Objective To study the effect of anterior plate fixation on the treatment of middle and lower thirds fractures of humerus and the possibility of operating without injuring the radial nerve. Methods Forty-nine patients with the middle and lower thirds fractures of the humerus were treated with anterior plate fixation from March 1998 to December 2002. Of the 49 patients, 27 were with new fractures, 12 with old fractures, and 10 with nonunion fractures. According to AO classification, of the 49 patients, there were 19 type A, 14 type B1, 9 type B2, 5 type B3, 2 type C1. Thirty-seven patients had closed fractures and 12 had open fractures. Of the 12 patients, 8 were type Gustilo Ⅰ, 4 were type Gustilo Ⅱ. Four out of the 49 patients were associated with radial nerve palsy. All patients were treatedwith anterior plate fixation through the anterior approach to the humerus. The radial nerves injured were explored. Results Of the 49 patients, 48 were followed up 6 to 48 months(28.7 months on average). All fractures were healed within 3 to 9 months(4.7 months on average). Fixed plates of 37 patients out of the 49 were removed. No iatrogenic radial nerve injury occurred in the82 times of the operations among the 49 patients. Conclusion The treatment of middle and lower thirds fractures of humerus by anterior platefixation through the anterior approach to the humerus does not interfere with the fracture healing and can prevent the iatrogenic radial nerve injury.
Objective To investigate an effect of the minimally-invasive locking compression plate (LCP) under the anterior humeral approach to treat the complex humeral shaft fracture. MethodsEleven patients (6 males, 5 females; age, 3266 years) with a humeral shaft fracture were treated with the minimally-invasive LCP under the modified anterior humeral approach from March 2005 to February 2006. Five of the patients were injured in a traffic accident and the remaining 6 were wounded in a fall. All the patients had an unstable fracture. The multiple segment fracture was found in 2 patients, the obligue line fracture in 1 patient, and the long segment comminuted fracture in 8 patients, of whom the radial nerve injury was found in 1 patient, who had an emergency treatment by the loosening of the radial nerve and the internally fixing with LCP. As for the fracture site, the middle and/or the upper-part fracture of the humerus was found in6 patients, and the middle and/or lower-part fracture of the humerus was foundin 5 patients. The patients underwent the operation in the period from 48 hours to 4 days after the injuries. Results All the patients had a complete healing of their fractures 2-4 months after operation. One patient underwent the loosening of the radial nerve and the internally-fixing with LCP, and his function recovered 3 days after operation.The follow-up for 6-12 months revealed that all the patients’ function recovered. According to the Neer Scoring System for the shoulder function evaluation, 7 patients had an excellent result, 3 had a good result, and 1 had a fair result. According to the HSS Scoring System, 9 patients had an excellent result and 2 had a good result. Conclusion The minimally-invasive locking compression plate under the anterior humeral approach to treat the complex humeral shaft fracture is an effective and safe method of treating the complex humeral shaft fracture.
To explore the possibil ity of treating mid-distal humeral shaft fractures associated with radial nerve palsies with minimal invasive plating osteosynthesis (MIPO) techniques. Methods From April 2003 to October 2006, 10 patients with mid-distal humeral shaft fractures associated with radial nerve palsies were treated. All patients were male, aged 19-58 years. According to AO/ASIF classification, there were 4 cases of B1 type, 2 cases of B3 type, 1 case of A2 type, 1 caseof B2 type, 1 case of C3 type and 1 case of A3 type. A straight 4.5 mm dynamic compression plate was placed on the anterior aspect of humerus through two small incisions located on the anterior side of proximal and distal part of the arm. The radial nerve exploration was performed through a lateral small incision made on the fracture site. The fractures were then reduced by manual manipulation and the plate was fixated to the main fragments with 3 screws in each end of the plate. The postoperative compl ications, the bone heal ing time, and the recovery time of the radial nerve functions were recorded. The functions of the affected shoulder and elbow were assessed with UCLA and Mayo elbow performance score system respectively. Results All incision healed by first intention. Ten patients were followed up 9-36 months with an average of 15.7 months. The X-ray films showed that the union of fractures was achieved 12-16 weeks (13.6 weeks on average). The function of the radial nerves recovered completely 12-36 weeks (17.8 weeks on average) in 9 patients. The abductions of the affected shoulder were 150-170° (165° on average). The ROM of the elbows were 130-140° (135.5° on average). According to the UCLA shoulder scoring system, 9 patients achieved the excellent result and 1 patient achieved the good result. All the patients had the excellent results according to Mayo elbow performance score system. Conclusion The mid-distal humeral shaft fractures associated with radial nervepalsies can be treated with MIPO technique and the good results can be obtained.
