west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Cardiac valve" 24 results
  • Efficacy of Salvianolate on Myocardium Protection in Extracorporeal Circulation of Cardiac Valve Replacement

    Abstract: Objective To investigate the effect of salvianolate on myocardium against ischemiareperfusion injury (IRI) in valve replacement with cardiopulmonary bypass (CPB), its outcome and mechanism, and the applicability and safety of salvianolate as a protection agent for CPB central muscles. Methods Thirty patients undergoing cardiac valve replacement were randomly divided into two groups by lot. In the control group, there were 15 patients including 5 males and 10 females, while in the 15 patients in the trial group, 7 were male and 8 were female. Salvianolate of 200 mg was given to the patients in the trial group intravenously. Hemodynamic parameters, blood gas analysis results, recovery of heartbeat, the dosage of dopamine used, and assisted ventilation time were recorded for both groups before aorta clamping, 2 h, 8 h, and 24 h after aorta declamping. Besides, ICU detention time, the amount of urine in 24 hours, and the amount of drainage in 24 hours after operation were also recorded. Blood samples were taken to determine serum cardial troponin I(cTnI), creatine kinase MB isoenzyme (CK-MB), malondialdehude (MDA), and superoxide dismutase (SOD) in both groups respectively at different times including after the induction of anesthesia, aorta opening, termination of CPB, end of operation, and one day after operation. Results There was no significant difference in hemodynamic parameters, the dosage of dopamine used, spontaneous recovery of heartbeat, and the amount of urine in 24 hours and drainage after operation for 24 hours between the two groups (Pgt;0.05). The rate of ventricular rhythm, blood lactic acid level, the time of assisted ventilation and ICU detention time for the trial group were significantly lower than those for the control group (Plt;0.05), while partial pressure of oxygen in artery(PaO2) was significantly lower in the trial group 8 h after aorta declamping (Plt;0.05). The levels of serum CK-MB, cTnI, and MDA after operation for both groups were higher than those before operation; and those levels for the trial group were significantly lower than the control group at various time points (Plt;0.05). The concentration of SOD decreased after operation in both groups (Plt;0.05), and it was higher in the trial group than the control group at different time points. The decrease of SOD level in the trial group was less than that in the control group. Conclusion Salvianolate can protect myocardium from ischemiareperfusion injury in cardiac valve replacement with CPB effectively, through promoting the activity of antioxidative enzymes and eliminating oxygen free radicals. Patients can be treated with salvianolate for antimyocardial ischemia reperfusion injury.

    Release date:2016-08-30 05:57 Export PDF Favorites Scan
  • Effect of early postoperative enteral nutrition support on the levels of free amino acids in plasma for patients with cardiac valve replacement

    Objective To investigate the effect of early postoperative enteral nutrition support on the balance of free amino acid spectrum in plasma for patients with cardiac valve replacement during perioperative period. Methods (Forty-seven) patients undergoing cardiac valve replacement were divided into two groups randomly, the routine diet group and the Nutrison Fibre group. The levels of free amino acids in plasma were measured with pre-column derivatization of high-performance liquid chromatography. Results During perioperative period most free amino acids in plasma decreased significantly in the routine diet group (Plt;0.05). Despite some free amino acids in plasma decreased significantly in the Nutrison Fibre group(Plt;0.05), all free amino acids in plasma returned to (Pgt;05) or were higher than the preoperative levels in the postoperative sixth day (Plt;0.05). At the same postoperative points, most free amino acids in plasma in the Nutrison Fibre group were higher than that of the routine diet group (Plt;0.05). Conclusions The levels of free amino acids in plasma decrease significantly in patients with cardiac valve replacement after operation. Early postoperative Nutrison Fibre enteral nutrition support is helpful for keeping the balance of free amino acids in plasma for patients with cardiac valve replacement.

    Release date:2016-08-30 06:28 Export PDF Favorites Scan
  • Nontransplantation Surgical Cardiac Remodeling Operation for Endstage Cardiac Valve Disease

