Forty two eyes of 37 coses of age-related macular degeneration with subretinal neovascularization were followed up for more than 5 yeors.Vision, fundus change and fluorescein angiograms were with electrical image analysis system. (Chin J Ocul Fundus Dis,1994,10:1-3)
The experiment performed on domestic pig, was designed to investigate the architecture of the stretching skin and the effect of tension traction on the wound closure. An 7 cm x 3.5 cm was drawn at a standard position. Drawing horizontal and vertical lines on the traction area, points of 1 cm apart were tattooed on the lines. A traction force measuring device was used to draw the wound edges together. Measurements of the distances between the points were made. An 7 cm x 10 cm wound was made on identical sites of each hind leg. In the experiment the traction tension was applied on the edges of wound immediately after the wound debridement. The results showed the stretched distance in the two areas was 5-7 times the width of the wound. The gain of skin from traction was 61-89 percent in the width of the wound. The wounds from traction five days could be closed 5 days after traction. It was concluded that the skin which could be used for traction was abundant. Wound closure with the skin traction technique had many advantages, such as rapid decreasing the size of wound and early closing of wound.
Objective To analyze the mean flow in left internal m am mary artery ( L IMA) graft and the influencing factors in off- pump coronary artery bypass grafting ( OPCAB) in the Chinese. Methods One hundred and eighty patients with OPCAB were studied.Transit- tim e flowmeter( TTFM) was utilized to measure and record the L IMA’s blood flow wave,pulsatility index( PI) ,value of mean flow,systolic and diastolic peak flow,vascular resistance,insufficiency ratio and mean blood pressure and to analyze the relationship between mean flow of LIMA and other factors. Results Total mean flow calculated from that of all patients was2 8.19± 2 .89ml/ min( 6 - 178 ml/ m in) .Majority m ean value ( 6 4 .4 % ) was in the range of 10 - 30 ml/ min.Statistics showed that mean flow was significantly related to systolic and diastolic peak flow and vascular resistance rather than the other factors( r=0 .75 , 0 .94 ,- 0 .95 ) . Conclusions For the Chinese,over 10 ml/ min mean flow of L IMA graftis acceptable and ov...更多er 2 2 ml/ min is satisfactory.The diastolic peak flow and vascular resistance are two most important factors in influencing mean flow.
To assess the rel iabil ity of diabetic cutaneous ulcer surface area (DCUSA) measurement usingdigital planimetry method (A) and transparency tracing method (B). Methods Images of diabetic cutaneous ulcers from35 inpatients with diabetic skin ulcers from September 2005 to April 2007 were taken by a digital camera once a week or twice a week over a period of 12 weeks, resulting in 305 photographs; the ulcers were traced on a grid with acetate wound tracings, simultaneously. A total of 305 pairs of DCUSA which were calculated respectively throughout digital camera combined with Image J medical imaging software and transparency tracing with grid sheet by two independent observers sequentially were obtained. The intraclass correlation coefficients (ICCs, one-way random effect model) was used as an indicator of chancecorrected agreement to estimate the relative rel iabil ity for the interobserver data. Multiple l inear regression analysis was also used to measure the relationship of these two methods. Results DCUSA obtained from method A and obtained from method B was (4.84 ± 7.73) cm2 and (5.03 ± 7.89) cm2, respectively; no significant difference was found (P gt; 0.05). ICCs was high (ICCs=0.949 for method B and 0.965 for method A), indicating that the relative rel iabil ity for the interobserver was excellent. The method A were highly correlated with measurements obtained from method B (r = 0.957, P lt; 0.05). Conclusion The digital planimetry method described in this study represents a simple, practical, without any wound damage and contamination, and inexpensive technique to accurately evaluate the areas of diabetic cutaneous ulcers. The photographic technique combined with Image J medical imaging software should be considered for wound measurement.
Objective To study the value of the clinical application of stereography and measurement of liver volume in cirrhotic patients with portal hypertension. Methods By use of the personal computer and the software of threedimensional reconstruction and measurement system of liver faultage photograph, the liver volume in vivo was successfully measured and the threedimensional image of the liver rebuilt in 46 posthepatitic cirrhotics who were selected for orthotopic liver transplantation and in 30 noncirrhotic controls, and comparison with the reference volume of recipient liver was obtained by means of water deplacement after transplantation. Results The liver volume of cirrhotic patients with portal hypertension measured by software and water deplacement was (983.33±206.11) cm3, and (904.93±209.56) cm3 respectively. Comparison by means of linear regression analysis between volume measurement on threedimensional reconstruction software and reference volume showed a nearly ideal correlation coefficient(r=0.969,P<0.01), the average error was 8.66%.The average of liver volume in controls was (1287.00±96.18) cm3, and was positively correlated to the height,weight and body surface area (r=0.845,0.833,0.932 respectively,P<0.01),and was different from that of cirrhotics. Liver volume of cirrhoitic patients with portal hypertension was related to their ChildPugh classification. The liver volume of patients in Child C group was significantly smaller than that of patients of Child B group, and was significantly correlated with Alb (r=0.496, P<0.01) and TBIL(r=-0.493, P<0.01),PT(r=-0.517, P<0.01), but was not significantly correlated with ALT(r=0.206,Pgt;0.05),portal pressure(r=-0.093,P=0.539) and portosystemic shunt index (r=0.044,P=0.769). Conclusion The volume measurement of the liver by the threedimensional software is relatively accurate. Liver volume of cirrhotic patients with portal hypertension was significantly related to their liver function,and can reflect the liver reserve function.
Objective To investigate and analyze the three-dimensional anatomic structure of glenoid bone in some Chinese people so as to provide the accurate anatomic data to design the new prosthesis of glenoid bone for Chinese people. Methods A total of 90 volunteers with two healthy shoulders (52 males and 38 females, aging 19-60 years with an average of 39.6 years) were selected. Five parameters were measured by use of three-dimensional computed tomography, volumerendering technique (VRT) and multiplanar reformation (MPR), including the maximum antero-posterior width (MAPW),antero-posterior radius of curvature (APROC), maximum supero-inferior height (MSIH), supero-inferior radius of curvature(SIROC) and version angle (VA) of glenoid. All parameters were measured two times, and the average values were analysed by SPSS13.0. The level of significance was set at P lt; 0.05. Results The average MAPW was (2.51 ± 0.32) cm, the average APROC was (5.50 ± 1.21) cm, the average MSIH was (3.45 ± 0.29) cm, the average SIROC was (3.98 ± 0.55) cm, and the average VA was (— 0.03 ± 4.66)°. There were no significant differences (P gt; 0.05) in MAPW, APROC, MSIH, SIROC and VA between two sides. There were significant differences (P lt; 0.05) in MAPW, MSIH, SIROC and VA, and no significant difference (P gt; 0.05) in APROC between female and male. MAPW was correlated with APROC, MAPW was correlated with MSIH, APROC was correlated with SIROC, and the correlation coefficient was 0.298, 0.495 and 0.262, respectively. Conclusion There are no significant differences in MAPW, APROC, MSIH, SIROC and VA of glenoid between two sides. There are sexual significant differences in MAPW, MSIH, SIROC and VA. The data and its statistical results may serve as guidel ines for the design of the glenoid component.