Objective To investigate the effectiveness of basal osteotomy of the first metatarsal combined with first metatarsophalangeal joint replacement for the treatment of hallux valgus combined with hallux rigidus. Methods A retrospective analysis was conducted on the medical records of 15 patients (16 feet) with hallux valgus combined with hallux rigidus who underwent first metatarsal osteotomy combined with first metatarsophalangeal joint replacement between May 2019 and December 2024. The patients included 1 male and 14 females, aged 60-80 years, with an average age of 68.5 years. According to the Mann classification of hallux valgus, 2 feet were moderate and 14 feet were severe. According to the Hallux Rigidus Coughlin grading, 12 feet were grade 3 and 3 feet were grade 4. The evaluation indicators included hallux valgus angle (HVA) and 1-2 inter metatarsal angle (1-2 IMA) measured on weight-bearing X-ray film at preoperation and last follow-up; the American Orthopaedic Foot and Ankle Society (AOFAS) score and visual analogue scale (VAS) score were used to evaluate the improvement of walking function, metatarsophalangeal joint function, and pain relief in patients. Results All patients underwent surgery successfully without complications such as vascular or nerve injury during operation. One foot developed a superficial incisional infection postoperatively, which healed after dressing changes; the remaining 15 feet had primary incision healing. All patients were followed up 5-55 months, with an average of 17.5 months. All osteotomies achieved bony union, with a union time ranging from 8 to 13 weeks, averaging 11.8 weeks; no elevation of the first metatarsal was observed. At last follow-up, no complications such as prosthesis loosening, dislocation, fracture, toe shortening, bone dissolution, synovial reaction, or metatarsalgia were found. The appearance and function of the affected feet significantly improved, and the pain significantly relieved. At last follow-up, the HVA, 1-2 IMA, AOFAS score, and VAS score showed significant differences when compared with preoperative values (P<0.05). Conclusion Basal osteotomy of the first metatarsal combined with first metatarsophalangeal joint replacement for the treatment of hallux valgus with hallux rigidus can correct deformities through osteotomy, restore the normal flexion-extension axis of the metatarsophalangeal joint, relieve pain, and preserve a certain degree of mobility, achieving good medium-term effectiveness.
Since Swanson designed the silicone small joint prosthesis, the material and design of the small joint prosthesis have been constantly innovating. The number of small joint reconstruction and arthroplasty has gradually increased in the past decade. The numerous studies have focused on design and application of new material prosthesis and its long-term effectiveness analysis, in order to overcome prosthesis loosening, shift, dislocation, and poor function problem, at the same time to challenge the difficulty of the small joints revision procedures. Although the small joint prosthesis which has got the overall performance of the Swanson joints and been mature and stable like a knee joints prosthesis has not been obtained, but the small joint development has made revolutionary changes in the treatment of joint diseases, and the prosthesis selection criterion and surgical technique tendency solution have been established. In the future, digital three-dimensional printing, regenerative medicine, and translational medicine will contribute to the development of small joint reconstruction and replacement.
【摘要】 目的 报道1例静脉滴注胺碘酮致肝肾功能不全患者。 方法 2010年10月收治1例扩张性心肌病患者,治疗过程中使用胺碘酮注射液,导致严重的肝肾功能不全。系统查阅中国期刊全文数据库及外文数据库Pubmed、Embase建库至2011年8月关于胺碘酮致肝肾功能不全的相关文献,进行静脉胺碘酮致肝肾功能不全的可能性评估,探索胺碘酮静脉滴注致肝功能不全的的作用机制。 结果 根据查阅文献结果分析,此患者静脉注射胺碘酮致肝功不全的可能性高,Naranjo概率评分分别为7分。 结论 提出临床医师和临床药师应进行胺碘酮静脉的药学监护,高度的重视胺碘酮相关的不良反应,从而及时识别和防治胺碘酮所致肝肾功能不全,减少其不良预后。【Abstract】 Objective To report a case of hepatic and renal insufficiency induced by intravenous injection with amiodarone, and to evaluate the possibility of the adverse drug reaction. Methods A patient with dilated cardiomyopathy was admitted in October, 2010. During the procedure, the use of amiodarone hydrochloride injection made the patient suffer from liver and kidney dysfunction. We retrieved the literatures about liver and kidney toxicity of amiodarone from CNKI, Pubmed, and Embase (from the establishment of the databases to November 2011). We also ssessed the possibility of the adverse drug reaction, discussed the mechanism of amiodarone-induced hepatic insufficiency. Results According to the literature, There was a great possibility of hepatic insufficiency induced by amiodarone, and the total score of the Naranjo probability score was 7. Conclusion It is important to pay more attention to the pharmaceutical care of amidarone to timely recognize and effectively prevent or treat hepatic and renal insufficiency induced by intravenous injection with amiodarone.