find Keyword "echocardiography" 69 results
  • Analysis of Failure of Perventricular Device Closure of Ventricular Septal Defect

    摘要:目的:分析微创外科室间隔缺损(ventricular septal defect,VSD)封堵失败原因,以期提高术前超声心动图筛查水平。方法:回顾性分析25例微创外科VSD封堵失败改行修补术病例,对比超声表现及手术所见,归纳总结产生并发症的原因。结果:残余分流与VSD假性膜部瘤右室面具有多个出口和低估VSD大小密切相关;VSD合并主动脉瓣右冠瓣脱垂是主动脉瓣反流的主要原因;封堵器移位与低估VSD大小且使用偏心封堵器有关;原有三尖瓣反流加重和发生Ⅲ度房室传导阻滞VSD均位于隔瓣下方;封堵失败组较封堵成功组缺损偏大,差异具有统计学意义(Plt;0.05)。结论:超声心动图对VSD及其毗邻结构的细致评估,有助于严格适应证,提高手术成功率。 Abstract: Objective:To analyze the failure of perventricular closure of ventricular septal defect (VSD), in order to improve the preoperative echocardiography examination. Methods: Twentyfive cases underwent surgical repair after failure of perventricular closure of VSD were included in this study. With combination of echocardiographic and surgical findings, retrospective analysis of the failure of perventricular closure of VSD were attempted to summarize the cause of complications.Results: Residual ventricular communication was due to underestimation of size of VSD and pseudomembranous aneurysm resulting in multiple outlets of VSD on the right ventricle side; preoperative prolapse of rightcoronary cusp was the main reason for mild or greater than mild aortic valve regurgitation after eccentric device closure of VSD; Underestimation of the size of VSD and using eccentric occluder device were responsible for the displacement of VSD occluder device. Postoperative aggravated tricuspid regurgitation and Ⅲ°atrialventricular block (AVB) were attributed to VSDs located under the septal leaflet of tricuspid valve. The size of VSD in group of failed perventricular device closure of VSD was larger than that in group of successful device closure of VSD,and the difference was significant(Plt;0.05). Conclusion: Echocardiography vividly reveals VSD and adjacent structures, which should be used in accessing the anomaly and defect and formulating surgical plans to reduce surgical morbidity and mortality.

    Release date:2016-09-08 10:12 Export PDF Favorites Scan
  • The Application of Transesophageal Echoeardiography for Atrial Septal Defect Blockade Operation

    【摘要】 目的 评价经食管超声心动图(TEE) 监测房间隔缺损封堵术的临床价值。 方法 手术前应用经胸超声心动图(TTE)及TEE筛选符合条件的100例单纯房间隔缺损(ASD)患者行封堵术;手术中TEE监测整个封堵过程和引导封堵伞的放置;手术后评价封堵效果、残余分流或并发症等。 结果 100例患者均应用TTE和TEE确诊,导引和监测成功闭合房间隔缺损。技术成功96例,成功率96%;4例失败,失败率4%。手术后复查无1例残余分流,3例胸腔积液。经胸超声心动图与TEE诊断结果完全一致率40%,TEE诊断对手术前TTE诊断做出补充或修正诊断的有60例(60%)。结论 TEE对选择适合行封堵术者、选择封堵器大小、指导封堵器的释放、以及疗效评价均具有重要的作用。【Abstract】 Objective To evaluation the clinical role of transesophageal echocardiography (TEE) for atrial septal defect (ASD) blockade operation. Method The 100 patients with ASD were selected on transthoracic echocardiography (TTE) and TEE. During operation, TEE was applied to monitor the procedure of occlusion, to guide the occluder cites, to evaluate the effects and to make sure if there were peripheral residual shunts around the occlusion and other complications. Results All of the patients were exactly diagnosed by TTE and TEE,guiding and evaluating the successful closed ASD. The successful rate of occlusion was 96%,the failure rate was 4%. The review after surgery showed that, there were no residual review, pleural effusion in three patients. The concordance rate of TTE and TEE diagnosis result is 40%. TEE diagnosis amend the preoperative TTE diagnosis in 60 patients (60%). Conclusions TEE plays an important role in select inpatients,determining the size of the occluder,correctly before occlusion operation, guiding the placement of the occluder in operation and evaluating the effect after operation.

