west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "Internal fixation" 279 results
  • TREATMENT OF DISPLACED RADIAL HEAD FRACTURES WITH INTERNAL FIXATION

    Objective To analyse the procedure and effectiveness of internal fixation in treatment of displaced radial head fractures. Methods Between August 2005 and May 2009, 35 patients with displaced radial head fractures underwent open reduction and internal fixation with SmartNail® and/or AO mini-plates. There were 28 males and 7 females with an average age of 28.4 years (range, 17-48 years). The injury mechanism included traffic accident in 16 patients, falling in 13, and falling from height in 6. According to Mason classification, 21 fractures were rated as type II, 9 as type III, and 5 as type IV. All fracturs were closed fractures. Six cases complicated by radial neck fractures, 1 case by olecranon fracture, 3 by posterior dislocations of the elbow, 1 by posterior dislocation of the elbow and coronoid process fracture, and 3 by medial collateral ligament injuries. The time from injury to operation was 3 to 7 days. Results Except 1 patient whose incision healed by second intention, healing of incision by first intention was achieved in the other patients. All patients were followed up 12-25 months with an average of 17 months. The average fracture healing time was 10.2 weeks (range, 8-16 weeks). At last follow-up, the average flexion and extension of the elbow was 119° (range, 95-145°). The average arc of forearm rotation was 126° (range, 90-175°). According to elbow functional evaluation criteria by Broberg and Morrey, the results were excellent in 18 cases, good in 13, and fair in 4; the excellent and good rate was 88.6%. Conclusion In treatment of displaced radial head fractures, open reduction and internal fixation can be performed with SmartNail® and/or AO mini-plates based on different fracture types and the short-term effectiveness is satisfactory.

    Release date:2016-08-31 05:45 Export PDF Favorites Scan
  • CLINICAL OBSERVATION OF ANTERIOR BONE GRAFT FUSION AND INTERNAL FIXATION TO TREAT ADJACENT MULTIVERTEBRAL TUBERCULOSIS IN ONE-STAGE

    To evaluate the method and effectiveness of anterior focus clearance with autograft bone fusion and internal fixation in treating of adjacent multivertebral tuberculosis in one-stage. Methods Between March 2007 and September 2009, 8 cases of thoracic vertebra tuberculosis were treated. Of 8 cases, 6 were male and 2 were female, aged 32 years on average (range, 20-42 years). The disease duration ranged from 8 to 14 months (mean, 10.2 months). Affected vertebrae included thoracic vertebrae in 35 cases and lumbar vertebrae in 11 cases; 5 vertebrae were involved in 4 cases, 6 vertebrae in 3 cases, and 8 vertebrae in 1 case. According to Frankel classification, there were 2 cases of grade C, 4 cases of grade D, and 2 cases of grade E. All patients had different kyphosis with the Cobb angle of (25.1 ± 6.6)°. All patients received antituberculous therapy 4-6 weeks preoperatively; after complete clearance lesions, autograft bone fusion and internal fixation were performed, and then antituberculous therapy was given for 18 months. Results All incisions healed by first intention. Eight patients were followed up 18-48 months (mean, 29 months). According to JIN Dadi et al. criterion, 7 cases recovered after first operation, 1 case of relapsed tuberculosis with sious was cured after re-focus clearance. The Cobb angle was (19.5 ± 4.2)° at 7 days after operation and was (22.3 ± 3.6)° at last follow-up, showing significant differences when compared with the preoperative value (P lt; 0.05). The nerve function of all cases were classified as Frankel grade E. CT scan showed bone graft fusion at 6-8 months after operation. No loosening or displacement of grafted bone and internal fixation occurred during follow-up. Conclusion The treatment of adjacent multivertebral tuberculosis by anterior focus clearance, intervertebral autograft, and internal fixation in one-stage is effective. Anterior bone fusion and internal fixation in one-stage can correct kyphosis effectively and rebuild spinal stabil ity, so it is a good choice for surgical treatment of adjacent multivertebral tuberculosis.

