Objective To analyze the short-term effectiveness and safety of personalized three-dimensional (3D) printed customized prostheses in severe Paprosky type Ⅲ acetabular bone defects. Methods A retrospective analysis was conducted on 8 patients with severe Paprosky type Ⅲ acetabular bone defects and met the selection criteria between January 2023 and June 2024. There were 3 males and 5 females, with an average age of 64.6 years ranged from 56 to 73 years. All primary replacement prostheses were non-cemented, including 1 ceramic-ceramic interface, 1 ceramic-polyethylene interface, and 6 metal-polyethylene interfaces. The time from the primary replacement to the revision was 4 days to 18 years. The reasons for revision were aseptic loosening in 5 cases, revision after exclusion in 2 cases, and repeated dislocation in 1 case. The preoperative Harris score was 39.5±3.7 and the visual analogue scale (VAS) score was 7.1±0.8. The operation time, intraoperative blood loss, hospital stay, and complications were recorded. The hip function was evaluated by Harris score, and the degree of pain was evaluated by VAS score. The acetabular cup abduction angle, anteversion angle, rotational center height, greater trochanter height, and femoral offset were measured on X-ray film. Results The operation time was 95-223 minutes, with an average of 151.13 minutes. The intraoperative blood loss was 600-3 500 mL, with an average of 1 250.00 mL. The hospital stay was 13-20 days, with an average of 16.88 days. All 8 patients were followed up 2-12 months, with an average of 6.4 months. One patient had poor wound healing after operation, which healed well after active symptomatic treatment. One patient had lower limb intermuscular vein thrombosis, but no thrombosis was found at last follow-up. No serious complications such as aseptic loosening, infection, dislocation, and periprosthetic fracture occurred during the follow-up. At last follow-up, the Harris score was 72.0±6.2 and the VAS score was 1.8±0.7, which were significantly different from those before operation (t=−12.011, P<0.001; t=16.595, P<0.001). On the second day after operation, the acetabular cup abduction angle ranged from 40° to 49°, with an average of 44.18°, and the acetabular cup anteversion angle ranged from 19° to 26°, with an average of 21.36°, which were within the “Lewinneck safety zone”. There was no significant difference in the rotational center height, greater trochanter height, and femoral offset between the healthy side and the affected side (P>0.05). ConclusionThe use of personalized 3D printed customized prostheses for the reconstruction of severe Paprosky type Ⅲ acetabular bone defects can alleviate pain and enhances hip joint function, and have good postoperative prosthesis position, without serious complications and have good safety.
ObjectiveTo explore the effectiveness of a new point contact pedicle navigation template (referred to as “new navigation template” for simplicity) in assisting screw implantation in scoliosis correction surgery. MethodsTwenty-five patients with scoliosis, who met the selection criteria between February 2020 and February 2023, were selected as the trial group. During the scoliosis correction surgery, the three-dimensional printed new navigation template was used to assist in screw implantation. Fifty patients who had undergone screw implantation with traditional free-hand implantation technique between February 2019 and February 2023 were matched according to the inclusion and exclusion criteria as the control group. There was no significant difference between the two groups (P>0.05) in terms of gender, age, disease duration, Cobb angle on the coronal plane of the main curve, Cobb angle at the Bending position of the main curve, the position of the apical vertebrae of the main curve, and the number of vertebrae with the pedicle diameter lower than 50%/75% of the national average, and the number of patients whose apical vertebrae rotation exceeded 40°. The number of fused vertebrae, the number of pedicle screws, the time of pedicle screw implantation, implant bleeding, fluoroscopy frequency, and manual diversion frequency were compared between the two groups. The occurrence of implant complications was observed. Based on the X-ray films at 2 weeks after operation, the pedicle screw grading was recorded, the accuracy of the implant and the main curvature correction rate were calculated. ResultsBoth groups successfully completed the surgeries. Among them, the trial group implanted 267 screws and fused 177 vertebrae; the control group implanted 523 screws and fused 358 vertebrae. There was no significant difference between the two groups (P>0.05) in terms of the number of fused vertebrae, the number of pedicle screws, the pedicle screw grading and accuracy, and the main curvature correction rate. However, the time of pedicle screw implantation, implant bleeding, fluoroscopy frequency, and manual diversion frequency were significantly lower in trial group than in control group (P<0.05). There was no complications related to screws implantation during or after operation in the two groups. ConclusionThe new navigation template is suitable for all kinds of deformed vertebral lamina and articular process, which not only improves the accuracy of screw implantation, but also reduces the difficulty of operation, shortens the operation time, and reduces intraoperative bleeding.
