Objective To explore the feasibility of transcatheter closure of congenital heart disease (CHD) under the guidance of transthoracic echocardiography (TTE). Methods A total of 37 patients with CHD who received transcatheter closure under the guidance of transthoracic echocardiography from November 2013 through November 2015 in our hospital were recruited. There were 15 males and 22 females, aged 1 to 16 years. Among them 32 patients suffered atrial septal defect and 5 patients had patent ductus arteriosus. The transcatheter closure of CHD was performed under the guidance of TTE. The patients underwent echocardiography follow-up at one, three and six months after surgery. Results Closure devices were successfully implanted in 37 patients under TTE guidance. The procedure was simple and safe. During the follow-up, no severe complication such as valvular injury, pericardial effusion, residual shunt and peripheral vascular injury occurred. Conclusion Transcatheter closure of CHD under TTE guidance is a feasible method and worth further clinical application.
【摘要】随着超声心动图的普及与发展,无症状性类风湿性关节炎心脏瓣膜改变的检出率逐渐增多。临床应重视类风湿性关节炎心脏瓣膜损害以及超声心动图在这类疾病中的诊断价值,以期改善患者预后。【Abstract】 Objective More and more cardiac valve changes are detected in asymptomatic patients with rheumatoid arthritis by echocardiography. It is essential to pay attention to the clinical features of heart valves damage and the diagnostic value of echocardiography on that in order to improve the prognosis of patients.
肺动脉高压( pulmonary artery hypertension, PAH) 是右心衰竭的首要原因, 而右心衰竭又是 PAH 患者的重要致命因素, 及时而准确地对肺动脉高压患者的右心室功能做出评价, 对其病情评估、治疗决策和预后判断有重要的意义。近年来新发展的超声心动图二维应变及应变率技术、实时三维成像技术、Tei 指数及三尖瓣环收缩期位移等新技术弥补了传统超声评价右心功能的不足。本文就超声新技术在评价PAH 患者右心功能的应用做一综述。
Objective To investigate the correlation between the left atrial hydrodynamic change and atrial fibrillation (AF) in the patients with rheumatic mitral stenosis. Methods According to cardiac rhythm before operation, 49 patients with rheumatic mitral stenosis accompanying chronic AF were divided into two groups,group A: AF, 25 cases; group B: sinus rhythm, 24 cases. Control group : 29 healthy volunteers were examined. By using echocardiography, left atrial hydrodynamics were tested, and repeated 6-8 months after the operation. Results Left atrial stress (LAS), left atriala area (LAA) and left atrial volume(LAV) in group A after operation was much lower than before operation, LAS after operation in group B was also lower than before operation(Plt;0.01). Before operation, LAS in group A was significantly lower than that in group B, LAA and LAVwere larger. After operation, LAA and LAV in group A were significantly larger than those in group B(Plt;0.01). LAS, LAA and LAV in group A and group B before and after operation were higher than those in control group. Conclusion Left atrial hydrodynamic enviroment in patients with mitral stenosis has not reached normal even after valve replacement, LAS may be an important factor of causing AF.
ObjectTo evaluate the feasibility of measuring the descending aortic blood flow using transesophageal ultrasound Doppler under cardiopulmonary bypass (CPB). MethodWe retrospectively analyzed the clinical data of 10 adult patients accepted elective cardiac surgery under CPB in March 2014 year. There were 4 males and 6 females with a mean age of 44.5±12.3 years ranging from 24.5-64.0 years. The descending aorta diameter and velocity time integral (VTI) of blood flow of middle esophageal and lower esophageal of these patients were detected by transesophageal echocardiography (TEE) under CPB. We took the formula of classic ultrasound texting the blood flow to calculate the descending aorta blood flow (DABF). At the same time, we recorded the data of CPB and index of hemodynamics. Compared with the flow of CPB pump, we analyzed the correlation between pump flow and the raliability of DABF texting value under CPB. ResultsTwo patients quit the trail for blurred imaging. The quality of blood flow spectrum images aquirded from the middle esophageal were inferior to those from the lower esophageal (P < 0.01) in the 10 patients. Among the patients 90% of DABF from the middle esophageal and 50% of DABF from the lower esophageal were more than pump flow. however, the texting value had an excellence correlation to PF (r=0.795, r=0.825). ConclusionThe classical TEE technique can not obtain accurate blood flow during CPB.
