OBJECTIVE To study the biocompatibility of skin reproductive membrane. METHODS According to ISO’s standards, the extractions of the skin reproductive membrane were prepared, and the acute systematic toxicity test, primary skin irritant test, cytotoxicity test, gene expression of type I collagen and fibronectin were detected to evaluate the biocompatibility of skin reproductive membrane. RESULTS All of those tests showed negative results. CONCLUSION The skin reproductive membrane has excellent biocompatibility in the level of the systematic, cellular and molecular biology.
Objective To investigate the biocompatibility of diamond-like carbon(DLC) coated NickelTitanium shape memory alloy with osteoblasts cultured invitro. Methods Rabbit’s osteoblasts were incubated with DLCcoated NickelTitanium shape memory alloy disks and uncoated ones of equal size for 5 days. The control group(without shape memory alloy in culture media) was performed simultaneously. The cultured cells were counted and graphed. The samples from culture media were collected and the concentrations of alkaline phosphatase (ALP) and nickel(Ni2+) were measured from the 1st to 5th day respectively. Results The proliferation of osteoblasts and the concentration of ALP in both DLC-coated group and control gruop was higher than uncoated group. The proliferation of osteoblasts on the 3rd, 4th, and 5th day in both DLC-coatedgroup and control group was significantly higher than that in the uncoated group(P<0.05). The concentration of ALP in DLC-coated group on the 2nd, 3rd, and 5th day and in the control group on the 3rd, 4th, and 5th day was significantly higher than that in the uncoated group(P<0.05). The concentration of Ni2+ on the 3rd, 4th, and 5th day was significantly lower than that in the uncoated group(P<0.05). Conclusion DLC- coated NickelTitanium shape memory alloys appears to have better biocompatibility with osteoblast cultured in vitro compared to uncoated ones.
Objective To investigate the feasibility of a new kind of porous β tricalcium phosphate (β-TCP) as a scaffold for the bone tissue engineering Methods The inverted phase contrast microscope was used to observe the growth of the marrow mesenchymal stem cells (MSCs) in the experimentalgroup and the control group at 10 days.In the experimental group, the MSCs were cultured with β-TCP(3 mm×3 mm×3 mm) in the 24-hole cultivation board, and in the control to control group, only MSCs were cultivated. The scanning electron microscope was used to observe growth of MSCs at 6 days. Cultivated with β-TCP at 3, 6, 9, 12 days, the MTT assay was used to judge the biocompatibility. The cytotoxicity was analyzed with the method that used the different density(100%, 50%, 10%, 1%,0%) leaching liquor gained from β-TCP to raise MSCs. MSCs were induced into the osteoblasts and were mixed with β-TCP, and the composite was used to repair a large radius bone defect in the rabbit. The specimens were made at 2,6,12 weeks. The histology imageology, and the radionuclide bone scan were used to analyze the bone formation. Results Some MSCs had a good adherence 4 hours after MSCs were inoculated and had a complete adherence at 12 hours. The cells were shaped like polyangle, spindle or converge monolayer after 8-10 days. The cells in the two groups had no difference. The cell adhesion was good, when observed by the inverted phase contrast microscope and the scanning electron microscope at 6 days. MTT showed that the absorbance (A)was not statistically different between the experimental group and the control group (P>0.05); the different density leaching liquor had no cytotoxicity at the different time points. Histology, X-ray, and CT tomograph showed that itcould repair the large radius bone defect in the rabbit and its in vivo degradationrate was the same as the bone formation rate. Conclusion The new porous β-TCP has a unique three dimensional (3D) stereochemical structure and superordinary physicochemical property, and so it is a good scaffold for the bone tissue engineering.
As one of the stimulus-response polymeric intelligent materials, shape memory polymers have been widely applied in biomedicine due to their better biocompatibility, higher controllability, stronger deformation restorability and biodegradability compared with shape memory alloys and shape memory ceramics. This review will introduce the structural principles of shape memory polymers and summarize their applications in the treatment of vascular diseases, especially in endovascular therapy. At the same time, the related technical problems and the future of shape memory polymers are prospected. With the continuous development of processing technology and materials, it can be predicted that shape memory polymers will be more widely used in the medical field.
