mm–1 yielded a sensitivity of 76.3%, a specificity of 93.1%, and an AUC of 0.887. By comparison, when RSBI was ≤50.9 breaths·min–1·mm–1, there was a sensitivity of 91.5%, a specificity of 86.2%, and an AUC of 0.927. There was no statistically significant difference in AUC between D-RSBI and RSBI (P>0.05).ConclusionsDiaphragm ultrasound is feasible to predict the outcome of weaning. DTF and D-RSBI are as same accurate as the traditional RSBI in predicting the weaning outcome, but more objective and suitable for clinical application.
Objective To investigate the changes of hemodynamics in patients weaning intra-aortic balloon pump (IABP) by using progressive volume deflation followed by rate reduction. Methods We retrospectively analyzed the clinical data of 36 patients aged 68.9±4.7 years, 22 males and 14 females, who underwent progressive volume deflation followed by rate reduction for IABP weaning in Xinhua Hospital between September 2006 and January 2016. Progressive volume deflation followed by rate reduction was used to wean IABP and collect hemodynamics parameters of each time point. Results All the patients successfully weaned IABP. One patient got re-IABP assistant 36 hours after the first successful weaning. One early death and three patients (8%) with postoperative IABP-related complications were embolization of the toe artery. One was in ipsilateral limb, and two of contralateral limb. One patient with acute hepatic insufficiency and one patient with acute renal insufficiency cured after treatment. Conclusion Intra-aortic balloon pump weaning is successful by using volume deflation followed by rate reduction which allowed better hemodynamic parameters.