Objective To compare the cl inical results of two plating osteosynthesis techniques, open reduction and plating ostosynthesis (ORPO) and minimal invasive plating osteosynthesis (MIPO), in surgical treatment of mid-distal humeralshaft fractures. Methods From March 2004 to October 2006, 40 cases of closed unilateral mid-distal humeral shaft fractures were surgically treated with MIPO or ORPO. In the MIPO treated group (n=19), there were 14 males and 5 females, with a mean age of 39.05 years. Fractures involved in middle humeral shaft in 10 cases and distal fragment in 9 cases. According to OTA classification, there were 3 cases of type A, 13 cases of type B and 3 cases of type C. Four cases compl icated by radial nerve palsies. In the ORPO treated group (n=21), there were 13 males and 8 females with a mean age of 39.05 years, including 14 cases of type A and 7 cases of type B fractures according to OTA classification. The fractures involved in middle humeral shaft in 13 cases and distal fragment in 8 cases. Five cases compl icated by radial nerve palsies. The time from injury to operation in both groups were 2 to 14 days. For patients in the MIPO group, fractures were closely reduced and fixated with an anterior placed plate inserted through two small incisions made at the anterior side of arm, away from fracture sites. The radial nerves were not exposed. For patients in the ORPO group, fractures were exposed, reduced, and fixated with an anterolateral or a posterior positioned plate after careful dissection and protection of radial nerve through an anterolateral or a posterior approach. The operation time, the occurrence of iatrogenic radial nerve palsy and the bone heal ing time were recorded. The functions of the affected shouldersand elbows were evaluated with UCLA end-result score and Mayo elbow perform index (MEPI), respectively. Results All the wounds in both groups healed primarily. There was no iatrogenic radial nerve palsies in the MIPO group after surgery; however, 5 cases of transient iatrogenic radial nerve palsies were identified in the ORPO group after surgery, and the function of radial nerve recovered in these cases at the last follow-up. Eighteen cases were followed up 14-44 months (mean 25.44 months) in MIPO group, and 19 cases were followed up 13-48 months (mean 32.11 months) in ORPO group. The mean bone heal ing time was 17.06 (12-32) weeks in MIPO group and 16.11 (8-58) weeks in ORPO group, showing no significant difference between two groups (P gt; 0.05). There was no nonunion and hardware failure in both groups. The mean forward flexion of the shoulder was 166.94° (150-170°) in MIPO group and 164.74° (130-170°) in ORPO group. The mean UCLA shoulder score was 34.78 (33-35) points in MIPO group and 34.42 (30-35) points in ORPO group. The mean range of motion of the elbow in MIPO and ORPO groups was 133.33° (120-140°) and 136.7° (120-140°), respectively. The MEPI in these two groups was 99.44 (90-100) and 99.74 (95-100) points, respectively. There was no statistically significant difference between two groups in all indexes mentioned above. Conclusion The good results could be obtained when ORPO and MIPO technique are appl ied to treat mid-distal humeral shaft fractures. MIPO technique has advantages to not expose the radial nerve and to decrease the occurrence of iatrogenic radial nerve palsies.