    Release date:2016-09-08 09:45 Export PDF Favorites Scan
  • Study on Downstream Flow Field Uniformity of Aortic Stenosis by Using Pulse Wave Doppler Echocardiography

    ObjectiveBy comparing the difference between different stenosed degree of aortic valve in flow field uniformity and turbulent shear stress (TSS), to explore the relation between flow field uniformity and different stenosed degree of aortic valve, and probe the clinical value for deciding the operation timing, and analyze the possible role of TSS in the progress of the disease.MethodsThe flow field uniformity values and TSS in parasternal long axis plane and apical five cavity plane on each point were measured and calculated by pulse wave Doppler echocardiography technique for 33 patients with different stenosed degree of aortic valve.ResultsThere were significant difference between the different stenosed degree of aortic valve in maximal velocity difference(ΔV max )and TSS( P lt;0.05, 0.01). The more severe the aortic stenosis was, the worse the flow field uniformity was, the lower the TSS was.ConclusionsThere are significant difference between the patients of different stenosed degree of aortic valve in flow field uniformity. Flow field uniformity has important value in classifying the degree of aortic stenosis and deciding the timing of operation. The more severe the aortic stenosis is ,the lower TSS is. It can be thought that low TSS distribution has important role in pathological process of constriction in cardiovascular system diseases.

    Release date:2016-08-30 06:24 Export PDF Favorites Scan
  • Efficacy analysis of esophageal ultrasound-guided percutaneous femoral artery closure for ventricular septal defect

    ObjectiveTo investigate the effectiveness and safety of esophageal ultrasound-guided percutaneous femoral artery closure of ventricular septal defect (VSD).MethodsThe clinical data of 24 patients with congenital VSD in our hospital from March 2017 to December 2019 were retrospectively analyzed, including 6 males and 18 females, with a median age of 12 (3-42) years, weight of 32 (12-91) kg, and VSD diameter of 4 (3-7) mm. There were 3 patients with VSD combined with atrial septal defect.ResultsTwenty-four patients successfully underwent interventional closure of percutaneous femoral artery under esophageal ultrasound guidance, and the position and shape of the occluders were good. The operation time was 45 (39-54) min, and the waist size of the occluders was 7 (5-12) mm. Among the patients, 14 patients used symmetric ventricular occlusion devices, 8 patients used asymmetric ventricular occlusion devices, and 2 patients used ventricular occlusion muscle occluders. Small amount of residual shunt occurred in 2 patients after the operation and it disappeared 3 months after the operation. One patient with right bundle branch block, which disappeared after 1 week of observation. There were no complications such as occluder closure, pericardial effusion or valve regurgitation during the perioperative period. During the follow-up period [3-18 (9.25±5.04) months], no serious complication occurred.ConclusionTransesophageal ultrasound-guided transfemoral artery occlusion for VSD is simple and safe, and it avoids the damage of radiation and contrast medium. It has advantages over traditional percutaneous interventional occlusion therapy.

    Release date:2021-12-27 11:31 Export PDF Favorites Scan
  • Anesthesia management experience in transcatheter ultrasound-guided percutaneous interventional treatment of congenital heart disease at a mobile operating platform

