Objective To investigate the clinical characteristics of unstable pelvic fractures and to find out an alternative for the treatment. Methods From October 2000 to June 2004, fifty-six patients with unstable pelvic fractures were treated by open reduction and pelvic-reconstructed plate fixation to recover the anatomical structure of pelvis and acetabulum. According to Tile classification, 33 cases were type B (15 cases were Tile B1, 11 cases were Tile B2, 7 cases were Tile B3); 23 cases were type C (10 cases were Tile C1, 8 cases were Tile C2, 5 cases were Tile C3). Results The 56 cases were followed up 12 to 68 months(26 months in average).All cases with fractures got healed during 3 to 6 mouths. According to the Majeed evaluation, 40 cases were excellent, 11 cases were good, 4 cases were fair, and only one case was a failure. The rate of excellency and goodness was 91.07%.The pelvic abnormity was rectified; partial patients felt light pain in iliac scar. Conclusion The choice of the proper operative approach and pelvic-reconstructed plate fixation by allowingfor fracture classification is a good and dependable means for treating unstablepelvic fractures.
Objective To investigate the early effectiveness of transiliac-transsacral screws internal fixation assisted by augmented reality navigation system HoloSight (hereinafter referred to as “computer navigation system”) in the treatment of posterior pelvic ring injuries. MethodsA retrospective analysis was made in the 41 patients with posterior pelvic ring injuries who had been treated surgically with transiliac-transsacral screws between June 2022 and June 2023. The patients were divided into navigation group (18 cases, using computer navigation system to assist screw implantation) and freehand group (23 cases, using C-arm X-ray fluoroscopy to guide screw implantation) according to the different methods of transiliac-transsacral screws placement. There was no significant difference in gender, age, body mass index, causes of injuries, Tile classification of pelvic fracture, days from injury to operation, usage of unlocking closed reduction technique between the two groups (P>0.05). The time of screw implantation, the fluoroscopy times, the guide wire adjustment times of each screw, and the incidence of complications were recorded and compared between the two groups. The position of the transiliac-transsacral screw was scanned by CT within 2 days after operation, and the position of the screw was classified according to Gras standard. ResultsThe operation was successfully completed in both groups. The time of screw implantation, the fluoroscopy times, and the guide wire adjustment times of each screw in the navigation group were significantly less than those in the freehand group (P<0.05). There were 2 cases of incision infection in the freehand group, and the incision healed by first intention after active dressing change; there was no screw-related complication in the navigation group during operation and early period after operation; the difference in incidence of complications between the two groups (8.7% vs. 0) was not significant (P=0.495). According to the Gras standard, the screw position of the navigation group was significantly better than that of the freehand group (P<0.05). ConclusionCompared with the traditional freehand method, the computer navigation system assisted transiliac-transsacral screws internal fixation in the treatment of posterior pelvic ring injuries has advantages of improving the accuracy of screw implantation and reducing radiation damage and the time of screw implantation.
Objective To investigate the effectiveness of minimally invasive plate fixation in treatment of unstable pelvic fractures. Methods Between May 2006 and December 2009, 21 patients with unstable pelvic fractures were treated. There were 13 males and 8 females with an average age of 39 years (range, 21-66 years). The causes of injury included traffic accident in 9 cases, falling from height in 6 cases, and heavy pound injury in 6 cases. The time from injury to hospitalization was 1 to 4 hours with an average of 2.8 hours. According to Tile’s classification, there were 12 cases of type B and 9 cases of type C. After admission, bone traction and exo fixation were performed, and minimally invasive plate fixation was given at 5-24 days after injury. Results All incisions healed by first intention, and no complications of nerve and vessel injuries occurred. According to the reduction criteria of Matta radiography, anatomic reduction was achieved in 16 cases, satisfactory reduction in 4 cases, and fair reduction in 1 case. All patients were followed up 12 months. The X-ray films showed all fractures healed at 2-4 months (mean, 2.6 months). According to Majeed clinical evaluation, the results were excellent in 12 cases, good in 7 cases, and fair in 2 cases. Conclusion Minimally invasive plate fixation can provide effective fixation, reconstruct pelvic ring, and reduce perioperative complications in the treatment of unstable pelvic fractures.
