  • EFFECTIVENESS OF ARTHROSCOPIC TREATMENT OF ANTERIOR CRUCIATE LIGAMENT TIBIAL EMINENCE AVULSION FRACTURE WITH NON-ABSORBABLE SUTURE FIXATION COMBINED WITH MINI-PLATE

    Objective To evaluate the surgical techniques and effectiveness of arthroscopic treatment of anterior cruciate ligament (ACL) tibial eminence avulsion fracture with non-absorbable suture fixation combined with the mini-plate. Methods Between January 2009 and March 2012, 32 patients with ACL tibial eminence avulsion fractures were treated. There were 18 males and 14 females, aged 12-40 years (mean, 17.5 years). The injury causes included traffic accident injury in 15 cases, sport injury in 6 cases, and falling injury in 11 cases. The time from injury to operation ranged 7-18 days with an average of 9.5 days. Before operation, the results of Lachman test were all positive; the Lysholm score was 52.13 ± 4.22 and the International Knee Documentation Committee (IKDC) score was 44.82 ± 2.44. According to Meyers-McKeever classification criteria, there were 12 cases of type II and 20 cases of type III. After arthroscopic poking reduction of fracture, tibial eminence avulsion fractures were fixed with the Ethibond non-absorbable sutures bypass figure-of-eight tibial tunnel combined with the metacarpal and phalangeal mini-plate. Results Primary healing was obtained in all incisions; no joint infection or skin necrosis occurred after operation. All patients were followed up with an average time of 22.4 months (range, 12-50 months). The patients showed negative Lachman test at 12 weeks after operation. Except 3 patients having knee extension limitation at last follow-up, the knee extension range of motion (ROM) was normal in the other patients; the knee flexion ROM was normal in all patients. The Lysholm score and IKDC score were significantly improved to 94.19 ± 0.93 and 94.35 ± 1.22 at last follow-up, showing significant differences when compared with preoperative values (t=55.080, P=0.000; t=101.715, P=0.000). Conclusion The arthroscopic treatment of ACL tibial eminence avulsion fracture with Ethibond non-absorbable suture fixation combined with mini-plate is an effective procedure with the advantages of minimal trauma, reliable fixation, and satisfactory recovery of the knee joint function.

    Release date:2016-08-31 04:12 Export PDF Favorites Scan
  • Arthroscopic treatment of both anterior and posterior cruciate ligament tibial insertion avulsion fractures with suture and absorbable screw double fixation

    ObjectiveTo evaluate the effectiveness of arthroscopic suture and absorbable screw double fixation for both anterior and posterior cruciate ligament avulsion fractures of tibial insertions. MethodsBetween June 2006 and September 2013, 8 patients with anterior and posterior cruciate ligament avulsion fractures of the tibial eminence underwent arthroscopic treatment with suture and absorbable screw double fixation. There were 5 males and 3 females, with a mean age of 28.9 years (range, 18-43 years). The causes of injury included traffic accident in 5 cases and falling from height in 3 cases. The time from injury to operation was 3-10 days (mean, 6.2 days). The Lysholm knee score, International Knee Documentation Committee (IKDC) score, and Tegner rating scales were used to evaluated the knee function. ResultsPrimary healing of incision was obtained, without infection or deep vein thrombosis. The mean follow-up period was 42.4 months (range, 24 to 65 months). At 3 months after operation, X-ray films showed good reduction and healing of fracture. The anterior and posterior drawer tests were negative. The knee range of motion was normal (0-125°), and it recovered to preoperative level in 7 cases. The IKDC score, Tegner score, and Lysholm score were significantly improved to 90.4±5.2, 7.5±1.6, and 89.2±3.5 from preoperative 52.1±3.3, 3.3±1.0, and 51.9±3.5 respectively (t=-38.680, P=0.000; t=-39.520, P=0.000; t=-41.150, P=0.000). ConclusionA combined injury of anterior and posterior cruciate ligament avulsion fractures of tibial insertions is rare. Arthroscopic treatment with suture and absorbable screw double fixation is a useful technique to restore tibial avulsion injuries with well-documented radiographic healing, good clinical outcomes, and low complication rates.