    Release date:2016-08-31 05:42 Export PDF Favorites Scan
  • TREATMENT OF SCHATZKER V/VI TIBIAL PLATEAU FRACTURE INVOLVED POSTEROMEDIAL CONDYLE THROUGH COMBINED APPROACH

    Objective To observe the cl inical results of treatment of Schatzker V/VI tibial plateau fracture involved posteromedial condyle through combined posteromedial and anterolateral approach and fixed with two or three plates. Methods From April 2005 to April 2008, 18 cases of tibial plateau fracture involved posteromedial condyle were treated, including 14 males and 4 females with an average age of 38.5 years old (range, 18-62 years old). According to Schatzker classification, there were 12 cases of type V and 6 cases of type VI. The posteromedial condyle were involved in 13 cases and bilateral posterior condyle in 5 cases. All patients were given posteromedial fragment and medial condyle fracture reduction through posteromedial approach firstly, and then lateral condyle fracture reduction through anterolateral approach, and injury of meniscuses and cruciate l igaments were treated at the same time. Three plates (lateral, medial, posterior) were used in 10 cases and two plates (lateral, posteromedial) in 8 cases. Results All wounds achieved heal ing by first intention without compl ications such as infection, flap necrosis, osteofascial compartment syndrome, chronic osteomyel itis, nonunion. All patients were followed up for 12 to 48 months with an average of 24.4 months. The mean flexion of the knee was 118.4° (range, 100-130°) 1 year after operation. According to Iowa evaluation system, 12 patients got excellent results, 4 good, and 2 fair; the excellent and good rate was 88.9%. Conclusion Combined posteromedial and anterolateral approach and fixed with two or three plates is effective in treatment of the Schatzker V/VI tibial plateau fracture involved posteromedial condyle. Anatomical reduction and rigid internal fixation of the posteromedial fragment are critical to successful operation.

    Release date:2016-09-01 09:08 Export PDF Favorites Scan
  • ANATOMICAL STUDY OF ANTERIOR APPROACH SCREW FIXATION THROUGH C2 VERTEBRAL BODY INTO C1 LATERAL MASS AND ITS PRIMARY CLINICAL APPLICATION

    Objective To explore the anatomic basis for theanterior approach screw fixation through the C2 vertebral body into the C1 lateral mass and toinvestigate its primary clinical application. Methods Twenty-one adult corpse specimens were anatomically measured. The minimum lateral angle α, the maximum lateral angle β, and the maximum posterior angle γ were calculated based on the data from the anatomic measurement. All the specimens were given an X-ray examination, the minimum lateral angle α, the maximum lateral angle β, and the maximum posterior angle γ were measured. The statistical analysis was made on the data obtained from the calculation in the specimens and the measurement in the X-ray films. The simulation of the approach was made onthe specimen. From October 2004 to July 2006, the simulated approach was used in 5 patients (3 males, 2 females; age, 30-55 years; illness course, 3 months-2 years) with the old atlanto-axial joint dislocation . The Frankel grading system revealed the spinal cord injury degree as follows: 1 patientwas in Grade B, 2 in Grade C, and 2 in Grade D. All the patients were treated with this surgical approach. The postoperative X-ray and CT examinations were performed. Results Angle α was 14.0±1.6°, β was 30.0±2.3°, γ was 29.0±2.9°. No significant difference existed between the angles calculated in the specimens and measured in the X-ray films (Pgt;0.05). The angles for the practical application during operation were as follows: α was 11.2±1.6°, β was 28.8±2.3°, and γ was 29.3±2.9°. The follow-up for an average of 14 months revealed that 1 patient recovered to Grade C, 1 to Grade D2, and 3 to Grade D3 in the spinal cord function according the modified Frankel grading system.Conclusion The anterior approach screw fixation through the C2 vertebral body into the C1 lateral massis feasible and safe in treatment of the old atlantoaxial joint dislocation ifthe screw insertion is exact in direction. This technique only makes the atlas temporarily stable, and so the posterior bone graft should be added into the atlantoaxial joint immediately in the one- or two-stage operation so as to achieve a long-lasting stability.

