Objective To investigate the clinical feasibility of different types of the saphenous neuro-veno-fascial cutaneous flaps. Methods From June 1996 to October 2002, 18 cases of skin defects in the knee and the lower part of the limb were treated with proximally(4 cases) or distally(11 cases) based pedicles of saphenous neuro-venofascial cutaneous flap or crossleg flap (3 cases)according to the site of defects . The sizes of the flaps ranged from 4 cm×5 cm to 9 cm×20 cm. Results The flaps survived completely in 17 cases, distal 1/5 of the flap necrosed partially in 1 case because of vein drainage disturbance. The colour and texture of flaps were excellent, the appearance and function were satisfactory after a follow up of 6-24 months.Conclusion The saphenous neuro-veno-fascial cutaneous flap is an idea flap in repairing skin defects of the knee, the leg, the ankle and the foot because it is easy to be designed and dissected and it has reliable blood supply and preserved main artery. The relationship between the septal perforating branches of the tibial posteriorartery and survival size of flap need to be investigated further.
Objective To compare the condition of the structure and oxidative stress of great saphenous vein grafts between the patients with and without type 2 diabetes mellitus, and to study the mechanisms for providing the theory evidence ofthe protective way for great saphenous vein graft in patients with type 2 diabetes mellitus. Methods The segments of human great saphenous vein graft were collected from 36 patients undergoing coronary artery bypass graft surgery, who were divided into 2 groups, experimental group (17 patients with type 2 diabetes mellitus) and control group (19 patients without type 2 diabetes mell itus). There was no significant difference in age, gender, hypertension, serum creatinine, hyperl ipidemia, smoking, and the number of pathological coronary arteries between 2 groups (P gt; 0.05). Two cm distal great saphenous vein from each patient was obtained. The structure of great saphenous vein was observed by the microscope, and nicotinamide adenine dinucleotide phosphate (NADPH) oxidase enzymatic activity and superoxide anion level were quantified by lucigenin-enhanced chemilumi nescence. Results The NADPH oxidase activity and superoxide anion levels were significantly higher in experimental group [(308.8 ± 33.7) counts/μg and (1 951.71 ± 355.2) counts/(min.mg)] than in control group [(202.7 ± 29.5) counts/μg and (1 230.73 ± 340.5) counts/(min.mg)] (P lt; 0.05). HE staining showed the damage of ultrastructure of great saphenous vein endothel ium in experimental group, including necrosis and exfol iation of endoepithel ial cells, spl itting of the basement membrane, thickened lower layer of the endothelium with vacuoles and deformed vascular smooth muscle cells; however, integrated vessel intima was observed in control group.
ObjectiveTo investigate short-term outcomes and surgical techniques of endoscopic saphenous vein harvesting (ESVH) for coronary artery bypass grafting (CABG). MethodsClinical data of 554 patients undergoing CABG with ESVH in General Hospital of Shenyang Military between July 2009 and August 2013 were retrospectively analyzed. There were 372 male and 182 female patients with their age of 38-84(61.3±9.0) years. Clinical outcomes, postoperative lower extremity pain and edema, wound infection and healing were analyzed. ResultsDuring ESVH, 13 patients with very little subcutaneous fat received transition to skin bridge technology or partially open incision. Average number of harvested vein grafts was 1-4 (2.0±0.6), and the quality of the vein grafts was satisfactory. Postoperative lower extremity pain and edema were significantly reduced, and there was no delayed wound healing or infection. Seven patients died postoperatively, including 2 patients with perioperative myocardial infarction, 2 patients with pneumonia, 1 patient with ventricular fibrillation, 1 patient with massive cerebral infarction, and 1 patient with multiple organ dysfunction syndrome. A total of 452 patients were followed up for 120-1 460 (742.6±188.5) days. There was no late death or reintervention during follow-up. ConclusionESVH is a safe and efficacious procedure with less postoperative lower extremity pain and edema, satisfactory vein graft quality, better postoperative recovery and cosmetic results, compared with traditional fully or intermittently open wound for saphenous vein harvesting.