    Release date: Export PDF Favorites Scan
  • Comparison of early effectiveness of arthroscopic suture bridge technique and conventional double tunnel suture technique in treatment of avulsion fracture of posterior cruciate ligament insertion

    ObjectiveTo compare the early effectiveness of arthroscopic suture bridge technique and conventional double tunnel suture technique in the treatment of avulsion fracture of posterior cruciate ligament (PCL) insertion.MethodsBetween June 2013 and December 2018, 62 patients with tibial avulsion fracture of PCL insertion that met the criteria were selected and randomly divided into trial group (using arthroscopic suture bridge technique) and control group (using conventional double tunnel suture technique), 31 cases in each group. There was no significant difference in gender, age, injured side, cause of injury, time from injury to operation, Meyers & McKeever classification, Kellgren-Lawrence classification, and preoperative knee range of motion, difference of posterior relaxation of bilateral knee joints, International Knee Documentation Committee (IKDC) score, and Lysholm score between the two groups (P>0.05). The operation time and IKDC score, Lysholm score, knee range of motion, the difference of posterior relaxation of bilateral knee joints (measured by KT-2000 under knee flexion of 90° and 30 lbs) were recorded and compared between the two groups before operation and at 3 and 12 months after operation.ResultsBoth groups successfully completed the operation, and the operation time of the trial group and the control group were (61.81±6.83) minutes and (80.42±4.22) minutes respectively, showing significant difference between the two groups (t=12.911, P=0.000). All the incisions healed by first intention, and there was no wound infection and other early postoperative related complications. All patients were followed up 13-18 months (mean, 14.6 months). The fractures in both groups healed at 3 months after operation. No knee pain, limited movement, or other complications occurred. At 3 and 12 months after operation, the IKDC score, Lysholm score, knee range of motion, and the difference of posterior relaxation of bilateral knee joints in both groups were significantly improved when compared with preoperative ones, and further improved at 12 months after operation when compared with at 3 months after operation (P<0.05). At each time point after operation, the above indexes and the grade of the difference of posterior relaxation of bilateral knee joints in the trial group were significantly better than those in the control group (P<0.05).ConclusionArthroscopic suture bridge technique in the treatment avulsion fracture of PCL insertion is simple and reliable, which can significantly improve the function and stability of the knee joint and obtain satisfactory early effectiveness.

    Release date:2021-07-29 05:02 Export PDF Favorites Scan
  • ARTHROSCOPIC REDUCTION AND FIXATION OF TIBIAL INTERCONDYLAR EMINENCE AVULSION FRACTURES USING NONABSORBABLE SUTURE WITH NECKWEAR KNOT LOOP LIGATURE

    Objective To investigate the effectiveness of percutaneous reduction by leverage and fixation using nonabsorbable suture with neckwear knot loop l igature to treat tibial intercondylar eminence avulsion fractures under the arthroscope. Methods Between February 2003 and December 2008, 28 patients with tibial intercondylar eminence avulsion fractures were treated, including 16 left knees and 12 right knees. There were 15 males and 13 females with an average age of19.5 years (range, 14-45 years). The injury causes included traffic accident injury in 11 cases, sport injury in 10 cases, and sprain injury in 7 cases. Based on Meyers-McKeever classification, there were 18 cases of type III and 10 cases of type IV. The X-ray films showed the tibial intercondylar eminence displaced fracture. The mean time between trauma and operation was 7 days (range, 4-12 days). All patients were treated surgically with an arthroscopically assisted reduction by leverage and fixation using 5-0 Ethibond suture with neckwear knot loop l igature. Results All incisions healed by first intention without infection or injuries of nerves and vessels. Twenty-eight patients were followed up 26 months on average (range, 12-66 months). The X-ray films showed fracture heal ing within 9-13 weeks (mean, 11 weeks). At last follow-up, all patients were able to return to their pre-injury activity and daily l ife. The knee joint was stable with no l imp or impingement of intercondylar fossa. The knee joint range of motion was 0-130°. The results of Lachman and anterior drawer tests were negative in all patients. At last follow-up, the Lysholm score was 93.5 ± 2.5, showing significant difference when compared with the preoperative one (29.0±2.2, t=53.000, P=0.000). Conclusion Percutaneous reduction by leverage and fixation using nonabsorbable suture with neckwear knot loop l igature is minimally invasive and satisfied reduction and fixation in treating the tibial intercondylar eminence avulsion fracture under the arthroscope, so it is benefit for early functional exercises, and can achieve excellent results.

