Objective To evaluate the methodological quality and reporting quality of clinical guidelines and consensus on central venous catheters. Methods The PubMed, EMbase, Web of Science, CBM, WanFang Data, CNKI databases and Guidelines International Network, National Institute for Health and Clinical Excellence, National Guideline Clearinghouse, Medive.cn websites were searched to collect clinical guidelines and consensus related to central venous catheters. The retrieval time was from the establishment of the database to October 2022. Two researchers independently screened the literature, extracted data and used evaluation tools AGREE Ⅱ and RIGHT to evaluate the quality of the included studies. Results A total of 34 central venous catheter guidelines and consensus were included. The average score for each field of AGREE II was 53.73% for scope and purpose, 39.26% for participants, 39.57% for rigor, 46.76% for clarity, 30.23% for application and 49.18% for editorial independence. Items 1a, 1b, 3, and 4 (100.00%) had the highest reporting rate in the RIGHT evaluation items, followed by items 19a (97.05%), 2/19b (94.11%), 20 (91.17%), 7b/11a (88.23%), and 7a (85.29%). The reporting rate of the remaining items was below 60%. Subgroup analysis results showed that the average score and RIGHT score of the guidance class in the four fields of AGREE Ⅱ (rigor, clarity, application and editorial independence) were higher than those of the consensus class. Guidelines and consensus formulated based on evidence-based medicine methods were higher than those formulated based on expert opinions or reviews in the three fields of AGREE II (rigor, application and editorial independence). The average scores of foreign guidelines and consensus in 6 fields and RIGHT scores of AGREE Ⅱ were higher than those of domestic guidelines and consensus. Conclusion The AGREE Ⅱ of 6 fields average score and RIGHT score in foreign guidelines are higher than those in domestic guidelines.
Objective To explore the risk factors of catheter-associated bloodstream infections ( CRBSI) in intensive care unit ( ICU) of primary hospital. Methods A total of 623 patients with central venous catheters were recruited in the study. 60 of themsuffered fromCRBSI served as an observation group and other 563 cases without CRBSI served as control. Univariate analysis was used to scan possible risk factors. Then logistic regression analysis was used to exclude the confounding factors. Results The overall incidence rate of CRBSI was 9. 63% ( 60 /623) . There were significant differences in APACHE score, type of catheter, location of catheter, duration of central venous catheter, intravenous nutrition, use of steroid, times of intubation, urgent intubations, nutritional status, diabetes, and MODS between the two groups. Logistic regression analysis revealed that higher APACHE score, double-lumen catheter, femoral vein catheter, catheter indwelling more than two weeks, intravenous nutrition, intubation more than 2 times, and emergency intubation were risk factors of CRBSI. Conclusions Higher APACHE score, double-lumen catheter, femoral vein catheter, catheter indwelling more than two weeks, intravenous nutrition, intubation more than 2 times, and emergency intubation were major risk factors of CRBSI in ICU of primary hospital.
ObjectiveTo explore the influence of three central venous catheter biomedical materials (polyurethane, silicone, and polyvinyl chloride) on the proliferation, apoptosis, and cell cycle of Xuanwei Lung Cancer-05 (XWLC-05) cells so as to provide the basis for clinical choice of central venous catheter. MethodsXWLC-05 cells were cultured and subcultured, and the cells at passage 3 were cultured with polyurethane, silicone, and polyvinyl chloride (1.0 cm × 1.0 cm in size), and only cells served as a control. At 24, 48, and 72 hours after cultured, MTT assay was used to detect the cellular proliferation and flow cytometry to detect the cell cycle and apoptosis. At 72 hours after cultured, inverted microscope was used to observe the cell growth. ResultsInverted microscope showed the cells grew well in control group, polyurethane group, and silicone group. In polyvinyl chloride group, the cells decreased, necrosed, and dissolved; residual adherent cells had morphologic deformity and decreased transmittance. At 24 and 48 hours, no significant difference in proliferation, apoptosis, and cell cycle was found among 4 groups (P gt; 0.05). At 72 hours, the proliferations of XWLC-05 cells in three material groups were significantly inhibited when compared with control group (P lt; 0.05), and the cells in polyvinyl chloride group had more significant proliferation inhibition than polyurethane group and silicone group (P lt; 0.05), but there was no signifcant difference in proliferation inhibition between polyurethane group and silicone group (P gt; 0.05). Compared with the control group, three material groups had significant impact on the rate of apoptosis and cell cycle: polyvinyl chloride group was the most remarkable, followed by silicone group, polyurethane group was minimum (P lt; 0.05). ConclusionPolyvinyl chloride can significantly impact the proliferation, apoptosis, and cell cycle of XWLC-05 cells; polyurethane has better biocompatibility than polyvinyl chloride and silicone
