Objective To explore some operative problems of correcting paralytic scoliosis(PS) by using vertebral pedicle screwsrods system. Methods From May 2000 to May 2005, 18 patients with PS were corrected by screwsrods system which were made of titanium alloy.There were 10 males and 8 females, aging from 11 to 26 years. The primary disease included poliomyelitis in 13 patients and myelodysplasia (MS) in 5 patients (2 cases for second correction) with scoliosis of an average 85° Cobb angle (55-125°). The pelvic obliquity was found in all patients with an average 24° angle (355°).Of the 18 patients,3 cases were given perioperative halo-pelvic traction, 2 cases were given vertebral wedge osteotomy and correction and fixation, the other patients were purely underwent the treatment of pedicle screwrods system implants. Fusion segment at operation ranged from 6 to 15 sections, applied screws the most was 16,the fewest was 6. Results There were no wound infections and neurologic complications, all wounds healed by the first intention. Allscoliosis obtained obvious correction (P<0.001), the correction rate averaged 52.95% (44%-81%); the majority of lumbar kyphosis and pelvic obliquity were apparently corrected. The average clinical follow-up (16 cases) was 21 months(6-36 months),there was no implants failure. One patient with MS had a worse Cobb magnitude, the other patients had no curve progression (P>0.05). Conclusion The use of vertebral pedicle screwsrods fixation to multiple vertebral bodys and short segment fusion for PS, the treatment method is reliable and the outcome is satisfactory. While performing the correcting operative procedures, the spinal, pelvic and lower extremity deformities and functions should be all considered as a whole.
ObjectiveTo explore the effect on sagittal spine-pelvis balance of different fusion segments in anterior cervical discectomy and fusion (ACDF).MethodsThe clinical data of 326 patients with cervical spondylotic myelopathy, treated by ACDF between January 2010 and December 2016, was retrospectively analysed. There were 175 males and 151 females with an average age of 56 years (range, 34-81 years). Fusion segments included single segment in 69 cases, double segments in 85 cases, three segments in 90 cases, and four segments in 82 cases. Full spine anterolateral X-ray films were performed before operationand at 12 months after operation. The spine-pelvis parameters of fusion segments were measured and compared. The parameters included C0-2 Cobb angle, C2-7 Cobb angle, C2-7 sagittal vertical axis (C2-7 SVA), T1 slope (T1S), thoracic inlet angle (TIA), thoracic kyphosis (TK), lumbar lordosis (LL), pelvic incidence (PI), sacral slope (SS), C7 sagittal vertical axis (C7 SVA), T1 pelvic angle (TPA). The Japanese Orthopaedic Association (JOA) score of cervical spine and visual analogue scale (VAS) scores of pain of cervical spine and upper extremity were compared before operation and at 12 months after operation. Pearson correlation analysis was performed on LL, PI, SS, C7 SVA, and TPA before and after operation to evaluate the changes of spine-pelvis fitting relationship after ACDF.ResultsAll 326 patients were followed up 12-32 months (mean, 18.5 months). During the follow-up period, internal fixator was in place, and no spinal cord nerve or peripheral soft tissue injury was found. JOA scores and cervical VAS scores improved significantly at 12 months after operation (P<0.05), no significant difference was found in VAS scores of upper extremity when compared with preoperative scores (P>0.05). The preoperative cervical VAS scores and the postoperative JOA scores at 12 months had significant differences between groups (P<0.05). At 12 months after operation, there was no significant difference in sagittal spine-pelvis parameters in the single segment group compared with preoperative ones (P>0.05); but the C0-2 Cobb angle, C2-7 Cobb angle, C2-7 SVA, T1S, TIA, C7 SVA, and TPA in the double segments, three segments, and four segments groups were significant larger than preoperative ones (P<0.05). The C0-2 Cobb angle, C2-7 Cobb angle, T1S, C7 SVA, and TPA among 4 groups had significant differences before operation and at 12 months after operation (P<0.05). At 12 months after operation, the changes of C7 SVA and TPA in the double segments, three segments, and four segments groups were significantly larger than those in the single segment group (P<0.05). PI had positive correlations with LL and SS before and after operation in 4 groups (P<0.05).ConclusionNormal fitting relationship between lumbar spine and pelvis in physiological state also exists in patients with cervical spondylotic myelopathy, and ACDF can not change this specific relationship. In patients with cervical spondylotic myelopathy, the sagittal spine-pelvis sequence do not change after ACDF single-level fusion, while the sagittal spine-pelvis balance change after double-level and multi-level fusion.