Objective To discuss the relationship between recovery of anatomical integrity and functional outcome in elderly patients with distal radius fractures by comparing the effects of open reduction and closed reduction. Methods The cl inical data were retrospectively analyzed from 78 elderly patients with distal radius fractures treating with nonoperation andoperation from February 2005 to March 2009. Thirty-seven patients underwent closed reduction and spl intlet fixation or cast appl ication (non-operation group), and forty-one patients underwent open reduction and internal fixation (operation group). In non-operation group, there were 15 males and 22 females with an average age of 73 years (60-83 years). According to the AO classification system for fracture, there were 8 cases of type A2, 7 cases of type A3, 7 cases of type B1, 4 cases of type B2, 2 cases of type B3, 4 cases of type C1, 2 cases of type C2, and 3 cases of type C3. The time from injury to admission was between 30 minutes and 3 days with a mean time of 1 day. In operation group, there were 18 males and 23 females with an average age of 71 years (62-80 years). According to the AO classification system for fracture, there were 5 cases of type A2, 7 cases of type A3, 7 cases of type B1, 6 cases of type B2, 3 cases of type B3, 4 cases of type C1, 5 cases of type C2, and 4 cases of type C3. The time from injury to admission was between 30 minutes and 7 days with a mean time of 1 day. There were no significant differences (P gt; 0.05) in sex, age, disease course and fracture classification between two groups. Results All incisions obtained heal ing by first intention after operation in operation group. All patients were followed up for 9-36 months (20 months on average). Fracture heal ing was achieved within 8 to 15 weeks, with an average of 11 weeks. There were no significant differences (P gt; 0.05) in fracture heal ing time between non-operation group [(10.8 ± 2.0) weeks] and operation group [(11.7 ± 2.5) weeks]. At last follow-up, thepalmar tilt angle was (5.6 ± 2.0)° and (8.6 ± 3.0)°, the radial incl ination angle was (19.1 ± 4.9)° and (21.8 ± 2.0)°, and the radial length was (8.3 ± 1.3) mm and (10.4 ± 1.4) mm in non-operation group and operation group, respectively; showing significant differences (P lt; 0.05) between two groups. According to the Gartland-Werley score, the results were excellent in 9 cases, good in 21 cases, fair in 5 cases, and poor in 2 cases in non-operation group, the excellent and good rate was 81.1%; in operation group, the results were excellent in 13 cases, good in 25 cases, fair in 2 cases, and poor in 1 case, the excellent and good rate was 92.7%, showing no significant difference (P gt; 0.05) between two groups. There were no significant differences (P gt; 0.05) in flexion and extension activity of wrist, radioulnar partial activity, pronation-supination activity, grip and pinch strength between two groups. Conclusion Open reduction and closed reduction can achieve satisfactory functional outcomes, but closed reduction was inferior to open reduction in anatomic reduction for treating distal radius fractures in elderly patients.
ObjectiveTo evaluate the feasibility and effectiveness of percutaneous screwdriver rod-assisted closed reduction in the treatment of valgus-impacted femoral neck fractures. MethodsBetween January 2021 and May 2022, 12 patients with the valgus-impacted femoral neck fractures were treated with percutaneous screwdriver rod-assisted closed reduction and femoral neck system (FNS) internal fixation. There were 6 males and 6 females with a median age of 52.5 years (range, 21-63 years). The fractures were caused by traffic accident in 2 cases, falling in 9 cases, and falling from height place in 1 case. All were unilateral closed femoral neck fractures, including 7 on the left side and 5 on the right side. The time from injury to operation was 1-11 days, with an average of 5.5 days. The fracture healing time and postoperative complications were recorded. The quality of fracture reduction was evaluated by Garden index. At last follow-up, Harris score was used to evaluate the hip joint function, also the shortening of femoral neck was measured. ResultsAll the operations were successfully completed. After operation, the incision fat liquefaction occurred in 1 case, which healed after enhanced dressing change, and the other patients’ incisions healed by first intention. All patients were followed up 6-18 months, with an average of 11.7 months. The X-ray film reexamination showed that the quality of fracture reduction was grade Ⅰ in 10 cases and grade Ⅱ in 2 cases according to the Garden index. All fractures reached bony union, and the healing time was 3-6 months, with an average of 4.8 months. At last follow-up, the femoral neck was shortened by 1-4 mm, with an average of 2.1 mm. No internal fixation failure or osteonecrosis of the femoral head occurred during follow-up. At last follow-up, the hip Harris score was 85-96, with an average of 92.4; 10 cases were rated as excellent and 2 were good. Conclusion The percutaneous screwdriver rod-assisted closed reduction can effectively reduce the valgus-impacted femoral neck fracture. It has the advantages of simple operation, effective, and less impact on blood supply.