ObjectiveTo evaluate the effectiveness of percutaneous retrograde pubic screw implantation assisted by hollow pedicle opener in pubic branch fractures.MethodsThe clinical data of 42 patients with pubic branch fractures treated by hollow screw fixation between March 2008 and March 2019 were analyzed retrospectively. According to the operation method, they were divided into the traditional operation group (20 cases in group A, fixed with traditional retrograde pubic screws) and the modified operation group (22 cases in group B, fixed with percutaneous retrograde pubic screws assisted by hollow pedicle opener). There was no significant difference (P>0.05) between the two groups in terms of gender, age, cause of injury, fracture classification, comorbidity, and time from injury to operation. The operation time, blood loss, incision length, screw length, and complications were recorded and compared between the two groups. The fracture reduction was evaluated according to Matta standard on the next day after operation, and the function was evaluated by Majeed score at 12 months after operation.ResultsThe operation was successfully completed in both groups. The operation time, blood loss, and incision length of group B were significantly less than those of group A (P<0.05); there was no significant difference in screw length between the two groups (t=0.793, P=0.437). All patients were followed up 8-24 months, with an average of 16.8 months. There was no complication in the two groups, such as injury of blood vessels and nerves, fracture of internal fixation, screw entering into joint cavity, and nonunion of fracture. There was no significant difference in the fracture healing time between the two groups (t=−1.068, P=0.299). There were 2 cases of incision infection, 1 case of incision fat liquefaction, 2 cases of lower extremity deep vein thrombosis in group A, the incidence of complications was 25.0%; there was only 1 case of lower extremity deep vein thrombosis in group B, the incidence of complication was 4.5%, which was lower than that in group A, but the difference was not significant (χ2=2.104, P=0.147). In group A, 1 case was found to be dislocated, but in group B, there was no dislocated fracture. There was no significant difference between the two groups in the evaluation of Matta imaging on the next day after operation and the evaluation of Majeed function at 12 months after operation (P>0.05).ConclusionPercutaneous retrograde pubic screw implantation assisted by hollow pedicle opener is effect for the pubic branch fractures with the advantage of smaller incision, shorter operation time, and less bleeding compared with traditional methods.
Objective To investigate the method and the effectiveness of open pelvic fractures associated with perineal injury. Methods Between August 2000 and July 2010, 16 cases of open pelvic fractures associated with perineal injury weretreated. There were 12 males and 4 females with an average age of 41 years (range, 17-69 years). Injury was caused by traffic accidents in 9 cases, by falling from height in 6 cases, and by crushing in 1 case. The mean time between injury and admission was 8 minutes (range, 5-20 minutes). According to Tile classification, 2 cases were rated as type A, 6 as type B, and 8 as type C. The wound size ranged from 5 cm × 3 cm to 15 cm × 12 cm. The perineal injured location included intraperitoneal rectal injury in 2 cases and extraperitoneal anorectal injury in 14 cases. The average injury severity score (ISS) was 29 (range, 25-48). The main treatments included emergency resuscitation, colostomy, external fixation of fractures, repeated debridement with pulsatile irrigation followed by intravenous antibiotics, and vacuum seal ing drainage (VSD). Results In 5 deaths, 3 cases died of hemorrhagic shock and 2 cases died of multi ple system organ failure within 4 days of admission. The other 11 cases were followed up 6-46 months (mean, 14 months). The X-ray films showed that bone union was achieved after 2-4 months of operation. Infection in varying degree occurred at perineal wounds; second stage healing of wounds was achieved in 10 cases after debridement and VSD treatment, and wound healed in 1 case after gracil is muscle flap repair. No anal incontinence occurred in the patients having anorectal injury during follow-up. Conclusion For patients with perineal injury and open pelvic fractures, the following treatments should be carried out so as to obtain good effectiveness: early anti-shock, protection of important organ function, treatment of complications, late resistance to infection and stabil ity restoration of the pelvic ring, functional repair and reconstruction of rectum and anal canal and urinary tract.
Objective To evaluate the security and effectiveness of minimal invasive fixation with fluoroscopybased navigation in the management of pelvic fractures. Methods From April 2007 to June 2008, 22 patients with pelvic fractures were treated with percutaneous screw fixation under the guidance of a fluoroscopy-based navigation system after closed reduction. There were 13 males and 9 females, aged 21-65 years old. Fractures were caused by traffic accident in 17 cases, andfall ing from height in 5 cases. According to AO classification, there were 2 cases of A2.2 type, 2 cases of A2.3 type, 7 cases of B1.2 type, 3 cases of B2.2 type, 1 case of B3.3 type, 2 cases of C1.2 type, 3 cases of C1.3 type, and 2 cases of C2.3 type. The interval from injury to hospital ization was 4 hours to 3 days (mean 1.2 days). After 3-13 days of skeletal traction through tibial tubercle, the operation was performed. Results Totally 42 screws were inserted. The average time for operation was 20.4 minutes per screw. Forty-one screws were inserted correctly with a successful insertion rate of 97.6%, only 1 hollow screw was reinserted for deviation. No incision problem and implant failure occurred. All 22 patients were followed up 7 to 21 months with an average of 14.5 months. At last follow-up, fracture union was achieved in all patients with satisfactory screw fixation. According to Majeed functional scoring, the results were excellent in 18 cases and good in 4 cases, with an excellent and good rate of 100%. Conclusion The minimal invasive fixation with fluoroscopy-based navigation makes the surgery for the pelvic fracture more precise and time-saving, and improves cl inical results without an increasing rate of compl ications.