west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "肱骨近端骨折" 29 results
  • 肱骨近端锁定钢板与传统钢板及交叉针治疗老年肱骨近端骨折的疗效比较

    【摘 要】 目的 比较采用传统钢板、交叉针及肱骨近端锁定钢板(1ocking plate of proximal humerus,LPHP)固定治疗老年肱骨近端骨折的疗效,为临床应用提供依据。 方法 2001 年5 月- 2006 年12 月,收治52 例老年骨质疏松且移位严重的肱骨近端骨折患者。采用LPHP 治疗25 例(LPHP 组),年龄59 ~ 76 岁。交通伤8 例,摔伤15 例,重物压伤2 例。Neer 分型二部分骨折4 例,三部分骨折13 例,四部分骨折8 例。采用传统钢板交叉针治疗27 例(传统钢板及交叉针组),年龄60 ~ 78 岁。交通伤6 例,摔伤18 例,重物压伤3 例。Neer 分型二部分骨折5 例,三部分骨折l6 例,四部分骨折6 例。术后采用SPADI 量表评分比较两组疗效。 结果 两组患者的一般资料及骨折类型差异无统计学意义(P gt; 0.05)。术后1 例切口感染,经处理后愈合,余患者切口均Ⅰ期愈合。两组患者均于术后3、6 及12 个月定期获随访。X 线片示传统钢板及交叉针组3 例于术后3 ~ 6 个月出现螺丝钉松动、滑脱;LPHP 组无。传统钢板及交叉针组3例骨折不愈合,余24 例均于术后4 ~ 7 个月获骨性愈合;LPHP 组25 例均于术后3 ~ 6 个月获骨性愈合。术后3、6 及12 个月行SPADI 量表评分,LPHP 组各时间点SPADI 评分均优于传统钢板及交叉针组,且总体评分差异有统计学意义(P lt; 0.05)。 结论 LPHP 治疗老年骨质疏松患者的肱骨近端骨折,较传统钢板及交叉针治疗有固定确切、功能锻炼早及并发症少的优点。

    Release date:2016-09-01 09:09 Export PDF Favorites Scan
  • EFFECTIVENESS OF LOCKING PLATES FOR Neer THREE- AND FOUR-PART PROXIMAL HUMERUS FRACTURES

    Objective To evaluate the effectiveness of locking plates for Neer 3- and 4-part proximal humerus fractures. Methods A retrospective analysis was made on the clinical data of 77 patients with 3- or 4-part proximal humerus fractures, who underwent open reduction and internal fixation of locking plates and were followed up more than 12 months between July 2008 and May 2011. There were 39 males and 38 females with an average age of 54.2 years (range, 18-81 years). Fractures were caused by falling in 47 cases, by traffic accident in 16 cases, by falling from height in 4 cases, by sporting in 5 cases, and by other reasons in 5 cases. The time between injury and operation was 2-16 days (mean, 4.5 days). According to Neer classification, there were 54 cases of 3-part fracture and 23 cases of 4-part fracture. The Constant scores, visual analogue score (VAS), and the complications were evaluated during follow-up. Results After operation, healing of incisions by first intention was obtained in 76 cases and healing by second intention in 1 case. All patients were followed up 12-36 months (mean, 18.5 months). At last follow-up, the Constant score was 71.1 ± 11.9; the results were excellent in 18 cases, good in 24 cases, fair in 25 cases, and poor in 10 cases with an excellent and good rate of 54.5%. The VAS score was 2.8 ± 2.2. Bone nonunion occurred in 2 cases; the other patients had bone union within 2-6 months (mean, 3.2 months). The complications occurred in 25 cases (32.5%). Revision surgery was performed in 15 patients (19.5%). Conclusion The treatment of Neer 3- and 4-part proximal humerus fractures remains challenging. Anatomic reduction, stable fixation, and reduced humeral head blood supply disruption may lead to a satisfactory outcome.