Objective To investigate the cl inical effect of minimally invasive internal fixation percutaneous plate osteosynthesis (MIPPO) assisted by arthroscopy on tibial plateau fractures. Methods From September 2005 to December 2007, 29 patients with tibial plateau fracture underwent arthroscopy-assisted MIPPO, including 18 males and 11 females aged18-59 years old (average 34.7 years old). There were 8 cases of type II, 10 of type III, 5 of type IV, 3 of type V, and 3 of type VI according to Schatzker classification system. The fracture was combined with meniscus injury in 13 cases, anterior cruciate l igament injury in 4 cases, and medial collateral l igament injury in 3 cases. The time from injury to operation was 2-10 days. Firstly, the combined injury was treated under arthroscopy. Then, reduction of tibial plateau fractures was performed, bone grafting was conducted in the area of bone defect, and internal fixation using strut plates was performed after establ ishing subcutaneous tunnel via minimally invasion. Early rehabil itation activities were carried out for each patient 1 day after operation. Results No early compl ications such as poor heal ing of incisions, infections, and osteofascial compartment syndrome occurred. Over the follow-up period of 12-39 months (average 24 months), there was no failure of internal fixation, traumatic knee osteoarthritis, and inversion and eversion of the knee. The fractures healed within 3-4.5 months (average 3.5 months). The cl inical effect was excellent in 23 cases, good in 4 cases, and fair in 2 cases according to Lysholm knee rating system, and the excellent and good rate was 93.1%. Conclusion Arthroscopy-assisted MIPPO is a safe and effective way of managing tibial plateau fractures due to its features of minimal invasion, earl ier recovery, fewer compl ications, and simultaneous treatment of associated intra-articular injuries.
Objective To compare the differences between volar and dorsal plate positions in the treatment of unstable fracture of distal radius. Methods From June 2000 to December 2006, 61 cases with fracture of distal radius weretreated, 27 males and 34 females aged 22-70 years (55.5 years on average), among which 18 cases were caused by traffic accidents and 43 cases falls. All cases were fresh closed fractures. All patients had AP and lateral X-ray films of the wrist preoperatively and 30 cases experienced CT scan. According to AO, there were 25 cases for B1, 18 for B2, 7 for B3, 7 for C1, and 4 for C2. All the cases were randomized into 2 groups: the wrist palmar group (group A, n=34) and dorsal group (group B, n=27), to perform volar and dorsal plate fixation, respectively. As to the measurement of fortune for the preoperative ruler and incl ination angle, group A were (—45.0 ± 53.0)º and (8.6 ± 3.1)º, respectively, and group B were (—40.0 ± 30.0)º and (7.3 ± 5.6)º, respectively. Preoperative radial shortened (12.0 ± 5.3) mm in group A, and (10.3 ± 4.2) mm in group B. Joint surface level was (4.3 ± 2.2) mm in group A, and (4.1 ± 3.3) mm in group B. Results All of the 61 cases were followed up for 6-27 months (16 months on verage). All the fractures were healed, the time to heal ing in group A was (8.2 ± 1.6) weeks, and in group B was (8.1 ± 1.2) weeks, and the difference was not significant (P gt; 0.05). As for the wrist function by Cartland-Werley scoring at the 8th week after operation, 7 cases were excellent, 10 good, and 17 poor in group A with the choiceness rate of 50.0%, while 7 cases were excellent, 11 good and 9 poor in group B with the choiceness rate of 66.7%. There was significant difference between the two groups (P lt; 0.01). And at the 24th week after operation, 21 cases were excellent, 9 good, and 4 poor in group A with the choiceness rate of 88.2%, while 18 cases were excellent, 5 good, and 4 poor in group B with the choiceness rate of 85.2%. There was no significant difference between the two groups (P gt; 0.05). As for radiological assessment by Sarmiento, device and palm incl ination angles in group A were (9.5 ± 3.1)º and (18.0 ± 8.2)º, respectively, and in group B were (11.0 ± 4.7) º and (16.0 ± 7.6)º, respectively. No radial shortening was found either in group A or in group B, and joint surface level in both groups were less than 1 mm. There was no significant difference between group A and group B in terms of all indicators postoperatively (P gt; 0.05), but there was significant difference when compared with preoperation (P lt; 0.001). With regard to comparison of postoperative compl ications between the two groups, there was no significant difference (P gt; 0.05) in early postoperative compl ications, but there was in long-term compl ications (P lt; 0.01). Conclusion The volar and dorsal plate positions may offer effective stabil ity for unstable distal radial fracture and early functional exercise. The volar plate position may influence the pronation function of the wris joint in the short run, while the dorsal plate position may cause more compl ications in the long run.
