ObjectiveTo explore the effectiveness of pedicled anterolateral thigh myocutaneous flap for full-thickness abdominal wall reconstruction after tumor resection.MethodsBetween September 2010 and December 2017, 18 patients with abdominal wall tumors were collected. There were 11 males and 7 females, with an average age of 45.2 years (range, 29-68 years). Histologic diagnosis included desmoid tumor in 8 cases, sarcomas in 6 cases, malignant teratoma in 2 cases, and colon adenocarcinoma in 2 cases. All abdominal wall defects were full-thickness defects. Peritoneum continuity was reconstructed with mesh; the lateral vastus muscular flaps were used to fill the dead space and rebuild the abdominal wall strength; the abdominal wall soft tissue defects were repaired with pedicled anterolateral thigh flaps. The size of abdominal wall defects ranged from 15 cm×6 cm to 25 cm×22 cm; the size of lateral vastus muscular flap ranged from 10 cm×8 cm to 22 cm×10 cm; the size of anterolateral thigh flap ranged from 14.0 cm×8.0 cm to 21.0 cm×8.5 cm. The bilateral pedicled anterolateral thigh myocutaneous flaps were harvested to repair the extensive abdominal wall defects in 2 cases. All donor sites were sutured directly.ResultsAll wounds healed smoothly and all flaps survived totally. All donor sites healed smoothly. The mean follow-up time was 22.5 months (range, 11-56 months). No tumor recurrence occurred, the abdominal function and appearance were satisfactory, no abdominal hernia was noted. Only linear scar left at the donor sites.ConclusionPedicled anterolateral thigh myocutaneous flap combined with mesh is fit for large full-thickness abdominal defect reconstruction.
Objective To investigate the reconstructive methods and effectiveness of modified pedicled anterolateral thigh (ALT) myocutaneous flap for large full-thickness abdominal defect reconstruction. Methods Between January 2016 and June 2018, 5 patients of large full-thickness abdominal defects were reconstructed with modified pedicled ALT myocutaneous flaps. There were 3 males and 2 females with an average age of 43.7 years (range, 32-65 years). Histologic diagnosis included desmoid tumor in 3 cases and sarcoma in 2 cases. The size of abdominal wall defect ranged from 20 cm×12 cm to 23 cm×16 cm. Peritoneum continuity was reconstructed with mesh; lateral vastus muscular flap was used to fill the dead space and rebuild the abdominal wall strength; skin grafting was applied on the muscular flap, the rest abdominal wall soft tissue defects were repaired with pedicled ALT flap. The size of lateral vastus muscular flap ranged from 20 cm×12 cm to 23 cm×16 cm, the size of ALT flap ranged from 20 cm×8 cm to 23 cm×10 cm. The donor site was closed directly. Results All flaps and skin grafts survived totally, and incisions healed by first intention. All patients were followed up 6-36 months (mean, 14.7 months). No tumor recurrence occurred, and abdominal function and appearance were satisfying. No abdominal hernia was noted. Only linear scar left in the donor sites, and the function and appearance were satisfying. Conclusion Modified pedicled ALT myocutaneous flap is efficient for large full-thickness abdominal defect reconstruction, decrease the donor site morbidity, and improve the donor site and recipient site appearance.
Objective To investigate the clinical application of relaying anteromedial thigh (AMT) perforator flap in resurfacing of the donor defect after anterolateral thigh (ALT) flap transfer. Methods Between February 2012 and December 2015, 23 cases of oral carcinoma underwent radical resection; after resection of lesions, the tongue or mouth floor defects were reconstructed by ALT perforator flaps, and the donor sites were repaired with relaying AMT perforator flap at the same stage. There were 21 males and 2 females,with a mean age of 52.6 years (range, 29-74 years). Sixteen patients had tongue squamous cell carcinoma and 7 patients had buccal cancer. According to TNM tumor stage, 3 cases were classified as T4N0M0, 5 cases as T4N1M0, 7 cases as T3N1M0, 5 cases as T3N2M0, and 3 cases as T3N0M0. The disease duration ranged from 6 to 18 months (mean, 8.8 months). Results The AMT perforators existed consistently in all patients. All flaps survived, and primary healing of wounds was obtained at recipient sites and donor sites. No vascular crisis, wound dehiscence, or obvious swelling occurred. All patients were followed up 6-20 months (mean, 9.4 months). There was only linear scar at the donor sites, and the function of thighs was normal. The color and contour of the flaps were satisfactory. Conclusion The relaying AMT perforator flap is an ideal choice to reconstruct the donor site of ALT flap.