To explore the histological and the hematological change of rabbits after implanting novel injectable artificial nucleus prostheses, and to evaluate the biological safety. Methods In accordance with Biological Evaluation of Medical Devices, materials of polyurethane, sil icone rubber and macromolecular polyethylene for medical use were made into short column 1 cm in length and 0.3 cm in diameter. Forty-eight SPF New Zealand white rabbits weighing 2.5-3.0 kg were used, and cavity 1 cm in depth was made in the area 2 cm away from the spinal midl ine by separating muscle.Then according to different material being implanted, the rabbits were divided into 3 groups (n=16): Group A, polyurethane; group B, sil icone rubber; group C, macromolecular polyethylene for medical use as negative control. General condition of the rabbits was observed after operation. Gross and histology observation were conducted 1, 4, 12 and 26 weeks after operation. Blood routine, biochemical function and electrolyte assays were performed 26 weeks after operation to observe pathological changes of organs. Meanwhile, physicochemical properties of the materials were detected, and the material in the same batch was used as negative control. Results All rabbits survived until the end of experiment, and all wounds healed by first intention. In each group, red swollen muscles were observed 1 week after operation and disappeared 4 weeks after operation, connective tissue around the implanted materials occurred 12 and 26 weeks after operation. At 26 weeks after operation, there were no significant differences among three groups in blood routine, biochemical function and electrolyte assays (P gt; 0.05). Organs had smooth surface without ulceration, ecchymosis, obvious swell ing, hyperemia or bleeding, and nodules. There were no significant differences among three groups in percentage weight of each organ (P gt; 0.05). Histology observation: granulation tissue prol iferation and inflammatory cell infiltration were observed in each group 1 week after operation, fibrous capsule formation around the materials and the disappearance of inflammatory cell infiltration were evident 4 weeks after operation, cyst wall grewover time and achieved stabil ity 12 weeks after operation. The inflammatory response and the fiber cyst cavity of groups A and B met the standard of GB/T 16175 and were in l ine with group C. No specific pathological changes were discovered in the organs 26 weeks after operation. For group A, no significant difference was evident between before and after material implantation in terms of weight average molecular weight, number average molecular weight, tensile strength at break and elongation at break (P gt; 0.05). For group B, no significant difference was evident between before and after material implantation in shore hardness (P gt; 0.05). Conclusion Novel injectable nucleus pulposus prostheses do not damage local tissue and function of organs, but provide good biocompatibil ity and biological safety.
Objective To investigate the effect of human tooth bone graft materials on the proliferation, differentiation, and morphology of macrophages, and to understand the biocompatibility and cytotoxicity of human tooth bone graft materials. Methods Fresh human teeth were collected to prepare human tooth bone graft materials, the adhesion of mouse mononuclear macrophages RAW264.7 to human bone graft materials was observed under confocal microscopy. Scanning electron microscopy was used to observe the morphology of human tooth bone graft materials, OSTEONⅡ synthetic highly resorbable bone grafting materials, and untreated tooth powder (dental particles without preparation reagents). Different components of the extract were prepared in 4 groups: group A (DMEM medium containing 10% fetal bovine serum), group B (human tooth bone graft materials), group C (OSTEONⅡ synthetic highly resorbable bone grafting materials), group D (untreated tooth powder without preparation reagents). The 4 groups of extracts were co-cultured with the cells, and the cytotoxicity was qualitatively determined by observing the cell morphological changes by inverted microscope. The cell proliferation and differentiation results and cell relative proliferation rate were determined by MTT method to quantitatively determine cytotoxicity. The cell viability was detected by trypanosoma blue staining, and tumor necrosis factor α (TNF-α ) and interleukin 6 (IL-6) expressions were detected by ELISA. Results Scanning electron microscopy showed that the surface of the human tooth bone graft material and the OSTEONⅡ synthetic highly resorbable bone grafting materials had a uniform pore structure, while the untreated tooth particle collagen fiber structure and the demineralized dentin layer collapsed without specific structure. Confocal microscopy showed that the cells grew well on human tooth bone graft materials. After co-culture with the extract, the morphology and quantity of cells in groups A, B, and C were normal, and the toxic reaction grades were all grade 0, while group D was grade 3 reaction. MTT test showed that the cytotoxicity of groups B and C was grade 0 or 1 at each time point, indicating that the materials were qualified. The cytotoxicity was grade 2 in group D at 1 day after culture, and was grade 4 at 3, 5, and 7 days. Combined with cell morphology analysis, the materials were unqualified. The trypanosoma blue staining showed that the number of cells in groups A, B, and C was significantly higher than that in group D at each time point (P<0.05), but no significant difference was found among groups A, B, and C (P<0.05). ELISA test showed that the levels of TNF-α and IL-6 in groups A, B, and C were significantly lower than those in group D (P<0.05), but no significant difference was found among groups A, B, and C (P<0.05). Conclusion The human tooth bone graft materials is co-cultured with mice mononuclear macrophages without cytotoxicity. The extract has no significant effect on cell proliferation and differentiation, does not increase the expression of inflammatory factors, has good biocompatibility, and is expected to be used for clinical bone defect repair.
Objective To evaluate the biocompatibility of a new bone matrix material (NBM) composed of both organic and inorganic materials for bone tissue engineering. Methods Osteoblasts combined with NBM in vitro were cultured. The morphological characteristics was observed; cell proliferation, protein content and basic alkaline phosphatase(ALP) activity were measured. NBM combined with osteoblasts were implanted into the skeletal muscles of rabbits and the osteogenic potential of NBM was evaluated through contraat microscope, scanning electromicroscope and histological examination. In vitro osteoblasts could attach and proliferate well in the NBM, secreting lots of extracellular matrix; NBM did not cause the inhibition of proliferation and ALP activity of osteoblasts. While in vivo experiment of the NBM with osteoblasts showed that a large number of lymphacytes and phagocytes invading into the inner of the material in the rabbit skeletalmuscle were seen after 4 weeks of implantation and that no new bone formation was observed after 8 weeks. Conclusion This biocompat ibility difference between in vitro and in vivo may be due to the immunogenity of NBM which causes cellular immuno reaction so as to destroy the osteogenic environment. The immunoreaction between the host and the organic-inorganic composite materials in tissue engineering should be paid more attention to.