ObjectiveTo solve the fixation problem between ligament grafts and host bones in ligament reconstruction surgery by using ligament-bone composite scaffolds to repair the ligaments, to explore the fabrication method for ligament-bone composite scaffolds based on three-dimensional (3-D) printing technique, and to investigate their mechanical and biological properties in animal experiments. MethodsThe model of bone scaffolds was designed using CAD software, and the corresponding negative mould was created by boolean operation. 3-D printing techinique was employed to fabricate resin mold. Ceramic bone scaffolds were obtained by casting the ceramic slurry in the resin mould and sintering the dried ceramics-resin composites. Ligament scaffolds were obtained by weaving degummed silk fibers, and then assembled with bone scaffolds and bone anchors. The resultant ligament-bone composite scaffolds were implanted into 10 porcine left anterior cruciate ligament rupture models at the age of 4 months. Mechanical testing and histological examination were performed at 3 months postoperatively, and natural anterior cruciate ligaments of the right sides served as control. ResultsBiomechanical testing showed that the natural anterior cruciate ligament of control group can withstand maximum tensile force of (1 384±181) N and dynamic creep of (0.74±0.21) mm, while the regenerated ligament-bone scaffolds of experimental group can withstand maximum tensile force of (370±103) N and dynamic creep of (1.48±0.49) mm, showing significant differences (t=11.617,P=0.000; t=-2.991,P=0.020). In experimental group, histological examination showed that new bone formed in bone scaffolds. A hierarchical transition structure regenerated between ligament-bone scaffolds and the host bones, which was similar to the structural organizations of natural ligament-bone interface. ConclusionLigament-bone composite scaffolds based on 3-D printing technique facilitates the regeneration of biomimetic ligament-bone interface. It is expected to achieve physical fixation between ligament grafts and host bone.
Objective To investigate the effectiveness of sacroiliac screw implantation assisted by three-dimensional (3D) printed faceted honeycomb guide plate in the treatment of posterior pelvic ring fracture. Methods The clinical data of 40 patients with posterior pelvic ring fractures treated with sacroiliac screw implantation between December 2019 and December 2022 were retrospectively analyzed. Among them, 18 cases were treated with sacroiliac screws fixation assisted by 3D printed faceted honeycomb guide plate (guide plate group), and 22 cases were treated with sacroiliac screws percutaneously fixation under fluoroscopy (conventional group). There was no significant difference in baseline data (P>0.05) such as gender, age, time from injury to operation, and Dennis classification between the two groups. The implantation time, frequency of C-arm X-ray fluoroscopy, frequency of guide pin adjustment of each sacroiliac screw, and postoperative complications and bone healing were recorded. Majeed score was used to evaluate the functional recovery at 6 months after operation, and CT was used to observe whether the screw penetrated the bone cortex. The deviation between the virtual position and the actual position of the screw tip, the sacral foramen, and the screw entry point was measured on the sagittal CT images of the guide plate group. Results The number of screws implanted in S1 and S2 vertebral bodies was 14 and 16 respectively in the guide plate group, and 17 and 18 respectively in the conventional group. The implantation time of each sacroiliac screw, the frequency of C-arm X-ray fluoroscopy, and the frequency of guide pin adjustment in S1, S2, and all vertebrae in the guide plate group were significantly less than those in the conventional group (P<0.05). Patients in both groups were followed up 8-48 months, with an average of 19.7 months. There was no incision infection, screw displacement, or internal fixation loosening in both groups. Callus growth was observed in all patients at 12 weeks after operation, and bone healing was achieved in all patients. The healing time ranged from 12 to 24 weeks, with an average of 15.7 weeks. No sacroiliac screw penetrated the bone cortex in the guide plate group; 2 patients in the conventional group had sacroiliac screws penetrating the bone cortex without damaging blood vessels or nerves. In the guide plate group, the deviation between the virtual position and the actual position of the screw tip, the sacral foramen, and the screw entry point were (2.91±1.01), (2.10±0.74), and (1.67±0.70) mm, respectively, with an average deviation of (2.19±1.22) mm. There was no significant difference in Majeed function evaluation between the two groups at 6 months after operation (P>0.05). Conclusion The application of 3D printed faceted honeycomb guide plate in sacroiliac screw implantation for posterior pelvic ring fracture can shorten the screw implantation time, reduce the frequency of fluoroscopy and guide pin adjustment, and reduce the risk of screw penetration through the bone cortex.
