  • Progress in surgical treatment of inferior patellar pole fractures

    Objective To summarize the surgical treatment methods and progress of inferior patellar pole fractures and provide reference for clinical application. Methods The literature on surgical treatment of inferior patellar pole fractures was extensively reviewed, and the relevant research progress, advantages, and limitations were summarized. Results The inferior pole of the patella is an important part of the knee extension device, which can strengthen the force arm of the quadriceps. Inferior patellar pole fractures are relatively rare and often comminuted, usually requiring surgical treatment. At present, there are various methods to treat inferior patellar pole fractures, including patellectomy of inferior pole, tension-band wiring technique, plate internal fixation, suture anchor fixation, claw-like shape memory alloy, separate vertical wiring technique. Different methods have their own characteristics, advantages, and disadvantages. The single internal fixation method has more complications and is easy to cause fixation failure. Therefore, the trend of combining various internal fixation methods is developing at present. Conclusion When the main fragment of the inferior patellar pole fracture is large and mainly distributed transversely, the combination protocol based on tension-band wiring technique can be regarded as an ideal choice. When the fragments are severely damaged and small, the comprehensive protocol based on suture fixation can result in a better postoperative functional recovery.

    Release date:2023-02-13 09:57 Export PDF Favorites Scan
  • Effectiveness of proximal femur bionic nail for intertrochanteric fracture in the elderly

    Objective To evaluate effectiveness of proximal femur bionic nail (PFBN) in treatment of intertrochanteric fractures in the elderly compared to the proximal femoral nail antirotation (PFNA). Methods A retrospective analysis was made on 48 geriatric patients with intertrochanteric fractures, who met the selection criteria and were admitted between January 2020 and December 2022. Among them, 24 cases were treated with PFBN fixation after fracture reduction (PFBN group), and 24 cases were treated with PFNA fixation (PFNA group). There was no significant difference in baseline data such as age, gender, cause of injury, side and type of fracture, time from injury to operation, and preoperative mobility score, American Society of Anesthesiologists (ASA) score, Alzheimer’s disease degree scoring, self-care ability score, osteoporosis degree (T value), and combined medical diseases between the two groups (P>0.05). The operation time, intraoperative blood loss, number of blood transfusions, transfusion volume, length of hospital stay, occurrence of complications, weight-bearing time after operation, and postoperative visual analogue scale (VAS) score, walking ability score, mobility score, self-care ability score were recorded and compared between the two groups. And the radiographic assessment of fracture reduction quality and postoperative stability, and fracture healing time were recorded. ResultsThe operations in both groups were successfully completed. All patients were followed up 6-15 months with an average time of 9.8 months in PFBN group and 9.6 months in PFNA group. The operation time was significantly longer in PFBN group than in PFNA group (P<0.05), but there was no significant difference in intraoperative blood loss, number of blood transfusions, transfusion volume, length of hospital stay, change in activity ability score, and change in self-care ability score between the two groups (P>0.05). The weight-bearing time after operation was significantly shorter in PFBN group than in PFNA group (P<0.05), and the postoperative VAS score and walking ability score were significantly better in PFBN group than in PFNA group (P<0.05). Radiographic assessment showed no significant difference in fracture reduction scores and postoperative stability scores between the two groups (P>0.05). All fractures healed and there was no significant difference in fracture healing time between the two groups (P>0.05). The incidence of complications was significantly lower in PFBN group (16.7%, 4/24) than in PFNA group (45.8%, 11/24) (P<0.05). ConclusionCompared with PFNA, PFBN in the treatment of elderly intertrochanteric fractures can effectively relieve postoperative pain, shorten bed time, reduce the risk of complications, and facilitate the recovery of patients’ hip joint function and walking ability.