ObjectiveTo investigate the effect of indocyanine green (ICG)-based fluorescent angiography in autologous tissue breast reconstruction.MethodsBetween June 2016 and June 2017, 14 female patients were treated with the autologous tissue breast reconstruction. The age ranged from 27 to 64 years with the median age of 46.5 years. There were 11 patients of one-stage reconstruction, including 9 with invasive ductal carcinoma of breast, 1 with recurrence tumor on chest wall, and 1 with angiosatcoma in the breast. The disease duration ranged from 9 days to 48 months (mean, 6.8 months). There were 3 patients of second-stage breast reconstruction, who underwent mastectomy 3-4 years ago. During operation, the first ICG-based fluorescent angiography was done before cutting off the flap pedicle. According to the results, 13 patients were adjusted the strategy of operation or cut part of flap, only 1 patient kept the original design. Then, the infusion of flaps were confirmed by the second ICG-based fluorescent angiography after transplanted to the recipient site. The area of flap ranged from 24 cm×11 cm to 36 cm×15 cm. All incisions of recipient site were closed by primary suture.ResultsThe fat liquefaction of incision occurred in 1 patient with type 2 diabetes, and the incision healed after debridement operation. The other flaps survived with no flap perfusion related complication. Both donor sites and recipient sites healed by first intention. All patients were followed up 1-14 months (mean, 4 months) with satisfied result of reconstruction. There was no tumor recurrence.ConclusionICG-based fluorescent angiography can reveal the perfusion of the flap in operation instantly and accurately. It should be very helpful to adjusting the strategy in reconstructive operation, especially in the large tissue demanded kinds such as breast reconstruction.
ObjectiveTo investigate the effectiveness of bipaddled anterolateral thigh perforator flap in repair of through-and-through maxillofacial defect following oral cancer ablation.MethodsBetween January 2008 and December 2016, 42 patients with oral cancer were treated. There were 31 males and 11 females with an average age of 44.5 years (range, 31-68 years). There were 28 cases of buccal mucosa carcinoma, 10 cases of basal cell carcinoma of buccal skin, 3 cases of gingiva carcinoma, and 1 case of recurrent parotidduct carcinoma. The disease duration ranged from 1 to 24 months (mean, 13.5 months). The size of through-and-through maxillofacial defect ranged from 6.0 cm×4.5 cm to 9.0 cm×7.0 cm. All defects were repaired with the bipaddled anterolateral thigh perforator flap. The paddles were adjusted to repair the buccal area. And the size of flap ranged from 7 cm×5 cm to 10 cm×8 cm. The donor sites were closed directly.ResultsThe operation time was 4.5-7.5 hours (mean, 5.5 hours). All flaps healed and the wounds of recipient and donor sites healed by first intention. All patients were followed up 9-60 months (mean, 22 months). All patients were satisfied with their facial appearance and the speech function. The range of mouth opening was 3-5 cm. Three patients died of recurrence during the follow-up period and the other patients were alive.ConclusionThe bipaddled anterolateral thigh perforator flap is flexible and reliable for the through-and-through maxillofacial defect reconstruction following oral cancer ablation.