Objective To compare the effectiveness of two minimally invasive methods: minimally invasive plating osteosynthesis (MIPO) and expandable intramedullary nail ing technique in treatment of middle third humeral shaft fractures. Methods The cl inical data were retrospectively analyzed and compared from 33 cases with middle third humeral shaft fractures between May 2004 and December 2008. All the patients were divided into 2 groups: 14 patients were treated with MIPOtechnique (group A) and 19 with expandable intramedullary nail ing technique (group B). In group A, there were 10 males and 4 females with an average age of 35 years (range, 21-51 years). The disease cause was traffic accident in 5 cases, tumbl ing in 6 cases, machine related trauma in 2 cases, crushed by a heavy object in 1 case. Six fractures were classified as AO type A, 6 as type B, and 2 as type C. The time from injury to operation was 3 to 11 days with an average of 5.9 days. In group B, there were 12 males and 7 females with an average age of 40 years (range, 19-68 years). The disease cause was traffic accident in 7 cases, tumbl ing in 8 cases, fall ing from height in 3 cases, crush injury in 1 case. Ten fractures were classified as AO type A, 8 as type B, and 1 as type C. The time from injury to operation was 2 to 6 days with an average of 4.2 days. There was no significant difference in general data between 2 groups (P gt; 0.05). Results The operation time was (104.6 ± 25.8) minutes in group A and (85.0 ± 35.7) minutes in group B, showing no significant difference (P gt; 0.05). Incision healed by first intention without iatrogenic radial nerve palsy in 2 groups. The patientswere followed up 21.4 months on average (range, 12-37 months) in group A and 20.5 months on average (range, 22-35 months) in group B. The X-ray films showed bony heal ing in all patients. The fracture union time was (16.4 ± 6.1) weeks in group A and (15.0 ± 2.5) weeks in group B, showing no significant difference (P gt; 0.05). The University of Cal ifornia Los Angeles (UCLA) End- Result scores were 34.1 ± 1.1 in group A and 31.8 ± 2.6 in group B and the Mayo Elbow Performance scores were 100 in group A and 97.6 ± 3.9 in group B; all showing significant differences (P lt; 0.05). Conclusion Good cl inical outcomes could be obtained when middle third humeral shaft fractures are treated by either MIPO or expandable intramedullary nail ing techniques. However, MIPO technique could offer better shoulder and elbow functional results.
