west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "aortic regurgitation" 19 results
  • Procedure specifications for transapical transcatheter aortic valve replacement

    Transcatheter aortic valve replacement (TAVR) techniques have been rapidly developed in recent years. Current guidelines and studies mainly focus on aortic stenosis patients treated by transfemoral approach, but they are not completely appropriate to patients with isolated aortic regurgitation or other patients who need transapical TAVR (TA-TAVR), which affects the standardized treatment of those patients. Therefore, our team pronounced the operational standards for TA-TAVR, based on fully reviewing the literatures worldwide, combined with the opinions of experts from 15 heart centers with rich experience in carrying out TA-TAVR in China. This standard aims to provide clinicians with standardized diagnosis and treatment principles of TA-TAVR and improve the quality of TA-TAVR in China.

    Release date:2023-03-24 03:15 Export PDF Favorites Scan
  • Simultaneous TAVI and McKeown for esophageal cancer with severe aortic regurgitation: A case report

    A 71-year-old male presented with esophageal cancer and severe aortic valve regurgitation. Treatment strategies for such patients are controversial. Considering the risks of cardiopulmonary bypass and potential esophageal cancer metastasis, we successfully performed transcatheter aortic valve implantation and minimally invasive three-incision thoracolaparoscopy combined with radical resection of esophageal cancer (McKeown) simultaneously in the elderly patient who did not require neoadjuvant treatment. This dual minimally invasive procedure took 6 hours and the patient recovered smoothly without any surgical complications.

    Release date:2025-01-21 11:07 Export PDF Favorites Scan
  • Clinical feasibility of transfemoral transcatheter aortic valve replacement in the treatment of high-risk pure aortic valve regurgitation

    Objective To assess early clinical safety and efficacy of transfemoral transcatheter aortic valve replacement (TF-TAVR) for pure aortic regurgitation (PAR). Methods The clinical data of PAR patients who underwent TAVR in Wuhan Asia Heart Hospital and Wuhan Asia General Hospital from January 2018 to October 2022 were retrospectively analyzed. Patients were divided into a TF-TAVR group and a transapical transcatheter aortic valve replacement (TA-TAVR) group. The clinical data of the patients were analyzed. Results A total of 54 patients were enrolled, including 34 males and 20 females with an average age of 74.43±6.87 years. The preoperative N-terminal pro-B-type natriuretic peptide level was lower [808.50 (143.50, 2 937.00) pg/mL vs. 2 245.00 (486.30, 7 177.50) pg/mL, P=0.015], and the left ventricular end-diastolic diameter (56.00±6.92 mm vs. 63.07±10.23 mm, P=0.005) and sinus junction diameter (32.47±4.41 mm vs. 37.65±8.08 mm, P=0.007) were smaller in the TF-TAVR group. There was no death in the two groups during the hospitalization. Only 1 new death within postoperative 1 month in the TF-TAVR group (cerebral hemorrhage). A total of 2 new deaths in the TF-TAVR group (1 patient of sudden cardiac death and 1 of multiple organ failure), and there was no death in the TA-TAVR group within postoperative 3 months. There was 1 new death in the TA-TAVR group (details unknown), and there was no death in the TF-TAVR group within postoperative 6 months. There was no statistical difference between the two groups in the all-cause mortality and the cumulative survival rate during the follow-up period (P>0.05). The incidence of high atrioventricular block was 36.0% in the TF-TAVR group and 10.3% in the TA-TAVR group (P=0.024). There were no significant differences between the two groups in the perivalvular leakage (≥moderate), valve in valve, a second valve implantation, valve migration, cerebrovascular events, major vascular complications, complete left bundle branch block, new permanent pacemaker implantation or transferring to surgery (P>0.05). However, the incidence rates of complete left bundle branch block and new permanent pacemaker implantation were higher in the TF-TAVR group, accounting for 56.0% and 40.0%, respectively. Conclusion TF-TAVR is a safe and feasible treatment for PAR patients, which is comparable to TA-TAVR in the early postoperative safety and efficacy.