ObjectiveTo evaluate tip location of peripherally inserted central catheter (PICC) by using the carina as evaluation mark, so as to provide clinical references for blinding manipulation of PICC. MethodsA retrospective analysis about the effects of tip location of PICC by using the carina as evaluation mark on inpatients with malignant tumour was conducted in tumour centre of the West China Hospital from March 2013 to April 2014. Chest X radiography was applied to evaluate the tip location of PICC. Statistical analysis was performed using SPSS software (version 19.0) and the outcomes were presented by frequency and percentage. ResultsA total of 612 cases of blinding manipulation of PICC were evaluated, of which, 502 (82%) were located in the central venous and 110 (18%) were located in the noncentral venous. The numbers of those with the catheter tips located in the non-central venous were 38 in the right atrium, 33 in the internal jugular vein, 24 in the innominate vein, 8 in the axillary vein, and 7 in the subclavian vein, respectively. ConclusionThe effects of blinding manipulation of peripherally-inserted central catheter by using the carina as evaluation mark are relatively good. But it still needs to be improved.
Objective\ To investigate the clinical significance of measuring central venous pressure in patients after cardiac surgery.\ Methods\ Twenty four patients in postoperative cardiac surgery were randomly chosen, and investigated under three fettles:(1) The patients were sent into intensive care unit on mechanical ventilation; (2) They were all conscious and on mechanical ventilation 8 hours after operation; (3) 24 hours after operation, the patients were conscious with normal breathing.
ObjectiveTo evaluate the feasibility and safety of improving chest drainage procedure by applying postoperative chest drainage with central venous catheter for uniportal video-assisted thoracoscopic surgery (VATS) lobectomy in fast track recovery. MethodsBetween July 2016 and March 2018, a total of 150 patients who underwent uniportal VATS lobectomy by the same chief surgeon were recruited. All patients were randomly divided into two groups including a trial group and a control group. In the trial group, there were 44 males and 28 females with an average age of 47±11 years. Central venous catheter and 26F silicone rubber tuber were used and chest tube was removed when drainage volume less than 300 ml/d. Chest X ray was conducted three days after discharge from hospital and the central venous catheter was removed after thoracentesis. In the control group, there were 40 males and 29 females with an average ages of 52±13 years, 26 F silicone rubber tuber and chest tube were removed when drainage volume less than 100 ml/d. The clinical effectiveness was compared between the two groups. ResultsNo statistically significant difference was observed between the trial group and the control group in the date of preoperative general information, the occurrence of postoperative complications and the visual analogue score on Day1 after the operation. However, the visual analogue score, intubation time, post-operative length of stay, the frequency of using tramadol were all significantly shorter or lower in the trial group when compared with the control group (P<0.05). Seven patients of the trial group suffered moderate pleural effusion after intubation, which was significantly more than that of the control group (P<0.05). Six patients recovered after thoracentes through central venous catheter. The average amount of pleural effusions before removing the central venous catheter was 74.8 ml. ConclusionThe use of central venous catheter and 26 F silicone rubber tuber after uniportal VATS lobectomy is safe and feasible for the early removal of chest tube. It is beneficial to fast track recovery.
ObjectiveTo investigate the effect of suprapubic catheterization(SPC) by using central venous catheter (CVC) on the perioperative complications in middle and low rectal cancer surgery. MethodsThe clinical data of 141 patients with middle and low rectal cancer underwent operation in Shengjing Hospital of China Medical University from April 2012 to January 2015 were collected. There were 65 patients performed SPC by using CVC, 76 patients performed routine transurethral catheterization(TUC). The incidences of bacteriuria and urinary retention, recatheterization rate, duration of catheterization, and catheter-related pain were analyzed and compared between these two groups. Results①Compared with the TUC, the SPC by using CVC could significantly reduce the incidence of bacteriuria(P=0.002), espe-cially in female(P=0.006), ≥60 years old(P=0.001), low rectal cancer(P=0.003), open surgery(P=0.018), Miles(P=0.016), and Dixon(P=0.032).②There was no significant difference in the incidence of urinary retention(P=0.464) between the SPC by using CVC and the TUC.③Compared with the TUC, the SPC by using CVC could significantly reduce the inci-dence of recatheterization rate(P=0.001), especially in the patients with male(P=0.016), ≥60 years old(P=0.008), low rectal cancer(P=0.019), laparoscopic surgery(P=0.013), and Miles(P=0.037).④Compared with the TUC, the point of catheter-related pain was significantly lower in the SPC by using CVC(P=0.001), no matter males(P=0.005) or females(P=0.010), aged 60 years and older(P=0.023) or younger(P=0.034), middle rectal cancer(P=0.017) or low rectal cancer(P=0.046), open surgery(P=0.033) or laparoscopic surgery(P=0.021), Dixon(P=0.019) or Miles(P=0.035).⑤The duration of catheterization was similar between the SPC by using CVC and the TUC(P=0.597). ConclusionSPC by using CVC is a safer, more effective and more acceptable method of bladder drainage in middle and low rectal cancer surgery as compared with routine TUC.
