Objective To observe effects of the direct impaction onthe cell survival and the bone formation of the tissue engineered bone modified by the adenovirus mediated human bone morphogenetic protein 2 (Adv-hBMP2) gene and to verify the feasibility of the impacted grafting with it. Methods The marrow stromal cells (MSCs) were separated from the canine bone marrow and were cultured. MSCs were transfected with the Adv-hBMP2 gene and combined with the freeze-dried cancellous bone (FDB) to form the tissue engineered bone. Four days after the combination, the tissue engineered bone was impacted in a simulated impactor in vitro and implanted in the mouse. The cell survivals were evaluated with SEM 1 and 4 days after the combination, immediately after the impaction, and 1 and 4 days after the impaction, respectively. The bone formation and the allograft absorption were histologically evaluated respectively. Results There were multiple layers of the cells and much collagen on FDB before the impaction. Immediately after the impaction, most of the cells on the direct contact area disappearedand there was much debris on the section. Some of the cells died and separatedfrom the surface of FDB at 1 day, the number of the cells decreased but the collagen increased on the surface at 4 days. Histologically, only the fibrous tissue was found in FDB without the cells, the bone formation on FDB was even in distribution and mass in appearance before the impaction, but declined and was mainly on the periphery after the impaction in the AdvhBMP2 modified tissue-engineered bone. Conclusion The simulated impaction can decrease the cells survival and the bone formation of the AdvhBMP-2 modified tissue-engineered bone. The survival cells still function well.It is feasible to use the tissue engineered bone in the impaction graft.
Objective To investigate bio characteristics of bone stromal cells (MSC) in different concentrations of alginate combined with xenograft. Methods The configuration and secretion of MSC in different concentrations of alginate combined with xenograft were observed by scanning electron microscope and inverted microscope. Results When the concentration of alginate was 0.25% or 1%, alginate was equally combined in xenograft, 4% and 8% only on the surface of xenograft. After cultured for 4 days, alginate of 0.25# came off from xenograft. But alginate of 1% was equally combined in xenograft with cell secreting well in alginate. The growth of cells in alginate of 4% was restricted and no cell was seen in alginate of 8%. Conclusion Alginate of 1% is suitable fro constructing carrier of tissue engineering bone.
Objective To investigate the morphology and biomechanics of in vivo osteogensis after repairing rabbit skull defects with plastic engineered bone which was prefabricated with alginate gel, osteoblasts and bone granules. Methods Twenty-eight rabbits were divided into group A (n=16), group B(n=8) and group C(n=4).The bilateral skull defects of 1 cm in diameter were made. Left skull defects filled with alginate gel-osteoblasts-bone granules(group A1) and right skull defects filled withalginate gel-bone granules(group A2).The defects of group B was left, as blank control and group C had no defect as normal control. The morphological change and bone formation were observed by methods of gross, histology and biomechanics. Results In group A1, the skull defects were almost entirely repaired by hard tissue 12 weeks after operation. The alginate gel-osteoblasts-bone granule material had changed into bone tissue with fewbone granules and some residuary alginate gel. The percentage of bone formation area was 40.92%±19.36%. The maximum compression loading on repairing tissue ofdefects was 37.33±2.95 N/mm; the maximum strain was 1.05±0.20 mm; andloading/strain ratio was 35.82±6.48 N/mm. In group A2, the alginate and bone granules material partially changed into bone tissue 12 weeks after operation. The percentage of bone formation area was 18.51%±6.01%. The maximum compression loading was 30.59±4.65 N; the maximum strain was 1.35±0.44 mm; and the loading/strainratio was 24.95±12.40 N/mm. In group B, the skull defects were mainly repaired bymembrane-like soft tissue with only few bone in marginal area;the percentage of bone formation area was 12.72%±9.46%. The maximum compression loading was 29.5±2.05 N; the maximum strain was 1.57±0.31mm;and the loading/strainratio was 19.90±5.47 N/mm.In group C, the maximum compression loading was 41.55±2.52 N; the maximum strain was 095±017 mm; and the l oading/strain ratio was 47.57±11.22 N/mm. 〖 WTHZ〗Conclusion〓〖WTBZ〗The plastic engineered bone prefabricated with algina te gelosteoblastsbone granule may shape according to the bone defects and ha s good ability to form bone tissue, whose maximum compression loading can reach 89 % of normal skull and the hardness at 12 weeks after operation is similar to that of normal skull.
