Objective To observe the plastic changes of sensory nerve in terms of structure and function when targetorgan changed through making the rat model of nerve regeneration by anastomosing the proximal end of sensory nerve and the distal end of motor nerve. Methods Thirty adult SD rats (male or female), weighing 200-250 g, were randomized into three groups (n=10 per group). The left upper l imb of the each rat was used as the experimental side, while the right upper l imb as the control side. In group A, the medial antebrachial cutaneous nerve was cut 5 mm away from its origin and its proximal end was anastomozed end-to-end to the distal end of musculocutaneous nerve. In group B, the musculocutaneous nerve was cut 5 mm away from its nerve entry point and the proximal end of medial antebrachial cutaneous nerve were anastomozed end-to-end to the distal end of musculocutaneous nerve. In group C, medial antebrachial cutaneous nerve and musculocutaneous nerve were cut, without further anastomosis. Twenty-four weeks after operation, the general condition and the motion of the elbow joint of rats, the wet weight and muscle fiber cross-section area of the biceps brachii as well as the latent period and the ampl itude of the evoked potential were observed and the acetylchol inesterase (AchE) staining of nerve of proximal end of anastomosis was conducted. Results All the rats survived for 24 weeks with good general condition and without wound infection. The rats in groups A, B and C were lost the active flexion of left elbow joint after operation. The rats in groups A and B got recovered to some degree at 24 weeks. The behavioral evaluation showed that there were 7 l imbs in group A and 5 l imbs in group B scoredas 4-5 points, there was a significant difference when compared with group C (P lt; 0.05), but there was no significant difference between group A and group B (P gt; 0.05). Group A and group B were superior to group C in terms of the wet weight and the muscle fiber cross-section area of the biceps brachii (P lt; 0.05), but no significant difference between group A and group B was detected (P gt; 0.05). The evoked potential of the biceps brachii and motor nerve fibers in proximal end of anastomosis could be detected in both group A and group B. But there was no significant difference between group A and group B with respects of function recovery of elbow joint, the latent period and the ampl itude of the evoked potential of the biceps brachii and the quantity of motor nerve fiber in proximal end of anastomosis (P gt; 0.05). Conclusion The change of target organ leads to the sensory nerve plasticity structurally and functionally, which may provide a new approach for peripheral nerve repair.
Abstract: Objective To study the integration of transplanted cells and host cells by detection of the cellcell junction after transplantation of the myocardiumlike cell derived from the canine umbilical cord blood. Methods The mesenchymal stem cell(MSCs) was transfected by Laz-Z after harvest, culture, induced by 5-azacytidine(5-aza). Thirty-six adult hybrid dogs were randomly divided into cell transplantation group and control group. The canine of myocardium infarction was established. 107 MSCs were transplanted into dogs with acute myocardium infarction by coronary artery infusion and local injection in cell transplantation group and physiologic saline was used in the control group. The specimens were harvested and detected by immunofluorescence for 2, 4 and 8 weeks respectively. Results The umbilical cord blood MSCs were fusiform or spindleshaped. They presented clonal and knittinglike growth.The MSCs could differentiate into myocardium-like cell by the induction of 5-aza and express α-actin, desmin, connexin43.The transplanted cells could survive more than 8 weeks after transplantation. Cadherin and connexin 43 were found in the position of cellcell junction of transplanted cells group and between transplanted cells and host cells. Cadherin and connexin 43 were found in the hose cells of the control group. Conclusion The umbilical cord blood MSCs is able to differentiate into myocardiumlike cell in vitro and form cellcell junction in vivo to communicate with surrounding cells.