    Release date:2023-10-11 10:17 Export PDF Favorites Scan
  • Clinical study on the subchondral screw compression technique assisted reduction of residual or secondary collapse of lateral tibial plateau

    Objective To explore the reduction and support effect of the subchondral screw compression technique for residual or secondary collapse of the lateral tibial plateau during operation. Methods Between January 2020 and June 2021, 11 patients with residual or secondary collapse of the lateral tibial plateau during operation were treated with the subchondral screw compression technique. There were 6 males and 5 females, aged 52.3 years old (range, 27-64 years). The fractures were caused by traffic accident in 10 cases and falling from height in 1 case and located at the left knee in 6 cases and the right knee in 5 cases. According to Schatzker classification, there were 5 cases of type Ⅱ fractures, 4 cases of type Ⅲ fractures, and 2 cases of type Ⅴfractures. According to the three columns classification, there were 5 cases of lateral column, 4 cases of lateral column and posterior column, and 2 cases of three columns. The time from injury to operation was 4.5 days (range, 3-7 days). During the follow-up, X-ray films were obtained and the Rasmussen standard was used to evaluate the quality of fracture reduction, meanwhile fracture healing was observed. The medial proximal tibial angle (mPTA), posterior tibial slope angle (pTSA), and articular surface collapse were measured at immediate and 12 months after operation. The knee joint range of motion was evaluated at last follow-up, and the knee joint function was evaluated using the Hospital for Special Surgery (HSS) score. Results All operations were successfully completed, with a mean operation time of 71.4 minutes (range, 55-120 minutes), and a mean hospital stay of 8.0 days (range, 5-13 days). The incisions all healed by first intention, without complications such as infection, flap necrosis, or vascular and nerve injury. All patients were followed up 16.5 months on average (range, 12-24 months). X-ray films showed that the fracture reduction score was 14-18 (mean, 16.7) according to Rasmussen score criteria; and 5 cases were rated as excellent and 6 as good. All fractures healed clinically with a mean clinical healing time of 14.9 weeks (range, 12-16 weeks), and there was no complications such as plate or screw loosening. At 12 months after operation, the mPTA and pTSA were (87.5±1.7)° and (6.2±3.1)°, respectively; there was no significant difference when compared to the values at immediate after operation [(87.6±1.8)° and (6.5±3.1)°] (P>0.05). The articular surface of the tibial plateaus was effectively supported, and it collapsed again by 0-1.0 mm at 12 months, with an average of 0.4 mm. At last follow-up, the knee joint range of motion was 115°-135° (mean, 126.8°) and the HSS score for knee joint function was 87-98 (mean, 93.9). Five patients underwent secondary operation to remove the internal fixator at 12-18 months after operation.ConclusionThe subchondral screw compression technique is helpful for the reduction of residual or secondary collapse of the lateral tibial plateau during operation, and can provide good support for osteochondral blocks.

    Release date:2023-12-12 05:09 Export PDF Favorites Scan
  • Short-term effectiveness of polyaxial locking plate for fixation of femoral neck fracture in middle-aged and elderly patients

    Objective To evaluate the feasibility and short-term effectiveness of polyaxial locking plate for fixation of femoral neck fracture in the middle-aged and elderly patients. Methods A retrospective analysis was made on the clinical data of 13 patients with femoral neck fracture undergoing fixation with polyaxial locking plates between September 2013 and June 2015 (group A) and 13 patients with femoral neck fracture undergoing fixation with three cannulated screws in the same period (group B). There was no significant difference in gender, age, side, cause of injury, Garden type, type of fracture position, type of Pauwels angle, Singh index, time between injury and operation, and preoperative complications between 2 groups (P>0.05). The femoral neck shortening at 1 year postoperatively, and fracture nonunion, femoral head necrosis, and Harris hip score at last follow-up were compared between 2 groups. Results The follow-up time was (19.23±3.98) months in group A and (18.00±3.61) months in group B, showing no significant difference between 2 groups (t=2.063,P=0.417). No femoral head necrosis occurred in group A, but head necrosis occurred in 1 case of group B, and hemiarthroplasty was performed. There was no significant difference in the rate of femoral head necrosis between 2 groups (χ2=0.000,P=1.000). Bone union was obtained in the other patients of 2 groups. The Harris hip score of group A (85.23±2.95) was significantly higher than that of group B (81.92±3.64) at last follow-up (t=2.064,P=0.018). No infection or internal fixation failure occurred in 2 groups. One case had pain at the outer thigh at 1 month after operation in group A, but pain relief was achieved at 3 months after operation. At 1 year after operation, no femoral neck shortening occurred in group A, but degree I, II, and III femoral neck shortening was observed in 3, 2, and 8 cases of group B, respectively, showing significant difference between 2 groups (Z=–4.714,P=0.000). Conclusion Although fixation with polyaxial locking plate for femoral neck fracture in the middle-aged and elderly patients has similar femoral head necrosis rate to fixation with cannulated screws, it has advantages in preventing neck shortening and improving hip joint function after operation.