ObjectiveTo investigate the mid-term effectiveness of three‐dimensional (3D) printed osteotomy guide plate and personalized prosthesis in knee‐preserving tumor resection. Methods The clinical data of 12 patients who underwent knee‐preserving tumor resection and reconstruction with 3D printed osteotomy guide plate and personalized prosthesis between September 2016 and October 2018 were retrospectively analyzed. There were 7 males and 5 females. The age ranged from 7 to 59 years, with a median of 44.5 years. There were 11 cases of osteosarcoma and 1 case of fibrosarcoma, all of which were Enneking grade ⅡB. The distance from the tumor to the joint surface was 5.5-8.2 cm, with an average of 6.94 cm. Incision healing, tumor recurrence, periprosthetic fracture, and aseptic loosening were observed after operation. The Musculoskeletal Tumor Society (MSTS) scoring system was used to evaluate the function of the patients, and the knee flexion range of motion was measured. ResultsThe 12 patients were followed up 41-66 months, with an average of 54.5 months. The length of osteotomy ranged from 14 to 26 cm, with an average of 22.08 cm. Except for 2 patients with superficial infection of incision tissue, no deep infection involving the prosthesis occurred, no patient underwent revision surgery because of prosthesis infection. During the follow-up, local recurrence occurred in 2 cases and distant metastasis occurred in 3 cases. The overall disease-free survival rate was 58.3%. Two patients died of lung metastasis, and the overall survival rate was 83.3%. One patient underwent amputation due to local recurrence, and 1 patient underwent total knee arthroplasty due to prosthesis rupture. No aseptic loosening of the prosthesis and periprosthetic fracture occurred during the follow-up, and the overall prosthesis survival rate was 83.3%. At last follow-up, 10 patients obtained satisfactory knee flexion range of motion that ranged from 95° to 125°, with an average of 110°. Two children could not cooperate with early rehabilitation treatment due to pain, and the knee flexion range of motion was not ideal (50°, 75°). All patients achieved acceptable lower limb function with MSTS scores ranged from 26 to 30, with an average of 28. All patients walked without crutches. ConclusionThe treatment of malignant bone tumors around the knee joint with 3D printed osteotomy guide plate and personalized prosthesis can preserve the articular surface, obtain good limb function, reduce the risk of aseptic loosening of prosthesis, and achieve better mid-term effectiveness.
ObjectiveTo review the research progress of adipose-derived stem cells (ADSCs) compound with three dimensional (3D) printing scaffold in tissue engineering of fat, bone, cartilage, blood vessel, hepatocyte, and so on. MethodsThe recently published literature about ADSCs compound with 3D printing scaffold in tissue engineering at home and abroad was reviewed, analyzed, and summarized. ResultsA large number of basic researches showed that ADSCs could differentiate into a variety of tissues on 3D printing scaffold and involve in tissue repair and regeneration. But there is still a long way between the basic theory and the clinical practice at the early stages of development. ConclusionIt can effectively improve and restore the structure and function of the damaged tissue and organ to use ADSCs and 3D printing scaffold.
ObjectiveTo study the preparation and cytocompatibility of bone tissue engineering scaffolds by combining low temperature three dimensional (3D) printing and vacuum freeze-drying techniques. MethodsCollagen (COL)and silk fibroin (SF) were manufactured from fresh bovine tendon and silkworm silk. SolidWorks2014 was adopted to design bone tissue engineering scaffold models with the size of 9 mm×9 mm×3 mm and pore diameter of 500μm. According to the behavior of composite materials that low temperature 3D printing equipment required, COL, SF, and nano-hydroxyapatite (nHA)at a ratio of 9:3:2 and low temperature 3D printing in combination with vacuum freeze-drying techniques were accepted to build COL/SF/nHA composite scaffolds. Gross observation and scanning electron microscope (SEM) were applied to observe the morphology and surface structures of composite scaffolds. Meanwhile, compression displacement, compression stress, and elasticity modulus were measured by mechanics machine to analyze mechanical properties of composite scaffolds. The growth and proliferation of MC3T3-E1 cells were evaluated using SEM, inverted microscope, and MTT assay after cultured for 1, 7, 14, and 21 days on the composite scaffolds. The RT-PCR and Western blot techniques were adopted to detect the gene and protein expressions of COL I, alkaline phosphatase (ALP), and osteocalcin (OCN) in MC3T3-E1 cells after 21 days. ResultsCOL/SF/nHA composite scaffolds were successfully prepared by low temperature 3D printing technology and vacuum freeze-drying techniques; the SEM results showed that the bionic bone scaffolds were 3D polyporous structures with macropores and micropores. The mechanical performance showed that the elasticity modulus was (344.783 07±40.728 55) kPa; compression displacement was (0.958 41±0.000 84) mm; and compression stress was (0.062 15±0.007 15) MPa. The results of inverted microscope, SEM, and MTT method showed that a large number of cells adhered to the surface with full extension and good cells growth inside the macropores, which demonstrated a satisfactory proliferation rate of the MC3T3-E1 cells on the composite scaffolds. The RT-PCR and Western blot electrophoresis revealed gene expressions and protein synthesis of COL I, ALP, and OCN in MC3T3-E1 cells. ConclusionLow temperature 3D printing in combination with vacuum freeze-drying techniques could realize multi-aperture coexisted bionic bone tissue engineering scaffolds and control the microstructures of composite scaffolds precisely that possess good cytocompatibility. It was expected to be a bone defect repair material, which lays a foundation for further research of bone defect.