OBJECTIVE: To compare the clinical results of repairing bone defect of limbs with tissue engineering technique and with autogeneic iliac bone graft. METHODS: From July 1999 to September 2001, 52 cases of bone fracture were randomly divided into two groups (group A and B). Open reduction and internal fixation were performed in all cases as routine operation technique. Autogeneic iliac bone was implanted in group A, while tissue engineered bone was implanted in group B. Routine postoperative treatment in orthopedic surgery was taken. The operation time, bleeding volume, wound healing and drainage volume were compared. The bone union was observed by the X-ray 1, 2, 3, and 5 months after operation. RESULTS: The sex, age and disease type had no obvious difference between groups A and B. all the wounds healed with first intention. The swelling degree of wound and drainage volume had no obvious difference. The operation time in group A was longer than that in group B (25 minutes on average) and bleeding volume in group A was larger than that in group B (150 ml on average). Bone union completed within 3 to 7 months in both groups. But there were 2 cases of delayed union in group A and 1 case in group B. CONCLUSION: Repair of bone defect with tissue engineered bone has as good clinical results as that with autogeneic iliac bone graft. In aspect of operation time and bleeding volume, tissue engineered bone graft is superior to autogeneic iliac bone.
OBJECTIVE: To construct tissue engineering bone with bio-derived materials and bone marrow stromal cells (MSCs), and to investigate the effect of allogeneic engineering bone implants on healing of segmental bone defects. METHODS: MSCs being aspirated aseptically from tibial tuberosities of young rhesus monkeys were induced into osteoblasts in vitro and then were cultured and marked with 5-bromo-2-deoxyuridine (BrdU). Tissue engineering bones were constructed with these labeled osteoblasts being seeded onto bio-derived materials made from fresh human bones which were treated physically and chemically, Then the constructs were implanted in 15 allogeneic monkeys to bridge 2.5 cm segmental bone defects of left radius as experimental groups, bio-derived materials only were implanted to bridge same size defects of right radius as control group. and, 2.5 cm segmental bone defects of both sides of radius were left empty in two rhesus monkeys as blank group. Every 3 monkeys were sacrificed in the 1st, 2nd, 3rd, 6th and 12th weeks postoperatively and both sides of the implants samples were examined macroscopically, histologicaly, and immunohistochemicaly. The two monkeys in blank group were sacrificed in the 12th week postoperatively. RESULTS: Apparent inflammatory reactions were seen around both sides of the implants samples in the 1st, 2nd, 3rd weeks, but it weakened in the 6th week and disappeared at the 12th week. The labeled osteoblasts existed at the 6th week but disappeared at the 12th week. The bone defects in experimental group were repaired and the new bone formed in multipoint way, and osteoid tissue, cartilage, woven bone and lamellar bone occurred earlier when compared with control group in which the bone defects were repaired in ’creep substitution’ way. The bone defects in blank group remained same size at the 12th week. CONCLUSIONS: Engineering bones constructed with bio-derived materials and MSCs were capable of repairing segmental bone defects in allogeneic monkeys beyond ’creep substitution’ way and making it healed earlier. Bio-derived materials being constituted with allogeneic MSCs may be a good option in construction of bone tissue engineering.
OBJECTIVE: To sum up the clinical results of bio-derived bone transplantation in orthopedics with tissue engineering technique. METHODS: From January 2000 to May 2002, 52 cases with various types of bone defect were treated with tissue engineered bone, which was constructed in vitro by allogeneous osteoblasts from periosteum (1 x 10(6)/ml) with bio-derived bone scaffold following 3 to 7 days co-culture. Among them, there were 7 cases of bone cyst, 22 cases of non-union or malunion of old fracture, 15 cases of fresh comminuted fracture of bone defect, 4 cases of spinal fracture and posterior route spinal fusion, 3 cases of bone implant of alveolar bone, 1 case of fusion of tarsotarsal joint. The total weight of tissue engineered bone was 349 g in all the cases, averaged 6.7 g in each case. RESULTS: All the cases were followed up after operation, averaged in 18.5 months. The wound in all the case healed by first intention, but 1 case with second intention. Bone union was completed within 3 to 4.5 months in 50 cases, but 2 cases of delayed union. Six cases were performed analysis of CD3, CD4, CD8, ICAM-1 and VCAM-1 before and after operation, and no obvious abnormities were observed. CONCLUSION: Bio-derived tissue engineered bone has good osteogenesis. No obvious rejection and other complications are observed in the clinical application.
Objective To explore the histological changes of bio-derived bone prepared by different methods after implantation, and to provide the scaffold material from xenogeneic animal for tissue engineering. Methods Theextremities of porcine femur were cut into 0.5 cm×0.5 cm×0.5 cm. Then they were divided into 5 groups according to different preparation methods: group A was fresh bone just repeatedly rinsed by saline; group B was degreased; group C was degreased and decalcificated; group D was degreased, acellular and decalcificated; group E wasdegreased and acellular. All the materials were implantated into femoral muscle pouch of rabbit after 25 kGy irradiation sterilization. The cell counting ofinflammatory cells and osteoclasts, HE and Masson staining, material degradation, collagen and new bone formation were observed at 2, 6, and 12 weeks postoperatively. Results The residue level of trace element in biomaterials prepared by different methods is in line with the standards. All the animals survived well. There were no tissue necrosis, fluid accumulation or inflammation at all implantation sites at each time point. The inflammatory cells counting was most in group A, and there was significant difference compared with other groups(P<0.05). There was no significant difference in osteoclasts counting among all groups. For the index of HE and Masson staining, collagen and new bone formation, groups C and D were best, group E was better, and groups A and B were worse. Conclusion The degreased, acellular and decalcificated porcine bone is better in degradation,bone formation, and lower inflammatory reaction, it can be used better scaffold material for tissue engineered bone.