Objective To investigate the effectiveness of medial and lateral column periosteal hinge reconstruction using Kirschner wire in the closed reduction of multi-directional unstable humeral supracondylar fractures in children. Methods A clinical data of 43 children with multi-direction unstable humeral supracondylar fractures, who met the selection criteria and were admitted between August 2020 and August 2022, was retrospectively analyzed. Twenty-one cases of fractures were treated wuth closed reduction after medial and lateral column periosteal hinge reconstruction using Kirschner wire and percutaneous Kirschner wires fixation (study group), while 22 cases of fractures were treated by traditional closed reduction technique and percutaneous Kirschner wire fixation (control group). There was no significant difference in gender, age, cause of injury, fracture side, and interval from injury to operation between the two groups (P>0.05). The operation time, intraoperative fluoroscopy times, the number of children who were changed to open reduction after closed reduction failure, fracture healing time, complications within 2 months after operation, and the Flynn score of elbow joint function at last follow-up were compared between the two groups. ResultsAll the fractures in the study group were successfully closed reduction, and 4 cases in the control group were changed to open reduction and completed the operation, the difference between the two groups was significant (P=0.040). The operation time and intraoperative fluoroscopy times of the study group were significantly less than those of the control group (P<0.05). All children in both groups were followed up 6-18 months with an average of 9.0 months in the study group and 9.8 months in the control group. Imaging review showed that the fractures of both groups healed, and the difference in the healing time between the two groups was not significant (P=0.373). According to Flynn score at last follow-up, the excellent and good rate of elbow joint function was 95.2% (20/21) in the study group and 86.4% (19/22) in the control group, with no significant difference (P=0.317). There was no complication such as infection or irritation at the end of Kirchner wire within 2 months after operation. Conclusion For children with multi-directional unstable humeral supracondylar fractures, the use of Kirschner wires to reconstruct the medial and lateral column periosteal hinge to assist in closed reduction has the advantages of shortening operation time, reducing intraoperative fluoroscopy times, and effectively reducing the incidence of open reduction, and can achieve similar postoperative elbow joint function when compared with traditional closed reduction technique.
ObjectiveTo explore the effectiveness of Taylor spatial frame (TSF) in the treatment of tibiofibular fractures and computer-assisted closed reduction.MethodsThe clinical data of 30 cases of tibiofibular fractures with soft tissue injury treated with TSF between January 2015 and September 2017 was retrospectively analyzed. According to different reduction methods, the patients were divided into control group (15 cases, open reduction in TSF external fixation) and trial group (15 cases, closed reduction in 1-3 days after TSF external fixation). There was no significant difference in the general data such as gender, age, affected side, cause of injury, AO classification of fracture, time from injury to operation between the two groups (P>0.05). The operation time, intraoperative blood loss, fracture healing time, and removal time of external fixator were recorded and compared between the two groups. At 3 months after removal of external fixator, the limb function was evaluated according to Johner-Wruhs criteria for evaluating the final effect of tibial shaft fracture treatment.ResultsBoth groups were followed up 9-16 months, with an average of 14 months. The operation time, intraoperative blood loss, fracture healing time, and removal time of external fixator in the trial group were significantly shorter than those in the control group (P<0.05). There were 2 cases of superficial infection of the external fixation (1 case in each group), 1 case of incision infection (control group), 1 case of delayed fracture healing (control group), 2 cases of traumatic arthritis (1 case in each group); no significant difference was found in the incidence of complications between the two groups (χ2=0.370, P=0.543). The wounds of soft tissue defect healed by the first intension in both groups. At 3 months after removal of the external fixator, the limb function results in the trial group were excellent in 3 cases, good in 9 cases, fair in 2 cases, and poor in 1 case, and the excellent and good rate was 80.0%; in the control group, the results were excellent in 3 cases, good in 8 cases, fair in 3 cases, and poor in 1 case, and the excellent and good rate was 73.3%. There was no significant difference in incidence of complication between the two groups (χ2=0.917, P=0.821).ConclusionCompared with intraoperative open reduction, postoperative computer-aided closed reduction can shorten the operation time, reduce the intraoperative blood loss, reduce the risk of long-term operation, avoid to destroy the blood supply of fracture end, shorten the healing time of fracture and the wearing time of stent, and alleviate the pain of patients after TSF treatment of tibiofibular fracture.