    Release date:2016-08-31 05:44 Export PDF Favorites Scan
  • TREATMENT OF ULNAR COLLATERAL LIGAMENT AVULSION FRACTURE OF THUMB METACARP-OPHALANGEAL JOINT USING A COMBINATION OF Kirschner WIRE AND SILK TENSION BAND

    Objective To investigate the effectiveness of Kirschner wire combined with silk tension band in the treatment of ulnar collateral ligament avulsion fracture of the thumb metacarpophalangeal joint. Methods Between September 2008 and October 2011, 14 patients with ulnar collateral ligament avulsion fracture of the thumb metacarpophalangeal joint were treated using a combination of Kirschner wire and silk tension band. There were 8 males and 6 females, aged 23-55 years (mean, 40.8 years). The causes of injury were machinery twist injury in 5 cases, manual twist injury in 4 cases, falling in 4 cases, sports injury in 1 case. The time from injury to operation was 2 hours-14 days. All the patients presented pain over the ulnar aspect of the metacarpophalangeal joint of the thumb, limitation of motion, and joint instability with pinch and grip. The lateral stress testing of the metacarpophalangeal joint was positive. Function training was given at 2 weeks after operation. Results All incisions healed by first intention. The lateral stress testing of the metacarpophalangeal joint was negative. All the patients were followed up 6-18 months (mean, 13.1 months). The X-ray films showed good fracture reduction and healing with an average time of 7 weeks (range, 4-10 weeks). At last follow-up, the thumbs had stable flexion and extension of the metacarpophalangeal joint, normal opposition function and grip and pinch strengths. According to Saetta et al. criteria for functional assessment, the results were excellent in 11 cases and good in 3 cases; the excellent and good rate was 100%. Conclusion It is an easy and simple method to treat ulnar collateral ligament avulsion fracture of the thumb metacarpophalangeal joint using Kirschner wire combined with silk tension band, which can meet the good finger function.

    Release date:2016-08-31 04:22 Export PDF Favorites Scan
  • Effectiveness of multidirectionally three-dimensional steel wire ring sleeve fixation in treatment of inferior patellar pole avulsion fractures

    ObjectiveTo explore the method and effectiveness of multidirectionally three-dimensional steel wire ring sleeve fixation in the treatment of inferior patellar pole avulsion fractures.MethodsBetweern January 2015 and January 2019, 22 patients with inferior patellar pole avulsion fractures were admitted and treated. There were 12 males and 10 females. The age ranged from 20 to 69 years, with an average age of 39.4 years. The causes of injury included 9 cases of traffic accident and 13 cases of falling. All of them were unilateral closed injury of knee joint, including 7 cases of skin contusion around patella. Preoperative range of motion of the affected knee was (20.82±7.16)° (range, 10°-35°). The time from injury to operation ranged from 3 to 12 days, with an average of 5.9 days. During the operation, the inferior patellar avulsion fracture was reduced with forceps; the patella was circumferentially ligated through the distal bone surface of the fracture with 0.8 mm diameter steel wire; then 3 longitudinal bone tunnels were made in the upper patella, respectively. The 0.8 mm diameter steel wire passed through the bone tunnel, and the longitudinal ring was attached to the ring to fix the upper and inferior patellar fracture. Tighten the transverse and longitudinal rings with No.2 tendon suture line, then longitudinally ringed and sutured to strengthen the patella. The knee range of motion, fracture healing time, and complications were recorded. The functional recovery of the knee joint was evaluated by Böstman score.ResultsAll incisions healed by first intention, and no incision related complications occurred. All the 22 patients were followed up 13 months to 5 years with an average of 26.7 months. The fracture healing time was 9-12 weeks (mean, 10.9 weeks). At last follow-up, the knee range of motion was (129.77±2.35)° (range, 126°-135°), showing significant difference when compared with preoperative one (t=−67.022, P=0.000). The Böstman score ranged from 31 to 36, with an average of 34.3. No reduction loss, fracture of steel wire, failure of internal fixation, and other complications occurred during follow-up.ConclusionMultidirectionally three-dimensional steel wire ring sleeve fixation in the treatment of inferior patellar pole avulsion fractures has the advantages of reliable fixation, early functional recovery, and fewer complications, so the effectiveness is satisfactory.

