find Keyword "Intramedullary" 24 results
  • STUDY AND CLINICAL APPLICATION OF AUTO-COMPRESSIVE AND ANTI-CIRCUMROTATE INTRAMEDULLARY NAIL

    ObjectiveTo design an auto-compressive and anti-circumrotate intramedullary nail( ACACIN) and to evaluate the preliminary clinical efficacy on fixing adult femur fracture. Methods From January 1998 to June 2001, 23 patientswith femur fracture were stabilized with auto-compressive and anti-circumrotateintramedullary nail. 2-4 elastic blocks were installed into the proximal and distal different distance of quincunx nail to defend circumrotate and axis compress. Results Fracture healing were obtained in all 23 patients treated with auto-compresseiveand anti-circumrotate intramedullary nail, the time of fracture healing was 6-13 weeks in 21 cases and 15-22 weeks in 2 cases of old fracture. There was no complication related to infection, nail break, abnormal union and joint ankylosis. The results were excellent in 19 cases, good in 3 cases, and moderate in 1 case according Kolmert’s criterion for function ; the effective rate was 95.7%. Conclusion Auto-compressive and anti-circumrotate intramedullary nail has a suitable radian for adult femur, can afford stable fixation, anti-circumrotate andaxis compress.

    Release date:2016-09-01 09:35 Export PDF Favorites Scan
  • Non-reamed versus Reamed Intramedullary Nailing for Tibial Fractures in Adults: A Systematic Review

    Objective To determine the effect of non-reamed versus reamed intramedullary nailing for tibial fractures in adults on the rates of nonunion, the rates of implant failure, the rates of infection, the incidence of compartment syndrome, the rates of malunion, and the time of union. Methods We searched MEDLINE (1966 -July, 2005), EMBASE (1974 -July, 2005 ), The Cochrane Library (Issue 2, 2005 )and CBMdisc (1979 -July, 2005 ), and handsearched the relevant Chinese and English orthopedic journals. Randomized controlled trials and Clinical controlled trials of nonreamed versus reamed intramedullary nailing for tibial fractures in adults were included. The quality of trials was critically assessed. RevMan 4.2.7 software was used for data analysis. Results Four RCTs and one CCT of non-reamed versus reamed intramedullary nailing for tibial fractures in adults were included. The results of meta-analysis showed that nonreamed intramedullary nailing for tibial fractures in adult increased the rates of nonunion (RR 1.87, 95% CI 1.20 to 2. 91, P =0. 006), implant failure (RR 2.23, 95% CI 1.49 to 3.34, P〈0. 000 1 ) and the time to union (WMD 9.00, 95% CI 3.19 to 14.81, P =0. 002). Conclusions Compared with reamed intramedullary nailing for tibial fractures in adults, non-reamed intramedullary nailing increases the rates of nonunion and implant failure is common. There is no statistical difference in the rates of post operative infection, the rates of malunited fracture and the incidence of compartment syndrome between the two groups. However, further studies are needed to determine the effects of reamed and non-reamed intramedullary nailing on these outcomes, expecially when patient has severe open fractures (Gustilo Grade Ⅲ C)and multiple injuries.

    Release date:2016-09-07 02:25 Export PDF Favorites Scan
  • Application of MultiLoc intramedullary nail technique in the treatment of proximal humeral fracture

    Because of the complexity of proximal humeral fractures, the treatment of proximal humeral fractures has always been a challenge for clinicians. The MultiLoc intramedullary nail is a new type of internal fixation device which has been gradually used in the treatment of proximal humeral fractures in recent years. At present, it is mainly used in the Neer two- and three-part fractures, especially surgical neck fractures. Its flexible design can provide personalized and multi-plane fixation for fracture patients, “screw-in-screw” and medial supporting screw can effectively reduce the axial displacement and varus angle of humeral head, and minimally invasive surgical incision can reduce the injury of rotator cuff. This review focuses on the research status and related evidence of the design, operation, prognosis, and postoperative complications of MultiLoc intramedullary nail, in order to provide a theoretical basis for the application of MultiLoc intramedullary nail in fracture treatment, and enhance clinicians’ understanding of MultiLoc intramedullary nail as a new type of internal fixation device.