    Release date:2017-02-15 09:26 Export PDF Favorites Scan
  • Treatment of posterolateral tibial plateau fractures with a novel lateral tibial plateau annular plate via fibular neck osteotomy approach

    Objective To investigate the effectiveness of a novel lateral tibial plateau annular plate (hereinafter referred to as the novel plate) fixation via fibular neck osteotomy approach for posterolateral tibial plateau fractures. Methods Between January 2015 and December 2018, 22 patients with posterolateral tibial plateau fractures were treated. There were 10 males and 12 females with an average age of 39.0 years (range, 25-56 years). Seven fractures were caused by falls, 10 by traffic accidents, and 5 by falling from height. The time from injury to hospitalization ranged from 3 to 12 days, with an average of 7.0 days. All patients were closed fractures. According to Schatzker classification, the fractures were classified as type Ⅱ in 8 cases, type Ⅲ in 9 cases, type Ⅴ in 1 case, and type Ⅵ in 4 cases. The fractures were fixed with the novel plates after reduction via fibular neck osteotomy approach. The fracture reduction and healing were observed by X-ray film after operation. The range of motion of the knee joint was recorded and the function was evaluated by modified American Hospital for Special Surgery (HSS) score. Results All operations were completed successfully. The operation time was 60-95 minutes (mean, 77.6 minutes). The intraoperative blood loss was 100-520 mL (mean, 214.5 mL). There was 1 case of common peroneal nerve injury during operation and 2 cases of fat liquefaction of incision after operation. All patients were followed up 13-32 months (mean, 19.4 months). Postoperative X-ray films showed that the fracture reduction was good in 17 cases and moderate in 5 cases, and all fractures healed with a healing time of 10-18 weeks (mean, 13.0 weeks). At last follow-up, the range of motion of the knee joint ranged from 100° to 145° in flexion (mean, 125.5°) and from 0° to 4° in extension (mean, 1.2°). The modified HSS score was 82-95 (mean, 86.3). There was no complications such as plate deformation, screw fracture, fracture reduction loss, skin necrosis, and so on. Conclusion For posterolateral tibial plateau fractures, the novel plate fixation via fibular neck osteotomy approach has the advantages of clear intraoperative field, firm fracture fixation, and less postoperative complications, which is beneficial to the recovery of knee joint function.

    Release date:2022-09-30 09:59 Export PDF Favorites Scan
  • Biomechanical effects of three internal fixation modes on femoral subtrochanteric spiral fractures in osteoporotic patients by finite element analysis

    Objective The biomechanical characteristics of three internal fixation modes for femoral subtrochanteric spiral fracture in osteoporotic patients were compared and analyzed by finite element technology, so as to provide the basis for the optimization of fixation methods for femoral subtrochanteric spiral fracture. MethodsTen female patients with osteoporosis and femoral subtrochanteric spiral fractures caused by trauma, aged 65-75 years old, with a height of 160-170 cm and a body weight mass of 60-70 kg, were selected as the study subjects. The femur was scanned by spiral CT and a three-dimensional model of the femur was established by digital technology. The computer aided design models of proximal intramedullary nail (PFN), proximal femoral locking plate (PFLP), and the combination of the two (PFLP+PFN) were constructed under the condition of subtrochanteric fracture. Then the same load of 500 N was applied to the femoral head, and the stress distribution of the internal fixators, the stress distribution of the femur, and the displacement of femur after fracture fixation were compared and analyzed under the three finite element internal fixation modes, so as to evaluate the fixation effect. ResultsIn the PFLP fixation mode, the stress of the plate was mainly concentrated in the main screw channel, the stresses of the different part of the plate were not equal, and gradually decreased from the head to the tail. In the PFN fixation mode, the stress was concentrated in the upper part of the lateral middle segment. In the PFLP+PFN fixation mode, the maximum stress appeared between the first and the second screws in the lower segment, and the maximum stress appeared in the lateral part of the middle segment of the PFN. The maximum stress of PFLP+PFN fixation mode was significantly higher than that of PFLP fixation mode, but significantly lower than that of PFN fixation mode (P<0.05). In PFLP and PFN fixation modes, the maximum stress of femur appeared in the medial and lateral cortical bone of the middle femur and the lower side of the lowest screw. In PFLP+PFN fixation mode, the stress of femur concentrated in the medial and lateral of the middle femur. There was no significant difference in the maximum stress of femur among the three finite element fixation modes (P>0.05). The maximum displacement occurred at the femoral head after three finite element fixation modes were used to fix subtrochanteric femoral fractures. The maximum displacement of femur in PFLP fixation mode was the largest, followed by PFN, and PFLP+PFN was the minimum, with significant differences (P<0.05). ConclusionUnder static loading conditions, the PFLP+PFN fixation mode produces the smallest maximum displacement when compared with the single PFN and PFLP fixation modes, but its maximum plate stress is greater than the single PFN and PFLP fixation mode, suggesting that the combination mode has higher stability, but the plate load is greater, and the possibility of fixation failure is higher.