    Release date:2016-08-31 04:22 Export PDF Favorites Scan
  • Research progress on intra-articular screw penetration in proximal humeral fracture treated with locking plate

    ObjectiveTo review the research progress on intra-articular screw penetration in proximal humeral fracture treated with locking plate. MethodsThe domestic and foreign literature about the proximal humeral fracture treated with locking plate was extensively reviewed. The incidence of screw penetration and risk factors were summarized from both primary and secondary screw penetrations, and the reasons of the intra-articular screw penetration and the technical solutions to avoid the penetration were analyzed. ResultsThe incidence of intra-articular screw penetration is about 11%-30%, which includes primary and secondary screw penetrations. The primary screw penetration is related to improper operation, inaccurate measurement, and “Steinmetz solid” effect, which results in inadequate fluoroscopy and blind zone. The secondary screw penetration is related to the loss of reduction and varus, collapse, and necrosis of the humeral head. The risk factors for intra-articular screw penetration include the bone mass density, the fracture type, the quality of fracture reduction, the applied location, number, and length of the plate and screws, and whether medial column buttress is restored. Improved fracture reduction, understanding the geometric distribution of screws, good intraoperative fluoroscopy, and reconstruction of medial column buttress stability are the key points for success. ConclusionThe risk of the intra-articular screw penetration in the proximal humeral fractures treated with locking plates is still high. Follow-up studies need to further clarify the cause and mechanism of screw penetration, and the risk factors that lead to screw penetration, in order to effectively prevent the occurrence of this complication.

    Release date:2021-04-27 09:12 Export PDF Favorites Scan
  • DIFFERENT SURGICAL METHODS FOR TREATMENT OF SENILE OSTEOPOROTIC COMMINUTED PROXIMAL HUMERUS FRACTURE

    Objective To compare the efficacy and indication of the three different surgical methods in the treatment of the senile osteoporotic comminuted proximal humerus fracture. Methods From January 2006 to April 2008, 70 senile patients with osteoporotic comminuted proximal humerus fracture were randomly divided into three groups to receive different surgical methods. There were 21 patients in the group A receiving Kirschner tension band or screw internal fixation, 37 patients in group B receiving internal fixation of locking proximal humeral plate, and 12 patients in group C receiving humeral head replacement. There were 36 males and 34 females aged 53-76 years old (average 61.9 years old). All the fractureswere closed, osteoporotic, and III and IV-part according to Neer classification. The disease course was 1-8 days (average 2.8 days). There was no significant difference among three groups in terms of basel ine information (P gt; 0.05). The effective antiosteoporosis therapy was given during perioperative period. Results All the incision healed by first intention. All patients reached anatomical or almost anatomical reduction without compl ications such as postoperative infection, neurovascular injury, and nonunion of bone. Seventy patients were followed up for 9-20 months (average 11.5 months). The heal ing time of the fracture was 8-12 weeks in group A and group B, the average heal ing time was 10.5 weeks in group A and 10 weeks in group B, and there was no significant difference between two groups (P gt; 0.05). Group C presented with no sign of prosthesis loosening or shoulder dislocation. Six cases in group A suffered from frozen shoulder, pain or acromion impingement syndrome 6 months after operation and obtained various degrees of improvement via functional exercises. One of them had humeral head avascular necrosis 12 months later and achieved fair recovery after performing humeral head replacement. Two cases in group B had frozen and painful shoulder 6 months after operation and achieved fair recovery after functional exercises. One cases in group C had frozen shoulder and poor performance of abduction and upl ifting and achieved improvement after exercises. The rest patients achieved satisfactory curative effects. The incidence of compl ication was 28.6% in group A, 5.4% in group B, and 8.3% in group C. The incidence of complication in group A was significantly higher than that of group B and group C (P lt; 0.05), and there was no significant difference between group B and group C (P gt; 0.05). Neer scale system was adopted to evaluate the postoperative shoulder function, the excellent and good rate was 66.7% in group A, 78.4% in group B, and 83.3% in group C. The excellent and good rate in group A was significantly less than that of group B and group C (P lt; 0.05), and there was no significant difference between group B and group C (P gt; 0.05). Conclusion The senile osteoporotic comminuted proximal humerus fracture treated by surgery can obtain satisfied results. Most patients can use locking plate fixation. Those with poor general condition can use Kirschner wire fixation with tension band or screws, but this method is subject to certain constraints. For some elder patients with humeral head necrosis and humeral head crushed, priority should be given to the use of humeral head replacement.

