Objective To review the progress and application of peripheral nervous microelectrode. Methods The recent articles on peripheral nervous microelectrode were extensively reviewed. The classification, the progress of the peripheral nervous microelectrode and its utilizable prospect in the control of electronic prosthesis were summarized. Results The microelectrodes had favorable functions of selective stimulation and recording. It provided an information transmitting interface between the electric prosthesis and peripheral nerves. Conclusion Peripheral nervous signal is a feasible signal source to control electronic prosthesis.
Micro- and integrated biosensor provides a powerful means for cell electrophysiology research. The technology of electroplating platinum black on the electrode can uprate signal-to-noise ratio and sensitivity of the sensor. For quantifying analysis of the processing method of electroplating process, this paper proposes a grid search algorithm based on the Monte-Carlo model. The paper also puts forward the operational optimization strategy, which can rapidly implement the process of large-scale nanoparticles with different particle size of dispersion (20-200 nm) attaching to the electrode and shortening a simulation time from average 20 hours to 0.5 hour when the test number is 10 and electrode radius is 100 μm. When the nanoparticle was in a single layer or multiple layers, the treatment uniformity and attachment rate was analyzed by using the grid search algorithm with different sizes and shapes of electrode. Simulation results showed that under ideal conditions, when the electrode radius is less than 100 μm, with the electrode size increasing, it has an obvious effect for the effective attachment and the homogeneity of nanoparticle, which is advantageous to the quantitative evaluation of electrode array's repeatability. Under the condition of the same electrode area, the best attachment is on the circular electrode compared to the attachments on the square and rectangular ones.
The injury of the knee joint is usually accompanied with the generation of hydrops. The volume of hydrops can be used as a reference to evaluate the extent of knee joint injuries. Based on the principle of bioimpedance detection, in this paper, a new method is proposed to detect knee joint hydrops. Firstly, a three-dimensional model of the knee joint was established according to the physiological and anatomical structure of the knee joint. Secondly, a knee impedance detection system was constructed based on the four-electrode theory, and the relationship between the knee impedance change and the volume of hydrops was calculated by linear regression. Finally, the model of rat knee joint hydrops was established, and the knee joint impedance was measured under different hydrops content to deduce the relationship between the fluid content and the knee joint impedance. The fluid volume in the joint was calculated by measuring the knee joint impedance, and the error rate was less than 10%. The experimental results show that the method proposed in this paper can establish the relationship between the impedance of the knee and the volume of fluid and realize the detection of the fluid volume.
In order to accurately implant the brain electrodes of carp robot for positioning and navigation, the three-dimensional model of brain structure and brain electrodes is to be proposed in the study. In this study, the tungsten electrodes were implanted into the cerebellum of a carp with the aid of brain stereotaxic instrument. The brain motor areas were found and their three-dimensional coordinate values were obtained by the aquatic electricity stimulation experiments and the underwater control experiments. The carp brain and the brain electrodes were imaged by 3.0 T magnetic resonance imaging instrument, and the three-dimensional reconstruction of carp brain and brain electrodes was carried out by the 3D-DOCTOR software and the Mimics software. The results showed that the brain motor areas and their coordinate values were accurate. The relative spatial position relationships between brain electrodes and brain tissue, brain tissue and skull surface could be observed by the three-dimensional reconstruction map of brain tissue and brain electrodes which reconstructed the three-dimensional structure of brain. The anatomical position of the three-dimensional reconstructed brain tissue in magnetic resonance image and the relationship between brain tissue and skull surface could be observed through the three-dimensional reconstruction comprehensive display map of brain tissue. The three-dimensional reconstruction model in this study can provide a navigation tool for brain electrodes implantation.
ObjectiveTo evaluate the application of stereotactic electrode implantation on precise epileptogenic zone localization. MethodRetrospectively studied 140 patients with drug-resist epilepsy from March 2012 to June 2015, who undergone a procedure of intracranial stereotactic electrode for localized epileptogenic zone. ResultsIn 140 patients who underwent the ROSA navigated implantation of intracranial electrode, 109 are unilateral implantation, 31 are bilateral; 3 patients experienced an intracranial hematoma caused by the implantation. Preserved time of electrodes, on average, 8.4days (range 2~35 days); Obseved clinical seizures, on average, 10.8 times per pt (range 0~98 times); There were no cerebrospinal fluid leak, intracranial hematoma, electrodes fracture or patient death, except 2 pt's scalp infection (1.43%, scalp infection rate); 131 pts' seizure onset area was precisely localized; 71 pts underwent SEEG-guide resections and were followed up for more than 6 months. In the group of 71 resection pts, 56 pts were reached Engel I class, 2 were Engel Ⅱ, 3 was Engel Ⅲ and 10 were Engel IV class. ConclusionTo intractable epilepsy, when non-invasive assessments can't find the epileptogenic foci, intracranial electrode implantation combined with long-term VEEG is an effective method to localize the epileptogenic foci, especially the ROSA navigated stereotactic electrode implantation, which is a micro-invasive, short-time, less-complication, safe-guaranteed, and precise technique.
