west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "chocardiography" 88 results
  • The influence of autologous bone mesenchymal stem cells on myocardial structure and cardiac function after being implantated into acute infarcted myocardium

    Objective To study the influence of autologous bone mesenchymal stem cells (BMSCs) on myocardial structure and cardiac function after being implantated into acute infarcted myocardial site. Methods Bone marrow was aspirated from the posterosuperior iliac spine of Guizhou Xiang swine. After being isolated, cultured and co cultured with 5 azacytidine, either autologous BMSCs (total cells 2×10 6, experimental group, n =12), or a comparable volume of culture medium (control group, n =12), was injected into the left anterior descending(LAD) branch of coronary artery just distal to the ligation site of the LAD. The same volume of BMSCs or culture medium was injected into several spots in the infarcted myocardium. Echocardiographic measurements were performed three or six weeks after implantation to assess the myocardial structure and cardiac function. Results Left ventricular function, including eject fraction(EF), fractional shortening and wall thickening, were higher in experimental group when compared with control group. The thickness of the ventricular wall and septum was also found increased while the left ventricular chamber size was smaller in experimental group. Conclusion Implantation of BMSCs into the infarcted myocardium is believed to attenuate the remodeling process, inhibit the extent of wall thinning and dilatation of the ventricular chamber. BMSCs implantation may also improve the contractile ability of the myocardium and cardiac function.

    Release date:2016-08-30 06:27 Export PDF Favorites Scan
  • Analysis of Failure of Perventricular Device Closure of Ventricular Septal Defect

    摘要:目的:分析微创外科室间隔缺损(ventricular septal defect,VSD)封堵失败原因,以期提高术前超声心动图筛查水平。方法:回顾性分析25例微创外科VSD封堵失败改行修补术病例,对比超声表现及手术所见,归纳总结产生并发症的原因。结果:残余分流与VSD假性膜部瘤右室面具有多个出口和低估VSD大小密切相关;VSD合并主动脉瓣右冠瓣脱垂是主动脉瓣反流的主要原因;封堵器移位与低估VSD大小且使用偏心封堵器有关;原有三尖瓣反流加重和发生Ⅲ度房室传导阻滞VSD均位于隔瓣下方;封堵失败组较封堵成功组缺损偏大,差异具有统计学意义(Plt;0.05)。结论:超声心动图对VSD及其毗邻结构的细致评估,有助于严格适应证,提高手术成功率。 Abstract: Objective:To analyze the failure of perventricular closure of ventricular septal defect (VSD), in order to improve the preoperative echocardiography examination. Methods: Twentyfive cases underwent surgical repair after failure of perventricular closure of VSD were included in this study. With combination of echocardiographic and surgical findings, retrospective analysis of the failure of perventricular closure of VSD were attempted to summarize the cause of complications.Results: Residual ventricular communication was due to underestimation of size of VSD and pseudomembranous aneurysm resulting in multiple outlets of VSD on the right ventricle side; preoperative prolapse of rightcoronary cusp was the main reason for mild or greater than mild aortic valve regurgitation after eccentric device closure of VSD; Underestimation of the size of VSD and using eccentric occluder device were responsible for the displacement of VSD occluder device. Postoperative aggravated tricuspid regurgitation and Ⅲ°atrialventricular block (AVB) were attributed to VSDs located under the septal leaflet of tricuspid valve. The size of VSD in group of failed perventricular device closure of VSD was larger than that in group of successful device closure of VSD,and the difference was significant(Plt;0.05). Conclusion: Echocardiography vividly reveals VSD and adjacent structures, which should be used in accessing the anomaly and defect and formulating surgical plans to reduce surgical morbidity and mortality.