Abstract: Objective To compare minimally invasive technique with multiple short incisions and traditional open technique for great saphenous vein (GSV) harvesting in coronary artery bypass grafting (CABG). Methods Fortyseven patients underwent first time CABG between November 2007 to January 2009. These patients included 37 males and 10 females with their age ranged from 43 to 78 years and their average age was 61.3±84 years old. The patients were prospectively randomized into the minimally invasive harvesting group (group A,n=21) and the traditional open harvesting group (group B, n=26). For group A, we adopted the method of minimally invasive technique with multiple short incisions, while for group B, the traditional long incisions were adopted. The incision length, GSV harvesting time, lower limbs suture time and incision complications were compared between the two groups. Results During harvesting, no injury to the saphenous vein trunk or complications related to the quality of venous grafts occurred in both groups. There were no significantly differences in the number of venous grafts and the GSV length between the two groups. Group A had significantly longer GSV harvesting time than group B (51.9±11.5 min vs. 40.3±7.6 min,P=0.000). However, incision length (16.1±4.1 cm vs. 49.2±7.2 cm, P=0.000), incision suture time (11.0±3.0 min vs. 33.6±4.8 min,P=0.000) and lower limbs total operation time (62.6±14.9 min vs.73.8±11.6 min,P=0.006) in group A were much shorter than those in group B. Fortyseven patients were followed up (100%) and the followup time ranged from 3 to 26 months. The rate of leg wound complications such as serous exudates, hematomas and wound infection was 4.8% (1/21) in Group A and 34.6% (9/26) in Group B. These complications were all cured with additional treatments. Group A had lower leg wound complication rate than Group B (Plt;0.05). Conclusion Our study demonstrates that minimally invasive technique for GSV harvesting can be performed at a satisfactory speed and helpful in decreasing the lower limb incision complication rate.
Objective To explore the effect, operational essential, and clinical meaning of transilluminated powered phlebectomy for patients with varicose vein of the lower extremity. Methods In the study, 255 patients with 363 lower extremities of varicose vein in our hospital between May 2006 and November 2009 were treated by transilluminated powered phlebectomy. According to revised clinical etiology anatomic and pathophysiological classification system (CEAP), there were 104 limbs in C2, 53 limbs in C3, 155 limbs in C4, 34 limbs in C5, and 17 limbs in C6. The patients were followed up to observe postoperative complications. Results All varicose vein labeled before operation were resected. Surgical time was (100±20) min in unilateral lower extremity and (147±19) min in bilateral lower extremities. Total 221 patients (302 lower extremities) were followed up in 4 to 46 months, median follow up time was 24.5 months. Total 167 cases (247 lower extremities) had accepted the operation more than 1 year, 154 cases (229 lower extremities) in which were followed up. In the 229 lower extremities above, recurrences occurred in 11 extremities, small amounts of residual small varices were observed in 2 extremities, the recurrence rate was 5.68% (13/229). Twenty-one limbs with ulcer were healing in 3 to 6 weeks after operation. Postoperative complications: there was paresthesias or pain of ankle area in 16 limbs, which was improved in 3 to 6 months after physical therapy; there was ecchymosis of skin of leg in 112 limbs, which disappeared in 3 to 5 weeks after operation; there was light edema in 37 limbs, which disappeared in 1 to 2 weeks after operation; there was local hematoma in 2 limbs, incision light infection in 5 limbs, skin and subcutaneous tissue necrosis above medial malleolus in one limb, and back of knee popliteal skin lesion in 2 limbs, which were all cured by the symptomatic treatment. Conclusions Surgical treatment of varicose veins is actually the combination of various surgical procedures. Varicose vein extraction using transilluminated powered phlebectomy is safe, efficacious, and cosmetically satisfactory.
Objective To explore perioperative outcomes of coronary artery bypass grafting (CABG) using the radialartery as the second arterial graft. Methods Clinical data of 175 consecutive patients undergoing off-pump coronary artery bypass grafting (OPCAB) in General Hospital of Shenyang Military Command from August 2011 to April 2012 were retrospectively analyzed. All the 175 patients were divided into two groups. There were 75 patients including 49 male and 26 female patients with their age of 56.8±8.2 years in group 1,who received radial artery as a graft vessel. There were 100patients including 66 male and 34 female patients with their age of 57.7±8.1 years in group 2,who received great saphenousvein but not radial artery as the graft vessel. The use of left internal mammary artery as a graft vessel was 100% in both groups. Perioperative cardiovascular events and other clinical results were compared between the two groups. Results All the patients survived OPCAB and there was no 30-day death. There was no statistical difference in operation time,thoracic drainage within the first 24 hours after surgery or postoperative hospital stay between the two groups(P>0.05). Length of postoperative ICU stay and mechanical ventilation time of group 1 were shorter than those of group 2,although the differencewas not statistically significant. The percentage of patients receiving prolonged postoperative inotropic therapy of group 2 was higher than that of group 1 [16% (16/100) vs. 12% (9/75)],although the difference was not statistically significant. Postoperatively,there was no patient in group 1 who had new-onset myocardial ischemia or received intra-aortic balloon pump (IABP) support for hemodynamic instability. In group 2,3 patients had new-onset myocardial ischemia and 2 patientsreceived IABP support after OPCAB. Conclusion Radial artery can partly replace great saphenous vein as a graft vesselfor OPCAB,which does not increase the risk of perioperative cardiovascular events but is beneficial for postoperativerecovery to some degree. Radial artery can be more extensively used in CABG.