ObjectiveThe purpose of this study was to compare the value of SEEG and subdural cortical electrodes monitoring in preoperative evaluation of epileptogenic zone. MethodsFeatures of patients using SEEG (48 cases) and subdural cortical electrodes monitoring (52 cases) to evaluate the epileptogenic zone were collected from June 2011 to June 2015. And the evaluation results, surgical effects and complications were compared. ResultsThere was no significant difference between SEEG and subdural cortical electrodes monitoring in identifying the epileptogenic zone or taking epileptic surgery, but SEEG could monitor multifocal and bilateral epileptogenic zone. And there was no significant difference in postoperative seizure control and intelligence improvement (P > 0.05). The total complication rate of SEEG was lower than subdural cortical electrodes monitoring, especially in hemorrhage and infection (P < 0.05). ConclusionsThere was no difference among SEEG and subdural cortical electrodes monitoring in surgical results, but SEEG with less hemorrhagic and infectious risks. SEEG is a safe and effective intracranial monitoring method, which can be widely used.
A hand-held electrocardiogram (ECG) monitor with capacitive coupling is designed in this study that can rapidly detect ECG signals through clothing. This new device improves many deficiencies of the traditional ECG monitor, such as infection due to direct skin contacting, inconvenience, and time-consuming. In specificity, the hand-held ECG monitor consists of two parts, a sensor and an embedded terminal. ECG signals are initially detected by a sensing electrode placed on the chest through clothing, then treated by single ended differential amplification, filtering and master amplification, and later processed through A/D conversion and ECG signal transmission by CC2540 module. The waveform and heart rate are finally displayed on the screen based on digital filtering and data processing for the received ECG signal on the embedded terminal. Results confirm that the newly developed hand-held ECG monitor is capable of detecting real-time ECG signals through clothing with advantages of simple operation, portability and rapid detection.
In order to quantitatively evaluate the performance of dry electrode for fabric surface bioelectricity, a set of active measuring devices that can simulate electrocardiosignal has been developed on the basis of passive system by our group. Five Ag/AgCl fabric dry electrodes were selected to test and evaluate the devices. The results show that the deviation ratios of peak time interval of the five electrodes are all less than 1%. The maximum voltage amplitude decay rate is 7.2%, and the noise amplitudes are lower than 0.004 mV. The variable coefficient of peak time offset is less than 8%. The variable coefficient of voltage amplitude is less than 2%. The variable coefficient of noise amplitude is less than 10%. Research shows the devices has good repeatability and stability in measuring the simulated electrocardiosignal. The active measuring devices proposed in this paper can provide a new method for performance evaluation and standard formulation of surface bioelectricity dry electrode.
In order to solve the problems of insufficient stimulation channels and lack of stimulation effect feedback in the current electrical stimulation system, a functional array electrode electrical stimulation system with surface electromyography (sEMG) feedback was designed in this paper. Firstly, the effectiveness of the system was verified through in vitro and human experiments. Then it was confirmed that there were differences in the number of amperage needed to achieve the same stimulation stage among individuals, and the number of amperage required by men was generally less than that of women. Finally, it was verified that the current required for square wave stimulation was smaller than that for differential wave stimulation if the same stimulation stage was reached. This system combined the array electrode and sEMG feedback to improve the accuracy of electrical stimulation and performed the whole process recording of feedback sEMG signal in the process of electrical stimulation, and the electrical stimulation parameters could change with the change of the sEMG signal. The electrical stimulation system and sEMG feedback worked together to form a closed-loop electrical stimulation working system, so as to improve the efficiency of electrical stimulation rehabilitation treatment. In conclusion, the functional array electrode electrical stimulation system with sEMG feedback developed in this paper has the advantages of simple operation, small size and low power consumption, which lays a foundation for the introduction of electrical stimulation rehabilitation treatment equipment into the family, and also provides certain reference for the development of similar products in the future.
The effect of deep brain stimulation (DBS) surgery treatment for Parkinson's disease is determined by the accuracy of the electrodes placement and localization. The subthalamic nuclei (STN) as the implant target is small and has no clear boundary on the images. In addition, the intra-operative magnetic resonance images (MRI) have such a low resolution that the artifacts of the electrodes impact the observation. The three-dimensional (3D) visualization of STN and other nuclei nearby is able to provide the surgeons with direct and accurate localizing information. In this study, pre- and intra-operative MRIs of the Parkinson's disease patients were used to realize the 3D visualization. After making a co-registration between the high-resolution pre-operative MRIs and the low-resolution intra-operative MRIs, we normalized the MRIs into a standard atlas space. We used a special threshold mask to search the lead trajectories in each axial slice. After checking the location of the electrode contacts with the coronal MRIs of the patients, we reconstructed the whole lead trajectories. Then the STN and other nuclei nearby in the standard atlas space were visualized with the grey images of the standard atlas, accomplishing the lead reconstruction and nerve nuclei visualization near STN of all patients. This study provides intuitive and quantitative information to identify the accuracy of the DBS electrode implantation, which could help decide the post-operative programming setting.