ObjectiveTo study the biocompatibility of bioprosthetic heart valve material with a non-glutaraldehyde-based treatment, and to provide the safety data for the clinical application. MethodsAll the tests were conducted according to GB/T16886 standards. The in vitro cytotoxicity was determined by methyl thiazolyl tetrazolium assay. Fifteen guinea pigs were divided into a test group (n=10) and a control group (n=5) in the skin sensitization test. Three New Zealand white rabbits were used in the intradermal reactivity test. Five sites on both sides of the rabbit back were set as test sites and control sites, respectively. In the acute systemic toxicity test, a total of 20 ICR mice were randomly assigned to 4 groups: a test group (polar medium), a control group (polar medium), a test group (non-polar medium) and a control group (non-polar medium), 5 in each group. Forty SD rats were divided into a test group (n=20) and a control group (n=20) in the subchronic systemic toxicity test. ResultsThe viability of the 100% extracts of the bioprosthetic heart valve material with a non-glutaraldehyde-based treatment was 75.2%. The rate of positive reaction was 0.0%. The total intradermal reactivity test score was 0. There was no statistical difference in the body weight between the test group and control group in the acute systemic toxicity test. There was no statistical difference in the body weight, organ weight, organ weight/body weight ratio, blood routine test or blood biochemistry between the test group and control group in the subchronic systemic toxicity test. ConclusionThe bioprosthetic heart valve material with a non-glutaraldehyde-based treatment has satisfying biocompatibility, which conforms to relevant national standards. The material might be a promising material for application in valve replacement.
Objective To explore the clinical application value of mineralized collagen (MC) bone scaffolds in repairing various types of skull defects, and to assess the suitability and repair effectiveness of porous MC (pMC) scaffolds, compact MC (cMC) scaffolds, and biphasic MC composite (bMC) scaffolds. Methods A retrospective analysis was conducted on the clinical data of 105 patients who underwent skull defect repair with pMC, cMC, or bMC between October 2014 and April 2022. The cohort included 63 males and 42 females, ranging in age from 3 months to 55 years, with a median age of 22.7 years. Causes of defects included craniectomy after traumatic surgery in 37 cases, craniotomy in 58 cases, tumor recurrence or intracranial hemorrhage surgery in 10 cases. Appropriate MC scaffolds were selected based on the patient’s skull defect size and age: 58 patients with defects <3 cm² underwent skull repair with pMC (pMC group), 45 patients with defects ≥3 cm² and aged ≥5 years underwent skull repair with cMC (cMC group), and 2 patients with defects ≥3 cm² and aged <5 years underwent skull repair with bMC (bMC group). Postoperative clinical follow-up and imaging examinations were conducted to evaluate bone regeneration, the biocompatibility of the repair materials, and the occurrence of complications. Results All 105 patients were followed up 3-24 months, with an average of 13 months. No material-related complication occurred in any patient, including skin and subcutaneous tissue infection, excessive ossification, and rejection. CT scans at 6 months postoperatively showed bone growth in all patients, and CT scans at 12 months postoperatively showed complete or near-complete resolution of bone defects in all patients, with 58 cases repaired in the pMC group. The CT values of the defect site and the contralateral normal skull bone in the pMC group at 12 months postoperatively were (1 123.74±93.64) HU and (1 128.14±92.57) HU, respectively, with no significant difference (t=0.261, P=0.795). Conclusion MC exhibits good biocompatibility and osteogenic induction ability in skull defect repair. pMC is suitable for repairing small defects, cMC is suitable for repairing large defects, and bMC is suitable for repairing pediatric skull defects.
Silicon carbide (SiC) film and silicon dioxide (SiO2) film were deposited on the surface of carbon/carbon composite (C/C) by low pressure chemical vapor deposition (LPCVD). The biocompatibility of the three carbon-based composites, e. g. C/C, C/C-SiC, C/C-SiO2 were investigated by cytotoxicity test, cell direct contact and cell adhesion experiments. Cytotoxicity, cell direct contact and cell adhesion showed that the three materials had no toxic effect on mouse fibroblasts (L929 cells). However, the particles dropped off from the three materials had a great impact on evaluation accuracy of the thiazolyl blue (MTT) test. More the particles were lost, more growth inhibition to L929 cells. The evaluation accuracy of MTT method can be kept with the filtered extract of materials. Furthermore, the results of surface particles shedding experiment showed that the amount of surface particles shed from C/C-SiO2 was the most, followed by C/C and C/C-SiC in 72 hours. Particles shedding curves showed there was a peak reached at eighth hour and then declined to the thirty-sixth hour. The filtrate analysis showed that there was no ion exchange between the three materials and simulated body fluid (SBF) solution. The results of this study on biocompatibility of carbon-based composites have certain guiding significance for their future application in clinical filed.