ObjectiveTo compare the effectiveness of ultrasound-guided closed reduction and Kirschner wire fixation for different unstable humeral lateralcondylar fractures of children. Methods The clinical data of 94 children with unstable humeral lateralcondylar fractures admitted to three medical centers between January 2021 and October 2022 were retrospectively analyzed. The children were divided into three groups according to the Song classification and whether the elbow joint was dislocated or not, including 42 cases of Song 4 type (group A), 38 cases of Song 5 type (group B), and 14 cases of elbow joint dislocation (group C). There was no significant difference in gender, age, side, cause of injury, and time from injury to operation among the three groups (P>0.05). All children were treated with ultrasound-guided closed reduction and Kirschner wire fixation. The operation time and complications of the three groups were recorded and compared, and the failure of closed reduction was evaluated by ultrasound. X-ray examination was performed at last follow-up to measure the Baumann angle, condylar angle, carrying angle, and lateral osteophyte of the affected side; the extension, flexion, pronation, and supination range of motion of the affected elbow joint were measured; the function of the elbow joint was evaluated by Mayo score. ResultsThe operation time in group A was significantly longer than that in groups B and C (P<0.05). There were 7, 2, and 5 cases of closed reduction failure in groups A, B, and C, respectively, and there was no significant difference in the incidence of the closed reduction failure (P>0.05). All patients were followed up 6-28 months, with an average of 15.7 months. There was no significant difference in the follow-up time among the three groups (P>0.05). Complications: in group A, there were 2 cases of delayed union, 4 cases of needle tract infection, 1 case of trochlear necrosis, and 39 cases of lateral osteophyte; in group B, there was 1 case of malunion, 5 cases of needle tract infection, 1 case of redisplacement, and 26 cases of lateral osteophyte; in group C, there were 2 cases of needle tract infection and 10 cases of lateral osteophyte. There was no significant difference in the incidence of complications among the three groups (P>0.05). No cubitus varus or cubitus valgus deformity was found in all patients. At last follow-up, except that the condylar angle in group A was significantly greater than that in groups B and C (P<0.05), there was no significant difference in other imaging indicators, elbow range of motion, or Mayo score between groups (P>0.05). ConclusionThe Song type 4 of humeral lateralcondylar fracture treated with ultrasound-guided closed reduction and Kirschner wire fixation has a longer operation time, more postoperative complications, and is more prone to lateral osteophyte.
【Abstract】 Objective To discuss the techniques and advantages of closed reduction and intramedullary nail ing intreating femoral shaft fracture without cannulated femoral reamer. Methods From January 2006 to June 2007, 24 cases offemoral shaft fracture were treated with closed reduction and intramedullary nail ing. Among them, there were 14 males and 10 females, with the average age of 38.3 years (ranging from 18 years to 63 years), with 7 left legs and 17 right legs. The average course of the disease was 7.6 days (ranging from 3 days to 20 days). According to the AO typing, there were 5 cases of type A, 6 of type B, 7 of type C1, 2 of type C2 and 4 of type C3. Closed reduction was achieved with manipulation and reaming of femoral canal was instructed by fluoroscopy. Results The operation time lasted from 100 minutes to 170 minutes, with the average time of 128.3 minutes. One patient was given a transfusion of 400 mL, and others were not. Twenty cases were followed up with the average time of 13.1 months (ranging from 6 months to 24 months). A mild to large amount of bony callus was showed on X-ray films 6 to 12 weeks postoperatively. Walking without crutches began at the average week of 22.2 (ranging from 15 to 30) postoperatively. Range of motion of the knee was 0° to 145.5°. No infection or break of the internal fixator occurred. Myositis ossificans with pain and insufficient flexion of hip (120°) happened in 1 case and the pain disappeared after non-steroid anti-inflammatory drugs were taken. Nonsymptomatic myositis ossificans occurred in 2 cases and no treatment was needed. Conclusion Closed reductionand intramedullary nail ing can help to protect the blood supply of fracture fragments and provide central fixation. The operation process will be more compl icated if cannulated femoral reamer is not available.