Objective To investigate the biomechanical differences of three internal fixation approaches, namely improved Galveston (IG), reconstruction plate (RP), and il iosacral screw (LS) to the posterior pelvic ring fracture dislocation and provide experimental evidence for the cl inical appl ication of proper internal fixation method. Methods Six donatedfresh adult cadaver pelvic specimens (age averaged 45 years old) were numbered randomly and their normal biomechanics were tested by the measure instrument (MTS855 Mini-Blonix). The displacement values of normal pelvis were measured under the vertical compression (800 N) and reverse direction compression (8 N·m). Then they were made into left Denis I pelvic fracture and fixed with the IG, RP, and LS, respectively, in different orders. Biomechanics test was conducted on the fixed pelvis from both the vertical and the reversed directions. Results Concerning the direction of vertical ity and torsion, the order of fracture displacement from small to large was the normal pelvis, LS, IG and RP. There was no significant difference between LS and the normal pelvis (P gt; 0.05), and the differences between other tow groups were significant (P lt; 0.05). Conclusion The LS fixation can provide better stabil ity for posterior pelvic ring fracture dislocation when compared with IG and RP.
Objective To explore the choice for the internal fixation in treatment of pelvic posterior lesions. Methods From May 2000 to June 2005, the treatment was given to 40 patients (28 males, 12 females,aged 21-58 years) with pelvic posterior ring fracture and dislocation. Of the patients, 23 had a traffic accident, 11 had a crush injury and 6 had a fall. As for the state of an injury to the pelvic posterior ring, 22 patients had disloation of the sacroiliac joint, 12 had a sacrum fracture dislocation, and 6 had an ala iliac fracture and disloation of the sacroiliac joint. According to the Denis(1988) classification, fracture of the (sacral region Ⅰ was found in 6 cases, fracture of the scaral) region Ⅱ in 3 cases, and fracture of the scaral region Ⅲ in 3 cases. As for the complication of the pelvic front ring fracture:separation of the symphysis pubis was found in 14 cases, fraclure of the superior ramus and inferior ramus of the pubis on one side in 10 cases. The two-side superior ramus of publis and inferion ramus of pubisin 8 cases, homopleural acetabular fracture on one side in 4 cases, acetabularfracture on one side and contralateral superior ramus and inferior ramus fracture of the pubis in 3 cases, and acetabular fracture on the opposite side in 1 case.As for the operation, 28 patients underwent the stillplate internal fixation of the sacroiliac joint from anterior at 24 h to 15 days after the injury, 2 underwent the screwinternal fixation of the sacroiliac joint from posterior, and remaining 10 underwent the internal fixation by the Galveston Technique associated with the ISOLAsystem. The therapeutic results were analyzed. Results The followup of the 40 patients for 6 months to 3 years revealed that before operation 3 had a sacral plexus nerve injury, and after operation 1 patient developed perineum numbness and urinary incontinence, 1 developed claudication,3 developed posterior urethral fragmentation, and 2 developed urinary bladderrupture; however, they had a complete recovery after the reparative surgery. Conclusion In treatment of the pelvic posterior ring lesions,an appropriate internal fixation can be chosen according to the type of the pelvic fracture,applicability of internal fixation, condition of the patient,equipment available, and the doctor’s experience.
Objective To evaluate the surgical procedure of reinforced acetabular cage with caudal flange in reconstruction of pelvic defect after acetabular tumor resection. Methods Between June 2003 and December 2009, 25 patients with Harrington class III pelvic defect underwent reconstruction with a reinforced acetabular cage with caudal flange and total hip arthroplasty (THA). There were 13 males and 12 females with an average age of 51.2 years (range,13-73 years). The main cl inical manifestations included hip pain and buttock pain, with a median disease duration of 6 months (range, 1-96 months). Pathological findings showed 18 cases of metastasis, 3 cases of multiple myeloma, 1 case of non-Hodgkin’s lymphoma, 1 case of grade I chondrosarcoma, 1 case of giant cell tumor, and 1 case of chondroblastoma. For the patient with chondroblastoma, THA with LINK RIBBED system was used. An artificial total hip system made in China was used in 6 patients and LINK SP II system was used in the other 18 patients. Results No patients died perioperatively. Deep infection and hip dislocations occurred in 1 and 2 patients, respectively. At last follow-up, 8 of 18 patients with metastasis died of cancer and the average survival time was 11 months. The other 10 who were al ive were followed up 15 months on average. One patient with multiple myeloma died of pulmonary infection at 21 months after operation and the other 2 with multiple myeloma and 1 with lymphoma were al ive with an average follow-up of 17 months. The patient with grade I chondrosarcoma and patient with chondroblastoma were followed up 58 and 12 months, respectively, without recurrence. Recurrence occurred in the patient with giant cell tumor at 19 months afteroperation. Loosening of implant occurred in 3 patients because of local tumor recurrence. For the 23 patients at 6 months after operation, the mean Musculoskeletal Tumor Society (MSTS) 93 score was 81% (range, 57%-93%). Conclusion Reinforced acetabular cage with caudal flange could be used together with THA for reconstruction of Harrington class III pelvic defects after acetabular tumor resection, and low incidence of postoperative compl ication and good functional outcome could be expected.