    Release date:2021-01-26 04:34 Export PDF Favorites Scan
  • DEVELOPMENT AND CLINICAL APPLICATION OF AN INTRAMEDULLARY CONTROLLED DYNAMIC NAI LING

    Objective To describe the design and application of a new intramedullary controlled dynamic nailing(ICDN).〓〖WTHZ〗Methods The new ICDN was made of a stainlesssteel alloy, consists of a nail shaft, innerrod, tensile screw, end cape and two interlocked screws. From December 2005 toFebruary 2007, 48 cases of femoral shaft fractures were treated with ICDN. There were 16 females and 32 males with a mean age of 36.6 years (range, 16-48years). Injury was caused by traffic accident in 26 cases, falling from a height in14, sportsrelated in 7 and crush injury in 1 case. According to Winquist classification, Thirtyseven cases were classified as typeⅠ(13 cases of typeⅠ-1,23 cases of Ⅰ-2 and 1 case of Ⅰ-3), eleven as type Ⅱ fracture ( 2 cases oftype Ⅱ-1, 8 cases of Ⅱ-2 and 1 case of Ⅱ-3). The time from injury to admission was an hour to a week. Emergency operation was performed in 19 cases and the other 29 patients were given operation within 3 days. Results All cases were followed up for an average of 5 months (3-12 months). Among them, the average healing period was 21 weeks (826 weeks) and no nonunion, delayed union and breakage of nailings occurred. The complications included 2 infections, 5 pains, and 4 deformities. Based on Johner and Wrubs standard, the results were excellent in 39 cases, good in 7 cases and fair in 2 cases, The excellent and good rate was 95.8%. Conclusions ICDN has excellent biomechanical characteristics which can provide a flexible fixation in treating femoral shaft fractures. The operation is simple and is one of the good techniquesin treating femoral shaft fractures.

    Release date:2016-09-01 09:22 Export PDF Favorites Scan
  • BONE TRANSPORTATION BY RING TYPE EXTERNAL FIXATOR COMBINED WITH LOCKED INTRAMEDULLARY NAIL FOR TIBIAL NON-INFECTIOUS DEFECT

    ObjectiveTo explore the effectiveness of bone transportation by ring type extenal fixator combined with locked intramedullary nail for tibial non-infectious defect. MethodsBetween June 2008 and October 2012, 22 cases of tibial large segment defect were treated. There were 15 males and 7 females, aged 24-58 years (mean, 36.8 years), including 17 cases of postoperative nonunion or malunion healing, and 5 cases of large defect. After debridement, bone defect size was 5.0-12.5 cm (mean, 8.05 cm). Bone transportation was performed by ring type external fixator combined with locked intramedullary nail, the mean indwelling duration of external fixation was 10.2 months (range, 2-26 months); the external fixation index was 1.57 months/cm (range, 0.3-3.2 months/cm); and the mean length increase was 8.05 cm (range, 5.0-12.5 cm). ResultsAll patients were followed up 19-58 months (mean, 32 months). No infection occurred after operation and all patients obtained bony union, and the union time was 4.7-19.4 months (mean, 11.9 months). Complications included refracture (1 case), skin crease (1 case), lengthening failure (1 case), foot drop (2 cases), retractions of the transport segment (1 case), delay of mineralization (1 case), which were cured after corresponding treatment. According to Hohl knee evaluation system to assess knee joint function after removal of external fixator and intramedullary nail, the results were excellent in 15 cases, good in 5 cases, and fair in 2 cases, with an excellent and good rate of 90.9%; according to Baird-Jackson ankle evaluation system to evaluate ankle joint function, the results were excellent in 10 cases, good in 3 cases, fair in 7 cases, and poor in 2 cases, with an excellent and good rate of 59.1%. ConclusionBone transportation by ring type external fixator combined with locked intramedullary nail could increase stability of extremities, allow early removal of external fixator and avoid axis shift of extremities, so it has good effect in treating tibial noninfectious defect.