    ObjectiveTo explore the anesthesia management experience in the interventional treatment of pediatric congenital heart diseases (CHD) percutaneously guided by transthoracic echocardiography (TTE) on a mobile operating platform. Methods From March to July 2023, a total of 13 patients from remote areas underwent interventional treatment for CHD on the mobile operating platform of Fuwai Yunnan Cardiovascular Hospital. Patients who received non-tracheal intubation general anesthesia were retrospectively included. ResultsEight children who had difficulty cooperating with the surgery (due to young age, emotional tension, crying) received monitored anesthesia care with local anesthesia supplemented by sedative and analgesic drugs while maintaining spontaneous breathing under the monitoring and management of an anesthesiologist (i.e., non-tracheal intubation general anesthesia). Among them, there were 5 males and 3 females, with an age of (6.95±3.29) years and a body weight of (19.50±6.04) kg. Through transthoracic echocardiography, they were diagnosed with atrial septal defect (6 patients), residual shunt after patent ductus arteriosus ligation (1 patient), and severe pulmonary valve stenosis (1 patient). The surgery proceeded smoothly, with satisfactory anesthesia and surgical effects, complete analgesia, and satisfactory postoperative recovery. There was 1 patient of body movement and 1 patient of respiratory depression during the operation, and both patients completed the surgery successfully after treatment. All children had no serious surgery- and anesthesia-related complications. The anesthesia time was 40.5 (34.5, 47.5) min, the surgery time was 39.0 (33.0, 45.5) min, and the recovery time was 43.0 (28.0, 52.5) min Conclusion Interventional surgery for CHD guided by TTE at a mobile platform is a minimally invasive approach without radiation damage. Non-tracheal intubation general anesthesia with spontaneous breathing can be safely and effectively implemented in children who cannot cooperate.

    Release date:2025-09-22 05:53 Export PDF Favorites Scan
  • Comparison of two methods for hemodynamic assessment in children with tetralogy of Fallot after radical surgery

    Objective To explore the hemodynamic assessment after radical surgery in children with tetralogy of Fallot (TOF) by both echocardiography and Mostcare monitor. Methods Clinical data of 63 children with TOF who underwent radical surgery in our hospital from February 2016 to June 2018 were retrospectively analyzed, including 34 males and 29 females, aged 6-24 (9.82±5.77) months. There were 19 patients undergoing transannular patch reconstruction of the right ventricular outflow tract (a transannular patch group) while 44 patients retained the pulmonary valve annulus (a non-transannular patch group) . The echocardiography and Mostcare monitor parameters were recorded and brain natriuretic peptide was tested at the time points of 0, 8, 12, 24 and 48 hours after operation (T 0, T 1, T 2, T 4) to analyze their correlations and the change trend at different time points after radical surgery. Results The left ventricular ejection fraction at T 1 (43.49%±3.82%) was lower than that at T 0 (48.29%±4.55%), T 2 (45.83%±3.69%), T 3 (53.76%±4.43%) and T 4 (60.54%±3.23%, P<0.05). The cardiac index at T 1 (1.85±0.35 L·min−1·m−2) was lower than that at T 0 (2.11±0.38 L·min−1·m−2), T 2 (2.07±0.36 L·min−1·m−2), T 3 (2.42±0.37 L·min−1·m−2) and T 4 (2.82±0.42 L·min−1·m−2, P<0.05). The cardiac circulation efficiency at T1 (0.19±0.05) was lower than that at T 0 (0.22±0.06), T 2 (0.22±0.05), T 3 (0.28±0.06) and T 4 (0.34±0.06, P<0.05). The right ventricular two-chambers view fraction area change at T 1 (23.17%±3.11%) was lower than that at T 0 (25.81%±3.74%), T 2 (25.38%±3.43%), T 3 (30.60%±4.50%) and T 4 (36.94%±5.85%, P<0.05). The pulse pressure variability was the highest at T 0 (18.76%±3.58%), followed by T 1 (14.81%±3.32%), T 2 (12.44%±2.94%), T 3 (10.39%±2.96%) and T 4 (9.18%±1.92%, P<0.05). The blood brain natriuretic peptide was higher at T 1 (846.67±362.95 pg/ml) than that at T 0 (42.60±18.06 pg/ml), T 2 (730.95±351.09 pg/ml), T 3 (510.98±290.39 pg/ml) and T 4 (364.41±243.56 pg/ml, P<0.05). There was no significant difference in left ventricular ejection fraction, cardiac circulation efficiency and heart index between the two groups (P>0.05). The right ventricular two-chambers view fraction area change of the transannular patch group was significantly lower than that of the non-transannular patch group at each time point (P<0.05). The blood brain natriuretic peptide and pulse pressure variability of the transannular patch group were significantly higher than those of the non-transannular patch group (P<0.05). Left ventricular ejection fraction was positively correlated with cardiac index (r=0.637, P=0.001) and cardiac circulation efficiency (r=0.462, P=0.001) while was significantly negatively correlated with blood brain natriuretic peptide (r=–0.419, P=0.001). Conclusion Both methods can accurately reflect the state of cardiac function. Mostcare monitor has a good consistency with echocardiography. Using transannular patch to recontribute right ventricular outflow tract in operation has more influence on right ventricular systolic function. The Mostcare monitor can guide the hemodynamic management after surgery in real time, continuously and accurately.