    Objective To evaluate the effectiveness and prospect of nontransplantation surgical cardiac remodeling for endstage cardiac valve disease by performing the remodeling operation (including anatomical and functional remodeling) after strict perioperative adjustment for endstage cardiac valve disease. Methods We retrospectively analyzed the clinical data of 31 patients, including 14 males and 17 females, with endstage cardiac valve disease who were treated with surgical cardiac remodeling operation from December 2005 to July 2009 in the 2nd Hospital of Anhui Medical University . Their age ranged from 27 to 74 years with an average age of 40.4 years. Continuous renal replacement therapy (CRRT) was carried out 3 days before surgery in all patients and intraaortic balloon pumping (IABP) was performed 1-3 days before operation in 9 patients. Among the patients, there were 13 patients of mitral valve replacement (MVR), 7 patients of aortic valve replacement (AVR), 4 patients of tricuspid valve replacement (TVR), and 7 patients of double valve replacement (DVR). At the same time, all patients underwent ventricular or atrial volume reduction operation, including 19 patients of left atrial partial excision or plication, 7 patients of partial left ventricular excision, 5 patients of left atrial and left ventricular volume reduction operation, 21 patients of partial right atrial excision, and 3 patients of partial right ventricular excision. Besides, there were 5 patients of De Vega plasty, 14 patients of annuloplasty and3 patients of coronary artery bypass grafting (CABG). The echocardiogram was used to observe the change of heart function, atrium and ventricular in patients on postoperative and follow -up period. Results After surgery, one patient died of low cardiac output syndrome, and one other patient gave -up because of incision and mediastinum infection after reoperation for hemorrhage. Twentynine patients were followed -up for 3 to 12 months with 1 case lost. During the follow- -up, 3 patients died, of whom 2 died of deterioration of heart function and 1 died of sudden stroke. In the 12th month during the follow -up, heart function of all other 25 patients showed obvious improvements with 12 classⅠ, 7 classⅡ, 3 classⅢ and 3 classⅣ heart function according to NYHA classification. At the end of the follow -up, ejection fraction (5400%±800% vs. 2500%±300%) and cardiac index [3.30±0.50 L/(min·m2) vs. 1.10±0.30 L/(min·m2)] were significantly higher than those before operation (P<0.05), whereas left ventricular end diastolic diameter (5200±1000 mm vs. 9500±1200 mm) and left atrial diameter (3900±800 mm vs. 7000±1200 mm) both decreased significantly than those before operation (P<0.05). Conclusion Cardiac remodeling operation for endstage cardiac valve disease after active adjustment and preparation can achieve similar results to operation for severe valve diseases, providing a new choice for endstage heart disease.

    Release date:2016-08-30 05:56 Export PDF Favorites Scan
  • Effects of Ischemic Preconditioning on Myocardial Preservation in Patients Undergoing Cardiac Valve Replacement

    Objective To investigate whether single cycle ischemic preconditioning (IP) improves the myocardial preservation in patients undergoing cardiac valve replacement. Methods From August 2002 to April 2006, 85 patients who had chronic heart valve disease and required cardiac valve replacement were randomly divided into two groups. IP group, 47 allocated to receive IP and arrested with 4 C St. Thomas' Hospital cardioplegic solution during cardiopulmonary bypass(CPB), preconditioning was accomplished by using single cycle of 2 minutes occlusion of aorta followed by 3 minutes of reperfusion before cross-clamping. Control group, 38 allocated to receive 4 C St. Thomas' Hospital cardioplegic solution alone. Myocardial protective effects were assessed by determinations of creatinine kinase-MB isoenzyme (CK-MB) and cardiac troponin I(cTnI), ST-T changes, ventricular arrhythmias and other clinical data in ICU. Results Serum CK-MB and cTnI concentrations were increased postoperatively in two groups. At 24, 48 and 72h after operation, values of CK-MB in IP group was significantly lower than that in control group (P〈0.05), cTnI at 24 and 48h after operation also less in IP group (P〈0.05). The duration for patients needed for antiarrhythmic drugs in IP group was lower than that in control group (P〈0.05). Compared with control group, fewer inotropic drugs were used in IP group. As a result, ICU stay time in IP group was shorter than that in control group (P〈0.05). Conclusion IP enhances the myocardial protective effect when it was used with hypothermic hyper kalemic cardioplegic solution in patients undergoing cardiac valve replacement, IP significantly reduces the postoperative increase of CK-MB, cTnI and plessens the severity of postoperative ventricular arrhythmias.

    Release date:2016-08-30 06:23 Export PDF Favorites Scan
  • Cardiac Valve Operation in Children

    Objective To report the experiences of cardiac valve operation in children. Methods Cardiac valve operations were performed in 87 children who were 58 male and 19 female between age of 4 to 14 years (mean 10.2 years). Of the 87 patients, 36 underwent mitral valve replacement, 13 aortic valve replacement, 6 mitral and aortic valve replacement, 13 aortic valvuloplasty, and 19 mitral valvuloplasty. Associated cardiac lesions were simultaneously managed. Results Postoperative complications included low car...

