Objective To investigate the effectiveness of MAKO robotic-arm assisted total hip arthroplasty (THA) via direct anterior approach (DAA) for bony fused hips in ankylosing spondylitis (AS). Methods Between June 2021 and January 2022, MAKO robotic-arm assisted THA via DAA was applied to treat 10 cases (12 hips) of AS with bony fused hips. There were 7 males and 3 females; the age ranged from 30 to 71 years, with an average age of 42.4 years. The duration of AS was 12-35 years, with an average of 21.4 years. The preoperative hip was ankylosed in flexion in 3 cases, with a flexion angle of 20°, 30°, 35°, respectively; 9 cases were ankylosed in extension. The operation time and complications were recorded; the visual analogue scale (VAS) score, Harris score, and Oxford hip scale (OHS) score before and after operation, and postoperative range of motion (flexion, extension, internal rotation, external rotation, adduction, and abduction) were used to evaluate the recovery of joint function; according to the postoperative anteroposterior X-ray film and CT scan of both hip joints, the abduction angle, anteversion angle, the difference between bilateral combined off-set and the lower limb length discrepancy were measured. Results The operation time ranged from 80 to 190 minutes (mean, 134.6 minutes). All 10 patients were followed up 5-11 months (mean, 7.4 months). There was no serious adverse events such as incision infection, deep vein thrombosis of lower extremities, hip redislocation, aseptic loosening of the prosthesis, or death. At 5 months after operation, the acetabular prosthesis angle of abduction was 37°-45° (mean, 40.3°), anteversion angle was 9°-20° (mean, 15.8°). The difference between bilateral combined off-set was 0-10 mm (mean, 4.3 mm); the lower limb length discrepancy was 0-12 mm (mean, 3.5 mm). At last follow-up, the average range of motion of the hip joint was 89.2° in flexion (range, 80°-100°), 1.7° in extension (range, –5°-10°), 7.1° in internal rotation (range, 0°-15°), 20.4° in external rotation (range, 10°-30°), 7.9° in adduction (range, 0°-20°), and 16.5° in abduction (range, 10°-25°). At last follow-up, the VAS score, Harris score, and OHS score significantly improved when compared with those before operation (P<0.05). ConclusionThe MAKO robotic-arm assisted THA via DAA can achieve satisfactory results in the treatment of AS with bony fused hip, which has the advantages of accurate prosthesis installation, soft tissue release, and less trauma during operation.
Objective To investigate the relationship between the vertical distance from semitendinosus insertion to tibial plateau (S-T) and the physical characteristics of patients, in order to provide reference for incision design to expose the semitendinosus insertion. Methods The patients with ligament injury who underwent primary anterior cruciate ligament reconstruction between January 2022 and December 2022 were selected as the research subjects. The patients’ baseline data were collected, including age, gender, height, and body mass. During reconstruction operation, the S-T was measured. Considering the S-T as the dependent variable and baseline data as the independent variable, multiple linear regression analysis was used to establish a regression equation to determine the possible influencing factors of semitendinosus insertion location. Results According to the selection standard, a total of 214 patients were enrolled, including 156 males and 58 females, aged (27±9) years (14-49 years), with a height of (174.7±6.8) cm (range, 160-196 cm) and a body mass of (73.43±12.35) kg (range, 53-105 kg). The S-T was (56.36±3.61) mm (range, 47-67 mm). The multiple linear regression analysis results showed that the height was positively correlated with S-T (β=0.407, SE=0.055, t=7.543, P<0.001); the regression equation was S-T=−14.701+0.407×height, R2=0.690. ConclusionThere was a linear relationship between the height and semitendinosus insertion. The location of semitendinosus insertion estimated by the formula (S-T=−14.701+0.407×height) is reasonable, which provides a theoretical basis for rapid, accurate, and safe location of semitendinosus insertion and design of surgical incision in clinic.
ObjectiveTo investigate the feasibility and effectiveness of “tail compression fixation+suture bridge” technology under shoulder arthroscopy for treating primary tear in medial enthesis of rotator cuff. Methods The clinical data of 11 patients with primary tear in medial enthesis of rotator cuff who met the selection criteria between October 2020 and October 2022 were retrospectively analyzed, including 3 males and 8 females, aged 39-79 years, with an average of 61.0 years. Rotator cuff injury was caused by traumatic fall in 8 cases, and the time from injury to admission was 1-4 months, with an average of 2.0 months; the remaining 3 cases had no obvious inducement. The active range of motion of the affected shoulder was limited, with an active forward flexion range of motion of (64.1±10.9)°, abduction of (78.1±6.4)°, internal rotation of (48.2±6.6)°, and external rotation of (41.8±10.5)°; 5 cases had shoulder stiffness. The preoperative visual analogue scale (VAS) score was 7.8±0.8 and the American Society of Shoulder and Elbow Surgeons (ASES) score was 23.9±6.4. The patients were treated with “tail compression fixation+suture bridge” technology under shoulder arthroscopy, and the pain and functional recovery were evaluated by VAS score, ASES score, and active range of motion of shoulder joint at last follow-up; MRI was performed after operation, and the integrity of rotator cuff was evaluated by Sugaya classification system. Results All the 11 patients were followed up 2-22 months, with an average of 13.5 months. All incisions healed by first intention, and there was no complication such as infection, rotator cuff re-tear, and anchor falling off. At last follow-up, the VAS score was 0.8±0.7 and the ASES score was 93.5±4.2, which significantly improved when compared with those before operation (P<0.05). All 11 patients had no significant swelling in the shoulders, and the active range of motion was (165.1±8.8)° in flexion, (75.3±8.4)° in abduction, (56.6±5.5)° in internal rotation, and (51.8±4.0)° in external rotation, which significantly improved when compared with those before operation (P<0.05). Shoulder MRI showed adequate tendon thickness and good continuity in 9 cases, including 4 cases with partial high signal area; and 2 cases with inadequate tendon thickness but high continuity and partial high signal area. According to Sugaya classification system, there were 4 cases of type 1 (36.4%), 5 cases of type 2 (45.5%), and 2 cases of type 3 (18.1%).Conclusion For the patients with primary tear in medial enthesis of rotator cuff, the “tail compression fixation+suture bridge” technology under shoulder arthroscopy is simple and effective.