Objective To summarize the experience of open heart operation on neonates with critical and complex congenital heart diseases and evaluate the methods of perioperative management. Methods From May 2001 to January 2003, 12 patients of neonates with congenital heart diseases underwent emergency operation. Their operating ages ranged from 6 to 30 days, the body weights were 2.8 to 4.5 kg. Their diagnoses included D-transposition of the great arteries in 4 cases, ventricular septal defect with atrial septal defect in 5 cases, complete atrioventricular septal defect, obstructed supracardiac total anomalous pulmonary venous drainage and cardiac rhabdomyomas in 1 case respectively. 12 cases were operated under moderate or deep hypothermic cardiopulmonary bypass. Results All cases were observed in ICU for 2-11 days and discharged 7-19 days after operation. The postoperative complications included low cardiac output, mediastinal infection, respiratory distress syndrome, systemic capillary leak syndrome and acute renal failure. All cases were cured and the follow-up (from 6 months to 2 years) showed satisfactory outcome. Conclusion A particular cardiopulmonary bypass and proper perioperative management is very important to ensure the successful outcome. Peritoneal dialysis is an effective and safe method for treating acute renal failure after cardiac operation in neonates.
ObjectivesTo explore the association between initial peritoneal transport characteristics and patient survival, and to evaluate the risk factors for mortality of continuous ambulatory peritoneal dialysis (CAPD) patients.MethodsBetween January 2011 and December 2016, the patients diagnosed with end stage renal disease commencing CAPD in West China Hospital were enrolled. According to the value of dialysate to plasma ratio for creatinine at 4 hour [D/P Cr (4 h)], CAPD patients were divided into two groups: the lower transport group [D/P Cr (4 h)<0.65] and the higher transport group [D/P Cr (4 h)≥0.65]. The survival of these two groups of peritoneal dialysis patients were plotted using survival analysis. CAPD patient outcomes were analyzed using multivariable Cox proportional hazards regression models.ResultsCompared with the lower transporter (n=246), higher transporter (n=345) were older, and with more peritoneal protein loss, lower level of serum albumin, lower level of hemoglobin, and less ultrafiltration (P<0.001). Higher transport group had lower survival rate compared to those in the lower transport group (P=0.001). The 1-, 3- and 5-year patient survival rates were 97.0%, 83.2%, and 71.7% in the higher transport group, and 98.7%, 93.9%, and 86.1% in the lower transport group, respectively. There was a positive relationship between D/P Cr (4 h) and serum peritoneal protein loss (P<0.001). D/P Cr (4 h) was inversely related to serum albumin (P<0.001). Cox regression analysis demonstrated that lower albumin [hazard ratio (HR)=0.921, 95% CI (0.885, 0.958), P<0.001], presence of cardiovascular disease [HR=1.996, 95% CI (1.256, 3.173), P=0.003], elder age [HR=1.049, 95% CI (1.033, 1.065), P<0.001], lower hemoglobin [HR=0.988, 95% CI (0.976, 1.000), P=0.044] and lower urea clearance index (KT/V)[HR=0.680, 95%CI (0.465, 0.994), P=0.046] could independently predicted mortality with significance in CAPD patients. But higher peritoneal transport was not a risk factor for mortality [HR=1.388, 95%CI (0.829, 2.322), P=0.212] in either model including serum albumin.ConclusionsFor CAPD patients, initial higher transporter had a higher mortality than lower transporter. However, initial higher peritoneal transport was not a risk factor for mortality independent of serum albumin in CAPD patients. Relationship between D/P Cr (4 h) and serum peritoneal protein loss and serum albumin suggests that higher peritoneal transport characteristics might worsen prognosis by lowering serum albumin level at initiation of peritoneal dialysis.