Objective To evaluate the safety and efficacy of biatrial Cox Maze Ⅳ cryoablation for concomitant atrial fibrillation (AF) during minimally invasive valve surgery. Methods A total of 47 patients (26 males, 21 females, age of 42-69 years) with mitral valve disease and long-standing persistent AF received minimally invasive biatrial Cox Maze Ⅳ cryoablation procedure combined with mitral valve surgery through right minithoracotomy from January 2014 to September 2015. The etiology of mitral valve disease was rheumatic (n=31) and degenerative (n=16). AF duration ranged from 2 to 11 years. Diameter of the left atrium ranged from 43 to 60 mm. Concomitant biatrial Cox Maze Ⅳ cryoablation procedure was performed through right lateral minithoracotomy. Results All 47 patients successfully underwent this minimally invasive concomitant biatrial Cox Maze Ⅳ cryoablation procedure and valve surgery. No patient needed conversion to sternotomy during the surgery. The mean cardiopulmonary bypass time, aortic cross-clamp time and cryoablation time was 95-146 (120.3±12.3) min, 82-115 (93.3±7.7) min and 32-48 (38.6±4.5) min, respectively. There was no death perioperatively. The average postoperative length of hospital stay was 5-16 (7.9±1.9) d. At discharge, 44 patients (44/47, 93.6%) maintained sinus rhythm. At a mean follow-up of 6-26 (14.4±5.4) months, sinus rhythm was maintained in 41 patients (41/47, 87.2%). Cumulative maintenance rate of normal sinus rhythm without AF recurrence at one year postoperatively was 86.3%±5.8%. Conclusion Biatrial Cox Maze Ⅳ cryoablation procedure is safe, feasible and effective for AF during concomitant minimally invasive valve surgery.
ObjectiveTo investigate influence of left atrial contraction on lone atrial fibrillation recurrence after minimally invasive radiofrequency ablation. MethodsClinical data of 57 patients with lone atrial fibrillation underwent minimally invasive radiofrequency ablation in Department of Cardiothoracic Surgery, Xinhua Hospital, Medical School of Shanghai Jiaotong University from September 2010 to December 2011 were retrospectively analyzed. According to the absence of mitral A velocity, patients were divided into Group A (absence of mitral A velocity, 20 patients with their age of 56.32±17.18 years, including 5 females) and Group B (mitral A velocity exists, 37 patients with their age of 60.33±11.22 years, including 17 females). Minimally invasive radiofrequency ablation via thoracoscope were performed in all patients. Preoperative and postoperative left atrial diameter (LAD), left ventricular ejection fraction (LVEF) and mitral A velocity, as well as clinical and follow-up data were recorded and compared. ResultsPreoperative clinical characters were not statistically different between two groups (P > 0.05). All the patients were followed up for 24.3±8.8 months (range, 12-26 months). Rate of postoperative atrial fibrillation recurrence in group A was significantly higher than that in group B (20.0% vs. 2.7%, P < 0.05). LAD and LVEF of 57 patients at 6 months after surgery were significantly higher than preoperative LAD and LVEF (P < 0.05), but there was no statistic difference between two groups (P > 0.05). ConclusionDamage of left atrial contraction was related to lone atrial fibrillation recurrence after minimally invasive radiofrequency ablation. Absence of mitral A velocity could be a crucial predictor of postoperative lone atrial fibrillation recurrence.