    Release date:2016-09-01 09:20 Export PDF Favorites Scan
  • TREATMENT OF CALCANEAL INTERARTICULAR FRACTURE BY OPEN REDUCTION AND INTERNAL FIXATION

    Objective To investigate the clinical outcome of open reduction and internal fixation of calcaneal interarticular fractures. Methods From August 1998, 38 calcanneal interarticular fractures in 35 cases, including 8 of type Ⅱ, 14of type Ⅲ and 16 of type Ⅳ according to Sander’s classification, were treatedby open reduction to restore the posterior articular facet, subtalar facet, Bohler angle and Gissane’s angle, following internal fixation by plastic titanicalloy plate. Thirtythree calcanneal interarticular fractures were followed up for6 to 22 months, 12.3 months on average; and the healing time and joint functionwere evaluated according to Maryland Foot Score System. Results The average healing time of fracture was 7.1 weeks, ranging from 5 to 12 weeks; and the joint function was excellent in 18 calcanneus, good in 13 calcanneus, and the satisfactory rate was 93.9%. Conclusion Open reduction and internal fixation with plastic titanium plate is a good choice for calcaneal interarticular fractures. 

    Release date: Export PDF Favorites Scan
  • OPERATIVE TREATMENT OF DISPLACED TALAR NECK FRACTURES WITH ABSORBABLE LAG SCREW

    OBJECTIVE: To study a new kind of operation for displaced talar neck fractures. METHODS: From April 1996 to March 2001, 9 talar neck fractures were treated by internal fixation of absorbable lag screw with a medial approach and cut of medial malleolus to expose the fractures. A non-weight-bearing below-knee cast was applied for 6 to 12 weeks after operation. Once union of the fracture site is apparent, the patient should remain non-weight bearing in a removable short-leg and keep exercise every day. RESULTS: All the patients received follow-up from 15 to 60 months with an average of 28 months. The fractures healed from 20 to 42 weeks. The excellent and good rate of function was 77.8% (7/9) according to American Orthopedic Foot and Ankle Society Score(AOFAS). One case had the complication of superficial infection of wound and skin edge necrosis after operation, which was Hawkins type III. Late complication included two cases of avascular necrosis(AVN). Among them, one AVN of Hawkins type II was caused by early weight-bearing five weeks after operation and gained the fair score. The other AVN of Hawkins type III was inefficient to conservative therapy and proceeded ankle fusion in the end. The AOFAS of the patient was bad. CONCLUSION: Treatment of talar neck fractures by internal fixation of absorbable lag screw with a medial approach is an ideal method. It can gain a satisfactory result by the operation, strict postoperative care and rehabilitation.

    Release date:2016-09-01 09:35 Export PDF Favorites Scan
  • ARTHROSCOPIC PERCUTANEOUS OSTEOSYNTHESIS OF LOW-ENERGY TIBIAL PLATEAU FRACTURES