    Release date: Export PDF Favorites Scan
  • Plating versus Intramedullary Nailing of Humeral Shaft Fractures in Adults: A Systematic Review

    Objective To compare the efficacy of plating versus intramedullary nailing in the treatment of adult humeral shaft fracture. Methods We identified eligible studies in PubMed (1950 to September 2007), MEDLINE (1950 to September 2007), OVID CINAHL (1950 to September 2007), OVID EBM (3rd Quarter 2007), CBMdisk (1978 to June 2007) and CNKI (1981 to June 2007). We also handsearched several Chinese orthopedic journals. Data were extracted and evaluated by two reviewers independently. Randomized controlled trials (RCTs) comparing plating versus intramedullary nailing for humeral shaft fracture in adults were included and the quality of these trials was critically assessed. Data analyses were conducted with Stata 10.0. Results Six RCTs involving 425 patients were included, among which the statistical heterogeneity was not significant (Pgt;0.1). Cumulative meta-analyses showed that intramedullary nailing might increase the re-operation rate in studies conducted before the year of 2000 (OR=0.39, 95%CI 0.17 to 0.90, P=0.03), but the difference was not significant in studies conducted after 2000 (OR=0.54, 95%CI 0.27 to 1.08, P=0.08). Intramedullary nailing might increase the incidence of shoulder impingement compared with plating (OR=0.13, 95%CI 0.03 to 0.65, P=0.01). The rates of non-union, deep infection, iatrogenic radial nerve injury and internal fixation failure were similar between plating and intramedullary nailing. Meta-analyses were not conducted for union time, operation time and bleeding (transfusion) volume, because the relevant data were not available from the included trials. Conclusion Intramedullary nailing may increase the incidence of shoulder impingement. The rates of re-operation, non-union, deep infection, iatrogenic radial nerve injury and internal fixation failure are similar between plating and intramedullary nailing. Further well-designed and large-scale randomized controlled trials are required to determine the effects of plating and intramedullary nailing on these outcomes.

    Release date:2016-09-07 02:13 Export PDF Favorites Scan
  • CLINICAL STUDY OF PHALANGE FRACTURES TREATED BY ABSORBABLE INTRAMEDULLARY NAIL IN REPLANTATION OF SEVERED FINGER

    Objective To study the effect of internal fixation with absorbable intramedullary nail on the treatment of phalange fractures in replantation of severed finger. Methods From September 2001 to October 2003, 28 cases with industrial severed finger (21 males and 7 females, with the age of 18-35 years) were replanted within 1-6 hours. The severed locations were index fingers in 11 cases, middle fingers in 8 cases, ring fingers in 6 cases, little fingers in 3 cases. All cases of phalange fractures were fixed by absorbable intramedullary nails of poly-DL-lactic acid(PDLLA) that combined with chitosan. Out of the 28 cases, 15 cases were with proximal phalange, 11 cases were with middle phalange, 2 cases were with distal phalange. The bone marrow cavity of the phalanges were dilated, then the intramedullary nail was inserted with suitable diameter and length to fix the fracture. Postoperatively resin bandage was applied for 3-4 weeks.Results All the 28 patients survived the performance and postoperative follow-up ranged from 3 to 10 months(4 months in average). Rejection was observed in one case 3 weeks after operation, bone unions were obtained in other cases. According to the Chinese Medical Association’s evaluation standard for replantation of amputated finger, 18 fingers resulted in excellence, 9 fingers in good function and 1 with unsatisfactory function. The excellent and good rate was 96.4%. Conclusion Internal fixation with absorbable intramedullary nail of PDLLA combined with chitosan proves to be effective in the replantation of severed finger.