ObjectiveTo explore the clinical application of combined transverse upper gracilis flap and adductor magnus perforator flap in breast reconstruction of breast cancer patients after mastectomy.MethodsBetween August 2016 and February 2017, the combined transverse upper gracilis flap and adductor magnus perforator flap was used in 12 cases of breast cancer patients who received modified radical surgery for breast reconstruction. All patients were females with the age of 32 to 59 years (mean, 41.5 years). There were 7 cases in left side and 5 cases in right side. Eight cases were received breast reconstruction by one-stage operation and 4 cases by two-stage operation. In one-stage operation cases, pathological diagnosis includes invasive ductal carcinoma in 4 cases and invasive lobular carcinoma in 4 cases. The disease duration ranged from 2 to 9 months (mean, 4.5 months). In two-stage operation cases, the time interval between mastectomy and breast reconstruction ranged from 12 to 70 months (mean, 37.4 months). The length of flap was 20-28 cm, the width of flap was 5.5-7.5 cm, the thickness of flap was 2.5-4.5 cm. The length of gracilis flap pedicle was 6.5-9.2 cm, the length of adductor magnus perforator flap pedicle was 7.5-10.4 cm. The weight of flap was 295-615 g.ResultsThe ischemia time of flap ranged from 95 to 230 minutes (mean, 135 minutes). All flaps were successfully survived. All incisions of recipient donor sites healed by first intention. All patients were followed up 7-14 months (mean, 9.5 months). The reconstructed breasts’ shape, texture, and elasticity were good and no flap contracture deformation happened. Only linear scar left in the donor sites, but the function of thighs was not affected. No local recurrence happened during follow-up.ConclusionWith appropriate patient selection and surgical technique, the combined transverse upper gracilis flap and adductor magnus perforator flap can be a valuable option as an alternative method for autologous breast reconstruction.
Objective To summarize the application progress of indocyanine green (ICG) angiography in breast reconstruction. Methods The literature about the application of ICG angiography in breast reconstruction was reviewed and analyzed, including its history, chemical composition, principles, usages, and attentions. Results ICG is a kind of fluorescent substance used in medical diagnosis and various surgical fields, especially in intraoperative vascular angiography. ICG angiography and SPY system are gradually applied in breast reconstruction, including both prosthesis/tissue expander reconstruction and autologous reconstruction. Compared to clinical judgment, portable Doppler devices, tissue oximetry, and fluorescein angiography, ICG angiography obviously has more benefits and usages. Conclusion ICG angiography can reveal the perfusion of flaps during the operation instantly and accurately, which refines the intraoperative strategy in order to decrease the incidence of flap-related complications. Besides, it has some economic benefits to some extent.
ObjectiveTo summarize the prevention and treatment strategies and their effects on lymphatic leakage following transoral endoscopic thyroid cancer lateral neck lymph node dissection. MethodsA retrospective review was conducted, we collected clinical data from 47 patients with papillary thyroid carcinoma who underwent transoral endoscopic thyroidectomy and lateral neck lymph node dissection at our hospital from January 2021 to May 2023. A stepwise sequential treatment plan was adopted for patients with postoperative lymphatic leakage: low-fat, low-protein diet, continuous strong negative pressure suction, subcutaneous injection of Group A streptococcus in the surgical cavity, and ligation of the thoracic duct or lymphatic vessels through a small incision. The effectiveness of the sequential treatment plan was summarized. ResultsOut of the 47 patients, lymphatic leakage occurred in 5 cases postoperatively. Patient No.1 was cured of lymphatic leakage after sequential treatments including pectoralis major muscle flap occlusion of the jugular venous angle, low-fat, low-protein diet, continuous strong negative pressure suction postoperatively, subcutaneous injection of Group A streptococcus in the surgical cavity, and finally ligation of the thoracic duct or lymphatic vessels through a small incision. Patient No.20 was conservatively cured of lymphatic leakage with an initial surgical procedure involving pectoralis major muscle flap occlusion of the jugular venous angle, low-fat, low-protein diet, continuous strong negative pressure suction postoperatively, and subcutaneous injection of Group A streptococcus in the surgical cavity. Patient No.28 recovered after only pectoralis major muscle flap occlusion of the jugular venous angle, low-fat, low-protein diet and continuous strong negative pressure suction postoperatively. Treatment process of patient No.30 was the same as Patient No.1, Patient No.36 was the same as Patient No.20. Through the stepwise sequential treatment measures, all 5 patients successfully recovered from lymphatic leakage; the postoperative hospital stay ranged from 3 to 17 days, with an average of 8.6 days. ConclusionsThe stepwise sequential treatment plan used in this study can effectively prevent and treat lymphatic leakage after transoral endoscopic thyroid cancer lateral neck lymph node dissection. Given the small sample size of this study, we believe that it is necessary to conduct long-term studies to confirm the durability and stability of these measures.
