west china medical publishers
Keyword
  • Title
  • Author
  • Keyword
  • Abstract
Advance search
Advance search

Search

find Keyword "intensity" 56 results
  • The Application of High Intensity Focused Ultrasound in the Tumor Treatment

    bjectiveTo evaluate the efficacy and limits of high intensity focused ultrasound (HIFU) in tumor treatment. MethodsThe references about the application of HIFU in tumor treatment in recent years were reviewed.ResultsHIFU caused localized hyperthermia at predictable depth in a few seconds to make the tumor tissue coagulative necrosis without injuring surrounding tissue. HIFU treatment had the advantages of low morbidity, noninvasiveness, avoidance of systemic side effects, and repeatitiveness. However, the utilization of HIFU sometimes could be limited by some factors such as imaging technique, organ movement, incomplete tissue destruction, etc.ConclusionHIFU is a promising noninvasive therapy for tumor treatment, though there are lots of problems to be further studied.

    Release date:2016-08-28 05:10 Export PDF Favorites Scan
  • STUDY OF THE MAGNETIC PIECE DRESSINGS OF DIFFERENT INTENSITIES ON THE EFFECT OF SURVIVAL OF SKIN FLAPS AND HEALING OF INCISIONAL WOUNDS

    The comparative study of local application of magnetic piece dressings of different intensities (Gs) on the effect of survival of 48 skin flaps (2×5cm in size) and the healing of the incisional wornds was reported. Twelve Japanese long ear white rabbits were used for this study. It was noted that the magnetic field intensity of 200or 400 Gs showed remarkable increase of the area of survival of the skin flaps and enhancement of the healing of the incisional wounds.

    Release date:2016-09-01 11:38 Export PDF Favorites Scan
  • A meta-analysis of the comparison of intervention effects of high-intensity interval training and moderate-intensity continuous training on patients with metabolic syndrome

    Objective To explore the difference of intervention effect between high-intensity interval training (HIIT) and moderate-intensity continuous training (MICT) on patients with metabolic syndrome (MetS). Methods China National Knowledge Infrastructure, WanFang Data, PubMed, Web of Science and EBSCO were searched for randomized controlled trials (RCTs) till May 2022. Two reviewers independently reviewed the literature, extracted data, and assessed the risk of bias of included RCTs. Comprehensive Meta-Analysis software was used for meta-analysis. Result A total of 5 RCTs were included, including 216 patients. The results of meta-analysis showed that: except fasting blood glucose, high-density lipoprotein cholesterol, systolic blood pressure, waist circumference, body mass index and body fat percentage (P>0.005), low-density lipoprotein cholesterol [mean difference (MD)=−7.487 mg/dL, 95% confidence interval (CI) (−12.543, −2.431) mg/dL, P=0.004], total cholesterol [MD=−11.487 mg/dL, 95%CI (−16.523, −6.452) mg/dL, P<0.001], triglycerides [MD=−26.296 mg/dL, 95%CI (−50.557, −2.035) mg/dL, P=0.034] and diastolic blood pressure [MD=−2.770 mm Hg (1 mm Hg=0.133 kPa), 95%CI (−5.131, −0.409) mm Hg, P=0.021] of HIIT were better than MICT. Conclusion In terms of blood glucose indicators and morphological indicators, the effect of HIIT group and MICT group was similar, but the effect of HIIT on blood lipid indicators and blood pressure indicators of patients with MetS was better than MICT.

    Release date:2023-02-14 05:33 Export PDF Favorites Scan
  • Effect of High Intensity Focused Ultrasound on Immunity of Patients with Advanced Primary Liver Cancer

    【Abstract】ObjectiveTo investigate the effect of high intensity focused ultrasound (HIFU) on the immunity of patients with advanced primary liver cancer (PLC). MethodsForty cases of PLC admitted to our institution from Mar. 2003 to Dec. 2003 were included in this study. Patients were divided into 2 groups and received either HIFU or radiofrequency ablation (RFA) treatment randomly. CD3, CD4, CD8, CD4/CD8, NK, IL-2, TNF were chosen to assess the immune status before and after treatment. The results were compared statistically. ResultsThe survival rate after HIFU was 80.0%, 61.1%, 42.9%, 33.3% at 3 months, 6 months, 9 months and 1 year respectively, which was similar to that after RFA treatment. The changes of immunity parameters of CD3, CD4, CD8, CD4/CD8, NK, IL-2 and TNF were not significant after HIFU treatment. In addition, the differences of those parameters between HIFU group and RFA group were insignificant. ConclusionThere are no detrimental effects on immunity in the early period after HIFU treatment.

