west china medical publishers
Author
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Author "CHEN Hua" 36 results
  • The Effects of Somatostatin Analogue on Proliferation and Apoptosis of Human Cholangiocarcinoma Cell Line

    Objective To investigate the regulatory effect of somatostatin analogue (SMS201995,SMS) on proliferation and apoptosis in human cholangiocarcinoma cell line in vitro. MethodsProliferation curve, flow cytometry, agarose gel electrophoresis, Annexin VFITC and flow cytometric immunofluorescent technique were performed to identify the inhibitory effect on cell proliferation and the induction of apoptosis of human cholangiocarcinoma cells (SKChA1). ResultsSMS significantly reduced the SKChA1 cell growth by serum in long experiments and transiently accumulated it in G0/G1 phase. Dotplot analysis of cells duallabeled with Annexin VFITC and PI confirmed the induction of apoptosis by SMS in SKChA1 cells.AnnexinVFITC labeling was markedly enhanced following treatment with SMS for 24 h. DNA of treated SKChA1 cells appeared a ladder pattern characteristic of apoptosis. Besides, timedependent increase in bax and decrease in bcl2 occured during SMS treatment. Conclusion SMS could inhibit the proliferation activity and induce apoptosis of cholangiocarcinoma cell line SKChA1. The mechanisms of apoptosis might be correlated with the expression of apoptosisregulatory gene bax and bcl2.

    Release date:2016-08-28 05:11 Export PDF Favorites Scan
  • Experience of Cooperation of Surgical Nurses in Hybrid Surgery for Complex Cerebral and Spinal Vascular Diseases

    目的 总结神经外科复杂脑脊髓血管病杂交手术的护理配合经验。 方法 回顾分析2011 年4 月-2012 年5月华西医院手术室完成的 56例神经外科杂交手术的临床资料,总结神经外科杂交手术的护理配合经验。 结果 所有手术均顺利进行,未出现明显危及患者安全的情况。 结论 神经外科Hybrid手术治疗复杂脑脊髓血管病较普通手术更为安全有效。但手术护理准备及配合更为复杂,在手术室布局、手术流程方面需要医护协调专门进行优化。有神经外科专业经验的护士经过一段时间专门培训后担任手术巡回及器械护士更有利于手术的顺利、安全进行。

    Release date:2016-09-07 02:34 Export PDF Favorites Scan
  • Recent advances in treatment of aseptic femoral shaft nonunion

    Objective To review the recent advances in treatment of aseptic femoral shaft nonunion. Methods The clinical studies about the treatments of aseptic femoral shaft nonunion in recent years were widely reviewed and analyzed. Results There are several surgical methods for aseptic femoral shaft nonunion. Due to uncertain clinical outcome, dynamization of nail should be carefully selected. The exchange nailing is suitable for the hypertrophic nonunion of the isthmal femoral shaft fracture. The exchange lateral plating is suitable for nonunion with obvious malformation. However, wave plate or dual plate should be chosen when the bone nonuinon is combined with the medial defect. The augmentation plating improves the success rate of nailing for femoral shaft nonunion, but it should be carefully selected for patients with obvious deformity or bone defect. Ilizarov technique is suitable for various bone nonunion, especially with complicated or large segmental bone defects. Induced membrane technique is also an important method for the treatment of bone nonunion with large bone defects. The clinical efficacy of the blocking screw remains to be supported by further evidence. Biological stimulants are mainly used for atrophic nonunion, and the clinical efficacy of them alone are still controversial. Conclusion Due to lack of comparative studies between different surgical methods, the orthopedist should choose the appropriate treatment according to the individual situations of the patient and the types of bone nonunion.

