west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "测试" 37 results
  • Testing System Design and Analysis for the Execution Units of Anti-thrombotic Device

    In an anti-thrombotic pressure circulatory device, relays and solenoid valves serve as core execution units. Thus the therapeutic efficacy and patient safety of the device will directly depend on their performance. A new type of testing system for relays and solenoid valves used in the anti-thrombotic device has been developed, which can test action response time and fatigue performance of relay and solenoid valve. PC, data acquisition card and test platform are used in this testing system based on human-computer interaction testing modules. The testing objectives are realized by using the virtual instrument technology, the high-speed data acquisition technology and reasonable software design. The two sets of the system made by relay and solenoid valve are tested. The results proved the universality and reliability of the testing system so that these relays and solenoid valves could be accurately used in the anti-thrombotic pressure circulatory equipment. The newly-developed testing system has a bright future in the aspects of promotion and application prospect.

    Release date:2021-06-24 10:16 Export PDF Favorites Scan
  • Acute zonal occult outer retinopathy

    Acute zonal occult outer retinopathy (AZOOR) is an acquired retinal diseases. The majority of patients who develop AZOOR are women characterized by an acute onset of visual blurred and scotoma with photopsias. The fundus examination is often normal or appeared mild abnormal. The RPE atrophy of fundus is similar with white syndrome. Although FFA and ICGA features are either unremarkable or unrelated to AZOOR, there are still important in differential diagnosis. The characteristic abnormalities appearance of FAF (complicated and varied), OCT (regional anomaly of ellipsoid zone), visual field (visual field defect) and ERG (decreased amplitude and prolonged latency of rod reaction, maximum reaction, cone reaction and scintillation reaction) are considered critical examinations to the diagnosis of AZOOR. Although there is no effective therapy for AZOOR, it has some self-limitation.

    Release date:2019-05-17 04:15 Export PDF Favorites Scan
  • Development of Muscle Strength Evaluating System Based on Mobile Platform

    The development of muscle strength evaluating system based on Android system was developed in this research. The system consists of a lower unit and an intelligent mobile terminal. The pressure sensor of the lower unit was used to collect muscle strength parameters. And the parameters were sent to the Android device through the wireless Bluetooth serial port. Then the Android device would send the parameters to the doctor monitored platform through the Internet. The system realized analyzing the muscle strength parameters and real-time displaying them. After it ran on the Android mobile phones, it showed an effective result which proved that the system combined with mobile platform could make more convenient for the patients to assess their own muscle strength. It also provided reliable data references for doctors to know the patients' rehabilitation condition and to make the next rehabilitation plan.

    Release date: Export PDF Favorites Scan
  • Investigation of Typanometric Norms of Preschool Children

    目的 研究学龄前儿童鼓室图测试的正常值及其影响因素。 方法 2005年1月-2005年3月,对132名(223耳)学龄前儿童(4~6岁)进行单频率单成分鼓室图测试(Y-226),获取峰值处补偿静态声导纳(Ytm)、外耳道等效容积(Vea)、鼓室测量宽度(TW)和峰值处鼓室压(TPP)等数据,对不同年龄、性别及与国外研究的结果进行比较。 结果 不同年龄间只有TW存在差别;男童Vea大于女童,其他几项指标没有性别差异;Ytm、Vea、TW、TPP与国外正常值范围相比,有统计学意义(Plt;0.05)。 结论 单频率单成分鼓室图测试结果与国外研究相比有统计学意义,提示必须建立国人自己的正常鼓室图参考值标准。

    Release date:2016-09-08 09:49 Export PDF Favorites Scan
  • 等速肌力测试和训练技术在我国康复医学领域应用现状

    【摘要】等速肌力测试与训练技术是目前国际上最先进的肌力测试、训练方法,在国际康复医学领域已有相当广泛的运用,并日益受到重视,但在国内的相关研究较少,查阅近年来国内有关等速技术的文章,总结分析等速技术在我国目前的应用现状。

    Release date:2016-08-26 02:21 Export PDF Favorites Scan
  • Research progress of optical coherence tomography combined with microperimetry in diabetic macular edema

    Diabetic macular edema is the major cause of vision impairment in patients with non-proliferative diabetic retinopathy. Thickness and pathological alterations in each retina layer of diabetic macular edema (DME) patients can be performed by optical coherence tomography (OCT) device. And retinal light sensitivity at specific retinal point and fixation state can be detected by microperimetry qualitatively and quantitatively. Moreover, OCT can discover pathological anatomical changes in the retina of DME patients, thus facilitating the interpretation of the structure-function relationship in DME with combination of microperimetry results. At present, there are various therapies for DME patients, and the primary method in evaluating therapeutic efficacy is to compare the pathological changes in the retina before and after treatment by OCT. Besides, microperimetry can provide information in visual function restoration. The combined application of OCT and microperimetry has broad prospects in the diagnosis and treatment of DME patients.