Objective To explore the effectiveness of pedicled chimeric thoracoacromial artery perforator (TAAP) flap as a reconstructive option for circular hypopharyngeal defects. Methods Between January 2013 and December 2014, the pedicled chimeric TAAP flap was used to repair oncologic circular hypopharyngeal defects in 8 patients, included 6 males and 2 females, with an average age of 57 years (range, 45-80 years). All patients were treated in other hospitals before and recurrence was noted. The duration between latest treatment and recurrence ranged from 3 to 28 months (mean, 16.5 months). According to Union for International Cancer Control (UICC) TNM staged, 3 cases were T2N1M0, 2 cases were T3N1M0, 1 case was T3N2M0, 2 cases were T4N1M0. After laryngectomy, the size of circular hypopharyngeal defect ranged from 9.0 cm×8.5 cm to 12.0 cm×10.5 cm. The size of TAAP flap ranged from 7.0 cm×4.0 cm to 9.5 cm×6.0 cm.The size of pectoralis major flap ranged from 9.0 cm×5.0 cm to 14.5 cm×6.0 cm.The donor sites were closed directly in all cases. Results Postoperatively all flaps survived smoothly, and all defects healed by first intention. No early complication was noted. The mean hospital stay period ranged from 12 to 22 days (mean, 14.5 days). All patients were followed up 12-45 months (mean, 18.7 months). Patients possessed good appearance of surgical sites. No recurrence, fistulas, stenosis/strictures, dehiscence, or swelling occurred. Only linear scars were left on the donor sites, and the pectoralis major muscle function was completely preserved in all patients. Conclusion Patients with high comorbidities may not be suitable candidates for free flap reconstruction, especially when the recipient vessels are affected from disease or radiotherapy. Pedicled chimeric TAAP flap is a good choice for the reconstruction of hypopharyngeal defects in such conditions.
ObjectiveTo investigate the influencing factors of flap-related complications and the economic benefits of intraoperative indocyanine green (ICG) angiography in the patients undergoing autologous breast reconstruction.MethodsBetween July 2013 and June 2018, the clinical data of 150 patients (152 breasts) who met the selection criteria after autologous breast reconstruction were analyzed retrospectively. Ten factors including age, body mass index, preoperative neoadjuvant chemotherapy (NC), chest radiation history, diabetes, abdominal operation history, chest wall reconstruction, reconstruction timing, flap type, intraoperative ICG angiography were analyzed by univariate analysis. Significant variables found in univariate analysis were used to perform backward multivariate logistic regression of flap related complications and local necrosis. According to the above multi factor analysis results, the patients were divided into 4 groups: ICG+NC group (group A), ICG+non-NC group (group B), non-ICG+NC group (group C), non-ICG+non-NC group (group D). The average extra costs of surgical treatment (including ICG imaging cost+cost of handling flap related complications) of each group was calculated.ResultsAll the 152 flaps survived. There were 33 flap-related complications, including 22 regional necrosis, 9 regional infection, 5 hematoma, 5 simple fat liquefaction, and 2 anasto-motic thrombosis. Univariate analysis showed that preoperative NC, flap type, and intraoperative ICG angiography had significant influence on the incidence of flap-related complications (P<0.05). Multivariate analysis showed that preoperative NC and non-ICG angiography were the risk factors of flap-related complications (P<0.05), and also the risk factors of regional flap necrosis (P<0.05). For patients who had NC, intraoperative ICG angiography could greatly save the average extra costs. The average extra costs in group A was 1 378 yuan less than that in group C. For the patients without NC, intraoperative ICG angiography would increase the average extra costs, which was 747 yuan in group B more than that in group D.ConclusionIn autologous breast reconstruction, ICG angiography can reduce the incidence of flap-related complications, especially the incidence of regional flap necrosis, while NC is the opposite. For patients without NC, ICG angiography is not cost-effective but still can be used if conditions permit. However, for those with NC, ICG angiography is cost-effective and recommended.