    Release date:2019-03-29 01:35 Export PDF Favorites Scan
  • Predictive value of systolic pulmonary artery pressure on autonomic nerve excitation in 186 patients with valvular disease: A prospective study

    ObjectiveTo explore the predictive value of systolic pulmonary artery pressure (SPAP) on autonomic nerve excitation in patients with valvular disease, so as to provide reference for the formulation of clinical intervention plans. Methods The clinical data of patients with valvular disease who received surgical treatment in the General Hospital of Northern Theater Command from August 28, 2020 to February 3, 2021 were prospectively collected. According to the standard deviation of normal-to-normal R-R intervals (SDNN) of the heart rate variability (HRV) of the long-range dynamic electrocardiogram (ECG) 7 days before the operation, the patients were divided into three groups: a sympathetic dominant (SE) group (SDNN≤50 ms), a balance group (50 ms<SDNN<100 ms) and a parasympathetic dominant (PSE) group (SDNN≥100 ms). The correlation between the changes of echocardiographic indexes and autonomic nerve excitation among the groups and the predictive values were analyzed. Results A total of 186 patients were enrolled, including 108 males and 78 females aged 55.92±11.99 years. There were 26 patients in the SE group, 104 patients in the balance group, and 56 patients in the PSE group. The left anteroposterior diameter (LAD), left ventricular end diastolic inner diameter, ratio of peak E to peak A of mitral valve (Em/Am), left ventricular end diastolic volume, left ventricular end systolic volume and SPAP in the SE group were higher than those in the balance group (P<0.05), while peak A of tricuspid valve (At) and left ventricular ejection fraction (LVEF) were lower than those in the balance group (P<0.05). The LAD and Em/Am in the balance group were significantly higher than those in the PSE group (P<0.05). Multivariate analysis showed that patients in the SE group had lower At (right atrial systolic function declines), lower LVEF and higher SPAP than those in the balance group (P=0.04, 0.04 and 0.00). When HRV increased and parasympathetic nerve was excited in patients with valvular disease, Em/Am decreased (left atrial function and/or left ventricular diastolic function declined) with a normal LAD. Pearson analysis showed that there was a linear negative correlation between SPAP and SDNN, with a coefficient of −0.348, indicating that the higher SPAP, the lower HRV and the more excited sympathetic nerve. Receiver operating characteristic curve showed that when SPAP≥45.50 mm Hg (1 mm Hg=0.133 kPa), the sensitivity and specificity of sympathetic excitation in patients with valvular disease were 84.60% and 63.70%, respectively. ConclusionParasympathetic excitation is an early manifestation of the disease, often accompanied by decreased left atrial function and/or left ventricular diastolic function. Sympathetic nerve excitation can be accompanied by the increase of SPAP and the decrease of left ventricular and right atrial systolic function. SPAP has a unique predictive value for the prediction of autonomic nerve excitation in patients with valvular disease.