Objective To study the culture and purification of the fetal mouse liver mesenchymal stem cells(MSCs) in vitro and to investigate their differentiation potential and the composite ability with true bone ceramic(TBC). Methods The single cell suspension of MSCs was primarily cultured and passaged, which was prepared from the fetal mouse liver; the flow cytometry was applied to detectCD29, CD34, CD44 and CD45. The osteogenic differentiation was induced in chemical inducing system; the osteogenic induction potency was tested. The purified fetal mouse liver MSCs were compounded with TBC covered with collagen type Ⅰ in vitro and the cell attachment and proliferation to the TBC were observed. Results The primary MSCs of fetal mouse liver were easy to culture in vitro. They proliferated well and were easy to subcultured. The proliferation ability of primary and passaged MSCs was similar. Flow cytometric analysis showed the positive results for CD29, CD44 and the negative results for CD34, CD45. After 7 days of induction, the MSCs expressed collagen type I and alkaline phosphatase(ALP) highly. After 14 days of induction, the fixed quantity of ALP increased significantly. After 28 days of induction, calcium accumulation was observed by Von Kossa’s staining. Many liver MSCs attached to the surface of TBC. Conclusion The MSCs of the fetalmouse liver can be obtained, subcultured and purified easily. After culturing in chemical inducing system, the MSCs of fetal mouse liver can be successfully induced to osteoblast-like cells, attach to the surface of TBC and proliferate well.
Objective To study the vascularization of the compositeof bio-derived bone and marrow stromal stem cells(MSCs) in repairing goat tibial shaft defect.Methods Bio-derived bone was processed as scaffold material. MSCs were harvested and cultured in vitro. The multiplied and induced cells were seeded onto the scaffold to construct tissue engineered bone. A 20 mm segmental bone defect inlength was made in the middle of the tibia shaft in 20 mature goats and fixed with plate. The right tibia defect was repaired by tissue engineered bone (experimental side), and the left one was repaired by scaffold material (control side).The vascularization and osteogenesis of the implants were evaluated by transparent thick slide, image analysis of the vessels, and histology with Chinese ink perfusion 2, 4, 6, and 8 weeks after operation.Results More new vessels were found in control side than in experimental side 2 and 4 weeks after implantation (Plt;0.05). After 8 weeks, there was no significant difference in number of vessels between two sides(Pgt;0.05), and the implants were vascularized completely. New bone tissue was formed gradually as the time and the scaffold material degraded quickly after 6 and 8 weeks in the experimental side. However, no new bone tissue was formed andthe scaffold degraded slowly in control side 8 weeks after operation.Conclusion Bio-derived bone has good quality of vascularization. The ability of tissue-engineered bone to repair bone defect is better than that of bio-derived bone alone.
OBJECTIVE: To explore a new method of preparing the composite of DL-polylactic acid (PDLLA), hydroxyapatite(HA), decalcium bone matrix (DBM), and to observe the degradation characteristics of PDLLA/HA/DBM in vitro. METHODS: An emulsion blend method was developed to prepare the composite of PDLLA/HA/DBM based on the weight rate of PDLLA:HA:DBM = 1.5-2:1-1.5:1. The characteristics of the particles was observed by scanning electron microscope. In vitro, PDLLA/HA/DBM and PDLLA were put into PBS(pH7.4) respectively; the pH value, weight and biomechanics of them were determined during the degradation. RESULTS: Without heating, the emulsion blend method could be developed to prepare PDLLA/HA/DBM. Scanning electron microscope showed that the gap diameter in the compound material was 100 to 400 microns, and the porosity was 71.3%; During degradation, the pH value of PDLLA decreased little within 2 weeks, then decreased obviously and decreased to 4.0 at the end of the 4th week; while the pH value of PDLLA/HA/DBM kept quite steady and was 6.4 at the end of the 12th week. The weight of PDLLA decreased little within 4 weeks, then decreased obviously and remained 50% of its prime weight at the end of the 12th week; while the weight of PDLLA/HA/DBM decreased little within 5 weeks, then decreased obviously and remained 60% of the prime at the end of the 12th week. The prime biomechanical strength was 1.33 MPa in PDLLA and 1.71 MPa in PDLLA/HA/DBM. There was significant difference between them (P lt; 0.05). The strength of PDLLA decreased little within 3 weeks, then decrease obviously and was 0.11 MPa at the end of the 12th week; the strength of PDLLA/HA/DBM decreased little within 4 weeks, then decrease obviously and was 0.21 MPa at the end of the 12th week. CONCLUSION: The emulsion blend method is a new method to prepare bone repair materials. As a new bone repair material, PDLLA/HA/DBM is suitable for bone tissue engineering for its good characteristics of porosity and degeneration.