Objective To summarize the treatment outcomes of antegrade sequential anastomosis of great saphenous veins in off-pump coronary artery bypass grafting for coronary atherosclerotic heart disease. Methods A total of 116 patients with coronary atherosclerotic heart diseases underwent off-pump coronary artery bypass grafting from January 2013 to June 2015 in our hospital. There were 63 males and 53 females with a mean age of 42–80 (64.26±9.67) years. Left internal mammary artery was anastomosed to left anterior descending artery. The rest of the target vessels received antegrade sequential anastomosis of great saphenous veins with the order of proximal ascending aorta, diagonal branch, circumflex branch, obtuse marginal branch, left ventricular branch and posterior descending artery. Results All patients were performed off-pump coronary artery bypass grafting successfully without death or perioperative myocardial infarction. A total of 436 grafts were adopted with 3.75±0.53 in each patient. Three patients suffered low cardiac output syndrome, and were cured after administration of vasoactive drugs combined with the intra-aortic balloon pump. One patient suffered tardive pericardial tamponade and one acute renal failure, who were cured with disappearance of angina symptoms and increase of activities without discomfort. Conclusion Antegrade sequential anastomosis, as a safe and effective method, can reduce aortic stoma, save the length of grafts, shorten operative time and quickly restorate blood supply of myocardium in off-pump coronary artery bypass grafting.
Abstract: Objective To evaluate clinical outcomes of endoscopic vein harvesting (EVH)for coronary artery bypass grafting(CABG) in diabetic patients. Methods In this prospective non-randomized control study, patients with type 2 diabetes who underwent CABG from December 2010 to Febuary 2012 in West China Hospital were enrolled. Based on different vein graft harvesting technique, these patients were divided into two groups: an EVH group and a conventional vein harvesting(CVH)group. Perioperative complications were compared between the two groups. Interventional or CT coronary angiogram was used to evaluate bypass graft patency during follow-up. Results A total of 51 patients with type 2 diabetes were enrolled in this study with 24 patients in the EVH group and 27 patients in the CVH group. There was no statistical difference in age, weight, and comorbidities between the two groups. There was no statistical difference in cardiopulmonary bypass time and aortic cross-clamping time between the two groups (67.2±9.8 min versus 68.3±14.5 min, P>0.05; 62.4±11.3 min versus 65.2±10.3 min, P> 0.05). The vein graft harvesting time (35.6±6.4 min versus 45.2±11.4 min, P< 0.05)and rate of delayed leg wound healing(0.0% with 0/24 versus 18.5% with 5/27, P<0.05) of the EVH group were significantly shorter or lower than those of CVH group.There was no statistical difference in major postoperative complications with respect to venous graft failure rate and chest pain during short term follow-up(9.1 months in the CVH group and 9.4 months in the EVH group) between the two groups. Conclusion EVH is a safe, effective, minimally invasive and quick vein graft harvesting technique for CABG in diabetic patients.
This study was to observe the result in patients suffering from severe ischemia of legs with arterialization of the great saphenous vein. Eighty nine patients suffering from the disease were treated by bridging the autogenous cephalic vein or Gore-Tex artificial vessel between the great saphenous vein and the femoral or external iliac arteries. The results showed that the blood supply of the affected legs was increased immediately after operation. The ulcers of the toes and the plantar areas were healed gradually and the pain relieved. It was concluded that this method did not interfere with the reflux of the venous blood in the diseased limbs. This method was simple, safe and effective for treating severe ischemia of the lower limbs.
Abstract: Coronary artery bypass grafting (CABG) is one of the conventional treatments of coronary artery disease. Though the artery grafts have its own superiority, autologous great saphenous vein is still commonly used. Ten years after operation, half of the vein grafts will be occluded and half of the remainder will often undergo severe pathological conditions. The poor long term patency of vein grafts has become the bottleneck of the efficiency of CABG. The restenosis of vein grafts resulting from neointima and atherosclerosis has become an urgent problem waiting to be resolved. As the study on the molecular mechanism and pathophysiology of the vein grafts disease develops, many therapeutic schedules have been made, including drug therapy, external stent, expanding solution and gene therapy. By contrast, gene therapy has a broader prospect. This article will have a review on the prevention of restenosis of the vein grafts after CABG.