Objective To explore the effectiveness of reduction robot combined with navigation robot-assisted minimally invasive treatment for Tile type B pelvic fractures. Methods Between January 2022 and February 2023, 10 patients with Tile type B pelvic fractures were admitted. There were 6 males and 4 females with an average age of 45.5 years (range, 30-71 years). The fractures were caused by traffic accident in 5 cases, bruising by heavy object in 3 cases, and falling from height in 2 cases. The interval between injury and operation ranged from 4-13 days (mean, 6.8 days). There were 2 cases of Tile type B1 fractures, 1 case of Tile type B2 fracture, and 7 cases of Tile type B3 fractures. After closed reduction under assistance of reduction robot, the anterior ring was fixed with percutaneous screws with or without internal fixator, and the posterior ring was fixed with sacroiliac joint screws under assistance of navigation robot. The time of fracture reduction assisted by the reduction robot was recorded and the quality of fracture reduction was evaluated according to the Matta scoring criteria. The operation time, intraoperative fluoroscopy frequency and time, intraoperative bleeding volume, and incidence of complications were also recorded. During follow-up, the X-ray film of pelvis was taken to review the fracture healing, and the Majeed score was used to evaluate hip joint function. Results The time of fracture reduction was 42-62 minutes (mean, 52.3 minutes). The quality of fracture reduction according to the Matta scoring criteria was rated as excellent in 4 cases, good in 5 cases, and poor in 1 case, with excellent and good rate of 90%. The operation time was 180-235 minutes (mean, 215.5 minutes). Intraoperative fluoroscopy was performed 18-66 times (mean, 31.8 times). Intraoperative fluoroscopy time was 16-59 seconds (mean, 28.6 seconds). The intraoperative bleeding volume was 50-200 mL (range, 110.0 mL). No significant vascular or nerve injury occurred during operation. All patients were followed up 13-18 months (mean, 16 months). X-ray films showed that all fractures healed with the healing time of 11-14 weeks (mean, 12.3 weeks). One case of ectopic ossification occurred during follow-up. At last follow-up, the Majeed score was 70-92 (mean, 72.7), and the hip joint function was rated as excellent in 2 cases and good in 8 cases, with the excellent and good rate of 100%. Conclusion The reduction robot combined with navigation robot-assisted minimally invasive treatment for Tile type B pelvic fractures has the characteristics of intelligence, high safety, convenient operation, and minimally invasive treatment, which can achieve reliable effectiveness.
Objective To investigate the short-term effectiveness of transverse antecubital incision in the treatment of failed closed reduction of Gartland type Ⅲ supracondylar humeral fractures (SHFs) in children. Methods Between July 2020 and April 2022, 20 children with Gartland type Ⅲ SHFs who failed in closed reduction were treated with internal and external condylar crossing Kirschner wire fixation through transverse antecubital incision. There were 9 boys and 11 girls with an average age of 3.1 years (range, 1.1-6.0 years). The causes of injuries were fall in 12 cases and fall from height in 8 cases. The time from admission to operation ranged from 7 to 18 hours, with an average of 12.4 hours. The healing of the incision and the occurrence of complications such as nerve injury and cubitus varus were observed after operation; the elbow flexion and extension range of motion after removing the gypsum, after removing the Kirschner wire, and at last follow-up were recorded and compared, as well as the elbow flexion and extension and forearm rotation range of motion at last follow-up between healthy and affected sides; the Baumann angle was measured on the X-ray film, and the fracture healing was observed. At last follow-up, the effectiveness was evaluated according to the Flynn elbow function evaluation criteria. ResultsAll incisions healed by first intention, and there was no skin necrosis, scar contracture, ulnar nerve injury, and cubitus varus. Postoperative pain occurred in the radial-dorsal thumb in 2 cases. The gypsum was removed and elbow flexion and extension exercises were started at 2-4 weeks (mean, 2.7 weeks) after operation, and the Kirschner wire was removed at 4-5 weeks (mean, 4.3 weeks). All the 20 patients were followed up 6-16 months, with an average of 12.4 months. The fracture healing time was 4-5 weeks, with an average of 4.5 weeks, and there was no complication such as delayed healing and myositis ossificans. The flexion and extension range of motion of the elbow joint gradually improved after operation, and there were significant differences between the time after removing the gypsum, after removing the Kirschner wire, and at last follow-up (P<0.017). There was no significant difference in the flexion and extension of the elbow joint and the forearm rotation range of motion between the healthy and affected sides at last follow-up (P>0.05). There was no significant difference in Baumann angle between the time of immediate after operation, after removing the Kirschner wire, and at last follow-up (P>0.05). According to Flynn elbow function evaluation standard, 16 cases were excellent and 4 cases were good, the excellent and good rate was 100%. Conclusion The treatment of Gartland type Ⅲ SHFs in children with failed closed reduction by internal and external condylar crossing Kirschner wire fixation through transverse antecubital incision has the advantages of complete soft tissue hinge behind the fracture for easy reduction and wire fixation, small incision, less complications, fast fracture healing, early functional recovery, reliable reduction and fixation, and can obtain satisfactory results.