    Objective To explore the treatment of low-energy tibial plateau fractures with arthroscopic percutaneous osteosynthesis. Methods From May 2004 to April 2008, 27 cases of tibial plateau fractures were treated with arthroscopic management. There were 19 males and 8 females, aged 18-61 years old (mean 41.5 years old). Fracture was caused by trafficaccident in 18 cases, by fall ing from height in 6 cases, by bruise in 2 cases, and by other in 1 case. There were 8 cases of type I, 12 cases of type II, 2 cases of type III and 5 cases of type IV according to Schatzker classification. The time from injury to operation was 3-15 days (mean 5.2 days). After symptomatic managements were performed arthroscopically in 11 cases of meniscus tear, 4 cases of medial collateral l igament rupture of knee joint, 3 cases of anterior cruciate l igament rupture of knee joint and 2 cases of cartilage fracture resulting in joint bodies, fracture was reduced and fixed with 2 or 4 cannulated screws (7 mm in diameter). Autograft of il ium was given 6 cases of bone defect. Early functional exercise was done. Results The operation time was 55-150 minutes (mean 93 minutes); the hospital ization days were 7-22 days (mean 16 days). All incision healed primarily. Edema of the affected leg occurred in all patients and subsided after 3 days of symptomatic management. In one patient who did not cooperate in functional exercise, adhesion occurred and normal function was recovered after by manual dissolution under conditions of anesthesia after 3 months of operation. All patients were followed up 6-36 months (mean 16.6 months). The range of motion of knee joint was 105-140° (mean 121°). According to Lysholm scale of knee joint, the score was 72-100 points (mean 93.6 points) 6 months after operation. The X-ray film showed no signs of osteoarthritis. Conclusion Arthroscopic percutaneous osteosynthesis yields satisfactory results and can be accepted as an alternative and effective method for the treatment of low-energy tibial plateau fractures.

    Release date:2016-09-01 09:08 Export PDF Favorites Scan
  • CANNULATED LAG SCREW COMBINED WITH LATERAL SUPPORTING PLATE FOR TREATMENT OF Hoffa FRACTURE OF Letenneur TYPE I AND TYPE III

    Objective To investigate the effectiveness of cannulated lag screws combined with lateral supporting plates in the treatment of Hoffa fracture of Letenneur type I and type III. Methods Between May 2004 and April 2011, 11 patients with Hoffa fracture of Letenneur type I and type III were treated, including 6 males and 5 females with an average age of 36 years (range, 25-47 years). Factures were caused by traffic accident in 8 cases, by falling in 2 cases, and by the other in 1 case. Fracture involved the left knee in 7 patients and the right knee in 4 patients. According Letenneur’s classification criteria, there were 7 type I fractures (6 lateral condyle fractures and 1 medial condyle fracture) and 4 type III fractures (3 lateral condyle fractures and 1 medial condyle fracture). Of 11 fractures, 9 were fresh fractures and 2 were old fractures. Two 6.5 mm cannulated lag screws combined with lateral supporting plates were used to fix fractures by anterolateral or anteromedial incision. Results All incisions achieved primary healing with no early complication. All patients were followed up 12-26 months (mean, 15 months). X-ray films showed bone healing with an average healing time of 15 weeks (range, 10-18 weeks). No loosening or breaking of internal fixator was observed; the removal time of internal fixation was 9-15 months (mean, 12 months). Accoding to Letenneur’s functional assessment system, the results were excellent in 7 cases, good in 3 cases, and poor in 1 case at last follow-up. Conclusion Cannulated lag screws combined with lateral supporting plates fixation is effective in treatment of Hoffa fracture of Letenneur type I and type III with a high union rate; anterolateral or anteromedial approach is the first choice for Hoffa fracture of type I and type III, especially for complicating by tibial plateau fracture or patella fracture.

    Release date:2016-08-31 04:12 Export PDF Favorites Scan
  • COMPARISON OF MEDIUMTERM X-RAY IMAGINGS BETWEEN ANATOMIQUE BENOISTGIRAUD HIP AND ANATOMIC MEDULLARY LOKCING HIP