    Release date:2021-02-24 05:33 Export PDF Favorites Scan
  • ARTHROSCOPIC TREATMENT FOR TIBIAL EMINENCE AVULSION FRACTURE USING ABSORBABLE DOUBLE SUTURE ANCHORS

    Objective To investigate the outcomes of arthroscopic reduction and internal fixation of tibial eminence avulsion fracture using absorbable double suture anchors. Methods Between February 2007 and August 2009, 18 patients with tibial eminence avulsion fracture were treated with arthroscopic reduction and fixation using absorbable doublensuture anchors. There were 12 males and 6 females with an average age of 30.6 years (range, 17-48 years). The disease causes were traffic accident injury in 4 cases, sport injury in 8 cases, and fall ing from height injury in 6 cases; the locations were left side in 7 cases and right side in 11 cases. The results of the anterior drawer test and Lachman test were positive. According to Meyers-McKeever classification, 10 cases were rated as type II, 7 as type III, and 1 as type IV fractures. The time from injury to treatment was 6-20 days (mean, 10.2 days). Results Incision healed primarily. All the patients were followed up 29.1 months (range, 13-43 months). The X-ray films showed good reduction of fracture immediately after operation and fracture heal ing at 3 months. At the last follow-up, the range of motion of knee was 0-130°. The results of Lachman test and anterior drawer test were negative in 18 cases and 16 cases, repectively; and the results of anterior drawer test were weakly positive in 2 cases. The mean Lysholm score was significantly improved from 53.9 ± 6.7 preoperatively to 91.6 ± 4.2 postoperatively (t=22.100, P=0.000). The Inter national knee Documentation Commitee (IKDC) 2000 subject score improved from 58.1 ± 3.7 preoperatively to 92.8 ± 5.9 postoperatively (t=20.700, P=0.000). Conclusion Arthroscopic treatment using absorbable double suture anchors for tibial eminence avulsion fracture can provide satisfactory reduction, stable fixation, and good heal ing of the avulsed fragment, which is a minimally-invasive, simple, and effective treatment for patients with tibial eminence avulsion fracture.

    Release date:2016-08-31 05:42 Export PDF Favorites Scan
  • CLINICAL OBSERVATION OF STELLATED PLATE FIXATION OF OLECRANAL AVULSION FRACTURE

    ObjectiveTo evaluate the clinical outcome of stellated plate fixation of olecranal avulsion fracture. MethodsA retrospective analysis was made on the clinical data from 24 cases of olecranal avulsion fracture treated with stellated plate between April 2007 and April 2012. There were 13 males and 11 females, with an average age of 32 years (range, 18-65 years). The causes of injury included falling injury (14 cases), sports injury (7 cases), and machine injury (3 cases). The left elbow was involved in 4 cases and the right side in 20 cases. The average disease duration was 11 hours (range, 3 hours-2 days). According to Colton's classification criteria, all cases were classified as type Ⅱ A (avulsion fracture). One case had supracondylar humeral avulsion fracture, and 15 cases had triceps tendon tears. ResultsAll the cases obtained healing of incision by first intention, without infection and ulnar nerve injury. The average follow-up period was 24 months (range, 18-48 months). All fractures healed after 6-10 weeks (mean, 7 weeks). According to Morrey's elbow performance score, the results were excellent in 17 cases, good in 4 cases, and fair in 3 cases, with an excellent and good rate of 87.5%. There was no significant difference in the elbow range of motion (ROM) between the injured side (136.0±16.2)° and normal side (143.1±2.9)° (t=2.007, P=0.052). The ROM of normal elbow was significantly larger than that of the injured side in 3 patients who achieved fair results (t=2.820, P=0.048), but no significant difference was found in patients who achieved excellent and good results (P>0.05). ConclusionThe stellated plate has good clinical outcome in treatment of olecranal avulsion fracture, which has advantages of simple operation, firm fixation, and early functional exercise.