    Release date:2016-09-01 09:08 Export PDF Favorites Scan
  • BIOMECHANICAL ANALYSIS OF STABILITY OF INTERNAL FIXATOR FOR PROXIMAL HUMERAL FRACTURES

    Objective To review the biomechanics of internal fixators for proximal humeral fractures, and to compare the mechanical stabil ity of various internal fixators. Methods The l iterature concerning the biomechanics of internal fixators for proximal humeral fractures was extensively analyzed. Results The most important things for best shoulder functional results are optimal anatomical reduction and stable fixation. At present, there are a lot of methods to treat proximal humeral fractures. Locking-plate exhibites significant mechanical stabil ity and has many advantages over other internal fixators by biomechanical comparison. Conclusion Locking-plate has better fixation stabil ity than other internal fixators and is the first choice to treat proximal humeral fractures.

    Release date:2016-09-01 09:04 Export PDF Favorites Scan
  • Risk Analysis of Locking Plate for 3-part or 4-part Proximal Humerus Fracture

    ObjectiveTo analyze the outcome and prognostic factors of using locking plate for treating proximal humerus fracture. MethodsBetween January 2005 and January 2012, 45 aged patients with a displaced 3-part or 4-part fracture of the proximal humerus were treated by locking plate. Range of motion and Constant-Mudey score were observed during the follow-up. ResultsForty-three patients were followed up from 12 to 48 months with an average of 18 months. The mean final Constant-Mudey score was 72.3±9.5 and 6 of them needed a second surgery. In addition to fracture type, other prognostic factors included redisplacement (4 cases, 9.3%), nonunion (3 cases, 7.0%), crashing (3 cases, 7.0%), necrosis of the humeral head (6 cases, 14.0%) and screw cut-out (5 cases, 11.6%). Among the patients with disrupted medial calcar, 4 needed a second surgery at the final follow-up, 3 had redisplacement, 2 had nonunion, and 2 had screw cut-out. ConclusionLocked screw-plates provide more secure fixation of fracture in aged patients, but the complication rate remains high. We suggest anatomic reduction, and plate and screws position, length of the screws, the medial cortical contact and stability may be the chief prognostic factors affecting the shoulder function following a proximal humeral fracture.

    Release date: Export PDF Favorites Scan
  • Two-stage reverse total shoulder arthroplasty for treating postoperative deep infection after internal fixation of proximal humeral fracture

