west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "dislocation" 144 results
  • FUNCTIONAL RECONSTRUCTION OF CONGENITAL DISLOCATION OF HIP IN OLD-AGED CHILDREN

    Twelve cases (13 hips) of congenital dislocation of hip (CDH)in a group above the age of six were treated by Chiari pelvic osteotomy from Jan. 1991 to Dec. 1992. The results following operative treatment rated as good in 85 percents according to the clinical and radiologic examinations. The indications, and the results with the operation as the functional reconstuction of the hip concerned were discussed.

    Release date:2016-09-01 11:34 Export PDF Favorites Scan
  • REPAIR OF ACROMIO-CLAVICULAR DISLOCATION BY TRANSPOSITION OF SHORT HEAD OF BICEPS BRACHII MUSCLE

    The short head of the biceps brachii muscle was removed from its origin with a thin piece of bone from the coronoid process and was transposed to the dislocated clavicle. From the action of muscle contraction from the biceps brachii muscle, the dislocated clavicle would be pulled downward. This method of repair was satisfactory in4 cases of acromioclavicular dislocation. Results obtained from the follow-up, there was no recurrence of dislocation, and the function and muscle power of the shoulder were completely normal.

    Release date:2016-09-01 11:38 Export PDF Favorites Scan
  • Modified Hueter direct anterior approach for treatment of Pipkin type Ⅰ and Ⅱ femoral head fractures

    ObjectiveTo discuss the effectiveness of the modified Hueter direct anterior approach in treatment of Pipkin typeⅠ and Ⅱ femoral head fractures.MethodsBetween September 2014 and May 2016, 12 patients with Pipkin type Ⅰ and Ⅱ femoral head fractures were treated with the modified Hueter direct anterior approach. There were 8 males and 4 females, aged from 32 to 60 years (mean, 40.2 years). The disease causes included traffic accident injury in 9 cases and falling from height injury in 3 cases. According to Pipkin typing, 8 cases were rated as type Ⅰ and 4 cases as type Ⅱ. The interval of injury and admission was 2-28 hours (mean, 7.2 hours). Reduction was performed in all patients within 6 hours after admission, and then bone traction was given. The operation was performed in 3-7 days (mean, 4.3 days) after redution. The modified Hueter direct anterior approach was applied to expose and fix femoral head fractures by Herbert screws compressively. The operation time and intraoperative blood loss were recorded, and the effectiveness was evaluated according to the Thompson-Epstein scale at last follow-up.ResultsThe operation time was 80-130 minutes (mean, 97.5 minutes), and the intraoperative blood loss was 100-200 mL (mean, 130.2 mL). All fractures achieved anatomical reduction and successful fixation. All 12 patients were followed up 12-32 months (mean, 24.3 months). All patients achieved bone union in 15-20 weeks (mean, 16.3 weeks) and no wound infection, lateral femoral cutaneous nerve injury, osteonecrosis of the femoral head, or heterotopic ossification occurred. Traumatic arthritis occured in 3 patients. According to the Thompson-Epstein scale at last follow-up, the results were excellent in 5 cases, good in 5 cases, fair in 2 cases, and the excellent and good rate was 83.3%.ConclusionThe modified Hueter direct anterior approach has the advantages of clear anatomic structure, less trauma, and shorter operation time, and it can effectively expose and fix the Pipkin typeⅠ and Ⅱ femoral head fractures.

    Release date:2018-03-07 04:35 Export PDF Favorites Scan
  • Research progress of bone graft resorption after Latarjet procedure for treatment of recurrent anterior shoulder dislocation

    Objective To review the research progress of bone graft resorption after Latarjet procedure for the treatment of recurrent anterior shoulder dislocation, and provide a guide for further research on bone graft resorption. Methods The relevant literature in recent years was extensively reviewed. The pathogenesis, classification, risk factors, clinical function impact, and management of bone graft resorption after Latarjet procedure for the treatment of recurrent anterior shoulder dislocation were summarized. Results Bone graft resorption is the common complication after Latarjet procedure for the treatment of recurrent anterior shoulder dislocation. Stress shielding and poor blood supply may contribute to the occurrence of bone graft resorption. The absence of significant preoperative glenoid bone loss, open procedure, earlier graft healing may to be the risk factors for bone graft resorption. Various assessment methods and classification systems are used to evaluate the region and severity of bone graft resorption. Partial resorption may be considered as a natural glenoid remodeling process after the surgery, but severe and complete resorption is proved to be one of the reasons for failed procedures and there is no effective measure to prevent it, except for accepting revision surgery. Conclusion The pathogenesis, risk factors, clinical function impact of bone graft resorption after Latarjet procedure for the treatment of recurrent anterior shoulder dislocation has not been fully elucidated and there is a lack of effective management strategies, so further clinical and basic researches are needed.