ObjectiveTo investigate the diagnostic value of simultaneous culture of central venous catheter (CVC) blood and peripheral blood for catheter-related bloodstream infections (CRBSI). MethodsNon-septic patients who were treated with CVC for 1 to 7 days were enrolled from February 2011 to February 2015 in the First Hospital of Wuhan City. Blood were collected from both peripheral vein and CVC for bacterial culture once a day. The CVCs were removed from patients who got CRBSI from the first to sixth day and who did not by the end of the seventh day for semi-quantitative catheter culture, quantitative catheter culture, CVC culture and catheter exit-site pus culture. The diagnosis of CRBSI were based on 4 methods as follows:A, both peripheral and CVC blood were positive and the time of CVC blood positive were 2 hours earlier than peripheral blood; B, the colonies of semi-quantitative catheter cultures were ≥15 CFU and the microorganisms in both CVC and peripheral blood were the same; C, the colonies ratio of CVC and peripheral blood cultures were ≥5:1; D, the microorganisms in both the peripheral blood and catheter exit-site pus were the same. The diagnostic value of the four methods was compared. ResultsA total of 1 086 patients were finally included. From 1 to 7 days, 64 patients were peripheral blood positive, 79 were CVC blood positive. The patients diagnosed as CRBSI using A, B, C, and D methods were 58, 55, 51, and 36, respectively. Sixty patients were diagnosed as CRBSI based on the clinical and laboratory methods. For the number of patients diagnosed with CRBSI, there was no significant difference between A and B (P>0.05), as well as A and C (P>0.05), however, significant difference was found between A and D (P<0.05). In the diagnostic value of CRBSI, A is similar to B (sensitivity:93.33% vs. 91.67%, specificity:99.81% vs. 100%, Youden index:0.93 vs. 0.92). A, B and C had almost similar specificity (all >99%), however, A had higher sensitivity (93.33% vs. 76.67%, 58.33%) and Youden index (0.93 vs. 0.76, 0.58). ConclusionSimultaneous culture of CVC blood and peripheral blood has a good diagnostic value for CRBSI.
Objective To explore the relationship between central venous-to-arterial carbon dioxide difference/arterial-to-venous oxygen difference ration [P(cv-a)CO2/C(a-cv)O2] and arterial lactate in patients with sepsis. Methods A retrospective analysis was carried on 36 septic patients who were admitted to the Intensive Care Unit of Nanjng Drum-tower Hospital affiliated to Medical School of Nanjing University from May 2013 to November 2013. Cardiac index was measured by transpulmonary thermodilution. At the same time, femoral artery and central venous blood were collected to measure the value of arterial lactate and central venous oxygen saturation (ScvO2) by blood gas analysis and calculate central venous-to-arterial carbon dioxide difference [P(cv-a)CO2], arterial-to-venous oxygen difference [C(a-cv)O2], and their ration [P(cv-a)CO2/C(a-cv)O2], oxygen delivery (DO2) and oxygen consumption (VO2). The subjects were divided intoahyperlactatemia group (≥2 mmol/L) andanormal lactate group (< 2 mmol/L) according to arterial lactate value. P(cv-a)CO2/C(a-cv)O2 and other oxygen metabolism parameters were compared between two groups. Receiver operating characteristic (ROC) curve was used to evaluate the accuracy of P(cv-a)CO2/C(a-cv)O2 and other parameters for diagnosis of hyperlactatemia. Results A total of 36 patients with 119 data were collected. Compared with the normal lactate group, P(cv-a)CO2/C(a-cv)O2 was significantly higher [(1.38±0.76)mm Hg/mL vs. (2.31±1.01) mm Hg/mL, P < 0.01], ScvO2, DO2 