    ObjectiveTo summarize the effectiveness of two-stage reverse total shoulder arthroplasty for treating postoperative deep infection after internal fixation of the proximal humeral fracture.MethodsBetween June 2014 and January 2018, 17 patients with deep infection and humeral head necrosis or bone nonunion after internal fixation of proximal humeral fractures were treated. There were 8 males and 9 females, aged from 52 to 78 years (mean, 63.8 years). The infection occurred at 19-66 months after the initial internal fixation (mean, 34.8 months). Microbial culture of joint fluid was positive in 14 cases and negative in 3 cases. The preoperative Constant score, American shoulder and elbow surgeons (ASES) score, and visual analogue scale (VAS) score were 36.41±8.65, 31.06±7.43, and 7.29±0.99, respectively. The preoperative ranges of forward flexion, abduction, external rotation were (45.88±12.46), (42.18±12.31), and (16.76±4.92)°, respectively. The preoperative range of internal rotation was buttock in 9 cases, lumbosacral joint in 3 cases, L3 in 5 cases. At the first-stage surgery, the thorough debridement was done and the antibiotic-impregnated bone cement spacer was placed after the removal of internal fixation. After the infections disappeared, the two-stage reverse total shoulder arthroplasty was performed. The mean interval between the two procedures was 4.2 months (range, 3.0-6.5 months).ResultsAll the incisions healed primarily and no complications such as recurrent infection or vascular nerve injury occurred. All patients were followed up 15-32 months (mean, 22.0 months). At last follow-up, the ranges of forward flexion, abduction, and external rotation were (109.00±23.66), (98.53±16.92), (41.41±6.82)°, respectively; and the range of internal rotation was lumbosacral joint in 5 cases, L3 in 8 cases, T12 in 4 cases. The range of motion of shoulder joints at last follow-up was significant improved when compared with the preoperative range of motion (P<0.05). The Constant score (64.88±8.70), ASES score (65.18±8.10), and VAS score (2.94±1.25) were significantly superior to the preoperative scores (P<0.05). X-ray films showed that no prosthesis loosening occurred.ConclusionTwo-stage reverse total shoulder arthroplasty is an effective treatment for the postoperative deep infection after internal fixation of the proximal humeral fracture, which has advantages of low risk of infection recurrence, good shoulder function, and satisfactory short-term effectiveness.

    Release date:2020-02-20 05:18 Export PDF Favorites Scan
  • Surgical Treatment versus Conservative Treatment for Three-part or Four-part Proximal Humeral Fractures in Elderly Patient:A Meta-analysis of Randomized Controlled Trials

    ObjectiveTo assess the effect of surgical treatment or conservative treatment on the clinical outcomes for displaced 3-part or 4-part proximal humeral fractures in elderly patients. MethodsWe searched CNKI (between January 1979 and April 2014), Wanfang Data (between January 1982 and April 2014), Medline (between January 1946 and April 2014), PubMed (between January 1966 and April 2014), Embase (between January 1974 and April 2014) and Cochrane Database of Systematic Reviews (between January 2005 and April 2014) for randomized controlled trials comparing surgical treatment and conservative treatment for displaced 3-part or 4-part proximal humeral fractures in elderly patients. The data were extracted and a Meta-analysis was made using RevMan 5.2. ResultsFive randomized controlled trials with a total of 226 patients were accepted in this Meta-analysis. The differences of Constant scores[WMD=0.48, 95%CI (-4.39, 5.35), P=0.85], incidences of avascular necrosisr of the humeral head[RR=0.66, 95%CI (0.37, 1.16), P=0.15], incidences of nonunion[RR=0.56, 95%CI (0.20, 1.58), P=0.27], incidences of osteoarthritis[RR=0.35, 95%CI (0.10, 1.22), P=0.10] between the two groups were not statistically different. The difference of incidences of additional surgery after primary treatment was statistically significant[RR=3.52, 95%CI (1.18, 10.45), P=0.02]. ConclusionThe results does not support the surgical treatment to improve the shoulder function when compared with conservative treatment for treating elderly patients with displaced 3-part or 4-part proximal humeral fractures. But surgical treatment increases the incidence of additional surgery after primary treatment. Considering surgery can increase the trauma and economic burden of patients, so the conservative treatment is suggested.

    Release date: Export PDF Favorites Scan
  • Comparison of locking plate and intramedullary nail in treatment of Neer two- and three-part fractures of the proximal humerus in the elderly