    Release date: Export PDF Favorites Scan
  • Early effectiveness of arthroscopic three-point suture technique in treatment of anterior cruciate ligament tibial eminence avulsion fracture

    Objective To investigate the early effectiveness of three-point suture technique in treatment of anterior cruciate ligament (ACL) tibial eminence avulsion fracture by arthroscopy. Methods Between January 2016 and December 2017, 12 patients with ACL tibial eminence avulsion fractures underwent arthroscopic fixation of avulsion fractures with Ethibon suture using three-point suture technique. There were 9 males and 3 females, with an average of 36.4 years (range, 18-50 years). The fracture caused by traffic accident in 10 cases and sports in 2 cases. Among them, 1 patient was old fracture and 11 was fresh fracture. According to the modified Meyers-McKeever classification criteria, the fractures were rated as type Ⅲ in 7 cases and type Ⅳ in 5 cases. There were 2 cases of medial collateral ligament injury and medial meniscus injury. The preoperative International Knee Documentation Committee (IKDC) score was 37.9±4.7 and Lysholm score was 46.0±3.7. Results All operations completed smoothly. The operation time was 45-70 minutes (mean, 61.3 minutes). The incisions healed by first intention in all patients. The hospitalization stays ranged from 4 to 9 days (mean, 5 days). All patients were followed up 3-20 months (mean, 9.3 months). The anterior drawer test, Lachman test, and axis shift test in all patients were negative after operation. At last follow-up, the IKDC score was 89.7±2.5 and Lysholm score was 90.2±1.9, which were significantly higher than those before operation (t=–30.94, P=0.00; t=–33.03, P=0.00). At last follow-up, the X-ray films showed 9 cases of fracture anatomical reduction and 3 cases of almost anatomical reduction, and 12 cases of fracture healing. Conclusion For ACL tibial eminence avulsion fracture, arthroscopic three-point suture technique can effectively restore the stability of knee joint and obtain satisfactory early effectiveness.

    Release date:2019-06-20 03:12 Export PDF Favorites Scan
  • Clinical treatment of dorsal avulsion fracture of the capitellum combined with medial or posterior medial dislocation of the elbow joint

    ObjectiveTo analyze the possible injury mechanisms in patients with dorsal avulsion fracture of the capitellum combined with medial or posterior medial dislocation of the elbow joint, and to discuss their treatment and prognosis. Methods Retrospective analysis was made on the clinical data of 4 patients with dorsal avulsion fracture of the capitellum combined with medial or posterior medial dislocation of the elbow joint admitted between September 2014 and September 2020, including 3 males and 1 female with an average age of 20.7 years (range, 13-32 years). There were 2 cases of dorsal avulsion fracture of the capitellum combined with medial dislocation of the elbow joint and 2 cases of dorsal avulsion fracture of the capitellum and anterior medial fracture of the coronoid process combined with posterior medial subluxation of the elbow joint. Closed reduction was performed in 3 patients with fresh fracture combined with dislocation, then 2 cases were fixed with tension band and 1 case was fixed with tension band combined with Acumed coronoid anatomic plate. And in patient with old fracture nonunion, the coronoid process was fixed with 1 screw, then the humeral sclerotic bone mass was removed, and finally the lateral collateral ligament was repaired and a hinged external fixator was added. Results All the incisions healed by first intention without early complications such as infection or peripheral nerve injury. The 4 patients were followed up 13-30 months (mean, 20.8 months). The fractures all healed with a healing time of 70-90 days (mean, 79.5 days). At 6 months after operation, heterotopic ossification was seen in the posterior aspect of the right elbow joint in 1 case, and the alkaline phosphatase level was normal (67 U/L); the tension band was removed to clear the heterotopic ossification and the elbow joint was released. The rest of the patients had no heterotopic ossification. At last follow-up, all patients had good functional recovery of the elbow joint, with a Mayo score of 85-100 (mean, 92.5), and the excellent and good rate was 100%. The elbow flexion range of motion was 120°-135°, the extension range of motion was 10°-20°, and the pronation and supination range of motion were all 75°-85°. Conclusion Dorsal avulsion fractures of the capitellum combined with medial or posterior medial dislocation of the elbow may be due to simple varus stress. If an anteromedial coronoid facet fracture also occurs, it may be for the varus posteromedial rotatory instability, which is the opposite mechanism to that of an Osborne-Cotterill lesion. For fresh dorsal avulsion fractures of the capitellum, tension band fixation can be used with good results.

    Release date:2022-02-25 03:10 Export PDF Favorites Scan