    Release date:2016-09-08 11:52 Export PDF Favorites Scan
  • Study on the regulatory effect of low intensity retinal ultrasound stimulation on the neural activity of visual cortex

    Low-intensity ultrasound stimulation of the retina has the ability to modulate neural activity in the primary visual cortex (V1), however, it is currently unclear how different intensities and durations of ultrasonic stimulation of the retina modulate neural activity in V1. In this paper, we recorded local field potential (LFP) signals in the V1 brain region of mice under different ultrasound intensities and different stimulation times. The amplitude of LFP corresponding to 1 s before ultrasound stimulation to 2 s after stimulation (–1–2 s) was analyzed, including the power and sample entropy of delta, theta, alpha beta, and low gamma frequency bands. The experimental results showed that, as the stimulation intensity increased, the peak value of the LFP in the visual cortex showed a linear upward trend; the power in the delta and theta frequency bands showed a linear upward trend, and the sample entropy showed a linear downward trend. With increases of stimulation duration, the peak value of the LFP in the visual cortex showed an upward trend, and the upward trend gradually weakened; the power in the delta frequency band showed an upward trend, the sample entropy showed a linear upward trend, and the sample entropy in the theta frequency band showed a downward trend. The results show that low-intensity ultrasonic stimulation of the retina has a significant modulatory effect on neural activity in the visual cortex. The study provides insights into the mechanisms by which ultrasonic stimulation regulates visual system function. Furthermore, it clarifies the patterns of parameter selection, facilitating the development of personalized multi-parameter modulation for the treatment of visual neural degeneration, retinal disorders and related research areas.

    Release date:2024-12-27 03:50 Export PDF Favorites Scan
  • Clinical status of advanced pancreatic cancer treated with high intensity focused ultrasound

    ObjectiveTo explore the application value of high intensity focused ultrasound (HIFU) in the treatment of advanced pancreatic cancer.MethodThe domestic and foreign literatures about studies of HIFU treating advanced pancreatic cancer in recent years were retrieved and summarized.ResultsHIFU could prolong the survival time, control pain, and enhance the body’s immune function in patients with advanced pancreatic cancer. There were no obvious serious complications during the treatment process. The combined treatment with radiotherapy, chemotherapy, and traditional Chinese medicine could obviously prolong the survival time and improve the quality of life for the patients with advanced pancreatic cancer.ConclusionsHIFU is an important component in the comprehensive treatment of advanced pancreatic cancer. However, because there is no uniform standard for the dosage of HIFU treatment, the sample size of many related studies is small, so the research results have certain limitations, so more studies are needed to improve their understanding of advanced pancreatic cancer in order to better serve clinical workin future.

    Release date:2021-02-08 07:10 Export PDF Favorites Scan
  • The Effectiveness Evaluation of Antibiotics Management by Applying PDCA Cycle Model

    ObjectiveTo analyze the effectiveness of PDCA cycle model in antibiotics management by comparison of antibiotics use before and after the use of PDCA in a tertiary hospital. MethodsProspective study was adopted to analyze the using rate of antibiotics in outpatients, emergent patients and inpatients between June 2011 and December 2013. ResultsThe reasonable antibiotics use was improved since the beginning of PDCA cycle model. The antibiotics using rates of outpatients were 33.00%, 29.09% and 19.31%, of emergent patients were 45.00%, 32.81% and 28.94%, and of inpatients were 71.00%, 57.76% and 53.28% in year 2011 (from June to December), 2012 (from January to December) and 2013 (from January to December) respectively. Meanwhile, ClassⅠ incision antimicrobial use also decreased and bacteria examination rate continuously increased during the last three years. As a consequence, patients' cost was reduced. ConclusionThe PDCA cycle model promotes the standardized management of clinical medication application.