    Objective To compare the effectiveness of locking plate and intramedullary nail in treatment of Neer two- and three-part fractures of the proximal humerus in the elderly. Methods A retrospective analysis was conducted on 86 elderly patients with Neer two- and three-part fractures of the proximal humerus met the selection criteria between January 2015 and December 2018. Forty-six patients were treated with locking plate fixation (locking plate group), and 40 patients with intramedullary nail fixation (intramedullary nail group). There was no significant difference in gender, age, cause of injury, fracture side and type, time from injury to operation, and comorbidities between the two groups (P>0.05). Visual analogue scale (VAS) score, American Shoulder and Elbow Surgery (ASES) score, Constant-Murley score, and shoulder range of motion (forward flexion, abduction, and external rotation) were compared between the two groups. X-ray films were taken to assess the fracture healing, and the neck-shaft angle was measured at 2 days after operation and at last follow-up, and the difference between the two time points was calculated. Results Patients in both groups were followed up 18-40 months, with an average of 30.4 months. There was no significant difference in follow-up time between the two groups (t=−0.986, P=0.327). X-ray films reexamination showed that the fractures of two groups healed, and the healing time was (11.3±2.1) weeks in locking plate group and (10.3±2.0) weeks in intramedullary nail group, which had significant difference between the two groups (t=2.250, P=0.027). The difference of neck-shaft angle was (7.63±7.01)° in locking plate group and (2.85±2.82)° in intramedullary nail group, which had significant difference between the two groups (t=4.032, P<0.001). There was no significant difference in Constant-Murley score, ASES score, VAS score, and shoulder range of motion between the two groups at last follow-up (P>0.05). Complications occurred in 13 cases (28.3%) of locking plate group and in 4 cases (10.0%) of intramedullary nail group, and the difference between the two groups was significant (χ2=4.498, P=0.034). Conclusion Both locking plates and intramedullary nails can be used for the treatment of Neer two- and three-part fractures of the proximal humerus in the elderly. The intramedullary nail fixation surgery is more minimally invasive, which has fewer postoperative complications and faster fracture healing.

    Release date:2022-03-22 04:55 Export PDF Favorites Scan
  • TYPE C2 PROXIMAL HUMERAL FRACTURE FIXATION USING LOCKING-PLATE WITH AN INTRAMEDULLARY FIBULAR ALLOGRAFT

    ObjectiveTo investigate the clinical results of locking-plate with an intramedullary fibular allograft for type C2 proximal humeral fracture fixation. MethodsBetween January 2011 and August 2012, 16 patients with proximal humeral fractures (AO type C2) were treated by locking-plate with an intramedullary fibular allograft. The clinical data were retrospectively analysed. There were 5 males and 11 females with an average age of 64 years (range, 55-70 years). The injury causes were falling injury in 12 cases, traffic accident injury in 3 cases, and sports injury in 1 case. The duration between injury and operation ranged from 2 to 6 days (mean, 4.5 days). The imaging data were used to judge the fracture healing, and to measure the neck-shaft angle and the height of humeral head; the disability of arm, shoulder, and hand (DASH) score, short-form 36 health survey scale (SF-36), and Neer score were used to evaluate the function of the shoulder after surgery. ResultsPrimary healing of incision was obtained in all patients; no complication of vascular and nerve injury occurred. Sixteen cases were followed up 12-24 months (mean, 18 months). All fractures healed at 18-24 weeks (mean, 20 weeks). No complication occurred as follows:re-displacement, necrosis, rejection reaction, and loosening or extraction of screws. At last follow-up, the neck-shaft angle was 126.6-136.9° (mean, 132.5°), showing a little lost when compared with intraoperative angle (130.5-138.0°, 134.0° on average). At 12 months after surgery, the height loss of humeral head was 1.8-4.6 mm (mean, 2.0 mm); the passive anteflexion of the shoulder was 130-160° (mean, 148°); the active anteflexion was 120-145° (mean, 136°); the external rotation was 30-65° (mean, 56°); the internal rotation was 15-25° (mean, 19°). And the DASH score was 2-53 (mean, 12); the SF-36 score was 50-95 (mean, 89). According to Neer score for shoulder function, the results were excellent in 10 cases, good in 4 cases, fair in 1 case, and poor in 1 case, with an excellent and good rate of 87.5%. ConclusionLocking-plate with an intramedullary fibular allograft for type C2 proximal humeral fracture fixation has satisfactory clinical results because of stable fixation, high clinical outcome scores, and low internal fixation failure.

    Release date: Export PDF Favorites Scan
3 pages Previous 1 2 3 Next

Format

Content