    Release date:2023-06-07 11:13 Export PDF Favorites Scan
  • CURATIVE EFFECT OF MINIMALLY INVASIVE PERCUTANEOUS PLATE OSTEOSYNTHESIS ASSISTED BY ARTHROSCOPY ON 29 CASES OF TIBIAL PLATEAU FRACTURES

    Objective To investigate the cl inical effect of minimally invasive internal fixation percutaneous plate osteosynthesis (MIPPO) assisted by arthroscopy on tibial plateau fractures. Methods From September 2005 to December 2007, 29 patients with tibial plateau fracture underwent arthroscopy-assisted MIPPO, including 18 males and 11 females aged18-59 years old (average 34.7 years old). There were 8 cases of type II, 10 of type III, 5 of type IV, 3 of type V, and 3 of type VI according to Schatzker classification system. The fracture was combined with meniscus injury in 13 cases, anterior cruciate l igament injury in 4 cases, and medial collateral l igament injury in 3 cases. The time from injury to operation was 2-10 days. Firstly, the combined injury was treated under arthroscopy. Then, reduction of tibial plateau fractures was performed, bone grafting was conducted in the area of bone defect, and internal fixation using strut plates was performed after establ ishing subcutaneous tunnel via minimally invasion. Early rehabil itation activities were carried out for each patient 1 day after operation. Results No early compl ications such as poor heal ing of incisions, infections, and osteofascial compartment syndrome occurred. Over the follow-up period of 12-39 months (average 24 months), there was no failure of internal fixation, traumatic knee osteoarthritis, and inversion and eversion of the knee. The fractures healed within 3-4.5 months (average 3.5 months). The cl inical effect was excellent in 23 cases, good in 4 cases, and fair in 2 cases according to Lysholm knee rating system, and the excellent and good rate was 93.1%. Conclusion Arthroscopy-assisted MIPPO is a safe and effective way of managing tibial plateau fractures due to its features of minimal invasion, earl ier recovery, fewer compl ications, and simultaneous treatment of associated intra-articular injuries.

    Release date:2016-09-01 09:07 Export PDF Favorites Scan
  • CLINICAL RESEARCH ON ARTERIOVENOUS INTERNAL FISTULA MADE BY VARIOUS BLOOD VESSELS

    OBJECTIVE To compare the permeability and incidence rate of complication of arteriovenous internal fistula made by autogenous, homologous, and artificial Teflon blood vessels. METHODS Two hundred and forty one cases with arteriovenous internal fistula made by autogenous, homologous, and artificial Teflon blood vessels were followed up to compare the permeability and incidence rate of complication at 6 months, 1 year, 3 years, and 5 years. RESULTS The incidence rate of complication of autogenous blood vessels was lowest, it had no statistical differences compared with arteriovenous internal fistula made by homologous blood vessels. The permeability of arteriovenous internal fistula made by homologous blood vessels was highest, and it had no statistical differences compared with autogenous blood vessels. The permeability of arteriovenous internal fistula made by artificial Teflon blood vessels was lowest, but the incidence rate of complication was highest, and it had significantly statistical differences compared with arteriovenous internal fistula made by autogenous blood vessels (P lt; 0.01). CONCLUSION Arteriovenous internal fistulas made by autogenous and homologous blood vessels have high permeability and low incidence rate of complication, they are superior to the arteriovenous internal fistula made by artificial Teflon blood vessels.