    Release date:2024-08-02 10:43 Export PDF Favorites Scan
  • Mid-to-long term fate of neo-aortic root after arterial switch operation for Taussig-Bing anomaly: A retrospective study in a single center

    ObjectiveTo explore growth pattern of neo-aortic root as well as development of neo-aortic regurgitation after arterial switch operation (ASO) for Taussig-Bing anomaly. MethodsFrom 2002 to 2017, the patients who received ASO, and were discharged alive from Shanghai Children’s Medical Center and followed up for more than 3 years were retrospectively involved in this study. ResultsA total of 127 patients were enrolled. There were 98 (77.2%) males, the median age at ASO was 73.0 d and the average weight was 4.7 kg. Forty-five (35.4%) children were complicated with mild or mild-to-moderate pulmonary insufficiency (PI) before ASO. The average follow-up time was 7.0 years. During the follow-up, 14 (11.0%) children presented moderate or greater neo-aortic regurgitation (neo-AR). The diameter of neo-aortic annulus and sinus of Valsalva was beyond normal range during the entire follow-up. The average diameter of neo-aortic annulus was 18.0 mm at 5 years and 20.5 mm at 10 years. The average diameter of sinus of Valsalva was 25.9 mm at 5 years and 31.1 mm at 10 years. Neo-AR continued to develop over time. The diameter of children who developed moderate or greater neo-AR was constantly larger than that of children who did not (χ2=18.3, P<0.001). Preoperative mild or mild-to-moderate PI was an independent risk factor for the development of moderate or greater neo-AR during mid-to-long term follow-up (c-HR=3.46, P=0.03). ConclusionThe diameters of neo-aortic annulus and sinus of Valsalva of Taussig-Bing children who receive ASO repair continue to expand without normalization. The dilation of annulus correlates with the development of neo-AR. PI before ASO repair increases the risk of neo-AR development.

    Release date:2024-04-28 03:40 Export PDF Favorites Scan
  • Clinical effect of transcatheter aortic valve replacement on severe aortic regurgitation combined with severe mitral regurgitation: A single-center retrospective study

    ObjectiveTo determine the clinical efficacy of transcatheter aortic valve replacement (TAVR) for severe aortic regurgitation (AR) combined with severe mitral regurgitation (MR). MethodsThe clinical data of 13 patients who underwent TAVR due to severe AR combined with severe MR from March 2018 to September 2021 in our hospital were retrospectively analyzed, including 10 males and 3 females with a mean age of 72.54±2.35 years. The echocardiographic findings of all patients were compared preoperatively and postoperatively. ResultsSurgeries were performed successfully in all patients without intraoperative death or conversion to sternotomy. The operation time was 118.15±11.42 min, intraoperative blood loss was 100.00 (75.00, 250.00) mL, and the length of hospital stay after surgery was 9.00 (4.50, 11.00) d. The mean follow-up duration was 10.00 (6.50, 38.50) months, during which there were 2 patients with mild to moderate AR, 6 with mild AR, and 5 with no AR; meanwhile, severe MR decreased significantly (P=0.001) even without active intervention, including 4 mild to moderate MR and 9 mild MR patients. Compared to preoperative indexes, the left atrial diameter [46.00 (41.00, 52.50) mm vs. 35.00 (34.00, 41.00) mm, P<0.001], left ventricular end-systolic diameter [45.00 (36.00, 56.00) mm vs. 35.00 (28.00, 39.00) mm, P=0.002] and left ventricular end-diastolic diameter (62.62±2.40 mm vs. 51.08±2.49 mm, P<0.001) showed a decreasing trend during the follow-up. ConclusionIn selected patients with severe AR combined with severe MR, TAVR alone improves AR and combined MR at the same time.

    Release date:2022-08-25 08:52 Export PDF Favorites Scan
  • The clinical effect of a combined technical system for bicuspid aortic valves repair

    ObjectiveTo summarize the clinical result of a combined technical system for bicuspid aortic valve (BAV) repair. MethodsPatients who diagnosed as BAV and sever aortic regurgitation (AR) underwent a strategy of combined repair technics including annuloplasty, sinus plasty, leaflet plasty, sinus-tubular junction (STJ) plasty depending on anatomy pathological characteristics between October 2019 and January 2021 were enrolled. The clinical data of the patients were analyzed.ResultsA total of 17 patients were enrolled. There were 11 males and 6 females with an average age of 18-49 (32.4±13.6) years. Fifteen patients had typeⅠand 2 patients had typeⅡBAV according to Sievers classification. Annuloplasty was applicated in 13 patients, sinus plasty in 8 patients, leaflet plasty in 17 patients, and STJ plasty in 11 patients, respectively. The cardiopulmonary bypass (CPB) time was 95 (84, 135) min, aortic cross-clamping time was 68 (57, 112) min, and the ICU stay time was 17 (12, 25) h. After the operation, mild AR was presented in 14 patients, moderate AR in 1 patient and severe AR in 2 patients. The latter 3 patients underwent second operation under CPB, after then, 1 patient had mild AR and 2 patients had moderate AR. The follow-up time was 13.1±4.6 months. At the latest follow-up, 12 patients had mild AR and 5 patients had moderate AR, and no patient had reoperation. ConclusionA combined technical system for BAV repair can be used effectively and safely with an acceptable short and middle-term result.