    Release date:2024-02-20 03:09 Export PDF Favorites Scan
  • Treatment of patent ductus arteriosus via ultrasound-guided percutaneous antegrade or retrograde access: A retrospective cohort study

    ObjectiveTo compare the surgical results of ultrasound-guided percutaneous antegrade or retrograde therapy in the treatment of patent ductus arteriosus.MethodsThe clinical data of 166 patients (44 males and 122 females) who underwent transthoracic echocardiography guided closure of patent ductus arteriosus in Xinjiang Cardiovascular and Cerebrovascular Disease Hospital from February 2016 to August 2020 were retrospectively analyzed, and the patients were divided into two groups: an antegrade group (n=60) and a retrograde group (n=106). The operation time, success rate, bed rest time, postoperative complications and surgical safety were compared between the two groups.ResultsThe immediate success rate of the two groups was 100.0%. Compared with the retrograde group, the antegrade group had shorter time of bed rest and hospital stay, but longer operation time. In the retrograde group, there were 2 patients of complications, including occlusive device falling off to pulmonary artery 12 hours after the operation in 1 patient, and false arterial tumor in 1 patient. Both groups were followed up for 3-18 months, and there was no death in the whole group.ConclusionIt is safe and effective to block patent ductus arteriosus under the guidance of transthoracic echocardiography. Although the operation process of anterior occlusion of patent ductus arteriosus is slightly complex and the operation time is long, the indication is wide, and the bed rest time is short. Therefore it can be used as the first choice for patent ductus arteriosus occlusion.

    Release date:2022-08-25 08:52 Export PDF Favorites Scan
  • Real-time Three Dimensional Echocardiography Guided Closure of Atrial Septal Defect through a RightMinithoracotomy in Comparison with Traditional Surgical Repair under Cardiopulmonary Bypass

    Objective To compare surgical results between real-time three dimensional echocardiography(RT-3DE) guided closure of atrial septal defect (ASD) through a right minithoracotomy and traditional surgical repair under cardiopulmonary bypass (CPB). Methods Sixty-four patients with secundum ASD received surgical repair in the First People’s Hospital of Honghe Autonomous Prefecture from April 2009 to April 2012. According to different surgical approach, all the patients were divided into group A and B. In group A, 35 patients underwent traditional ASD repair under CPB including 20males and 15 females with their age of 12-56 (16.4±4.0) years. In group B, 29 patients received real-time RT-3DE guidedASD closure through a right minithoracotomy without CPB, including 20 males and 15 females with their age of 15-50 (18.5±0.2) years. Operation time,postoperative mechanical ventilation time,hospital stay,chest drainage,mortality,morbidity and follow-up outcomes were compared between the 2 groups. Results Operation time (110.47±35.90 minutesvs. 159.32±20.60 minutes),postoperative mechanical ventilation time (10.40±22.30 hours vs. 16.40±12.20 hours),chestdrainage (106.71±85.20 ml vs. 146.70±75.63 ml)and postoperative hospital stay (4.0±1.0 days vs. 7.0±1.0 days)ofgroup B were significantly shorter or less than those of group A. In group A, 1 patient died postoperatively and 7 patientshad postoperative complications. In group B, there was no in-hospital mortality and 3 patients had postoperative complications.Postoperative morbidity of group A was significantly higher than that of group B (20.0% vs. 10.3%,P<0.05) . ConclusionFor ASD patients with definite surgical indications,RT-3DE guided ASD closure through a right minithoracotomy has more advantages over traditional surgical repair under CBP.

    Release date:2016-08-30 05:47 Export PDF Favorites Scan
  • Research progress on the management of patients after cardiac surgery with miniaturized transesophageal echocardiography

    In recent years, transesophageal echocardiography has a trend toward miniaturization, so it has great clinical significance and broad clinical application prospect in the management of Cardiac Surgery ICU patient. This paper presents the characteristics of miniaturized transesophageal echocardiography and its clinical application. And we also focused on the contrast between miniaturized transesophageal echocardiography and standard transesophageal echocardiography and transthoracic echocardiography.

    Release date:2017-09-26 03:48 Export PDF Favorites Scan