    Release date:2016-09-08 10:12 Export PDF Favorites Scan
  • Realtime Threedimensional Echocardiography Evaluation in Changes of Left Ventricular Regional Systolic Function after Surgical Treatment of Left Ventricular Aneurysm

    Abstract: Objective To investigate changes of left ventricularregional systolic function after surgical treatment of left ventricular aneurysm (LVA) by realtime threedimensional echocardiography (RT-3DE). Methods From February 2009 to February 2010, 14 consecutive patients who were diagnosed to have coronary artery diseases with LVA underwent surgical repair and coronary artery bypass grafting (LVA group) in our hospital. All patients of the LVA group were followed up for a mean period of 4 months. Twodimensional echocardiography (2DE) and RT-3DE were performed before operation and during the follow-up. Left ventricular regional ejection fraction (EF) was acquired by Qlab software analysis. At the same time, 12 healthy persons were included as controls (control group). Statistical analyses were carried out to compare left ventricular regional EF between the LVA group (before operation and 4 months after operation) and the control group. Results Contrary to the control group, preoperative regional EF of the LVA group increased from apex to base. In addition to the inferior basal segment, lateralinferior basal segment and anteriorinferior basal segment, regional EF in the remaining 14 segments were significantly lower than that of the control group (P<0.05). At postoperative followup, regional EF recovered the increase from base to apex, and there was no significant difference between anteriorinferior segment and lateral segment regional EF of the LVA group and those of the control group (P>0.05), while regional EF of other segments in the LVA group was lower than that in the control group (P<0.05). Conclusion RT-3DE is an effective method to assess left ventricular regional systolic function in patients with LVA. After LVA repair and coronary artery bypass grafting, regional systolic function will restore to the normal direction of progressive increase, and some nonaneurysm segments systolic function will go back to normal.

    Release date:2016-08-30 05:57 Export PDF Favorites Scan
  • Study on Downstream Flow Field Uniformity of Aortic Stenosis by Using Pulse Wave Doppler Echocardiography

    ObjectiveBy comparing the difference between different stenosed degree of aortic valve in flow field uniformity and turbulent shear stress (TSS), to explore the relation between flow field uniformity and different stenosed degree of aortic valve, and probe the clinical value for deciding the operation timing, and analyze the possible role of TSS in the progress of the disease.MethodsThe flow field uniformity values and TSS in parasternal long axis plane and apical five cavity plane on each point were measured and calculated by pulse wave Doppler echocardiography technique for 33 patients with different stenosed degree of aortic valve.ResultsThere were significant difference between the different stenosed degree of aortic valve in maximal velocity difference(ΔV max )and TSS( P lt;0.05, 0.01). The more severe the aortic stenosis was, the worse the flow field uniformity was, the lower the TSS was.ConclusionsThere are significant difference between the patients of different stenosed degree of aortic valve in flow field uniformity. Flow field uniformity has important value in classifying the degree of aortic stenosis and deciding the timing of operation. The more severe the aortic stenosis is ,the lower TSS is. It can be thought that low TSS distribution has important role in pathological process of constriction in cardiovascular system diseases.

    Release date:2016-08-30 06:24 Export PDF Favorites Scan
  • Real-time Three-dimensional Echocardiography (RT-3DE) Application in Evaluation of Left Ventricular Motion in Patients with Rheumatic Mitral Stenosis

    ObjectiveTo evaluate myocardial segmental motion function in left ventricular of patients with rheumatic mitral stenosis by using the technology of real-time three-dimensional echocardiography (RT-3DE). MethodsWe retrospectively analyzed the clinical data of 14 patients with rheumatic mitral stenosis between October and November 2014 in our hospital as a trial group. There were 4 males and 10 females with a mean age of 50.9±9.0 years ranging from 34 to 64 years. We chose 11 healthy individuals as a control group. There were 7 males and 4 females with a mean age of 49.5±9.7 years ranging from 32 to 67 years. Both the two groups were subjected to myocardial performance evaluation using two-dimensional echocardiography (2DE) and real-time three-dimensional echocardiography (RT-3DE) to examine the left ventricular ejection fraction (LVEF), left ventricular end-diastolic volume (LVEDV), left ventricular end systolic volume (LVESV), longitudinal strain, circumferential strain, area strain, and lateral strain of each left ventricular myocardial segments. Result RT-3DE detected that the trial group had significantly lower values of LVEF, LVEDV and LVESV than those of the control group (P < 0.05). RT-3DE also revealed that the trial group had a significantly weaker longitudinal strain than the control group (P < 0.05). ConclusionRT-3DE is an accurate technology for assessing myocardial motion and function in patients with rheumatic mitral valve disease.