    Release date:2018-05-02 02:41 Export PDF Favorites Scan
  • Laparoscopic spleen-preserving distal pancreatectomy: a report of 17 cases

    Objective To evaluate feasibility and clinical application value of laparoscopic spleen-preserving distal pancreatectomy (LSPDP). Method The clinical data of 17 patients underwent LSPDP from January 2015 to June 2017 in this hospital were retrospectively analyzed. Results The LSPDP was successfully completed in the 17 cases, with Kimura procedure and Warshaw procedure were performed in the 12 cases and 5 cases, respectively. The operative time was (218±60) min, the intraoperative blood loss was (136±114) mL, the time to get out of bed after surgery was (1.4±0.6) d, the postoperative fasting time was (2.0±0.8) d, and the postoperative hospital stay was (13.4±5.7) d. The rate of the postoperative pancreatic fistula was 17.6% (3/17). The spleen infarction occurred in the 2 cases following the Warshaw procedure. The pathologic examination showed that there were 2 patients with the serous cystadenoma, 7 patients with the mucinous cystadenoma, 3 patients with the solid pseudo-papillary tumor, 3 patients with the intraductal papillary mucinous cystadenoma neoplasm, and 2 patients with the insulinoma. All the patients were followed-up for 5 to 26 months (average 13 months), and the perigastric varice occurred in 1 patient, no recurrence or spleen infarction occurred during the following-up. Conclusion LSPDP is a safe, feasible and effective method with less injury and rapid recovery.

    Release date:2018-08-15 01:54 Export PDF Favorites Scan
  • Research progress of augmentation plate for femoral shaft nonunion after intramedullary nail fixation

    ObjectiveTo review the history, current situation, and progress of augmentation plate (AP) for femoral shaft nonunion after intramedullary nail fixation.MethodsThe results of the clinical studies about the AP in treatment of femoral shaft nonunion after intramedullary nail fixation in recent years were widely reviewed and analyzed.ResultsThe AP has been successfully applied to femoral shaft nonunion after intramedullary nail fixation since 1997. According to breakage of the previous nailing, AP is divided into two categories: AP with retaining the previous intramedullary nail and AP with exchanging intramedullary nail. AP is not only suitable for simple nonunion, but also for complex nonunion with severe deformity. Compared with exchanging intramedullary nail, lateral plate, and dual plate, AP has less surgical trauma, shorter healing time, higher healing rate, and faster returning to society. However, there are still some problems with the revision method, including difficulty in bicortical screw fixation, lack of anatomic plate suitable for femoral shaft nonunion, and lack of postoperative function and quality of life assessment.ConclusionCompared with other revision methods, AP could achieve higher fracture healing rate and better clinical prognosis for patients with femoral shaft nonunion. However, whether patients benefit from AP in terms of function and quality of life remain uncertain. Furthermore, high-quality randomized controlled clinical studies are needed to further confirm that AP are superior to the other revision fixations.

    Release date:2019-12-23 09:44 Export PDF Favorites Scan
  • Application of three-dimensional navigation template in adult cubitus varus osteotomy

    ObjectiveTo investigate the effectiveness of three-dimensional (3D) navigation template in the adult cubitus varus osteotomy.MethodsBetween April 2013 and September 2015, 17 patients with cubitus varus were admitted. There were 6 males and 11 females, aged from 19 to 38 years, with an average age of 26.9 years. There were 10 cases of left elbow joints and 7 cases of right elbow joints. The disease duration was 9-30 years (mean, 18 years). Based on the preoperative X-ray film, the humerus-elbow-wrist (HEW) angle was (−13.2 ±3.3)°, the anteversion angle was (−10.5±2.3)°. The preoperative range of motion (ROM) of flexion was (127.3±7.3)° and ROM of extension was (−10.0±2.5)°. Based on the CT 3D reconstruction, the osteotomy navigation template was designed and printed by 3D printing technique. The cubitus varus osteotomy was assisted by 3D navigation template. The postoperative HEW angle, anteversion angle, and ROMs of the elbow joints of both sides were measured. The elbow function was evaluated based on the Oppenheim elbow function score at 1 year after operation.ResultsAll cubitus varus osteotomies succeeded with the assist of 3D navigation template. All incisions healed by first intention. All patients were followed up 12-15 months (mean, 13 months). X-ray films showed that all osteotomies healed after 9-12 weeks (mean, 11 weeks). At 1 year after operation, the HEW angle was (9.7±1.9)°, the anteversion angle was (20.7±4.3)°, the ROM was (2.6±3.5)° in extension and (139.2±4.8)° in flexion of affected side. The HEW angle, anteversion angle, and ROMs significantly increased compared with preoperative values (P<0.05). And there was no significant difference between affected and normal elbow joints (P>0.05). The elbow functions were excellent in 13 cases and good in 4 cases based on the Oppenheim elbow function score at 1 year after operation. There was no complication such as the nerve injury or osteomyositis of elbow joint during follow-up. ConclusionThe 3D navigation template can provide a personalized and precise osteotomy treatment for adult cubitus varus deformity and obtain a satisfactory effectiveness.