    Objective To compare the bone resorption between the proximal fixation of the anatomique benoist giraud(ABG) hip and the distal fixation of the anatomic medullary locking(AML) hip by the medium-term X-ray films, and to evaluate the clinical results of the two prostheses. Methods From January 1992 to December 1996, 298 patients (396 hips) underwent the total hip arthroplasty at Wilson Hospital in Korea. In 125 patients, 176 hips were ABG hips, including 103 avascularnecrosis hips, 57 dysplasia hips, and 16 other diseased hips; In the other 173 patient the remaining 220 hips were AML hips, including 147 avascular necrosis hips, 65 dysplasia hips, and 8 other diseased hips. The A-P X-ray imagings were followed up for 5-12 years averaged 8 years, and were compared with the immediate postoperative X-ray imagings. The bone resorption area was measured and the bone resorption cases were recorded according to the Gruen zone obsesvation. Results During operation, 2 ABG hips and 5 AML hips were cracked at the femoral diaphysis; 3 ABG hips and 1 AML hip were cracked at the metaphysis; 6 ABGhips and 3 AML hips were fractured because of trauma after operation; among them, 2 ABG hips needed the stem revision and the remaining hips underwent the openreduction and the internal fixation. During the follow-up, 9 ABG hips were revised, 7 hips of which developed the aseptic loosening. No AML hip was revised, but 3 AML hips developed the aseptic loosening. The bone resorption pattern in theABG and AML hips was similar. The bone resorption occurred most commonly in theGruen zones 1 and 7, and it extended from the metaphysis to the diaphysis. In the Guren zones 2, 5, 6 and 7, there were more AML hips than ABG hips that developed the bone resorption. The bone resorption area around the AML hip was larger than that around the ABG hip. Conclusion The stress shielding bone resorption usually occurs proximally to the union area of the bone and the prosthesis. The ABG prosthesis is a proximal fixation prosthesis, therefore, the stress shielding bone resorption can be reduced. The bone resorption around the AML prosthesis develops slowly within 10 years after operation. The stress shielding bone resoption may reach the summit within 10 years and it will not develop endlessly, so the prosthesis will be stable for a long time. The probabilityof the bone resorption in the ABG prosthesis is smaller than that in the AMLprosthesis. The bone resorption around the AML prosthesis may develop slowly after 10 years and will not affect the stability of the prosthesis for a long time.

    Release date:2016-09-01 09:23 Export PDF Favorites Scan
  • PRELIMINARY EFFECTIVENESS OF I.T.S. LOCKING PLATE FOR INTRA-ARTICULAR CALCANEAL FRACTURES

    Objective To summarize the preliminary effectiveness of I.T.S. locking plate for intra-articular calcaneal fractures. Methods Between July 2010 and July 2011, 18 cases of intra-articular calcaneal fractures were treated. There were 10 males and 8 females with an average age of 46 years (range, 25-64 years). According to Sanders classification system, there were 3 cases of type II, 9 cases of type III, and 6 cases of type IV. The disease duration was 5-11 days (mean, 6 days). Open reduction and internal fixation with I.T.S. locking plate were performed via an L-shaped lateral extending incision. Results Superficial infection occurred in 1 case, and was cured after dressing changing; healing of incision by first intention was obtained in the other cases. Sixteen cases were followed up 14 months on average (range, 12-18 months). X-ray films demonstrated the bone union in all cases with an average union time of 12 weeks (range, 10-14 weeks). No implant failure or irritation of peroneal tendon occurred during follow-up. X-ray films showed subtalar post-traumatic arthritis with mild pain in 1 case at 11 months after operation, which was relieved by conservative treatment. At last follow-up, the Bouml;hler angle was improved from (12.9 ± 3.2)° preoperatively to (33.8 ± 4.0)° postoperatively, showing significant difference (t=22.78, P=0.00); the Gissane angle was improved from (83.6 ± 6.4)° preoperatively to (119.9 ± 8.5)° postoperatively, showing significant difference (t=17.02, P=0.00). The visual analogue scale (VAS) score was 1.3 ± 1.2, and the ankle and hindfoot scale of American Orthopaedic Foot and Ankle Society (AOFAS) was 80.3 ± 7.9 at last follow-up. Conclusion Treatment of intra-articular calcaneal fracture with I.T.S. locking plate can obtain a stable fixation, which is a safe and effective method.

    Release date:2016-08-31 04:12 Export PDF Favorites Scan
28 pages Previous 1 2 3 ... 28 Next

Format

Content