    Release date:2016-08-30 06:35 Export PDF Favorites Scan
  • Validation of European System for Cardiac Operative Risk Evaluation in Heart Valve Surgery of Uyghur Patients and Han Nationality Patients

    ObjectiveTo assess the accuracy of European System for Cardiac Operative Risk Evaluation (EuroSCORE) model in predicting the in-hospital mortality of Uyghur patients and Han nationality patients undergoing heart valve surgery. MethodsClinical data of 361 consecutive patients who underwent heart valve surgery at our center from September 2012 to December 2013 were collected, including 209 Uyghur patients and 152 Han nationality patients. According to the score for additive and logistic EuroSCORE models, the patients were divided into 3 subgroups including a low risk subgroup, a moderate risk subgroup, and a high risk subgroup. The actual and predicted mortality of each risk subgroup were studied and compared. Calibration of the EuroSCORE model was assessed by the test of goodness of fit, discrimination was tested by calculating the area under the receiver operating characteristic (ROC) curve. ResultsThe actual mortality was 8.03% for overall patients, 6.70% for Uyghur patients,and 9.87% for Han nationality patients. The predicted mortality by additive EuroSCORE and logistic EuroSCORE for Uyghur patients were 4.03% and 3.37%,for Han nationality patients were 4.43% and 3.77%, significantly lower than actual mortality (P<0.01). The area under the ROC curve of additive EuroSCORE and logistic EuroSCORE for overall patients were 0.606 and 0.598, for Han nationality patients were 0.574 and 0.553,and for Uyghur patients were 0.609 and 0.610. ConclusionThe additive and logistic EuroSCORE are unable to predict the in-hospital mortality accurately for Uyghur and Han nationality patients undergoing heart valve surgery. Clinical use of these model should be considered cautiously.

    Release date: Export PDF Favorites Scan
  • Comparative Study of Efficacy Between 6-Epsilon-aminocaproic Acid and Aprotinin on Reducing Bleeding after Cardiac Valve Replacement

    Objective To compare the efficacy of 6-epsilon-aminocaproic acid (EACA) with aprotinin on reducing postoperative bleeding in cardiac valve replacement procedures, and to investigate its influence on the possible thromboembolism and the renal function. Methods Seventy-nine patients who underwent cardiac valve replacement were randomly divided into two groups: EACA group (n = 39) and aprotinin group (n = 40), which were given EACA and aprotinin separately in operations. The volumes of drainage to body surface area (BSA), blood transfusion were recorded during 24 h after operations. The concentrations of serum D-dimer and α2-antiplasmin (a2- AP) were measured before, during operation and at 72h post-operatively. The serum creatinine levels before operation and at the 72 h after operation were also measured. Results The volume ratio of drainage to BSA in EACA group was significantly higher than that in the aprotinin group at 24 h after operation (P = 0. 019). However, there was no significant difference in the volumes of blood transfusion between two groups (P〉0. 05). Also no statistical difference in the concentrations of D-dimer and a2-AP were found between two groups whether preoperatively or at 72h post-operatively (P= 0. 960,0. 485), D-dimer and a2-AP of the aprotinin group were higher than those in the EACA group after aortic off-clamping (P = 0. 001,0. 000). There was no statistically difference of △CrCl72 in both groups (P〉0. 05). No patient with thrombosis or thromboembolism was detected in two groups.Conclusion Although the efficacy of EACA in reducing postoperative bleeding in cardiac valve replacement can not compare favorably with that of aprotinin, the blood transfusion volume would not increase when EACA is used introoperatively. Proper usage of EACA will not cause thrombosis and renal damage.

    Release date:2016-08-30 06:22 Export PDF Favorites Scan
  • The Effective Orifice Area and Haemodynamics of 19mm St. Jude Regent Valve——An Early in Vivo Study