    Release date:2018-07-23 04:02 Export PDF Favorites Scan
  • Rudiment Research and in Vitro Evaluation of a New Improvement Single Layer Suture Stentless Porcine Aortic Bioprosthesis

    Objective To design a novel stentless porcine aortic bioprosthesis and test the feasibility and its function in vitro after the valve was implanted by a modified method. Methods Six stentless porcine aortic bioprosthesis were divided into two groups according to different implantation, single layer suture group: new improvement stentless porcine aortic bioprosthesis sutured with single layer was implanted; double layer suture group: stentless porcine aortic bioprosthesis developmented by our laboratory used double layer suture was implanted. Each group contained three scales: 23 mm ,25 mm and 27 mm. Analogue ex vivo aortic valve replacement was performed , the feasibility of the new implantation was detected. Effective orifice area, transvalvular pressure gradient and regurgitation ratio were recorded at the cardiac output of 2.0 L/min, 3.5 L/min, 5.0 L/min and 7.0 L/min under the guideline of International Organization for tandardization (ISO)5840. Results The average aortic valve implantation time used for single layer suture and tradition double layer suture were 50 min and 70 min respectively. The transvalvular pressure gradient in the single layer suture group were significantly lower than those in double layer suture group under the flow of 5.0 L/min in 23 mm valve and 27 mm valve (13.51±0.51 mm Hg vs. 14.44±0.99 mm Hg, 7.36±0.19 mm Hg vs. 7.53±0.28 mm Hg;P<0.01);and the effective orifice area in the single layer suture group were larger than those in double layer suture group in the same case(1.87±0.06 cm2 vs. 1.76±0.08 cm2, 2.26±0.07 cm2 vs. 2.16±0.05 cm2;P<0.01). There was no statistically difference in other parameters between both groups. Conclusion The novel design of new improvement stentless porcine aortic bioprosthesis used single layer suture has good hemodynamic characteristics as the nature structure . The modified suture method decrease the implantation time.Nemerical data of the evaluation in vitro show that the difference between single layer suture group and double layer suture group in effective orifice area,transvalvular pressure gradient and regurgitation ratio haveno statistical significance. This experiment is the foundation of the animal and clinical experiment in the future.

    Release date:2016-08-30 06:05 Export PDF Favorites Scan
  • In vitro experimental study on the mechanical properties of biodegradable polymer stents

    In vitro experimental test for mechanical properties of a vascular stent is a main method to evaluate its effectiveness and safety, which is of great significance to the clinical applications. In this study, a comparative study of planar, V-groove and radial compression methods for the radial support property test were performed, and the effects of compression rate and circumferential position on the test results were conducted. Based on the three-point bending method, the influences of compression rate and circumferential position on flexibility were also explored. And then a best test proposal was selected to evaluate the radial support property and flexibility of the three self-designed stents and the comparative biodegradable vascular stent (BVS) (BVS1.1, Abbott Vascular, USA) with different outside diameters of 1.4 mm, 1.7 mm and 2.4 mm. The results show that the developing trends of the compression load with the compression displacement measured by the three radial support property test methods are the same, but normalized radial force values are quite different. The planar compression method is more suitable for comparing the radial support properties of stents with different diameters and structures. Compression rate has no obvious effect on the testing results of both the radial support property and flexibility. Compression circumferential position has a great impact on testing radial support property with the planar or V-groove compression methods and testing flexibility with three-point bending method. The radial support properties of all the three self-designed stents are improved at a certain degree compared to that of the BVS stent. The study has better guide significance and reference value for testing mechanical properties of vascular stents.

    Release date:2019-08-12 02:37 Export PDF Favorites Scan
  • 发作性运动诱发肌张力障碍一例

    Release date:2016-09-07 02:38 Export PDF Favorites Scan
  • Chinese expert consensus on the standardized application of multi-luminance mobility test in clinical trials for inherited retinal dystrophy

    With the advancement of research on rare ocular diseases such as inherited retinal dystrophy (IRD) has advanced in recent years, especially breakthroughs in therapeutic approaches represented by cell and gene therapy, potential intervention strategies have emerged for these conditions. Establishing standardized endpoints and evaluation methods for visual function in patients with IRD has become crucial for assessing disease progression, safety, and therapeutic efficacy of innovative treatments. Best corrected visual acuity (BCVA) is widely recognized as one of the primary endpoints for assessing visual function. However, for IRD patients with severe rod photoreceptor dysfunction, who often present with profound low vision or even legal blindness, the applicability of BCVA as a traditional visual function indicator is limited. The multi-luminance mobility test (MLMT) has emerged as a functional visual assessment tool that evaluates the ability to navigate obstacle courses under varying illumination levels. By establishing graded evaluation standards, MLMT objectively quantifies the impact of lighting conditions on patients’ nobility and spatial orientation, providing a novel quantitative tool for assessing visual function in IRD clinical trials. Currently, there is a lack of unified and standardized guidelines for the use of MLMT in China, posing challenges to its implementation in practical clinical research. To address this, Ocular Fundus Disease Society of Chinese Medical Association and Chinese Medical Doctor Association convened a multidisciplinary team comprising clinical experts in genetic retinal diseases, statisticians, and optical specialists to investigate the current applications and technical characteristics of MLMT, ultimately formulating consensus recommendations for its use as a clinical trial endpoint for IRD gene therapies. This consensus aims to provide a set of MLMT operating norms applicable to China's national conditions, guide clinical practice and research in ophthalmology and related disciplines, and promote the standardization process of IRD clinical trials in China, so as to better serve the IRD patient population and promote the development of related fields.

    Release date: Export PDF Favorites Scan
4 pages Previous 1 2 3 4 Next

Format

Content