ObjectiveTo investigate the status of roxadustat in patients undergoing maintenance peritoneal dialysis and analyze the factors affecting drug compliance. MethodsPatients with renal anemia undergoing maintenance peritoneal dialysis in West China Hospital of Sichuan University from July 2020 to March 2021 were selected. All patients took roxadustat orally. According to the medication compliance, the patients were divided into good compliance group and poor compliance group. The general information questionnaire and Morisky Medication Adherence Scale-8 (MMAS-8) were used to investigate and analyze the included patients, and their clinical examination indexes were collected. ResultsA total of 100 patients were included, Including 39 cases (39%) in the good compliance group and 61 cases (61%) in the poor compliance group. The average score of medication compliance of roxadustat was 5.19±1.72. Logistic regression analysis showed that drug cognition [odds ratio (OR)=0.099, 95% confidence interval (CI) (0.027, 0.365), P=0.001], medication troubles/complex protocol [OR=5.330, 95%CI (1.567, 18.132), P=0.007], and adverse drug reactions [OR=5.453, 95%CI (1.619, 18.368), P=0.006] were factors affecting patient compliance. Hemoglobin in the good compliance group was lower than that in the poor compliance group (Z=−2.259, P=0.024); there was no significant difference in other clinical examination indexes (P>0.05). ConclusionsThe overall compliance of oral roxadustat in maintenance peritoneal dialysis patients is poor, and the corresponding follow-up management system should be improved. Nurses should provide comprehensive and systematic medication guidance to patients, encourage them to fully understand the clinical manifestations, treatment schemes and prognosis of renal anemia, clarify the time, dose, possible adverse reactions and mitigation methods of roxadustat, etc., and help them to treat the disease with correct cognition and attitude, so as to improve their drug compliance.
Objective To assess the cost-utility study of renal transplantation compared with nemodialysis (HD) and peritoneal dialysis (PD). Methods A prospective study of end-stage renal disease patients was followed up for 3 months after renal replacement therapy. The study population included 196 patients (renal transplant [RT] n=63, hemodialysis [HD] n=82 and continious ambulatory peritoneal dialysis [CAPD] n=51) from 6 hospitals of Sichuan province. Health-related quality of life was assessed by using the WHOQOL-BRIEF questionnaire. Utility scores were obtained so as to conduct CUA (cost-utility analysis). Costs were collected from financial department and by patient interview. Results The utility values were 0.539 9± 0.013 for RT, 0.450 8± 0.014 for HD, 0.512 2±0.099 for CAPD, respectively. The mean direct cost of the first three months of renal transplant was significantly higher than dialysis (RT and CAPD). Over 3 months, the average cost per quality-adjusted life year (QALY) for patients after CAPD was lower than HD and RT. Compared to HD, incremental cost analysis showed that CAPD was more ecnomical than RT. Sensitive analysis showed that CAPD was more effective than RT when ΔQALY varied in the limit of 95% confidence interval. However, the cost-utility of RT vs HD and CAPD vs HD was varied with ΔQALY level. Conclusions Cost-utility analysis showed that CAPD was a more favorable cost-utility ratio when compared to RT at early stage RT vs HD and CAPD vs HD, but which cost-utility ratio is better, we can not draw a certain conclusion.
目的:调查我院腹膜透析患者死亡和转HD治疗的原因及相关影响因素。方法: 收集腹膜透析患者在我院死亡14例,转HD治疗 2 6例;查阅40例患者在我院的完整病历资料,调查其死亡及转HD治疗的原因及感染病原菌、营养等指标。结果: 14例腹膜透析死亡患者主要原因为肺部感染合并心脑血管疾病及消化道出血,均占(29%,4/14)。643%(9 / 14)的死亡患者HBlt;90 g/L,ALBlt;30 g/l;71.4%(10 / 14)的腹膜透析死亡患者合并钙磷失调。 26例腹膜透析患者转HD的首要原因和次要原因分别为腹透相关性腹膜炎(50%,13/26)和透析液引流不畅(42%,11/26)。72.7%透析液引流不畅的腹透患者经影像学诊断漂管,27.3%患者为拔管手术证实网膜堵塞管口。结论: 1.肺部感染性疾病合并合并心脑血管系统及消化系统,为腹膜透析患者死亡的主要原因,与全身营养状况不良,钙磷失调有关。 2. 腹膜透析相关性腹膜炎仍为腹膜透析患者退出转HD治疗的主要原因。 3.因透析液引流不畅而拔管为转HD治疗的第二位原因,漂管和网膜阻塞管口为透析液引流不畅的原因。