ObjectiveTo systematically review the efficacy of percutaneous cannulated screw (PCS) versus plate fixation (PF) in the treatment of ankle fractures. MethodsThe Cochrane Library (Issue 5, 2014), PubMed, EMbase, CBM, CNKI, VIP and WanFang Data were searched up to May 28th 2014, for studies concerning the efficacy of percutaneous cannulated screw versus plate fixation for ankle fractures. Two reviewers independently screened literature according to the inclusion and exclusion criteria, extracted data and assessed the methodological quality of included studies. Then, meta-analysis was performed by using RevMan 5.1 software. Result A total of 10 studies (3 RCTs and 7 CCTs) involving 627 patients were included. The results of meta-analysis showed that:compared with the PF group, the PCS group was superior in time of the operation (RCT:MD=-6.78, 95%CI -11.95 to -1.60, P=0.01; CCT:MD=-9.76, 95%CI -13.68 to -5.84, P<0.000 01), blood loss during the operation (RCT:MD=-36.14, 95%CI -40.02 to -32.17, P<0.000 01; CCT:MD=-34.80, 95%CI -37.78 to -31.81, P<0.000 01) and the time of the fracture healing (RCT:MD=-1.16, 95%CI -1.51 to -0.81, P<0.000 01; CCT:MD=-1.55, 95%CI -2.97 to -0.13, P=0.03); However, there were no statistical differences between the two groups in complication rate (CCT:OR=0.48, 95%CI 0.08 to 2.81, P=0.41), AOFAS score excellent rate (RCT:OR=2.11, 95%CI 0.81 to 5.49, P=0.12; CCT:OR=1.58, 95%CI 0.75 to 3.30, P=0.23), and postoperative malleolus pain rate (CCT:OR=0.68, 95%CI 0.00 to 148.82, P=0.89). ConclusionCurrent evidence shows that PCS is superior to PF in shorting time of the operation, reducing blood loss during the operation, and shorting time of the fracture healing. However, the complication rate, AOFAS score excellent rate, and postoperative malleolus pain rate are similar for each operation. Due to the quality limitation of the CCTs, the conclusion are needed to be verified by more high quality RCTs in future.
ObjectiveTo investigate the short-term effectiveness of minimally invasive percutaneous plate osteosynthesis (MIPPO) in treatment of anterior pelvic ring fractures. MethodsBetween January 2012 and October 2013, 16 patients with anterior pelvic ring fractures were treated with MIPPO. There were 10 males and 6 females at the age of 20-63 years (mean, 41 years). The causes of injury were traffic accident in 9 cases and falling from height in 7 cases. The duration of injury to admission was 2 hours to 5 days (mean, 1 day). According to Tile classification, 8 cases were rated as type B2, 4 cases as type B3, 2 cases as type C1, and 2 cases as type C2. Of them, 2 cases had iliac wing fracture, and 4 cases had pelvic posterior ring fracture. The time from admission to operation was 3-12 days (mean, 6 days). ResultsThe bleeding volume was 60-120 mL (mean, 70 mL). All wounds healed by first intention. No postoperative complication of deep venous thrombosis or long-term continuous pain occurred. All cases were followed up 5-27 months (mean, 11.5 months). No clinical manifestation of lateral femoral cutaneous nerve injury or spermatic cord injury was found, and cremasteric reflex existed in males. All cases obtained bony union, and the healing time was 12-16 weeks (mean, 13 weeks). During the follow-up period, no loss of fracture reduction and no internal fixation loosening or broken were observed. According to Matta radiological evaluation criterion, 16 cases had anatomical reduction, and 3 cases had satisfactory reduction; according to Majeed scoring system of pelvic fracture, the results were excellent in 12 cases and good in 4 cases. ConclusionMIPPO for treatment of anterior pelvic ring fractures has the advantages of less intraoperative blood loss, few soft tissue complications, and low infection rate, and can get satisfactory short-term effectiveness.
Objective To investigate the effectiveness of minimally invasive plate fixation in treatment of unstable pelvic fractures. Methods Between May 2006 and December 2009, 21 patients with unstable pelvic fractures were treated. There were 13 males and 8 females with an average age of 39 years (range, 21-66 years). The causes of injury included traffic accident in 9 cases, falling from height in 6 cases, and heavy pound injury in 6 cases. The time from injury to hospitalization was 1 to 4 hours with an average of 2.8 hours. According to Tile’s classification, there were 12 cases of type B and 9 cases of type C. After admission, bone traction and exo fixation were performed, and minimally invasive plate fixation was given at 5-24 days after injury. Results All incisions healed by first intention, and no complications of nerve and vessel injuries occurred. According to the reduction criteria of Matta radiography, anatomic reduction was achieved in 16 cases, satisfactory reduction in 4 cases, and fair reduction in 1 case. All patients were followed up 12 months. The X-ray films showed all fractures healed at 2-4 months (mean, 2.6 months). According to Majeed clinical evaluation, the results were excellent in 12 cases, good in 7 cases, and fair in 2 cases. Conclusion Minimally invasive plate fixation can provide effective fixation, reconstruct pelvic ring, and reduce perioperative complications in the treatment of unstable pelvic fractures.