Objective To investigate the value of monitoring cytokines in serum after human doublehand allotransplantation. Methods We detected solube interleukin-2 receptor(sIL-2R), interleukin-2(IL-2) and interleukin-6(IL-6) levels of the serum in the patient who were performed doublehand transplantation with immunosupressive from September 2000 to November 2000, and in15 healthy volunteers by using enzyme linked immunosorbent assays. Results TheIL-2 and IL-6 levels decreased quickly during inducing period (P<0.05), and then increased gradually. While the sIL-2R level increased. The IL-2 level was lower(P<0.05), the IL-6 and sIL-2R levels were slightly higher when compared with those before transplantation. There was significant difference in the IL-2level between the patient and healthy volunteers both before and after transplantation, in the IL6 level between the patient and healthy volunteers during inducing period.Conclusion IL-2, IL-6 and sIL-2R levels of serum may be useful in diagnosis of rejection, prevention of opportunistic infection, tumor and graft versus host disease.
Objective To investigate the biocompatibil ity of sil ica gel embedded permanent magnets of themicturition alert device dedicated to neurogenic bladder. Methods According to the national standards of biologicalevaluation of medical equipment (GB/T 16886), Shanghai Biomaterial Research and Test Center was confided to evaluate the biocompatibil ity of sil ica gel embedded permanent magnets both in vitro and in vivo, including cytotoxicity test, sensitization test, primary skin irritant test and acute general toxicity test. The cytotoxicity test was performed according to the agar diffusion method. The L929 cell discoloration index and cell lysis index were counted at 24 hours after the action of the specimen. The sensitization test was performed according to the maximal dose method. The skin response was evaluated in 30 male albino guinea-pigs at 24 and 48 hours after the routine induction and provocation of leaching l iquors of the specimen. The primary skin irritant test was evaluated in 2 male healthy New Zealand rabbits according to the local tissue response at 24, 48 and 72 hours after intradermal injection of leaching l iquors of the specimen. The acute general toxicity test was evaluated in 10 male Kumming mice musculus albus according to animal condition at 4, 24, 48 and 72 hours after injection of leaching l iquors of the specimen through the caudal vein. Both the general reaction of canines and the pathology of the local bladder walls were observed at 2, 4 and 8 weeks after a permanent magnet was fixed on the anterior wall of urinary bladder in three canines. Results No sensitization, no stimulation and no acute general toxicity were observed except sl ight cytotoxicity to sil ica gel embeddedpermanent magnets. After implantation of a permanent magnet, the canines showed excellent tolerace, which manifested as no abnormal ity in spirit, appetite, urine and stool, healed wounds and no infection. Adhesions occurred between the epiploon and the bladder wall around the permanent magnet in two canines at 2 and 4 weeks, and between the lower abdominal wall and the bladder wall around the permanent magnet in the other canine at 8 weeks. The local bladder wall below permanent magnet was thickened, the fibrous capsule around the permanent magnet was thin, but the bladder mucosa was normal. Inflammatory reaction such as congestion, edema and inflammatory cells lessened from the serosa layer to the mucosa layer microscopically. Conclusion Sil ica gel embedded permanent magnets used in the micturition alert device dedicated to neurogenic bladde has excellent biocompatibil ity and meet the criteria for cl inical appl ication.
Venous pressure monitoring is an important indicator for the arteriovenous fistula evaluation. Direct static venous pressure monitoring is recognized as the most accurate way of venous pressure monitoring, which is widely used in the functional monitoring, functional evaluation of arteriovenous fistula, the diagnosis of complications and the evaluation of surgical efficacy. Venous pressure monitoring has obvious advantages and disadvantages, so it is necessary to improve relevant knowledge to correctly guide clinical diagnosis and treatment. In this paper, the study of static venous pressure monitoring of arteriovenous fistula was summarized, in order to improve the understanding of the significance and clinical application of static venous pressure monitoring of arteriovenous fistula.
ObjectiveTo explore the application effect of standardized management on video-electroencephalogram (VEEG) monitoring.MethodsIn January 2018, a multidisciplinary standardized management team composed with doctors, technicians, and nurses was established. The standardized management plan for VEEG monitoring from outpatient, pre-hospital appointment, hospitalization and post-discharge follow-up was developed; the special quilt for epilepsy patients was designed and customized, braided for the patient instead of shaving head, standardized the work flow of the staff, standardized the health education of the patients and their families, and standardized the quality control of the implementation process. The standardized managemen effect carried out from January to December 2018 (after standardized managemen) was compared with the management effect from January to December 2017 (before standardized managemen).ResultsAfter standardized management, the average waiting time of patients decreased from (2.08±1.13) hours to (0.53±0.21) hours, and the average hospitalization days decreased from (6.63±2.54) days to (6.14±2.17) days. The pass rate of patient preparation increased from 63.14% to 90.09%. The capture rate of seizure onset increased from 73.37% to 97.08%. The accuracy of the record increased from 33.12% to 94.10%, the doctor’s satisfaction increased from 76.34±29.53 to 97.99±9.27, and the patient’s satisfaction increased from 90.04±18.97 to 99.03±6.51. The difference was statistically significant (P<0.05).ConclusionStandardization management is conducive to ensuring the homogeneity of clinical medical care, reducing the average waiting time and the average hospitalization days, improving the capture rate and accuracy of seizures, ensuring the quality of medical care and improving patient’s satisfaction.
Objective To summarize and analyze the different modality on molecular imaging of tracking and monitoring for islet transplantation.Methods The current domestic and foreign reports on molecular imaging of islet transplantation were reviewed.Results Magnetic resonance imaging has high sensitivity,high spatial resolution,no ionizing radiation,is clinically applicable,and could be used of real-time MR-guided injections,but can’t discriminate between liver and dead cells,difficult to do in patients with liver iron overload.Nuclear molecular imaging only displays liver cells generate signal,is clinically applicable,but disadvantage is genetic manipulation,ionizing radiation,no anatomical information,low spatial resolution.The advantage of in vivo optical imaging is only liver cells generate signal,widely available,no ionizing radiation,and the disadvantage is genetic manipulation,not clinically applicable,low spatial resolution.Conclusions Islet imaging using magnetic resonance,nuclear molecular imaging,in vivo optical imaging,or multimodal imaging of microencapsulated islets may provide us with a direct means to interrogate islet cell distribution,survival,and function.Multimodal imaging of microencapsulated islets may be best way for tracking and monitoring in the future.