ObjectiveTo explore the predictive value of systolic pulmonary artery pressure (SPAP) on autonomic nerve excitation in patients with valvular disease, so as to provide reference for the formulation of clinical intervention plans. Methods The clinical data of patients with valvular disease who received surgical treatment in the General Hospital of Northern Theater Command from August 28, 2020 to February 3, 2021 were prospectively collected. According to the standard deviation of normal-to-normal R-R intervals (SDNN) of the heart rate variability (HRV) of the long-range dynamic electrocardiogram (ECG) 7 days before the operation, the patients were divided into three groups: a sympathetic dominant (SE) group (SDNN≤50 ms), a balance group (50 ms<SDNN<100 ms) and a parasympathetic dominant (PSE) group (SDNN≥100 ms). The correlation between the changes of echocardiographic indexes and autonomic nerve excitation among the groups and the predictive values were analyzed. Results A total of 186 patients were enrolled, including 108 males and 78 females aged 55.92±11.99 years. There were 26 patients in the SE group, 104 patients in the balance group, and 56 patients in the PSE group. The left anteroposterior diameter (LAD), left ventricular end diastolic inner diameter, ratio of peak E to peak A of mitral valve (Em/Am), left ventricular end diastolic volume, left ventricular end systolic volume and SPAP in the SE group were higher than those in the balance group (P<0.05), while peak A of tricuspid valve (At) and left ventricular ejection fraction (LVEF) were lower than those in the balance group (P<0.05). The LAD and Em/Am in the balance group were significantly higher than those in the PSE group (P<0.05). Multivariate analysis showed that patients in the SE group had lower At (right atrial systolic function declines), lower LVEF and higher SPAP than those in the balance group (P=0.04, 0.04 and 0.00). When HRV increased and parasympathetic nerve was excited in patients with valvular disease, Em/Am decreased (left atrial function and/or left ventricular diastolic function declined) with a normal LAD. Pearson analysis showed that there was a linear negative correlation between SPAP and SDNN, with a coefficient of −0.348, indicating that the higher SPAP, the lower HRV and the more excited sympathetic nerve. Receiver operating characteristic curve showed that when SPAP≥45.50 mm Hg (1 mm Hg=0.133 kPa), the sensitivity and specificity of sympathetic excitation in patients with valvular disease were 84.60% and 63.70%, respectively. ConclusionParasympathetic excitation is an early manifestation of the disease, often accompanied by decreased left atrial function and/or left ventricular diastolic function. Sympathetic nerve excitation can be accompanied by the increase of SPAP and the decrease of left ventricular and right atrial systolic function. SPAP has a unique predictive value for the prediction of autonomic nerve excitation in patients with valvular disease.
Transcatheter aortic valve replacement (TAVR) has entered a new and critical stage after nearly 20 years of rapid development in China. There are various types of TAVR valves with different advantages. TAVR can be performed through various approaches such as transfemoral artery, transapical, trans-carotid artery, or trans-ascending aorta. The first two are more common. Echocardiography plays an important role in the perioperative period of TAVR. Compared to transfemoral approach, transapical TAVR has different key points in perioperative echocardiography which is lack of unified and accurate standards. This standard is specially formulated to focus on the key points of echocardiography in preoperative screening, intraoperative monitoring and postoperative follow-up in order to promote the safe and effective application of transapical TAVR in the clinic.
ObjectiveTo explore the safety and efficacy of transesophageal echocardiography (TEE)-guided percutaneous intervention for patent ductus arteriosus (PDA) in obese teenagers.MethodsFrom January 2018 to June 2019, 21 obese teenagers with PDA treated with femoral artery occlusion guided by TEE in the Department of Cardiac Surgery, Dalian Children's Hospital of Dalian Medical University were included in this study, including 13 males and 8 females aged 12.8-17.3 (15.1±1.7) years, with an average weight of 51.0-89.0 (73.4±10.1) kg. The operative effect was evaluated. ResultsAll patients successfully received the surgery, and none was changed to radiation-guided or thoracotomy ligation. The average operating time was 23.9±6.8 min, the average postoperative hospitalization time was 3.8±0.6 d. No peripheral vascular injury, intracardiac infection or pericardial effusion occurred. The mean follow-up time was 19.5±4.9 months, and the results of all reexaminations were good.ConclusionFor some PDA children with obesity, emphysema or thoracic malformation, it is difficult to block PDA by transthoracic ultrasound-guided percutaneous intervention, and TEE can avoid the interference of chest wall and lung qi, or other factors. It is an effective supplementary guidance method worthy of promotion.
ObjectiveTo investigate the effectiveness and safety of esophageal ultrasound-guided percutaneous femoral artery closure of ventricular septal defect (VSD).MethodsThe clinical data of 24 patients with congenital VSD in our hospital from March 2017 to December 2019 were retrospectively analyzed, including 6 males and 18 females, with a median age of 12 (3-42) years, weight of 32 (12-91) kg, and VSD diameter of 4 (3-7) mm. There were 3 patients with VSD combined with atrial septal defect.ResultsTwenty-four patients successfully underwent interventional closure of percutaneous femoral artery under esophageal ultrasound guidance, and the position and shape of the occluders were good. The operation time was 45 (39-54) min, and the waist size of the occluders was 7 (5-12) mm. Among the patients, 14 patients used symmetric ventricular occlusion devices, 8 patients used asymmetric ventricular occlusion devices, and 2 patients used ventricular occlusion muscle occluders. Small amount of residual shunt occurred in 2 patients after the operation and it disappeared 3 months after the operation. One patient with right bundle branch block, which disappeared after 1 week of observation. There were no complications such as occluder closure, pericardial effusion or valve regurgitation during the perioperative period. During the follow-up period [3-18 (9.25±5.04) months], no serious complication occurred.ConclusionTransesophageal ultrasound-guided transfemoral artery occlusion for VSD is simple and safe, and it avoids the damage of radiation and contrast medium. It has advantages over traditional percutaneous interventional occlusion therapy.