find Author "GAO Haoyu" 2 results
  • First robotic-assisted balloon-expandable transcatheter aortic valve implantation for severe aortic stenosis: A two-case report

    This study reports the first successful clinical application of a robotic-assisted system in transcatheter balloon-expandable aortic valve implantation using the Edwards SAPIEN 3 valve. Two male patients, aged 60 and 63 years, respectively, presented with severe aortic stenosis confirmed by echocardiography and computed tomography, showing significant valvular calcification and elevated transvalvular pressure gradients, meeting the indications for transcatheter aortic valve implantation (TAVI). Both procedures were performed via the right femoral artery using a robotic-assisted delivery and positioning system developed by Shanghai Surgerii Medical Technology Co., Ltd. The operator controlled the delivery system and valve positioning precisely through the console, while the assistant performed balloon expansion and valve deployment. Both procedures were completed successfully without intraoperative complications. The operative times were 75 minutes and 67 minutes, with fluoroscopy times of 16 minutes and 23 minutes, and radiation doses of 714 mGy and 971 mGy, respectively. Postoperative echocardiography demonstrated well-functioning prosthetic valves, with mean transvalvular pressure gradients of 3.9 mm Hg and 8 mm Hg, and none or trivial paravalvular leakage. No coronary obstruction, conduction disturbance, or vascular complications were observed.This report represents the world’s first clinical use of a robotic-assisted system for balloon-expandable TAVI. It confirms the feasibility and safety of robotic assistance in transcatheter valve delivery and positioning, offering a new approach to enhance procedural precision and stability, and providing valuable insights for the future development of intelligent, minimally invasive therapies for structural heart disease.

    Release date: Export PDF Favorites Scan
  • Advances in acute Stanford type A aortic dissection with organ malperfusion

    The treatment of acute Stanford type A aortic dissection has always been extremely challenging. Organ malperfusion syndrome is a common severe complication of acute aortic dissection, which can cause organ ischemia and internal environment disorder. Malperfusion increases early mortality, and impacts the long-term prognosis. In recent years, many scholars have done some studies on aortic dissection complicated with malperfusion. They explored the pathogenesis, proposed new classification, and innovated new treatment strategies. However, at present, the treatment strategies of acute Stanford type A aortic dissection complicated with organ malperfusion are different at different centers and consensus on its treatment is still lacking. Therefore, this review summarized the pathogenesis, classification, treatment strategy, and prognosis of acute Stanford type A aortic dissection complicated with malperfusion.

    Release date:2024-08-02 10:43 Export PDF Favorites Scan
1 pages Previous 1 Next

Format

Content