    Release date:2023-07-10 04:06 Export PDF Favorites Scan
  • Transcatheter aortic valve replacement for aortic regurgitation complicated by Takayasu arteritis: A case report

    Patients with Takayasu arteritis combined with aortic valve disease often have a poor prognosis following surgical valve replacement, frequently encountering complications such as perivalvular leakage, valve detachment, and anastomotic aneurysm. This article presents a high-risk case wherein severe aortic valve insufficiency associated with Takayasu arteritis was successfully managed through transcatheter aortic valve implantation via the transapical approach. The patient had satisfactory valve function with no complications observed during the six-month postoperative follow-up period. This case provides a minimally invasive and feasible alternative for the clinical management of such high-risk patients.

    Release date: Export PDF Favorites Scan
  • Transapical transcatheter aortic valve replacement using Ken-Valve for pure severe aortic regurgitation: A case report

    Transcatheter aortic valve replacement (TAVR) has become the preferred treatment for severe aortic stenosis. The localization and anchor of many transcatheter heart valves available in the clinic today are dependent on the calcific aortic valve leaflet of patients. We reported here a successful case of transapical aortic valve implantation with Ken-Valve heart valve in an 82-year-old male patient with pure severe aortic regurgitation without native valve calcium. Postoperative follow-up (3 months after the surgery) showed that the cardiac function significantly improved. The echocardiography indicated that the Ken-Valve prosthesis worked well without perivalvular regurgitation. The short-term clinical effect was satisfactory. The Ken-Valve with three position anchors is proved to be suitable for the treatment of pure aortic regurgitation.

    Release date:2022-08-25 08:52 Export PDF Favorites Scan
  • Application of Ozaki operation in treatment of aortic regurgitation in children

    ObjectiveTo explore the early results of Ozaki operation in children with aortic regurgitation.MethodsWe retrospectively analyzed the clinical data of 15 patients with aortic regurgitation who received the Ozaki operation in our hospital from April 2017 to July 2019. There were 11 males and 4 females with an average operation age of 10.7±3.7 years. Besides preoperative evaluation, aortic regurgitation and cardiac function were evaluated on 1 day, 1 week, 1 month, 3 months, and 6-12 months after surgery.ResultsIn 14 (93.3%) patients , the aortic valve leaflets functioned well on 1 day, 1 month, 3 months, and 6-12 months, and the regurgitation grade was Ⅰ-Ⅱ, which was improved than before (P=0.001). The cardiac function of children recovered quickly after operation. There was no statistical difference in ejection fraction on 1 day, 1 month, 3 months, and 6-12 months after operation (P>0.05). No children died, and no other clinical event was found.ConclusionThe Ozaki technique of reconstructing a tricuspid aortic valve leaflet for the treatment of severe aortic regurgitation in children is effective in short term, and the persistence of its valve function remains to be determined in the long-term follow-up.

    Release date:2020-12-07 01:26 Export PDF Favorites Scan
  • Remodeling+Ring (modified Yacoub) technique for the treatment of bicuspid aortic valve regurgitation with ascending aortic aneurysm: A case report

    Patients with bicuspid aortic valve are often complicated with aortic dilatation. If the aortic valve is of good quality, aortic root replacement with aortic valve preservation is feasible. A 35-year-old male patient with bicuspid aortic regurgitation complicated with ascending aortic aneurysm underwent Remodeling+Ring (modified Yacoub) operation. Echocardiography showed that there was no aortic regurgitation on the 3rd day after operation, and the patient was discharged satisfactorily on the 6th day after operation. Remodeling+Ring surgery ensures the physiological movement of the aortic valve, solves the enlarged annulus, avoids the problems caused by valve replacement, and significantly improves the quality of life of patients, which is worth popularizing.

    Release date:2022-01-21 01:31 Export PDF Favorites Scan
2 pages Previous 1 2 Next

Format

Content