ObjectiveTo systematically review the effectiveness and safety of demethylation agents in patients with myelodysplastic syndrome. MethodsRandomized controlled trials (RCTs) about demethylation agents in treating myelodysplastic syndrome was electronically searched in PubMed, EMbase, The Cochrane Library (Issue 3, 2013), Web of Science, CNKI, VIP, WanFang Data and CBM from inception to March 2013. Two reviewers independently screened literature according to the inclusion and exclusion criteria, extracted data, and assessed methodological quality of the included studies. Meta-analysis was performed using RevMan 5.1 software. ResultsA total of 4 studies involving 816 patients were finally included. The results of meta-analysis showed that:for patients with myelodysplastic syndrome at middle/advanced stage, compared with the best supportive treatment plan, demethylation agents improved complete remission (CR) (OR=19.14, 95%CI 5.33 to 68.7, P < 0.000 01), partial remission (PR) (OR=20.63, 95%CI 5.76 to 73.93, P < 0.000 01), hematological improvement (HI) (OR=3.58, 95%CI 2.40 to 5.34, P < 0.000 01), and the incidences of Grade Ⅲ or Ⅳ neutropenia (OR=3.82, 95%CI 2.67 to 5.47, P < 0.000 01), Grade Ⅲ or Ⅳ thrombocytopenia (OR=3.98, 95%CI 2.55 to 6.23, P < 0.000 01), and mortalities (OR=0.52, 95%CI 0.35 to 0.77, P < 0.000 01), all with significant differences; and part of patients suffered from Grade Ⅲ or Ⅳ thrombocytopenia and tolerable adverse reaction caused by non-hematologic change. ConclusionCurrent evidence suggests that demethylation agents in treating myelodysplastic syndrome have apparently curative effects. Besides, it could prolong the time of turning into acute myelocytic leukemia, reduce mortalities, and improve patients' quality of life.
目的 探讨慢性阻塞性肺疾病(COPD)患者中微量元素铜和锌与炎症介质的关系。 方法 2010年11月-2011年3月间测量15例COPD急性加重期患者入院时及治疗后和13例健康者为对照组的血清铜、锌、C反应蛋白(CRP)、白介素-6(IL-6),血浆中金属硫蛋白,以及氧化应激产物丙二醛的浓度变化。并对铜、锌浓度变化与CRP、IL-6进行相关分析。 结果 COPD组血清中铜浓度、CRP、IL-6水平高于对照组(P<0.05),同时急性加重期患者血清中铜的浓度、CRP、IL-6水平以及丙二醛值高于缓解期患者(P<0.05)。而急性加重期患者血清中锌浓度低于缓解期组和对照组(P<0.05)。血浆中抗氧化物质金属硫蛋白在三组间差异无统计学意义(P>0.05)。在微量元素与炎症因子的相关分析中发现,铜与CRP(r=0.602,P<0.001)、IL-6(r=0.533,P<0.001)呈正相关,锌与IL-6呈负相关(r=?0.336,P<0.05)。 结论 在COPD氧化应激发病机制中,铜可能发挥促氧化应激的作用,而锌可能发挥抗氧化应激的作用。微量元素稳态的紊乱有可能是COPD急性加重的危险因素。
Motor imaging therapy is of great significance to the rehabilitation of patients with stroke or motor dysfunction, but there are few studies on lower limb motor imagination. When electrical stimulation is applied to the posterior tibial nerve of the ankle, the steady-state somatosensory evoked potentials (SSSEP) can be induced at the electrical stimulation frequency. In order to better realize the classification of lower extremity motor imagination, improve the classification effect, and enrich the instruction set of lower extremity motor imagination, this paper designs two experimental paradigms: Motor imaging (MI) paradigm and Hybrid paradigm. The Hybrid paradigm contains electrical stimulation assistance. Ten healthy college students were recruited to complete the unilateral movement imagination task of left and right foot in two paradigms. Through time-frequency analysis and classification accuracy analysis, it is found that compared with MI paradigm, Hybrid paradigm could get obvious SSSEP and ERD features. The average classification accuracy of subjects in the Hybrid paradigm was 78.61%, which was obviously higher than the MI paradigm. It proves that electrical stimulation has a positive role in promoting the classification training of lower limb motor imagination.