ObjectiveTo observe the changes of blood flow density and perfusion density in the macula of non-diabetic peritoneal dialysis (PD) patients, and their correlation with blood pressure, total protein, albumin, prealbumin, serum creatinine, urea, and high-sensitivity C-reactive protein were preliminarily analyzed.MethodsA single-center, cross-sectional, clinical observational study. From January to December 2018, 63 eyes of 63 non-diabetic patients (non-diabetic PD group) and 75 eyes of normal healthy people (the normal control group) who underwent PD treatment at the PD Center of Peking University First Hospital were included in the study. All were monocular into the group. Among the 63 patients in the non-diabetic PD group, 24 were males and 39 were females. The duration of PD was 7 to 185 months, with the average duration of 67.87±48.36 months. There were 75 healthy persons in the normal control group. There was no significant difference in age (t=-0.558), sex ratio (χ2=0.492), axial length (t=-1.197), and BCVA between the two groups (P>0.05). OCT angiography was used to scan the macular area of 3 mm×3 mm and 6 mm×6 mm in the subject’s right eye. The blood flow density and perfusion density of superficial retinal capillaries in the macular area, as well as the area, circumference, and morphological index of the foveal avascular zone (FAZ) were measured. The blood flow density and perfusion density at different locations in the macular area of the two groups of eyes were compared by independent sample t test. The blood pressure, total protein, albumin, prealbumin, serum creatinine, urea, and high-sensitivity C-reactive protein was performed by Pearson correlation analysis.ResultsCompared with the healthy control group, the blood flow density and perfusion density of superficial retinal capillaries in the macular area of the non-diabetic PD group decreased in different scanning ranges with the macular vessel 3×3 center (t=-2.409), the macular vessel 3×3 macular (t=-2.423), macular vessel 3×3 intact (t=-2.759), macular vessel 6×6 intact (t=-1.882), macular vessel 6×6 outer layer (t=-2.188), macular perfusion 3×3 center (t=-1.990), macular perfusion 3×3 complete (t=-2.719), macular perfusion 6×6 complete (t=-2.113), and macular perfusion 6×6 outer layer (t=-2.205). The difference was statistically significant (P<0.05). The comparison of the macular FAZ area of the two groups of eyes was statistically significant (t=1.985, P<0.05). Correlation analysis showed that 3×3 macular blood vessels were intact and mean arterial pressure was positively correlated (r=0.256, P=0.043). The macular blood vessels were 3×3 intact, macular perfusion was 3×3 intact, and macular blood was 6×6 intact, which the pre-white protein was positively correlated with (r=0.468, 0.362, 0.333; P<0.001, P=0.004, 0.008). The macular vessel 3×3 was intact, the macular perfusion 6×6 was intact, which the hypersensitive C-reactive protein was negatively correlated with (r=-0.370, -0.287, P=0.005, 0.030).ConclusionThe superficial retinal blood flow density and perfusion density in the macular area of non-diabetic PD patients are lower than those of normal healthy people.
【摘要】 目的 探讨生理钙透析液对持续性不卧床腹膜透析(CAPD)患者钙磷代谢的影响。 方法 回顾性分析2008年1月-2009年12月腹膜透析患者的钙磷指标,资料齐全的患者中使用钙浓度为1.25 mmol/L的腹膜透析液(生理钙组)的患者有30例,使用钙浓度为1.75 mmol/L的透析液(标准钙组)患者30例。对两组患者钙磷代谢指标进行比较。 结果 治疗前后两组的血磷、钙磷乘积和全段甲状旁腺素差异均无统计学意义(Pgt;0.05);治疗后标准钙组血钙较前升高,差异有统计学意义(Plt;0.05),而生理钙组治疗前后血钙差异无统计学意义(Pgt;0.05)。 结论 不同含钙浓度腹膜透析液对机体钙磷代谢的影响是不同的,在高钙、高磷、低转运骨病的腹膜透析患者中使用钙浓度为1.25 mmol/L的生理钙透析液减轻了钙负荷,为临床医生使用含钙磷结合剂提供了治疗空间。【Abstract】 Objective To investigate the effects of physiological calcium dialysate on the calcium and phosphorus metabolism in patients undergoing continuous ambulatory peritoneal dialysis (CAPD). Methods We retrospectively analyzed the clinical data of 60 patients having undergone CAPD in West China Hospital of Sichuan University between January 2008 and December 2009. The patients were divided into two groups with 30 in each by calcium concentration of the dialysate: the physiological calcium dialysate group (1.25 mmol/L) and the standard calcium dialysate group (1.75 mmol/L). The metabolism indexes of calcium and phosphorus for the two group of patients were compared. Results Levels of Serum phosphate, calcium-phosphate product and immoreactive parathyroid hormone (iPTH) of all the patients in both groups before and after treatment showed no significant differences (Pgt;0.05). Serum calcium increased significantly in patients treated with standard calcium dialysate (Plt;0.05), while it did not change significantly in patients treated with physiological calcium dialysate (Pgt;0.05). Conclusions Dialysate with different concentrations of calcium provides different influence on the metabolism of calcium and phosphorus. Changing calcium concentration to 1.25 mmol/L in the dialysate can lower the calcium load for patients with hypercalcium and/or hyperphosphate with low bone turnover, providing treatment space for clinical doctors to use binders containing both calcium and phosphorus.