and VO2 were significantly lower in the hyperlactatemia group [ScvO2: (74.26±9.13)% vs. (70.29±9.72)%; DO2: (505.52±208.39) mL/(min·m2) vs. (429.98±173.63) mL/(min·m2)]; VO2: (129.01±54.94) mL/(min·m2) vs. (109.99±38.79) mL/(min·m2), P < 0.05]. P(cv-a)CO2 had no significant difference between two groups [(5.76±3.70) mm Hg vs. (6.59±3.70) mm Hg, P > 0.05]. P(cv-a)CO2/C(a-cv)O2 was positively correlated with lactate (r=0.646, P < 0.01). ScvO2 was negatively correlated with lactate (r=-0.277, P < 0.01). DO2 and VO2 had no significant correlation with lactate (P > 0.05). The area under ROC curve (AUC) of P(cv-a)CO2 /C(a-cv)O2 for diagnosis of hyperlactatemia was 0.820, with 95% confidence interval (95%CI) of 0.715 - 0.925(P < 0.001); The AUC of ScvO2 was 0.622, with 95%CI of 0.520 - 0.724(P=0.025). Conclusion Compared with the traditional oxygen metabolism parameters, P(cv-a)CO2/C(a-cv)O2 can accurately diagnose hyperlactatemia, and isareliable parameter to reflect oxygen metabolism in patients with sepsis.
ObjectiveTo investigate the influence of misplaced subclavian vein (SCV) catheter into the ipsilateral internal jugular vein (IJV) on transpulmonary thermodilution (TPTD) measurements and explore the possible mechanisms preliminarily.MethodsIn this prospective study, 408 patients in whom an SCV catheterization was indicated for TPTD monitoring were enrolled. A first set of TPTD measurements was collected at baseline in all patients (group 1, SCV catheters were correctly placed; group 2, SCV catheters were misplaced into the ipsilateral IJV). The parameters included mean transit time (MTt), downslope time (DSt), cardiac index (CI), global end-diastolic volume index (GEDVI) and extra-vascular lung water index (EVLWI). A second set of TPTD measurements was performed only in those with catheter misplacement immediately after the misplaced SCV catheters being corrected (Group 3). The differences in MTt, DSt, GEDVI and EVLWI between group 2 and 3 were recorded as ΔMTt, ΔDSt, ΔGEDVI and ΔEVLWI, respectively.ResultsGEDVI and EVLWI were significantly higher (all P<0.001) in group 2 than those in group 1, while CI was not significantly different (P>0.05) between these two groups. Multivariate logistic regression identified PaO2/FiO2 [adjusted odds ratio (OR) 1.492/10 mm Hg; 95% confidence interval (CI), 1.180 - 1.884; P<0.001], GEDVI (OR=1.307/10 mL/m2, 95% CI 1.131 - 1.511; P<0.001) and EVLWI (OR=3.05; 95%CI 1.593 - 5.840; P<0.001) as the 3 independent factors associated with the misplacement of SCV catheter into the ipsilateral IJV. In group 2, GEDVI [(1041±122)mL/m2 vs. (790±102)mL/m2, P<0.001], EVLWI [(20.3±4.0)mL/kg vs. (10.3±2.3)mL/kg, P<0.001], CI [(3.6±1.2)L·min–1·m–2 vs. (2.9±1.0)L·min–1·m–2, P<0.001], MTt [(38.2±13.3)s vs. (30.8±9.4)s, P<0.001] and DSt [(18.9±7.2)s vs. (13.2±4.9)s, P<0.001)] were significantly higher than those in Group 3. Multiple regression analysis demonstrated that ΔEVLWI (R2=0.86, P<0.001) was negatively correlated with ΔMTt (coefficient±SE, –0.52±0.12; P<0.001) and positively correlated with ΔDSt (coefficient±SE, 1.45±0.17; P<0.001).ConclusionsDuring TPTD measurements, indicator injection through an SCV catheter misplaced into the ipsilateral IJV results in an overestimation of CI, GEDVI and EVLWI. The increase in DSt might be a key factor in explaining the overestimation of EVLWI in patients with misplaced SCV catheters. Given that the accurate measurements of GEDVI and EVLWI are of utmost importance for guiding resuscitation and decision-making regarding fluids administration, immediate repositioning is required if a misplacement is suspected and confirmed by the chest X-ray.