    Release date:2016-09-01 09:29 Export PDF Favorites Scan
  • RESEARCH PROGRESS IN LOWER LIMB LENGTHENING BY INTRAMEDULLARY NAIL

    ObjectiveTo summarize the research progress in the lower limb lengthening by intramedullary nail. MethodsThe domestic and foreign related literature about the lower limb lengthening by intramedullary nail was reviewed, summarized, and analyzed. ResultsThe intramedullary nail lengthening systems can be divided into 3 types:distraction by mechanical strength, by motorized electronic power, or by motorized magnetic force. The new technology has obvious advantages in complication incidence, limb function, bone healing rate, comfortable and cosmetic degree of the patients, and hospitalization days compared with the external fixation, but it also has the disadvantages including lengthening failure of system breakdown, intramedullary infection, injuries of vessel and nerve, limited distraction length, and expensive price of the apparatus. And the method also has several contraindications:narrow medulla, multiple curves of medulla, osteomyelitis, skin infection, and unclosed epiphyseal plate. ConclusionThe lower limb lengthening by intramedullary nail is a major improvement of Ilizarov technology. Although the method has been used in limited cases, the preliminary clinical results are excellent, and it can be regarded as a new trend of the limb lengthening, bone reconstruction, and deformity correction.

    Release date: Export PDF Favorites Scan
  • Comparative Study on the Effect of Reamed and Nonreamed Intramedullary Nails on Treating Open Tibial Fractures

    Objective To compare the clinical effect of reamed and nonreamed intramedullary interlocking nails on treating open tibial fractures. Methods From February 2002 to February 2004, 92 cases of open tibial fractures (86 patients) were treated with intramedullary interlocking nails. Of the 86 patients, 65 were male and 21 were female. Their age ranged from 18 to 68 years (36.5 on average). Of the 92 cases, 54 were in the reamed group and 38 in the nonreamed group. Patients moved with the support of crutch after their wounds were healed. Results All patients were followed up regularly for 6 to 24months. Infection rate in the reamed group and nonreamed group was 20.3% and 5.3% respectively, and there was significant difference between them (Plt;0.05). The averagehealing time of the fractures was 22.5 weeks in reamed group and 19 weeks in nonreamed group, and there was no significant difference between them (P>0.05). Delayed unions occurred in 8 cases and 3 cases in reamed group and nonreamed group respectively. Conclusion Compared with reamed group, nonreamed intramedullary interlocking nails have lowerinfection rate and fewer delayed unions and ununions.

    Release date:2016-09-01 09:24 Export PDF Favorites Scan
  • Intramedullary Nailing or Compression Plates for Humeral Shaft Fractures in Adults: A Systematic Review

    Objective To determine the efficacy and complication rate of intramedullary nailing versus compression plate in the treatment of adult humeral shaft fracture. Methods We searched the specialized trials register of The Cochrane Collaboration’s Bone, Joint and Muscle Trauma Group, The Cochrane Library (including CENTRAL), MEDLINE (1966 to 2006), EMbase (1980 to 2006), PubMed (1966 to 2006), NRR , CCT and CBMdisc (1979 to July 2006). We also handsearched some Chinese orthopedic journals. Data were extracted and evaluated by two reviewers independently. Randomize controlled trials comparing intramedullary nailing versus compression plate for humeral shaft fracture in adults were included and the quality of these trials was critically assessed. Data analyses were done using The Cochrane Collaboration’s RevMan 4.2.8. Results Three randomize controlled trials involving 215 patients were included. The meta-analysis showed that intramedullary nailing may increase the re-operation rate (OR=2.68, 95%CI 1.19 to 6.04, P=0.02), pain in the shoulder (OR=13.02, 95%CI 2.23 to 75.95, P=0.004), and the rate of decreased range of motion of the shoulder (OR=18.60, 95%CI 1.01 to 341.83, P=0.05). The rates of no union, infection and iatrogenic radial nerve injury were comparable between intramedullary nailing and compression plate. Meta-analysis was not conducted for the time of union, because the relevant data were not available for the included trials. Conclusions Further well-designed and large-scale randomize controlled trials are required to determine the effects of intramedullary nailing and compression plate on these outcomes, because the trials available for this systematic review are too few and too small.

    Release date:2016-09-07 02:17 Export PDF Favorites Scan