    Release date: Export PDF Favorites Scan
  • Effectiveness and Safety of High-intensity Focused Ultrasound for Bone Tumors: A Systematic Review

    ObjectiveTo explore the effectiveness and safety of high-intensity focused ultrasound (HIFU) for bone tumors, so as to provide a reference for clinical decision. MethodsPubMed, EMbase, The Cochrane Library, CNKI and VIP databases were systematically searched for clinical effectiveness and safety studies of HIFU for bone tumors up to August 2014. Study selection, data extraction and quality assessment were applied independently by two reviewers, and then RevMan 5.1 software was used for conducting meta-analysis. If the data cannot be synthesized, the research outcome was described with a qualitative analysis. ResultsA total of 10 case series including 257 patients (157 males, 100 females) were included. The current evidence indicated that overall survival rates for all primary bone malignancy at 1-, 2-, 3- and 5-year were 89.8%, 72.3%, 60.5% and 50.5%, respectively. For the patients with clinical stage Ⅱb, the rates were 93.3%, 82.4%, 75% and 63.7%, respectively. For those with clinical stage Ⅲ, the rates were 79.2%, 42.2%, 21.1% and 15.8%, respectively. The local recurrence rate of HIFU for bone tumors was 7% to 9%, and recurrences at 1-, 2-, 3- and 5-year were 0%, 6.2%, 11.8% and 11.8%, respectively. The amputation rate was 2% to 7%. The adverse reaction rate was 27.2% (70/257), and among them the main was mild skin burn (21/257, 8.2%), followed by I degree burns (16/257, 6.2%), nerve damage (10/257, 3.9%) and fracture (6/257, 2.3%). ConclusionHIFU provide an alternative choice for patients with bone malignancy, with a certain effectiveness and safety. However, high-quality, large-scale randomized controlled trials or cohort studies which may focus on vary kinds of tumors, clinical stage and site of lesions are urgently needed, so that clinicians can use sufficient evidence for their clinical decision-making.

    Release date: Export PDF Favorites Scan
  • A gradient-based direct aperture optimization

    Aiming at the disadvantages of traditional direct aperture optimization (DAO) method, such as slow convergence rate, prone to stagnation and weak global searching ability, a gradient-based direct aperture optimization (GDAO) is proposed. In this work, two different optimization methods are used to optimize the shapes and the weights of the apertures. Firstly, in order to improve the validity of the aperture shapes optimization of each search, the traditional simulated annealing (SA) algorithm is improved, the gradient is introduced to the algorithm. The shapes of the apertures are optimized by the gradient based SA method. At the same time, the constraints between the leaves of multileaf collimator (MLC) have been fully considered, the optimized aperture shapes are meeting the requirements of clinical radiation therapy. After that, the weights of the apertures are optimized by the limited-memory BFGS for bound-constrained (L-BFGS-B) algorithm, which is simple in calculation, fast in convergence rate, and suitable for solving large scale constrained optimization. Compared with the traditional SA algorithm, the time cost of this program decreased by 15.90%; the minimum dose for the planning target volume was improved by 0.29%, the highest dose for the planning target volume was reduced by 0.45%; the highest dose for the bladder and rectum, which are the organs at risk, decreased by 0.25% and 0.09%, respectively. The results of experiment show that the new algorithm can produce highly efficient treatment planning a short time and can be used in clinical practice.

    Release date:2018-08-23 03:47 Export PDF Favorites Scan
  • Automatic detection method of intracranial aneurysms on maximum intensity projection images based on SE-CaraNet

    Conventional maximum intensity projection (MIP) images tend to ignore some morphological features in the detection of intracranial aneurysms, resulting in missed detection and misdetection. To solve this problem, a new method for intracranial aneurysm detection based on omni-directional MIP image is proposed in this paper. Firstly, the three-dimensional magnetic resonance angiography (MRA) images were projected with the maximum density in all directions to obtain the MIP images. Then, the region of intracranial aneurysm was prepositioned by matching filter. Finally, the Squeeze and Excitation (SE) module was used to improve the CaraNet model. Excitation and the improved model were used to detect the predetermined location in the omni-directional MIP image to determine whether there was intracranial aneurysm. In this paper, 245 cases of images were collected to test the proposed method. The results showed that the accuracy and specificity of the proposed method could reach 93.75% and 93.86%, respectively, significantly improved the detection performance of intracranial aneurysms in MIP images.

    Release date: Export PDF Favorites Scan
6 pages Previous 1 2 3 ... 6 Next

Format

Content