    Release date:2016-09-01 10:25 Export PDF Favorites Scan
  • Application of “door-shaft method” in limited open reduction and internal fixation with locking plate for two- and three-part fractures of the proximal humerus

    ObjectiveTo investigate the effectiveness of limited open reduction via “door-shaft method” and internal fixation with locking plate for two- and three-part fractures of the proximal humerus.MethodsThe clinical data of 64 patients with proximal humeral fractures who were admitted between January 2013 and December 2016 and met the selection criteria were retrospectively analyzed. There were 23 males and 41 females, with an average age of 68.0 years (range, 50-89 years). The injuries were caused by falling in 57 cases, traffic accident in 5 cases, and falling from height in 2 cases. The interval between injury and operation was 1-7 days (mean, 2.1 days). According to Neer classification, there were 28 cases of two-part fractures and 36 cases of three-part fractures. According to the angulation direction of the proximal humeral neck shaft angle, there were 21 cases of adduction fractures and 43 cases of abduction fractures. The fractures were treated with limited open reduction via “door-shaft method” and proximal humerus internal locking systems for internal fixation. The operation time, intraoperative blood loss, number of fluoroscopy, hospital stay, and complications were recorded. The fracture healing was reviewed by X-ray film and the healing time was recorded. The shoulder joint function was evaluated by Neer score standard.ResultsThe operation time was 45-127 minutes, with an average of 82.3 minutes. The intraoperative blood loss was 30-125 mL, with an average of 62.7 mL. Intraoperative fluoroscopy was performed 30-69 times, with an average of 37.0 times. The hospital stay was 6-23 days, with an average of 10.3 days. All incisions healed by first intention. All patients were followed up 12-37 months, with an average of 18.3 months. X-ray film re-examination showed that all fractures healed, the healing time was 12-21 weeks, with an average of 14.3 weeks. After operation, 3 cases had shoulder stiffness and 1 case had fracture malunion. At last follow-up, the Neer score of shoulder joint function was 49-97, with an average of 83.1. Among them, 38 cases were excellent, 13 cases were good, 10 cases were fair, and 3 cases were poor. The excellent and good rate was 79.7%. The excellent and good rate of patients with two-part fractures was 82.1% (23/28), and the excellent and good rate of patients with three-part fractures was 77.8% (28/36).ConclusionThe “door-shaft method” not only reduces the difficulty of the Joystick technique in the reduction of proximal humerus fractures, but also provides auxiliary stability. It is used for limited open reduction and internal fixation with locking plate to treat the two- and three-part fractures of the proximal humerus, which can achieve good effectiveness.

    Release date:2021-07-29 05:02 Export PDF Favorites Scan
  • APPLICATION OF VACUUM SEALING DRAINAGE IN SEVERE SKIN CLOSED INTERNAL DEGLOVING INJURY

    【Abstract】 Objective To investigate the effectiveness of the vacuum sealing drainage (VSD) technique with split middle thickness skin replantation for the treatment of severe skin closed internal degloving injury (CIDI). Methods Between July 2008 and April 2011, 16 patients with severe skin CIDI were treated. There were 11 males and 5 females, aged 17-56 years (mean, 28 years). Injury was caused by traffic accident in all cases. The time between injury and operation was 2-8 hours (mean, 5 hours). Peeling skin parts included the upper limb in 3 cases and the lower limb in 13 cases. The range of skin exfoliation was 5%-12% (mean, 7%) of the body surface area with different degree of skin contamination. After thorough debridement, exfoliative skin was made split middle thickness skin graft for in situ replantation, and then VSD was performed. Results After 7 days of VSD therapy, graft skin survived successfully in 14 cases; partial necrosis of graft skin occurred in 2 cases, and was cured after thorough debridement combined with antibiotics for 7 days. All patients were followed up 6-18 months (mean, 12 months). The appearance of the limb was satisfactory without obvious scar formation, and the blood supply and sensation were normal.The joint function was normal. Conclusion For patients with severe skin CIDI, VSD treatment combined with split middle thickness skin replantation can improve the local blood circulation of the limb, promote replantation skin survival, and shorten healing time of wound. The clinical effectiveness is satisfactory.

    Release date:2016-08-31 04:21 Export PDF Favorites Scan