    Release date: Export PDF Favorites Scan
  • Minimally Invasive Transthoracic Closure of Perimembranous Ventricular Septal Defect without Cardiopulmonary Bypass

    Abstract: Objective To introduce a new technique: transthoracic closure of perimembranous ventricular septal defect (VSD) without cardiopulmonary bypass (CPB) under transesophageal echocardiography (TEE)guidance, and summarize the clinical experiences and midterm followup results. Methods A total of 136 patients with perimembranous VSD, 3 months to 15 years averaging 1.8 years, underwent transthoracic device closure. The weight of these patients ranged from 4.0 to 26.0 kg with an average weight of 12.7 kg. The diameter of their VSD ranged from 3 to 12 mm averaging 5.1 mm. A small transthoracic incision (34 cm incision by inferior sternotomy or 23 cm transverse incision in the third intercostal space) was made and the best location for right ventricular puncture was chosen and the delivery pathway was established under TEE guidance. Proper devices were delivered and then deployed to close the defect. Patients were followed up closely with a standard protocol, arranged for echocardiography, electrocardiogram and chest Xray film. Results In all the cases, 131 cases of VSD (96.3%) were successfully closed. The procedure time was less than 90 minutes and the implanting time was 5.42 minutes (16.3±5.7 min). Symmetrical devices were implanted into 89(67.9%) of the 131 patients and the other 42 patients (32.1%) were closed with asymmetrical ones. The result of TEE soon after operation showed that 3 patients had tiny residual shunt, 4 had new trivial and mild tricuspid regurgitation (TR). However, no TR worsening, aortic regurgitation (AR), complete atrioventricular heart block, or left or right outflow tract obstruction was detected in all patients. One patient 〖CM(159mm〗with transient atrioventricular block restored to sinus rhythm after 3 days of medical treatment. Five cases (3.7%) were converted to conventional open heart repair during the operation. Followup was done to all the patients for a period ranged from 6 months to 30 months (18.3±6.6 months). Tiny residual shunt in the 3 cases mentioned above vanished during the followup period. No new TR, AR, hemolysis, thrombosis, dislocation of the devices, or outflow stenosis was detected postoperatively. The tiny incision caused less psychologic depression. Conclusion Minimally invasive transthoracic device closure of VSD without CPB is a simple, effective and safe intervention under guidance of TEE for most of perimembranous VSD patients. The short and midterm clinical outcomes are promising. Longterm followup is indispensable.

    Release date:2016-08-30 06:02 Export PDF Favorites Scan
  • Analysis of dominant views in ultrasound examination of common congenital heart diseases in children

    Objective To explore the dominant views with positive results when performing echocardiography on common congenital heart diseases (CHD) in children using the "Seven-Step Screening Method for Pediatric Echocardiography". MethodsThe echocardiographic data of children with atrial septal defect, patent foramen ovale, ventricular septal defect, and patent ductus arteriosus were collected from September 2021 to February 2022. The disease type distribution, view distribution, and the dominant view distribution were analyzed. Dominant view refered to the view with a high ratio of positive result images per view to the total image in each disease. Results A total of 8 353 images of 1 633 children with common CHD were collected. There were 813 males and 820 females at age of 0-7 years. Including 3 613 images in 701 patients with atrial septal defect, 1 178 images in 206 patients with patent foramen ovale, 2 857 images in 576 patients with ventricular septal defect, and 705 images in 150 patients with patent ductus arteriosus. The dominant views of atrial septal defect were subxiphoid 2-chamber view (92.96%), subxiphoid 4-chamber view (85.61%), parasternal 4-chamber view (62.07%), and parasternal short-axis view (38.50%). The dominant views of patent foramen ovale were subxiphoid 2-chamber view (82.69%) and subxiphoid 4-chamber view (65.41%). The dominant views of ventricular septal defect were parasternal 5-chamber view (79.73%), parasternal short-axis view (79.41%), parasternal 4-chamber view (58.18%), and parasternal long-axis view (51.11%). The dominant view of patent ductus arteriosus were parasternal short-axis view (98.80%). Conclusions The analysis of the lesion key areas of common CHD showed that there were 4 dominant views for atrial septal defect and ventricular septal defect, 2 for patent foramen ovale, and only 1 for patent ductus arteriosus. Clarifying the dominant views of common CHD were conducive to rapid and accurate diagnosis of diseases, clinical, teaching and scientific research.