    Release date:2023-05-11 04:44 Export PDF Favorites Scan
  • TREATMENT OF DEVELOPMENTAL DISLOCATION OF THE HIP WITH IMPROVED PEMBERTON METHOD

    Objective To find a more perfect method of treating developmental dislocation of the hip(DDH). Methods From March 1994 toDecember 2002, on the basis of the ordinary operative method, Pemberton method was improved for 48 cases of DDH 49 articulatio coxae which had superficial and small acetabula but bigheads of femur. Osteotomy points were moved higher to enlarge area of bone flapturned over. A piece of full thickness ilium including periosteum was removed as a free bony graft. Capsula articularis growing thicker was made into 2 layers, of which the inner layer was used to tighten articularis and the outer layerwas used to stabilize bone flap. Results All patients were followed up for 18 months to 5 years, the function of articulatio coxae and degree of bony union, inclusion area to head of femur and ischemic necrosis of femoral head were observed through X-ray. According to Zhou Yongde’s criteria for the curative effect of congenital dislocation of the hip, there were 18 cases of 26-30 scores(3 hips), 27 cases of 21-25 scores, 2 cases of 1620 scores(3 hips), and 1 case under 15 scores, and the total superior ratewas 93.8%. Conclusion Improved Pemberton method can enlarge inclusion area tohead of femur, avoid decreasing acetabular volume, and stabilize articulatio well, which made operative indication bigger than original Pemberton method.

    Release date:2016-09-01 09:33 Export PDF Favorites Scan
  • OPERATION VIA ANTERIOR APPROACH IN TREATING PELVIC CRESCENT FRACTURE

    Objective To evaluate the effectiveness of operation via anterior approach in treating pelvic crescent fra cture. Methods Between June 2007 and December 2009, 18 patients with pelvic crescent fracture were treated, including 11 males and 7 females with an average age of 32 years (range, 19-52 years). The locations were the right in 8 cases and the leftin 10 cases. Fractures were caused by traffic accident in 10 cases, by fall ing from height in 5 cases, and by crushing with heavy weights in 3 cases. All patients suffered lateral compression injuries of the pelvis. The mean time from injury to operation was 7.8 days (range, 3-22 days). The preoperative mean displacement of the posterior pelvic ring was 13.7 mm (range, 5-24 mm) according to the method described by Matta et al. The operation time, intraoperative blood loss, displacement correction of the posterior pelvic ring, fracture heal ing time, and Hannover pelvic score were recorded. Results The average operation time was 175 minutes (range, 110-230 minutes); the average intraoperative blood loss was 561.7 mL (range, 300-1 100 mL); the postoperative mean displacement of the posterior pelvic ring was 1.2 mm (range, 0-3 mm); and the mean displacement correction of the posterior pelvic ring was 12.6 mm (range, 4-23 mm). No intraoperative lumbosacral nervous injury occurred. Superficial wound infection occurred in 2 cases and was cured after 1 week of wound drainage and appl ication of antibiotic. The others achieved heal ing of incision by first intention. Fifteen patients were followed up 16.1 months on average (range, 13-22 months). The X-ray films showed fracture heal ing in all patients. The fracture heal ing time was 3.6 months on average (range, 3-4 months). No patient had loss of reduction or failure of internal fixation. The cl inical outcome was excellent in 10 cases (66.7%) and good in 5 cases (33.3%) according to Hannover pelvic score; social reintegration was complete in 13 cases (86.7%) and incomplete in 2 cases (13.3%). Conclusion Operation via anterior approach is a good choice in the treatment of pelvic crescent fracture.