ObjectiveTo summarize the efficacy of clips and staplers for left atrial appendage in the thoracoscopic treatment of atrial fibrillation. Methods The clinical data of patients with atrial fibrillation treated in Xinhua Hospital from 2015 to 2016 were retrospectively analyzed. All patients received Mei's minimally invasive surgery for atrial fibrillation. Among them, patients were recruited in a clip group by clipping the left atrial appendage. The other patients were recruited in a stapler group to resect the left atrial appendage by stapler. Follow-up was conducted by outpatient clinic and telephone. Postoperative heart rhythm was recorded by the patient's symptoms, electrocardiogram and 24 h holter. Cranial magnetic resonance, cardiac CT and echocardiography were performed at least once during follow-up. Results There were 30 patients in the clip group, including 20 males and 10 females, with an average age of 65.7±7.1 years. There were 30 patients in the stapler group, including 20 males and 10 females with an average age of 66.8±5.4 years. All patients successfully received the procedure, with no conversion to thoracotomy or perioperative death. Sinus rhythm was maintained at discharge in 56 (93.3%) patients. Till June 2020, 59 patients were followed up for 42-66 (54.1±7.3) months and 1 patient in the clip group was lost. The residual length of the left atrial appendage was 3.9±1.8 mm in the clip group and 3.9±2.8 mm in the stapler group, and there was no statistical difference between the two groups (P=0.910). Kaplan-Meier curve indicated that there was no statistical difference in the maintenance of sinus rhythm between the two groups (P=0.757). During the follow-up period, all patients had no cerebrovascular adverse events such as stroke or embolism. Conclusion Clipping and resection of the left atrial appendage in thoracoscopic atrial fibrillation surgery are both safe and effective methods, which effectively prevent stroke. The atrial appendage clip makes the minimally invasive surgical intervention of the left atrial appendage safer and more convenient.
ObjectiveTo compare clinical outcomes between biatrial ablation and right atrial ablation in the surgical treatment of atrial fibrillation (AF)for adult patients with atrial septal defect (ASD). MethodsClinical data of 47 patients with ASD and AF who underwent surgical ASD repair and radiofrequency ablation from January 2007 to December 2012 were retrospectively analyzed. There were 20 male and 27 female patients with their age of 35-76 years. AF duration ranged from 3 months to 15 years. There were 18 patients with persistent AF and 29 patients with long-standing persistent AF. There were 10 patients with mild-to-moderate or more severe mitral regurgitation (MR), and 28 patients with mild-to-moderate or more severe tricuspid regurgitation (TR). According to different surgical strategies, all the 47 patients were divided into 2 groups. In right atrial ablation group, there were 19 patients who received ASD repair and right atrial ablation. In biatrial ablation group, there were 28 patients who received ASD repair and biatrial ablation. For patients with mild-to-moderate or more severe MR or TR, concomitant mitral or tricuspid valvuloplasty was performed. All the patients received 24-hour Holter monitoring at 3, 6 and 12 months after discharge, and were intermittently followed up thereafter. ResultsCardio-pulmonary bypass time, aortic cross-clamping time and postoperative hospital stay of biatrial ablation group were significantly longer than those of right atrial ablation group. But there was no statistical difference in postoperative morbidity or recovery between the 2 groups. After heart rebeating, there were 25 patients (89.3%)with sinus rhythm (SR)and 3 patients with junc-tional rhythm (JR), and none of the patients had AF in biatrial ablation group. There were 14 patients (73.7%)with SR, 2 patients with JR and 3 patients with AF in right atrial ablation group. At discharge, 28 patients (100%)in biatrial ablation group had SR, and in right atrial ablation group there were 15 patients (78.9%)with SR and 4 patients with AF relapse (P=0.045). All the patients were followed up for 3-75 months, and there was no death or residual ASD shunt during follow-up. Two patients had mild-to-moderate or more severe MR, and 4 patients had mild-to-moderate or more severe TR. Cumulative SR maintenance rate of biatrial ablation group (87.7%±6.7%)was significantly higher than that of right atrial ablation group (47.4%±11.5%, P=0.003)at 2 years after discharge. ConclusionFor adult patients with ASD and AF, biatrial ablation can produce better clinical outcomes than right atrial ablation without increasing surgical risks.