Brain-computer interface (BCI) system is a system that achieves communication and control among humans and computers and other electronic equipment with the electroencephalogram (EEG) signals. This paper describes the working theory of the wireless smart home system based on the BCI technology. We started to get the steady-state visual evoked potential (SSVEP) using the single chip microcomputer and the visual stimulation which composed by LED lamp to stimulate human eyes. Then, through building the power spectral transformation on the LabVIEW platform, we processed timely those EEG signals under different frequency stimulation so as to transfer them to different instructions. Those instructions could be received by the wireless transceiver equipment to control the household appliances and to achieve the intelligent control towards the specified devices. The experimental results showed that the correct rate for the 10 subjects reached 100%, and the control time of average single device was 4 seconds, thus this design could totally achieve the original purpose of smart home system.
Event-related desynchronization (ERD) is the basic feature of electroencephalogram (EEG), and the brain-computer interface based on motor imagery (MI-BCI) with the foundation of the analysis of ERD is of great significance in motor function recovery. The valid ERD characteristics extracted from EEG are the key to the performance of the BCI, so the study of which kind of stimulation mode can prompt subjects to generate more obvious characteristics of ERD is crucial. Four different stimulation modes are designed in this paper, and the effects of motion imagery tasks under static text stimulation, grip video stimulation, serial motion video stimulation of fingers as well as serial motion video stimulation of fingers with sound on the characteristics of ERD are analyzed. Combining the analysis of time-frequency spectrum, the power spectral density curve, ERD value and brain topographic map, it is shown that the ERD under serial motion video stimulation of fingers and serial motion video stimulation of fingers with sound modes is much stronger and has wider range of activation, and the BCI based on the analysis of ERD will have a better effect on practical application. As a result, the recognition and acceptance of the users of BCI system are improved in some extent.
Objective To systematically evaluate the diagnostic value of artificial intelligence assisted narrow-band imaging endoscopy diagnostic system for colorectal adenomatous polyps. Methods Pubmed, Embase, Web of Science, Cochrane Library, SinoMed, China National Knowledge Infrastructure, Chongqing VIP and Wanfang databases were searched. The diagnostic trials of the artificial intelligence assisted narrow-band imaging endoscopy diagnostic system for colorectal adenomatous polyps were comprehensively searched. The search time limit was from January 1, 2000 to October 31, 2022. The included studies were evaluated according to the Quality Assessment of Diagnostic Accuracy Studies-2, and the data were meta-analysed with RevMan 5.3, Meta-Disc 1.4 and Stata 13.0 statistical softwares. Results Finally, 11 articles were included, including 2178 patients. Meta-analysis results of the artificial intelligence assisted narrow-band imaging endoscopy diagnostic system for colorectal adenomatous polyps showed that the pooled sensitivity was 0.91, the pooled specificity was 0.88, the pooled positive likelihood ratio was 7.41, the pooled negative likelihood ratio was 0.10, the pooled diagnostic odds ratio was 76.45, and the area under the summary receiver operating characteristic curve was 0.957. Among them, 5 articles reported the diagnosis of small adenomatous polyps (diameter <5 mm) by the artificial intelligence assisted narrow-band imaging endoscopy diagnostic system. The results showed that the pooled sensitivity and the pooled specificity were 0.93 and 0.91, respectively, and the area under the summary receiver operating characteristic curve was 0.971. Five articles reported the accuracy of endoscopic diagnosis for adenomatous polyps of those with insufficient experience. The results showed that the pooled sensitivity and the pooled specificity were 0.84 and 0.76, respectively. The area under the summary receiver operating characteristic curve was 0.848. Compared with the artificial intelligence assisted narrow-band imaging endoscopy diagnostic system, the difference was statistically significant (Z=1.979, P=0.048). Conclusion The artificial intelligence assisted narrow-band imaging endoscopy diagnostic system has a high diagnostic accuracy, which can significantly improve the diagnostic accuracy for colorectal adenomatous polyps of those with insufficient endoscopic experience, and can effectively compensate for the adverse impact of their lack of endoscopic experience.