    Abstract: Objective To investigate the in vivo effective orifice area (EOA) and whether prosthesispatient mismatch (PPM) is going to happen after 19mm St.Jude Regent valves replacement were performed. Methods Twentythree patients with valvular heart diseases were divided into 2 groups according to aortic annular diameter. 19mm St. Jude Regent valves were replaced in aortic valve place (Regent valve group), and 21mm other doubleleaflet mechanical valves were replaced in aortic place (other valves group). All of the operations were accomplished under cardiopulmonary bypass in West China Hospital. All of the patients were followed up in 3 to 6 months after their surgery processes. Color Doppler echocardiography was used to measure the hemodynamic parameters in their followup. Then left ventricular mass (LV mass), EOA and effective orifice area index (EOAI) etc. were calculated and compared by using SPSS 12.0. Results No cardiac episodes were detected during the perioperative period and 36 months after operation. LVmass reduced in 36 months after operation in both groups. No statistical significance of EOA, EOAI and LVmass reduction were detected between the two groups. Conclusions (1)The EOA and in vivo hemodynamic effects of 19mm Regent valve are similar to 21mm other double leaflet mechanical valve. (2)It is safe to use 19mm Regent valve in those patients whose aortic annular diameter are small and need double valve replacement. Using 19mm Regent valve will not cause short time cardiac episodes and PPM. (3)More further works should be done to make sure what is the standard of PPM in Chinese people, such as enlarging the patients number and prolonging the followup time. (4) Further clinical and followup works should be done to make St.Jude Regent valve’s feature out.

    Release date:2016-08-30 06:16 Export PDF Favorites Scan
  • A wearable six-minute walk-based system to predict postoperative pulmonary complications after cardiac valve surgery: an exploratory study

    In recent years, wearable devices have seen a booming development, and the integration of wearable devices with clinical settings is an important direction in the development of wearable devices. The purpose of this study is to establish a prediction model for postoperative pulmonary complications (PPCs) by continuously monitoring respiratory physiological parameters of cardiac valve surgery patients during the preoperative 6-Minute Walk Test (6MWT) with a wearable device. By enrolling 53 patients with cardiac valve diseases in the Department of Cardiovascular Surgery, West China Hospital, Sichuan University, the grouping was based on the presence or absence of PPCs in the postoperative period. The 6MWT continuous respiratory physiological parameters collected by the SensEcho wearable device were analyzed, and the group differences in respiratory parameters and oxygen saturation parameters were calculated, and a prediction model was constructed. The results showed that continuous monitoring of respiratory physiological parameters in 6MWT using a wearable device had a better predictive trend for PPCs in cardiac valve surgery patients, providing a novel reference model for integrating wearable devices with the clinic.

    Release date:2023-12-21 03:53 Export PDF Favorites Scan
  • Effects of Tight Blood Glucose Control on the Shortterm Prognosis of the Patients after Heart Valve Replacement

    Objective To investigate the effects of tight blood glucose control on the shortterm prognosis of the patients after heart valve replacement, in order to improve treatment effectiveness and lower postoperative complications. Methods A total of 240 patients including 150 males and 90 females underwent mitral valve replacement or mitral and aortic valve replacement were enrolled in this study from January 2007 to December 2008 at the cardiac surgery department of Renmin hospital of Wuhan university. The age of these patients ranged from 19 to 65 years old with an average age of 53.33 years. According to insulin administration time and blood glucose control level, they were randomly separated into two groups. In the experimental group, there were 121 patients who received continuous insulin infusion to maintain postoperative glucose level between 4.4 and 6.1 mmol/L, while 119 patients in the control group received insulin infusion when their glucose level went higher than 11.1 mmol/L to control the level between 6.1 and 11.1 mmol/L. Then the postoperative wound infection, malignant arrhythmia rate, the assisted ventilation time, intensive care unit(ICU) stay time and count of neutrophils were compared and analyzed. Results There was no hospitalized death in both groups. The rate of wound infection(3.31% vs.10.08%, χ2=4.430,P=0.035), the assisted ventilation time(9.02±2.73 h vs. 10.01±3.58 h, t=2.280,P=0.024), time for count of leukocytes to decrease to the normal level(11.04±3.16 d vs. 12.05±3.76 d, t=2.168,P=0.031), average hospitalization time(13.49±3.81 d vs. 14.51±4.02 d,t=2.017,P=0.045), and count of neutrophils on the third day(0.82±0.04 vs. 0.84±0.05, t=2.644,P=0.009) in the experimental group were significantly lower or shorter than those in the control group. But there was no significant difference between both groups in ICU stay time and the rate of malignant arrhythmia. Conclusion Tight blood glucose control can lower the rate of postoperative wound infection, shorten the assisted ventilation time and hospitalization time, and reduce the usage of antibiotics in patients after heart valve replacement. Accordingly, it can enhance the curative effect, reduce overall medical expenses, and improve prognosis.

    Release date:2016-08-30 05:59 Export PDF Favorites Scan
3 pages Previous 1 2 3 Next

Format

Content