    Release date: Export PDF Favorites Scan
  • Echocardiography Expression in Heart Valve Damage with Rheumatoid Arthritis

    【摘要】随着超声心动图的普及与发展,无症状性类风湿性关节炎心脏瓣膜改变的检出率逐渐增多。临床应重视类风湿性关节炎心脏瓣膜损害以及超声心动图在这类疾病中的诊断价值,以期改善患者预后。【Abstract】 Objective More and more cardiac valve changes are detected in asymptomatic patients with rheumatoid arthritis by echocardiography. It is essential to pay attention to the clinical features of heart valves damage and the diagnostic value of echocardiography on that in order to improve the prognosis of patients.

    Release date:2016-09-08 09:45 Export PDF Favorites Scan
  • Evaluation of the effectiveness of transcatheter closure of fenestrated atrial septal defect via femoral vein under ultrasound guidance

    Objective To introduce the application of transcatheter closure of multi-fenestrated atrial septal defect (ASD) via femoral vein under ultrasound guidance with amplatzer cribriform occluder (ACO) and atrial septal defect occluder (ASDO), as well as to assess its feasibility, effectiveness and safety. Methods The clinical data of 48 patients with fenestrated ASD occluded via femoral vein under ultrasound guidance from December 2015 to May 2018 in our hospital were retrospectively analyzed, including 17 males and 31 females, aged 10 months to 51 years, an average of 11.50±13.86 years, and weighting 6-79 (27.00±20.14) kg. Among 48 patients with fenestrated ASD, 12 patients had double-foramen and 13 atrial septal aneurysm combined with defects and 23 multi-foramen. All patients underwent transthoracic echocardiography (TTE) or transesophageal echocardiography (TEE) to complete the closure of fenestrated ASD. Ultrasound, electrocardiogram and chest X-ray were reviewed the next day after surgery to evaluate the curative effect. Results Forty-eight patients with ASD were treated with 49 occluders, due to one patient with two occluders. There were 29 ASDO (8-26 mm) and 20 ACO (18-34 mm). During the operation, TTE/TEE examination showed that 48 patients were completely occluded, 13 patients showed fine bundle shunt in the unreleased push notification rod, and 9 patients had fine bundle shunt after the release of push notification rod. Fine bundle shunt was found in 8 patients 24 hours after operation, and microshunt was found in 3 patients 1 year after operation. All the patients were followed up. The occluder position was good. The right heart was reduced in different degrees, and the X-ray showed that the pulmonary blood was reduced in different degrees. No arrhythmia was found by electrocardiogram after operation. Conclusion It is a safe and effective method to use ACO and ASDO to occlude ASD through femoral approach under ultrasound guidance.

    Release date:2019-08-12 03:01 Export PDF Favorites Scan
  • Observation of left atrial hydrodynamic change in patients with rheumatic mitral stenosis

    Objective To investigate the correlation between the left atrial hydrodynamic change and atrial fibrillation (AF) in the patients with rheumatic mitral stenosis. Methods According to cardiac rhythm before operation, 49 patients with rheumatic mitral stenosis accompanying chronic AF were divided into two groups,group A: AF, 25 cases; group B: sinus rhythm, 24 cases. Control group : 29 healthy volunteers were examined. By using echocardiography, left atrial hydrodynamics were tested, and repeated 6-8 months after the operation. Results Left atrial stress (LAS), left atriala area (LAA) and left atrial volume(LAV) in group A after operation was much lower than before operation, LAS after operation in group B was also lower than before operation(Plt;0.01). Before operation, LAS in group A was significantly lower than that in group B, LAA and LAVwere larger. After operation, LAA and LAV in group A were significantly larger than those in group B(Plt;0.01). LAS, LAA and LAV in group A and group B before and after operation were higher than those in control group. Conclusion Left atrial hydrodynamic enviroment in patients with mitral stenosis has not reached normal even after valve replacement, LAS may be an important factor of causing AF.

    Release date:2016-08-30 06:27 Export PDF Favorites Scan
9 pages Previous 1 2 3 ... 9 Next

Format

Content