    Release date:2020-07-27 07:36 Export PDF Favorites Scan
  • Research progress on medial support augmentation of plate osteosynthesis for proximal humeral fractures

    ObjectiveTo review the literature about the clinical application and research progress on medial support augmentation of plate osteosynthesis for proximal humeral fractures, and to provide reference for clinical treatment.MethodsThe literature concerning medial support augmentation of plate osteosynthesis for proximal humeral fractures in recent years was extensively reviewed, as well as the biomechanical benefit and clinical advantage were analyzed thoroughly.ResultsMedial support augmentation of plate osteosynthesis for proximal humeral fractures is very important, especially in osteoporotic and/or comminuted fractures. Many medial support augmentation methods have been proposed which can be divided into extramedullary support and intramedullary support. It can also be divided into autogenous bone support and allogenic bone support according to the material and source, divided into medial column support, calcar support, and humeral head support according to the support site, and divided into fibular shaft support, femoral head support, anatomic fibula support according to the shape of the augmented fixation. At present, clinical and biomechanical researches show that medial support augmentation is an effective treatment for proximal humeral fractures.ConclusionAs an important treatment strategy for the treatment of proximal humeral fractures, the medial support augmentation of plate osteosynthesis gets the focus from the biomechanical studies and clinical treatment. However, there are still widespread controversies among orthopedic surgeons regarding the support mode, site, implant shape, and material of medial column support for augmentation of proximal humeral fractures. More high-quality clinical trials and biomechanical researches as well as multi-disciplinary integration, are needed to provide better strategy treatment for the treatment of proximal humeral fractures.

    Release date:2021-03-26 07:36 Export PDF Favorites Scan
  • Application of channel-assisted minimally invasive repair system in Myerson types ⅠandⅡ chronic Achilles tendon rupture

    ObjectiveTo investigate the effectiveness of channel-assisted minimally invasive repair system (CAMIR) in treatment of the Myerson types Ⅰ and Ⅱchronic Achilles tendon rupture.MethodsBetween May 2016 and August 2017, 19 patients with Myerson types Ⅰ and Ⅱchronic Achilles tendon ruptures were treated with CAMIR. There were 14 males and 5 females, aged from 21 to 48 years, with an average age of 34.5 years. The disease duration was 5-9 weeks (mean, 7.5 weeks). The preoperative Thompson tests of affected ankles showed positive. There were 11 cases of Myerson type Ⅰwith the gaps of Achilles tendon defect of 1-2 cm (mean, 1.58 cm), and 8 cases of Myerson type Ⅱwith the gaps of Achilles tendon defect of 2.5-4.0 cm (mean, 3.16 cm). The ankle dorsiflexion and plantarflexion range of motion were measured before and after operation; the American Orthopedic Foot and Ankle Society (AOFAS) ankle and hindfoot score was used to assess the patients’ ankle joint function.ResultsNo major blood vessels, nerves, and other tissue structures were damaged during the operation; 3 cases of Myerson type Ⅰ were converted to Myerson type Ⅱ according to the gaps of the defect after the scar tissue was removed during the operation. After operation, the depressed part of the Achilles tendon disappeared, the continuity of the tendon was restored, and the Thompson tests were negative. All 19 patients were followed up 12-25 months, with an average of 14 months. All incisions healed by first intention, and no infection and skin necrosis occurred; all the pre-injury activities and exercise were restored at 6 months after operation. During the follow-up period, no heel pain or re-rupture occurred. At last follow-up, except that there was no significant difference in ankle dorsiflexion range of motion of Myerson type Ⅰ patients (t=2.118, P=0.071), the AOFAS ankle and hindfoot score, ankle plantarflexion range of motion of Myerson types Ⅰ and Ⅱ patients, and ankle dorsiflexion range of motion of Myerson type Ⅱ patients were significantly improved when compared with preoperative values (P<0.05). According to AOFAS ankle and hindfoot function score, the ankle joint function of type Ⅰ patients was excellent in 7 cases and good in 1 case, and of type Ⅱ patients were excellent in 8 cases, good in 2 cases, and fair in 1 case.ConclusionCAMIR is safe and effective in the treatment of Myerson types Ⅰ and Ⅱ chronic Achilles tendon rupture with fewer complications and better functional recovery of ankle joint.