ObjectiveTo study the clinical results of Mini Maze procedure in atrial fibrillation patients with impaired left ventricular systolic function.MethodsFrom June 2010 to December 2017, 86 atrial fibrillation patients with impaired left ventricular systolic function received Mini Maze procedure including 54 males and 32 females, with an average age of 60.7±5.9 years. Among them, 12 were with paroxysmal, 27 were with persistent and 47 were with long-standing persistent atrial fibrillation. The mean atrial fibrillation duration was 6.5±4.8 years. CHA2DS2-VASc score was 2.2±1.1. The mean diameter of left atrium was 46.9±3.8 mm. The mean diameter of left ventricle was 51.7±4.6 mm. The preoperative ejection fraction was 42.2%±4.7%. All patients received Mini Maze procedure after general anesthesia. The ablation included 3 annular ablations and 3 linear ablations. The left atrial appendage was excised by Endo-Gia. Ablation of Marshall ligament and epicardial autonomic ganglions were made by an ablation pen.ResultsEighty-six patients successfully completed the procedure without transition to thoracotomy. There was no death during the perioperative period. Seventy-seven patients (89.5%) maintained sinus rhythm at discharge. Eighty patients were followed up for 27.2±12.1 months and 72 patients maintained sinus rhythm. The overall postoperative left ventricular ejection fraction was 47.1%±6.2%. The ejection fraction of the postoperative sinus rhythm group was 48.2%±5.8%, and the ejection fraction of the non-sinus group was 41.6%±5.8% (P<0.05). Multivariate regression analysis showed a left atrial diameter (HR=1.485, 95%CI 1.157-1.906, P<0.05) and an increase in ejection fraction over 10% (HR=18.800, 95%CI 1.674-189.289, P<0.05) were closely related to postoperative recurrence. Kaplan-Meier curve analysis showed that the recurrence rate of atrial fibrillation was significantly lower in patients with an increase in postoperative ejection fraction over 10% (P<0.05).ConclusionMini Maze procedure is safe and effective in the treatment of atrial fibrillation patients with left ventricular systolic dysfunction, which helps to improve left ventricular function to prevent the vicious circle of atrial fibrillation and heart failure.
Objective To summarize the efficacy of aortic arch 1 zone clamping technique in the procedure of ascending aortic aneurysm involving the proximal aortic arch. Methods The clinical data of patients with ascending aortic aneurysm involving the proximal aortic arch who underwent surgical treatment with aortic arch 1 zone clamping technique in our hospital from 2017 to 2019 were retrospectively analyzed. ResultsA total of 35 patients were enrolled, including 21 males and 14 females, with an average age of 63.9±10.8 years. According to different lesions, the proximal aorta underwent Bentall/Carbrol procedure in 8 patients, Wheat in 4 patients, David in 3 patients, and ascending aorta replacement in 20 patients. Distal lesions were completely resected under aortic arch 1 zone clamping technique, and anastomotic reconstruction was performed under hypothermic cardiopulmonary bypass. Distal anastomosis was performed with interrupted suture in 7 patients, and continuous suture with intermittent reinforcement of the posterior wall in 28 patients. All patients successfully completed the procedure. The average cardiopulmonary bypass time was 121.5±28.2 min, the aortic clamping time was 78.1±21.3 min, and the distal anastomosis time was 15.2±3.6 min. One patient underwent a second thoracotomy for hemostasis, and the remaining patients were drained 330.6±108.1 mL on the first day following the procedure. The postoperative mechanical ventilation time of 2 patients exceeded 24 hours, and the main complications were pulmonary infection in 1 patient and acute renal injury in 2 patients. Transient delirium occurred in 2 patients and no transient or permanent neurological dysfunction occurred. The average follow-up time was 2.6±1.1 years. The maximum diameter of the ascending aorta after operation was 30.4±0.9 mm, the diameter of zone 1 aortic arch was 39.8±3.1 mm, and the diameter of the distal aortic arch was 32.3±4.3 mm. There was no lesion in the artificial blood vessels of all patients, and no aneurysms occurred at the proximal or distal anastomosis. No reoperation or intervention was needed for the aorta. ConclusionThe aortic arch 1 zone clamping technique can simplify the procedure of ascending aortic aneurysm involving the proximal aortic arch, reduce or avoid the use of deep hypothermic circulatory arrest, reduce the surgical trauma, and has good short-term and medium-term efficacy.