    Release date:2016-08-31 05:44 Export PDF Favorites Scan
  • RECONSTRUCTION OF HIP JOINT FUNCTION:OLD FRACTURE DISLOCATION OF HIP JOINT COMPLICATED WITH DEFORMED HEALING OF UPPER 1/3 OF FRACTURED FEMUR——A CASE REPORT

    OBJECTIVE: To explore a method of reconstruction of hip joint function after deformed healing of the upper 1/3 of fractured femur as a complication of old fracture dislocation of hip joint. METHODS: A patient with loss of function in hip joint and fusion of knee joint was treated with lock for femur intra-medullary fixation in April 1997. RESULTS: Before operation, the diseased hip joint lost its most functions and the entire lower extremity was disabled because the knee joint had been fused. One year after operation, the follow-up examination revealed that the patient could walk by crutches without discomfort, his daily life and work recovered to normal. CONCLUSION: It is effective to treat a patient suffering old fracture-dislocation of hip joint complicated with deformed healing of the upper 1/3 of fractured femur by means of individualized artificial joint replacement and a prosthesis body with lock for femur intra-medullary fixation, and it is helpful for the development of a new clinical idea to reconstruct functions in the management of some particular cases.

    Release date:2016-09-01 11:05 Export PDF Favorites Scan
  • Development and biomechanical study of anatomical locking plate of sternoclavicular joint

    Objective To develop an anatomical locking plate in accordance with the anatomical characteristics of the sternoclavicular joint, which is reliable fixation and easy to operate, so as to provide an ideal internal fixation device for the treatment of sternoclavicular joint dislocation or peripheral fractures. Methods Gross measurement and CT measurement were performed on the 8 adult antiseptic and moist cadaver specimens (16 sides) to measure the parameters of surrounding bone structure of the sternoclavicular joint. The parameters included the thickness of presternum, sternal notch width, anteroposterior diameter of proximal 1/3 of clavicle, upper and lower diameters of proximal 1/3 of clavicle, angle between proximal end of clavicle and presternum in coronal plane, and angle of thoracoclavicular joint at anatomic position forward. According to the anatomical parameters and biomechanical properties of the specimens, the anatomical locking plate was designed and developed. The sternoclavicular ligament and joint capsule of all the specimens were completely cut off to make the sternoclavicular joint dislocation model. The left and right sternoclavicular joint of each specimen were randomly divided into experimental group (anatomic locking plate fixation) and control group (oblique T shape locking plate fixation). The sternoclavicular joint activity and common force mechanism was simulated on the universal mechanical testing machine, and the clavicular distal load test, sternoclavicular joint torsion test, and anti-pulling of steel plate manubrium part test were performed. Results The differences between the anatomical parameters of gross measurement and CT measurement were not significant (P>0.05). In the clavicular distal load test, when the anatomical position perpendicular to the distal clavicle back loading to 20 N, the displacement of loading point in the experimental group was (8.455±0.981) mm, which was significantly less than that in control group [(10.163±1.379) mm] (t=–3.012,P=0.020); the distal clavicle displacement of loading point of experimental group and control group were (5.427±1.154) mm and (6.393±1.040) mm, respectively, showing no significant difference (t=–1.459, P=0.188). In the sternoclavicular joint torsion test, the torque of experimental group was significantly greater than that of control group when the clockwise torsion angle was at 2, 4, 6, 8, and 10 degrees and the counterclockwise torsion angle was at 4, 6, 8, and 10 degrees (P<0.05). The torsional stiffness in the experimental group under clockwise and counterclockwise condition was 0.122 and 0.108 N·m/° respectively, which were significantly higher than those in the control group (0.083 and 0.078 N·m/° respectively) (F=67.824, P=0.000; F=20.992, P=0.002). In the anti-pulling of steel plate manubrium part test, the maximum pullout force of experimental group [(225.24±16.02) N] was significantly higher than that in control group [(174.40±21.90) N] (t=5.785, P=0.001). Conclusion The new type of anatomical locking plate can realize the sternoclavicular joint three-dimensional fixation, and has the advantages of reliable fixation, simple operation, less trauma, superior biomechanical properties, and earlier functional exercise. It may be an ideal internal fixation device in clinical treatment of sternoclavicular joint dislocation or peripheral fractures.

    Release date:2018-01-09 11:23 Export PDF Favorites Scan
  • Mid-term effectiveness of modified arthroscopic suture button fixation Latarjet procedure for treatment of recurrent anterior shoulder dislocations