ObjectiveTo explore the value of the long time lower abdominal aorta balloon block technology in the pelvis or sacrum tumor surgery. MethodsFrom January 2005 to June 2013, the sacrum or pelvic tumor patients underwent the long time lower abdominal aorta balloon block technology in the Orthopedics Department of West China Hospital of Sichuan University were enrolled. According to the balloon blocking time, patients were divided into A (<90 mins), B (90 to 180 mins), and C (>180 mins) groups. The intraoperative blood loss, blood transfusion amount, average lengths of hospital stay, postoperative volume of drainage, and postoperative complications were compared among the three groups. ResultsA total of 78 patients were included, of which 21 were in group A, 38 were in group B and 19 were in group C. All patients received en bloc resection, and did not experience intraoperative balloon shift and abdominal aorta flow leakage. Comparing the three groups, there were significant differences in intraoperative blood loss (P=0.026) and average lengths of hospital stay (P=0.021). Further pairwise comparison showed the intraoperative blood loss and average lengths of hospital stay in group C were significantly higher than those in group A and group B. In addition, there were no statistical differences among the three groups in blood transfusion amount, postoperative volume of drainage and postoperative complications. ConclusionIn the pelvis and sacrum tumor surgery, extending the time of abdominal aorta balloon block can reduce bleeding, save blood, increase the safety of surgery without increasing in postoperative complications.
【Abstract】 Objective To evaluate the effectiveness of percutaneous fixation of pelvic fracture by Acutrak full thread headless hollow compression screw. Methods Between March 2008 and April 2010, 31 patients with pelvic fracture underwent percutaneous fixation surgery with Acutrak full thread headless hollow compression screw (surgical group). The effectivenss was compared with those of 14 patients with pelvic fracture treated conservatively (control group). There was no significant difference in age and sex between 2 groups (P gt; 0.05). The injury was more severe in surgical group than in control group. The standard of short-term recovery was active turning over and walking for 5 steps with walking aids. The standard of long-term recovery was pain, gait, fracture healing, and function recovery. Results In surgical group, the other patients reached the standard of short-term recovery at 1-4 days after injury except 1 patient who had sacral plexus injury; in control group, the patients could turn over at 9-13 days (Tile type A2) and 17-25 days (Tile type B2) respectively, and could walk at 17-21 days (Tile type A2) and at 45-57 days (Tile type B2) respectively. The patients of 2 groups were followed up 6-19 months. The time of fracture healing was 2-6 months. The long-term results were excellent in 29 cases and good in 2 cases in surgical group, and were excellent in 8 cases and good in 6 cases in control group, showing significant difference between 2 groups (χ2=6.636, P=0.017).Conclusion Percutaneous internal fixation combined with Acutrak full thread headless hollow compression screw can provide more effective treatment. It can alleviate patients, pain quickly, improve life quality, and has better long-term effectiveness.
ObjectiveTo evaluate the effectiveness of TiRobot-assisted surgery by O-arm navigation system for percutaneous minimally invasive treatment of posterior pelvic ring injury. Methods The clinical data of 76 patients with posterior pelvic ring injury between January 2016 and June 2021 were retrospectively analyzed. Among them, 45 cases were treated with minimally invasive percutaneous sacroiliac screw fixation assisted by TiRobot and O-arm navigation system (study group), 31 cases were treated with minimally invasive percutaneous sacroiliac screw fixation under the guidance of C-arm X-ray machine (control group). There was no significant difference in gender, age, cause of injury, Tile classification, time from injury to operation between the two groups (P>0.05). The operation time, intraoperative blood loss, the times of nail track adjustment, and intraoperative fluoroscopy times were recorded. The quality of fracture reduction was evaluated by Matta score. At last follow-up, Majeed score was used to evaluate the recovery of pelvic function. ResultsA total of 72 screws were implanted in the study group, with a median of 1 (1, 2) screws per patient. In the control group, 47 screws were implanted, with a median of 1 (1, 2) screws per patient. There was no significant difference in the number of screws between the two groups (Z=−0.392, P=0.695). The operation time, intraoperative blood loss, times of nail track adjustment, and intraoperative fluoroscopy times in the study group were significantly less than those in the control group (P<0.05). All patients were followed up 6-24 months (mean, 14 months). No serious complications was found after operation and during follow-up. Matta score was used to evaluate the quality of fracture reduction at 1 week after operation, and there was no significant difference between the two groups (Z=−1.135, P=0.256). At last follow-up, there was no significant difference of Majeed score between the two groups (Z=−1.279, P=0.201). ConclusionTiRobot-assisted surgery by O-arm navigation system is a reliable surgical method for the treatment of posterior pelvic ring injury, which can reduce the operation time and fluoroscopy times when compared with the traditional operation under the guidance of C-arm X-ray machine. The safety, accuracy, and efficiency of the operation were improved.