    Release date: Export PDF Favorites Scan
  • MECHANISMS, PREVENTION, AND TREATMENTS OF PROSTHETIC ASEPTIC LOOSENING

    Objective To introduce the occurrence mechanisms, prevention, and treatment measures of prosthetic aseptic loosening. Methods The recent original articles about prosthetic aseptic loosening were extensively reviewed and analyzed. Results Prosthetic aseptic loosening was a very complex process involving many mechanical and biological aspects. The main mechanical factors included prosthetic materials, shapes and sizes, implant fixation methods (including surfacetreatments), cl inical installation, interface micromotion, stress shielding, implant wear, interface integrity, and peri prosthetic high hydraulic pressure, etc.; the main biological factors included the types and sizes of wear particles, cell-activated responses, cytokine release, enzyme activation and allergic reactions to wear particles, etc.. Many measures should be adopted to effectively prevent and treat it, including improving materials and designs of prostheses, fixation techniques, surgical techniques, and drug treatments. Conclusion Prosthetic aseptic loosening is still a troublesome compl ication after joint replacements in orthopaedics, and more attention should be paid for its effective prevention and treatment.

    Release date:2016-08-31 05:47 Export PDF Favorites Scan
  • The value of platelet volume indices in early period as prognostic indicators of sepsis

    ObjectiveTo investigate the prognostic value of platelet volume indices [mean platelet volume (MPV) and platelet distribution width (PDW)] in early period for patients with sepsis .MethodsThis retrospective study was conducted in a general ICU at a University Hospital from January 2015 to January 2017. Patients with sepsis were divided into a survival group and a death group according to 28-day prognosis. The demographic and clinical data were recorded and analyzed, including platelet indices, Charlson comorbidity index, Glasgow Coma Scale (GCS) score and Acute Physiology and Chronic Health Evaluation Ⅱ (APACHEⅡ) score. Multivariable COX proportional hazard ratio model was used to evaluate the 28-day mortality risk, and receiver operating characteristic (ROC) curve were used to evaluate the value of platelet volume indices.ResultsA total of 209 patients were enrolled in this study. Mean arterial pressure, pH, platelet count, serum creatinine, bilirubin, troponin I, prothrombin time, GCS score and platelet volume indices showed significant differences between the survival group (n=137) and the death group (n=72) (all P<0.05). Multivariable COX regression analysis revealed that the PDW was independently associated with 28-day mortality in sepsis (HR=1.068, 95%CI 1.002-1.139, P=0.043). The area under the ROC curve of PDW was 0.762 (95%CI 0.694 - 0.831), with a sensitivity of 86% and a specificity of 63% at a cut-off value of 18.65%.ConclusionPDW can be used as a powerful prognostic indicator in patients with sepsis following 28-day.

    Release date:2019-07-19 02:21 Export PDF Favorites Scan
4 pages Previous 1 2 3 4 Next

Format

Content