    Objective To summarize mid-term effectiveness of modified arthroscopic suture button fixation Latarjet procedure for treatment of recurrent anterior shoulder dislocations. Methods Between January 2018 and October 2020, 30 patients with recurrent anterior shoulder dislocations were treated with modified arthroscopic suture button fixation Latarjet procedure. There were 19 males and 11 females with an average age of 27.3 years (range, 18-41 years). The shoulder dislocation occurred 3-7 times, with an average of 4.9 times. The time from the last dislocation to operation was 3-10 days, with an average of 4.1 days. Glenoid defects exceeded 20% in all cases. There were 27 cases of Hill-Sachs lesions. The joint pain and function were estimated by visual analogue scale (VAS) score, University of California, Los Angeles (UCLA) score, Rowe score, American Association for Shoulder and Elbow Surgery (ASES) score, Walch-Duplay score, and the range of external rotation at 0° and external rotation at 90° abduction of shoulder before operation and at 1 month, 6 months, and last follow-up. The X-ray film, CT scan and three-dimensional reconstruction were reviewed to observe the position, healing, and absorption of the coracoid graft, correction of glenoid defect, and joint degeneration.Results The operation time ranged from 51 to 79 minutes, with an average of 68.4 minutes. All incisions healed without complications such as nerve or blood vessel injury. All patients were followed up 36-60 months with an average of 44.6 months. The VAS score, UCLA score, Rowe score, ASES score, Walch-Duplay score, and the range of external rotation at 0° and external rotation at 90° abduction after operation significantly improved when compared with preoperative values (P<0.05). All indicators further improved with time, and the differences between different time points after operation were significant (P<0.05). Imaging review showed that the coracoid graft was located in the anteroinferior glenoid at 1 day after operation, and no occurrence of shoulder osteoarthritis was found during follow-up. The anatomical structure of the glenoid was normal, and no delayed healing or non-union of the coracoid graft occurred. At 20 months after operation, arthroscopic re-exploration was performed in 1 case due to fracutre caused by falling injury revealed the good shaping of the coracoid graft, smooth glenoid, and no bone resorption or osteoarthritis. ConclusionFor recurrent anterior shoulder dislocations, the modified arthroscopic suture button fixation Latarjet procedure can obtain good recovery of shoulder function and low incidence of complications and has a good mid-term effectiveness.

    Release date:2024-06-14 09:52 Export PDF Favorites Scan
  • Short-term effectiveness of modified arthroscopic Latarjet procedure with double EndoButtons for recurrent anterior shoulder dislocation

    Objective To evaluate the short-term effectiveness of modified arthroscopic Latarjet procedure with double EndoButtons for recurrent anterior shoulder dislocation. Methods Between January 2019 and November 2020, 36 patients with recurrent anterior shoulder dislocation were treated by modified arthroscopic Latarjet procedure with double EndoButtons. There were 26 males and 10 females, with an average age of 27.8 years (range, 18-36 years). The number of shoulder dislocations ranged from 3 to 12 times, with an average of 6.5 times. The disease duration ranged from 5 to 36 months, with an average of 16.2 months. Preoperative shoulder fear test was positive, and the Beighton score of joint relaxation was 0-4, with an average of 1.3. Imaging examination showed that the defect width of the ipsilateral glenoid bone was 16%-28%, with an average of 21.5%. Postoperative complications, recurrent dislocation, subluxation, and instability of shoulder joint were recorded. Shoulder range of motion was examined, including forward flexion, external rotation at side, external rotation at 90° abduction, and internal rotation. Shoulder joint function was evaluated by Walch-Duplay score, American Association for Shoulder and Elbow Surgery Score (ASES), and ROWE score. X-ray film and CT images were taken to observe the shaping of coracoid process graft. Results All incisions healed by first intention, and no vascular or nerve injury occurred. All patients were followed up 12-28 months, with an average of 19.9 months. During follow-up, no shoulder dislocation recurred, and shoulder fear test was negative. At last follow-up, there was no significant difference in shoulder forward flexion, external rotation at side, external rotation at 90° abduction, and internal rotation when compared with preoperative values (P>0.05). The Walch-Duplay score, ASES score, and ROWE score of shoulder function significantly improved (P<0.05). Postoperative imaging examination showed that coracoid process graft was at the same level with the glenoid in 33 cases (91.7%), medial in 1 case (2.8%), and lateral in 2 cases (5.6%); the center of coracoid process graft was mainly located between 3 to 5 o’clock in 33 cases (91.7%), higher than 3 o’clock in 1 case (2.8%), and lower than 5 o’clock in 2 cases (5.6%). There was no obvious glenohumeral joint degeneration during follow-up, and the coracoid process graft gradually formed concentric circles with the humeral head. Conclusion The modified arthroscopic Latarjet procedure with double EndoButtons can effectively treat recurrent anterior shoulder dislocation, and the short-term effectiveness is satisfactory, and the position of coracoid process graft is accurate.

    Release date:2022-09-30 09:59 Export PDF Favorites Scan
15 pages Previous 1 2 3 ... 15 Next

Format

Content